Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Bulletin website includes the following: Rulemakings by State agencies; Proposed Rulemakings by State agencies; State agency notices; the Governor’s Proclamations and Executive Orders; Actions by the General Assembly; and Statewide and local court rules.

PA Bulletin, Doc. No. 99-885

NOTICES

TURNPIKE COMMISSION

Retention of an Engineering Firms

[29 Pa.B. 2833]

Full Depth Roadway Reconstruction
Cumberland County

Reference No. 3-113

   The Turnpike Commission (Commission) will retain an engineering firm for the design of the Full Depth Roadway Reconstruction Project between approximate Mileposts 216.00 and 226.00 in Cumberland County. The selected firm will be responsible for the pre-final and final design of this project.

   The engineering services required would include supplemental field surveys, cross sections, evaluation of utility conflicts and potential relocations, development of erosion and sedimentation control plans and specifications, preparation of hydraulic reports for waterway approvals, preliminary and final traffic control plans, structural foundation reports, preparation of Type, Size and Location and final bridge plans, preparation of preliminary and final right-of-way plans, geotechnical investigations, preparation of preliminary and final construction plans and specifications in order for the Commission to bid the total reconstruction of the roadway generally between Milepost 216.00 and 226.00. The intent is to rebuild the roadway and widen the existing 10-foot median to a width that will be based on preliminary evaluations. It is anticipated that all of the mainline structures will require widening and that all overhead structures within the project area will be evaluated for rehabilitation, replacement or elimination. We will consider either rubbilizing the existing concrete roadway and overlay with bituminous material, or removing the existing pavement and replace with full-depth bituminous. An entirely new drainage system will be installed.

   In addition, low-level photography will be available in this area to an accuracy of + .05 feet. Hard copies of the mapping and a disk will be provided to the consultant for their use. A digital terrain model in AutoCADD DWG format will also be provided. The consultant will be required to perform supplemental surveys and reestablish the existing centerline of the Turnpike. Also, cross sections will be cut and plotted from the available information. The design for this project will be performed in Metric Units. All plans (drawings), including cross-sections, profiles, and the like will be prepared utilizing AutoCADD DWG format. Translation of the plans into AutoCADD DWG format is not acceptable.

   Direct inquiries to Michael D. Shaak, P.E., at 939-9551, extension 5380; or by e-mail at mshaak@paturnpike.com.

   The following factors will be considered by the Commission during the evaluation of the firms submitting Letters of Interest for this project:

   a.  Specialized experience and technical competence of prime consultant and subconsultants. The Team must clearly demonstrate an ability to analyze available data to make decisions and develop plans to complete the project in a timely and cost effective manner.

   b.  Past record of performance with respect to cost control, work quality, ability to meet schedules and previous experience on similar projects. The consultant should identify similar projects that have been completed by that firm as the prime, the magnitude of the project, and the client.

   c.  The specific experience and number of individuals who constitute the firm.

   d.  Location of consultant's office where the work will be performed.

   e.  Workload of the prime consultant and subconsultants for all Department of Transportation (Department) and Commission projects.

   f.  Other factors, if any, specific to the project.

General Requirements and Information

   Firms interested in providing the above work and services are invited to submit a Letter of Interest with the required information. The Letters of Interest must include the following:

   1.  One page transmittal letter clearly identifying the project reference number, brief description of the project from the advertisement, the firm's Federal identification number, the firm's legal name, contact person or project manager, address of corporate office and project office. (If the firm has multiple offices, the location of the office performing the work must be identified)

   2.  Three page expression of interest in the advertised project. Each firm should demonstrate their ability to perform the specific requirements indicated for this project and provide explanation that the firm has successfully completed similar type projects of the same magnitude.

   3.  An organization chart for the Project, identifying key personnel and any subconsultants and their roles. Any deviation from the subconsultant's listed in the letter of interest will require written approval from the Commission.

   4.  Tabulation of workload for the prime consultant and all subconsultants for all Department and Commission projects.

   5.  Annual Qualification Package submitted to the Department for the current year, containing the following for the prime consultant and all subconsultants which should be attached to the back of the letter of interest (subs to follow primes):

   *  Standard Form (SF) 254--Architect-Engineer and Related Services Questionnaire in is entirety, not more than 1 year old as of the date of the advertisement.

   *  Resumes of key personnel expected to be involved in the project. (limit to one (1) 8 1/2 x 11 page, one (1) side, per person). Only resumes of key personnel should be included.

   *  Copy of the firm's registration to do business in this Commonwealth as provided by the Department of State for firms with out-of-State headquarters or corporations not incorporated in Pennsylvania.

   *  A copy of the Department's DBE/WBE Certification, if applicable.

   If a Joint Venture responds to a project advertisement, the Commission will not accept separate letters of interest from joint venture constituents. A firm will not be permitted to submit a letter of interest on more than one joint venture for the same project reference number. Also, a firm that responds to a project as a prime may not be included as a designated subconsultant to another firm that responds to the same project advertisement. This does not preclude a firm from being set forth as a designated subconsultant to more than one prime consultant responding to the project advertisement.

   The Commission is committed to the inclusion of disadvantaged, minority and woman firms in contracting opportunities. The minimum participation level for DBE/MBE/WBEs in this contract will be 10%. Responding firms shall clearly identify DBE/MBE/WBE firms, expected to participate in this contract, in their letter of interest. If the selected firm does not meet the minimum requirement for DBE/MBE/WBE participation, they will be required to demonstrate good faith efforts to achieve the required level. Proposed DBE/MBE/WBE firms must be certified by the Department at the time of the submission of the letter of interest. If further information is desired concerning DBE/MBE/WBE participation, direct inquiries to the Office of Equal Opportunity Development, Turnpike Commission at the above address, or by calling (717) 939-9551 Ext. 4241.

   Firms interested in performing the above services are invited to submit a letter of interest and required information to Barry L. Troup, P.E., Assistant Chief Engineer for Design, at the Turnpike Commission Administration Building located on Eisenhower Boulevard at the Harrisburg-East Interchange (No. 19). (FedEx address: Route 283 and Eisenhower Boulevard, Highspire, PA 17034) (Mailing Address: P. O. Box 67676, Harrisburg, PA 17106-7676).

   The letter of interest and required information must be received by 12 p.m. (noon), Friday, June 18, 1999. Any letters of interest received after this date and time will be time-stamped and returned.

   Based on an evaluation of acceptable letters of interest received in response to this solicitation, one firm will be selected for this project. The order of preference will be established for the purpose of negotiating an agreement with the highest ranked firm established by the Technical Review Committee and approved by the Selection Committee. Technical Proposals or Requests for Proposals will not be requested prior to selection.

   The Commission reserves the right to reject all letters of interest, to cancel solicitation requested under this notice, and/or to re-advertise solicitation for the work and services.

JAMES F. MALONE, III,   
Chairperson

[Pa.B. Doc. No. 99-885. Filed for public inspection May 28, 1999, 9:00 a.m.]



No part of the information on this site may be reproduced for profit or sold for profit.

This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.