Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Bulletin website includes the following: Rulemakings by State agencies; Proposed Rulemakings by State agencies; State agency notices; the Governor’s Proclamations and Executive Orders; Actions by the General Assembly; and Statewide and local court rules.

PA Bulletin, Doc. No. 13-910a

[43 Pa.B. 2721]
[Saturday, May 18, 2013]

[Continued from previous Web Page]

STATE CONSERVATION COMMISSION

PROPOSED NUTRIENT MANAGEMENT PLANS RELATED TO APPLICATIONS FOR NPDES PERMITS FOR CAFOs

 This notice provides information about agricultural operations that have submitted nutrient management plans (NMPs) for approval under 3 Pa.C.S. Chapter 5 and that have or anticipate submitting applications for new, amended or renewed NPDES permits, or Notices of Intent (NOIs) for coverage under a general permit, for CAFOs, under 25 Pa. Code Chapter 92a. This notice is provided in accordance with 25 Pa. Code Chapter 92a and 40 CFR Part 122, implementing The Clean Streams Law and the Federal Clean Water Act.

 Based upon preliminary reviews, the State Conservation Commission (SCC) or County Conservation Districts (CCD) working under a delegation agreement with the SCC have completed an administrative review of NMPs described. These NMPs are published as proposed plans for comment prior to taking final actions. The NMPs are available for review at the CCD office for the county where the agricultural operation is located. A list of CCD office locations is available at http://www.nacdnet.org/about/districts/directory/pa.phtml or can be obtained from the SCC at the office address listed or by calling (717) 787-8821.

 Persons wishing to comment on an NMP are invited to submit a statement outlining their comments on the plan to the CCD, with a copy to the SCC for each NMP, within 30 days from the date of this public notice. Comments received within the respective comment periods will be considered in the final determinations regarding the NMPs. Comments should include the name, address and telephone number of the writer and a concise statement to inform the SCC of the exact basis of the comments and the relevant facts upon which they are based. Comments should be sent to the SCC, Agriculture Building, Room 310, 2301 North Cameron Street, Harrisburg, PA 17110.

 Persons with a disability who require an auxiliary aid, service, including TDD users or other accommodations to seek additional information should contact the SCC through the Pennsylvania AT&T Relay Service at (800) 654-5984.

NUTRIENT MANAGEMENT PLAN—PUBLIC NOTICE SPREADSHEET

Agricultural Operation
Name and Address
CountyTotal
Acres
Animal Equivalent UnitsAnimal
Type
Special Protection Waters (HQ or EV or NA) Renewal/New
Craig Finkbiner
2452 Free Spring Church Road
McAlisterville, PA 17049
Juniata 390.81 900.7 Swine & Beef NA Renewal
Agricultural Operation
Name and Address
CountyTotal
Acres
Animal Equivalent UnitsAnimal
Type
Special Protection Waters (HQ or EV or NA) Application
or Action
Troester Dairy
175 Cannon Road
Mifflinburg PA 17844
Union 844.3 1015.4 Dairy NA Renewal
Jerry Martin
121 Paradise Lane
Lewisburg 17837
Union 1008.4 827.5 Swine NA New
Schrack Farms Partnership
860 West Valley Rd
Loganton, PA 17747
Clinton 1957 1.05 Dairy HQ Application

PUBLIC WATER SUPPLY (PWS) PERMITS

 Under the Pennsylvania Safe Drinking Water Act (35 P. S. §§ 721.1—721.17), the following parties have applied for PWS permits to construct or substantially modify public water systems.

 Persons wishing to comment on permit applications are invited to submit statements to the office listed before the application within 30 days of this public notice. Comments received within this 30-day comment period will be considered in the formulation of the final determinations regarding an application. A comment should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.

 Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.

 The permit application and related documents are on file at the office listed before the application and available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.

 Persons with a disability that require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

SAFE DRINKING WATER


Applications Received Under the Pennsylvania Safe Drinking Water Act (35 P. S. §§ 721.1—721.17)

Southwest Region: Water Supply Management Program Manager, 400 Waterfront Drive, Pittsburgh, Pa 15222-4745

Permit No. 0213519, Public Water Supply.

Applicant Hampton Shaler Water Authority
PO Box 66
3101 McCully Road
Allison Park, PA 15101
[Township or Borough] Shaler Township
Responsible Official Samuel Scarfone, Executive Director
Hampton Shaler Water Authority
PO Box 66
3101 McCully Road
Allison Park, PA 15101
Type of Facility Water system
Consulting Engineer KLH Engineers, Inc.
5173 Campbells Run Road
Pittsburgh, PA 15205
Application Received Date May 7, 2013
Description of Action Emergency construction of the Eade Avenue pump station.

MINOR AMENDMENT


Applications Received Under the Pennsylvania Safe Drinking Water Act

Southwest Region: Water Supply Management Program Manager, 400 Waterfront Drive, Pittsburgh, Pa 15222-4745

Application No. 0213518MA, Minor Amendment.

Applicant Pennsylvania American Water Company
800 West Hersheypark Drive
Hershey, PA 17033
[Township or Borough] South Fayette Township
Responsible Official David Kaufman, Vice President-Engineering
Pennsylvania American Water Company
800 West Hersheypark Drive
Hershey, PA 17033
Type of Facility Water system
Consulting Engineer Lennon, Smith, Souleret Engineering, Inc.
846 Fourth Avenue
Coraopolis, PA 15108
Application Received Date May 2, 2013
Description of Action Rehabilitation of the Mayview water storage tanks. The project includes the installation of waterlines to connect the tanks to the PAWC-Pittsburgh system.

Application No. 0213512MA, Minor Amendment.

Applicant Wilkinsburg-Penn Joint Water Authority
2200 Robinson Boulevard
Pittsburgh, PA 15235
[Township or Borough] Penn Hills
Responsible Official Nick Bianchi, Executive Director
Wilkinsburg-Penn Joint Water Authority
2200 Robinson Boulevard
Pittsburgh, PA 15235
Type of Facility Water system
Consulting Engineer Chester Engineers
1555 Coraopolis Heights Road
Moon Township, PA 15108
Application Received Date April 10, 2013
Description of Action Cleaning and painting of the Scenery Hill water storage tank.

Application No. 0213513MA, Minor Amendment.

Applicant Wilkinsburg-Penn Joint Water Authority
2200 Robinson Boulevard
Pittsburgh, PA 15235
[Township or Borough] Penn Hills
Responsible Official Nick Bianchi, Executive Director
Wilkinsburg-Penn Joint Water Authority
2200 Robinson Boulevard
Pittsburgh, PA 15235
Type of Facility Water system
Consulting Engineer Chester Engineers
1555 Coraopolis Heights Road
Moon Township, PA 15108
Application Received Date April 10, 2013
Description of Action Cleaning and painting of the Reservoir 7 water storage tank.

LAND RECYCLING AND ENVIRONMENTAL REMEDIATION

UNDER ACT 2, 1995
PREAMBLE 1


Acknowledgment of Notices of Intent to Remediate Submitted under the Land Recycling and Environmental Remediation Standards Act (35 P. S. §§ 6026.101—6026.907)

 Sections 302—305 of the Land Recycling and Environmental Remediation Standards Act (act) (35 P. S. §§ 6026.302—6026.305) require the Department to publish in the Pennsylvania Bulletin an acknowledgment noting receipt of Notices of Intent to Remediate. An acknowledgment of the receipt of a Notice of Intent to Remediate is used to identify a site where a person proposes to, or has been required to, respond to a release of a regulated substance at a site. A person intending to use the background standard, Statewide health standard, the site-specific standard or intend to remediate a site as a special industrial area shall file a Notice of Intent to Remediate with the Department. A Notice of Intent to Remediate filed with the Department provides a brief description of the location of the site, a list of known or suspected contaminants at the site, the proposed remediation measures for the site and a description of the intended future use of the site. A person who demonstrates attainment of one or a combination of cleanup standards or receives approval of a special industrial area remediation identified under the act will be relieved of further liability for the remediation of the site for contamination identified in reports submitted to and approved by the Department. Furthermore, the person shall not be subject to citizen suits or other contribution actions brought by responsible persons not participating in the remediation.

 Under sections 304(n)(1)(ii) and 305(c)(2) of the act, there is a 30-day public and municipal comment period for sites proposed for remediation using a site-specific standard, in whole or in part, and for sites remediated as a special industrial area. This period begins when a summary of the Notice of Intent to Remediate is published in a newspaper of general circulation in the area of the site. For the following site, proposed for remediation to a site-specific standard or as a special industrial area, the municipality, within which the site is located, may request to be involved in the development of the remediation and reuse plans for the site if the request is made within 30 days of the date specified as follows. During this comment period, the municipality may request that the person identified as the remediator of the site develop and implement a public involvement plan. Requests to be involved and comments should be directed to the remediator of the site.

 For further information concerning the content of a Notice of Intent to Remediate, contact the environmental cleanup program manager in the Department regional office listed before the notice. If information concerning this acknowledgment is required in an alternative form, contact the community relations coordinator at the appropriate regional office. TDD users may telephone the Department through the AT&T Relay Service at (800) 654-5984.

 The Department has received the following Notices of Intent to Remediate:

Northeast Region: Eric Supey, Environmental Cleanup and Brownfields Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915.

Allentown School District Administration Building Gravel Parking Area, 1301 Sumner Avenue, Allentown City, Lehigh County, Sean Cheluis, SSM Group, Inc., has submitted a Notice of Intent to Remediate on behalf of his client, Robert Sperling, Jr., Director of Facilities Services, Allentown School District, 1301 Sumner Avenue, Allentown, PA 18102, concerning the remediation of soil found to have been impacted by off-road diesel fuel when a tank was emptied of its contents. The applicant proposes to remediate the site to meet the residential Statewide Health Standards for soil. The intended future use of the site is residential. A summary of the Notice of Intent to remediate was published in The Morning Call on April 15, 2013.

Southcentral Region: Environmental Cleanup and Brownfields Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.

757 Hickory Road Farm House, Penn Township, Lancaster County. GCI Environmental Services, 1250 East King Street, Lancaster, PA 17602, on behalf of Pleasant View Retirement Community, 544 North Penryn Road, Manheim, PA 17545, submitted a Notice of Intent to Remediate soils and groundwater contaminated with No. 2 fuel oil from an above ground storage tank. The proposed cleanup standard for the site is a combination of Residential Statewide Health and Site-Specific standards. The Notice of Intent to Remediate was published in the Intelligencer Journal-Lancaster New Era on April 24, 2013.

MUNICIPAL WASTE GENERAL PERMIT


Application(s) Received Under the Solid Waste Management Act (35 P. S. §§ 6018.101—6018.1003); the Municipal Waste Planning, Recycling and Waste Reduction Act (53 P. S. §§ 4000.101—4000.1904); and Municipal Waste Regulations for a General Permit to Operate Municipal Waste Processing Facilities and the Beneficial Use of Municipal Waste.

Central Office: Division of Municipal and Residual Waste, Rachel Carson State Office Building, 14th Floor, 400 Market Street, Harrisburg, PA 17106-9170.

General Permit Application Number WMGM049. New Castle Sanitation Authority, Lawrence County, 110 East Washington Street, New Castle, PA 16101. The application is for the beneficial use of reclaimed water, consisting of treated municipal wastewater, for cooling purposes and as a substitute for industrial process water at an electric generation facility. The reclaimed water in the application is generated at the City of New Castle wastewater treatment plant, Lawrence County. The electric generation facility identified in the application where the reclaimed water will be beneficially used is the Hickory Run Energy Station in North Beaver Township, Lawrence County. Hickory Run Energy Station (HRES) in North Beaver Township, Lawrence County. HRES has been issued an NPDES permit (Permit No. PA0272591) for the discharge of the excess municipal wastewater not beneficially used at the electric generation facility. The application was determined to be administratively complete on April 16, 2013.

 Written comments concerning the application should be directed to Scott E. Walters, Chief, Permits Section, Division of Municipal and Residual Waste, Bureau of Waste Management, P. O. Box 69170, Harrisburg, PA 17106-9170. TDD users may contact the Department through the Pennsylvania Relay service, (800) 654-5984. Comments may also be submitted via e-mail at ra-epbenuseall@pa.gov. When submitting comment via e-mail, place ''Comments on General Permit Number WMGM049'' in the subject line. Faxed comments will not be accepted. Public comments must be submitted within 60 days of this notice and may recommend revisions to, and approval or denial of the application. For more information, contact the Division of Municipal and Residual Waste at 717-787-7381.

DETERMINATION FOR APPLICABILITY FOR MUNICIPAL WASTE GENERAL PERMITS


Application(s) for Determination of Applicability for General Permit received. Under the Solid Waste Management Act; the Municipal Waste Planning, Recycling and Waste Reduction Act; and Municipal Waste Regulations for a General Permit to Operate Municipal Waste Processing Facilities and/or the Beneficial Use of Municipal Waste.

Southwest Region: Regional Solid Waste Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

General Permit No. WMGR028SW003. Applicant—Lindy Paving, Inc., 2340 2nd Ave., Pittsburgh, PA 15219. Facility—1981 Rt. 119 South, Homer City, PA 15748. A residual waste general permit for the beneficial use of baghouse fines and/or scrubber pond precipitates, generated by hot-mix asphalt plants, for use as: (i) an aggregate in roadway construction, (ii) a soil additive, (iii) a soil conditioner, or (iv) a component or ingredient in the manufacturing of construction products, in Center Township, Indiana County, was deemed administratively complete in the Regional Office on May 7, 2013.

 Persons interested in reviewing the general permit or the application may contact the Department of Environmental Protection, Regional Files, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, 412-442-4000. TDD users may contact the Department through the Pennsylvania Relay Service, (800) 654-5984.

AIR QUALITY

PLAN APPROVAL AND OPERATING PERMIT APPLICATIONS NEW SOURCES AND MODIFICATIONS

 The Department has developed an ''integrated'' plan approval, State Operating Permit and Title V Operating Permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the public. This approach allows the owner or operator of a facility to complete and submit permitting documents relevant to its application one time, affords an opportunity for public input and provides for sequential issuance of the necessary permits.

 The Department received applications for Plan Approvals or Operating Permits from the following facilities.

 Copies of these applications, subsequently prepared draft permits, review summaries and other support materials are available for review in the regional office listed before the applications. Persons interested in reviewing the application files should contact the appropriate regional office to schedule appointments.

 Persons wishing to receive a copy of a proposed Plan Approval or Operating Permit shall indicate interests to the Department regional office within 30 days of the date of this notice and shall file protests or comments on a proposed Plan Approval or Operating Permit within 30 days of the Department providing a copy of the proposed documents to persons or within 30 days of its publication in the Pennsylvania Bulletin, whichever comes first. Interested persons may also request that hearings be held concerning a proposed Plan Approval or Operating Permit. A comment or protest filed with the Department regional office shall include a concise statement of the objections to the issuance of the Plan Approval or Operating Permit and relevant facts which serve as the basis for the objections. If the Department schedules a hearing, a notice will be published in the Pennsylvania Bulletin at least 30 days prior the date of the hearing.

 Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

 Final Plan Approvals and Operating Permits will contain terms and conditions to ensure that the source is constructed and operating in compliance with applicable requirements in 25 Pa. Code Chapters 121—143, the Federal Clean Air Act (42 U.S.C.A. §§ 7401—7671q) and regulations adopted under the Federal Clean Air Act.


Intent to Issue Plan Approvals and Intent to Issue or Amend Operating Permits under the Air Pollution Control Act (35 P. S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B. These actions may include the administrative amendments of an associated operating permit.

Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401

Contact: Sachin Shankar, New Source Review Chief—Telephone: 484-250-5920

46-0005AN: Merck, Sharp & Dohme, Corp. (770 Sunmeytown Pike, West Point, PA 19486-0004) for the redaction and clarification of RACT related condition in the Title V operating permit in Pottstown Borough, Montgomery County. The overall air emissions associated with these changes will result in no change in actual or potential emissions from this facility. This project does not trigger applicability toward PADEP's NSR regulations or the federal PSD regulations. The plan approval will include monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

15-0110B: Pepperidge Farm, Inc. (421 Boot Road, Downingtown, PA 19335) for installation and operation of two (2) 25-ton flour Use Bins with associated bin vent filters at their facility in Downingtown Borough, Chester County.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481

Contact: Edward Orris, New Source Review Chief—Telephone: 814-332-6636

25-1038A: Lord Corp. (2455 Robison Road, Erie, PA 16509) for the proposed relocation and combination of their Erie operations in Summit Township, Erie County. Operations from the West 12th Street manufacturing plant and the Grandview Avenue corporate offices will relocate to the new facility. This is a State Only facility. The public notice is required for sources required to obtain a Plan Approval in accordance with 25 Pa. Code § 127.44. This plan approval will, in accordance with 25 Pa. Code § 127.450 or § 127.505, be incorporated into the State Only operating permit at a later date.

 The relocation will involve moving existing sources to the new facility and constructing new sources to take the place of existing sources at the manufacturing plant. This project will result in facility emissions of 24.5 tpy for VOC, 24 tpy for total HAPs, and 9.9 tpy for single HAP. This Plan Approval will contain emission restriction, recordkeeping, work practice standard and additional requirement conditions, which will satisfy the requirements of 25 Pa. Code § 127.12b (pertaining to plan approval terms and conditions) and will demonstrate BAT for the source including, but are not limited to, the following:

 Site Conditions:

 • VOC emissions from the facility (combined) shall not exceed 24.5 tpy based on a 12-month rolling period.

 • Total HAP emissions from the facility (combined) shall not exceed 24.0 tpy based on a 12-month rolling period.

 • Single HAP emissions from the facility (combined) shall not exceed 9.9 tpy based on a 12-month rolling period.

 Spray Booths:

 • VOC emissions from all coating/adhesive booths shall not exceed 23.0 tpy based on a 12-month rolling period.

 • Total HAP emissions from all coating/adhesive booths shall not exceed 19.6 tpy based on a 12-month rolling period.

 • Subject to 25 Pa. Code § 129.52

 • The permittee shall maintain a record of all preventive maintenance inspections of the source. These records shall include, at a minimum, the dates of the inspections, the name of the person performing the inspection, any problems or defects identified, any actions taken to correct the problems or defects, and any routine maintenance performed.

 • The permittee shall record the following operational data from the source/control device (these records may be done with strip charts recorders, data acquisition systems, or manual log entries):

 • Pressure drop across filters—daily defined as once per calendar day

 • A facility, regardless of the facility's annual emission rate, which contains surface coating processes shall maintain records sufficient to demonstrate compliance with this section. At a minimum, a facility shall maintain records of:

 • The following parameters for each coating, thinner and other component as supplied:

 • The coating, thinner or component name and identification number.

 • The volume used.

 • The mix ratio.

 • The density or specific gravity.

 • The weight percent of total volatiles, water, solids and exempt solvents.

 • The volume percent of solids for Table I surface coating process categories 1-10.

 • The VOC content of each coating, thinner and other component as supplied.

 • The VOC content of each as applied coating. To meet the daily requirement in 25 Pa. Code § 129.52, the facility shall determine the VOC content of each as applied coating by determining the maximum amount of solvent that can be added to each coating while still meeting the Table 1 limits and never exceeding that amount of solvent.

 • The permittee shall record the following:

 • Inventory reports of VOC and HAP containing materials

 • Usage reports of VOC and HAP containing materials

 • Waste shipments of VOC and HAP containing materials

 • Waste analysis of VOC and HAP containing materials

 • Computerized emissions tracking model. Using the computerized emissions tracking model, the records shall be complied on a monthly basis to determine the total VOC, total HAP, and individual HAP emissions for that month. These monthly totals shall be added to the monthly totals for the previous eleven (11) months to determine the twelve (12) month rolling totals for each type of pollutant.

 • The permittee shall maintain the following records for demonstrating compliance:

 • A list of each adhesive, sealant, adhesive primer, sealant primer, surface preparation solvent and cleanup solvent product in use and in storage.

 • A data sheet or material list which provides the product name, manufacturer identification and use or material application for each product included on the list required under paragraph (1).

 • The VOC content of each product on the list required under paragraph (1), as supplied.

 • Catalysts, reducers or other components used and the mix ratio.

 • The VOC content or vapor pressure of each product on the list required by paragraph (1), as applied, if solvent or other VOC is added to the product before application.

 • The volume purchased or produced of each product on the list required under paragraph (1).

 • The monthly volume used or applied as part of a manufacturing process at the facility of each product on the list required under paragraph (1).

 • The permittee shall maintain and operate the source in accordance with the manufacturer's specifications and in accordance with good air pollution control practices.

 • The facility shall comply with the following BAT requirements:

 • All spray guns used in these booths shall be of the high volume, low pressure (HVLP) type, or a type equivalent to or better than HVLP in terms of transfer efficiency.

 • All spray guns shall be cleaned as needed or before allowing to set idle for extended periods. All spray guns used in these booths shall always be cleaned with enclosed spray gun cleaning equipment designed specifically for this purpose.

 • The system shall be checked daily for leaks of lines and guns.

 • Good housekeeping practices shall be followed at all times, including but not limited to, any spills of adhesive, paint and solvent being cleaned up immediately, and containers of adhesive, paint and solvent kept closed when not in use.

 • The permittee shall store or dispose of all absorbent materials, including cloth or paper, which are moistened with adhesives, sealants, primers, surface preparation solvents or cleanup solvents subject to this section, in nonabsorbent containers at the facility that are kept closed except when placing materials in or removing materials from the container.

 Metal Tanks:

 • The permittee shall record the following operational data from the source/control device (these records may be done with strip charts recorders, data acquisition systems, or manual log entries):

 • Pressure drop across filters—daily defined as once per calendar day

 • pH—daily defined as once per calendar day

 • Water flow—daily defined as once per calendar day

 • The permittee shall maintain and operate the source in accordance with the manufacturer's specifications and in accordance with good air pollution control practices.

 Parts Washers:

 • Subject to 25 Pa. Code § 129.63

 Research & Development:

 • The R&D activities shall not exceed annual emission rates of the following:

 • CO: 20 tpy based on a consecutive 12-month period

 • Lead: 0.12 tpy based on a consecutive 12-month period

 • PM10: 3 tpy based on a consecutive 12-month period

 • SOx: 8 tpy based on a consecutive 12-month period

 • VOC: 8 tpy based on a consecutive 12-month period

 • NOx: 10 tpy based on a consecutive 12-month period

 • Single HAP: 1 tpy based on a consecutive 12-month period

 • Total HAPs: 2.5 tpy based on a consecutive 12-month period

 In accordance with 25 Pa. Code § 127.44(f)(1), all the pertinent documents regarding this application (applications, review memos, and draft approvals) are also available for review from 8:00 a.m. to 4:00 p.m. at the Meadville Regional DEP office (Air Quality). Appointments for scheduling a review must be made by calling the DEP at (814) 332-6340.

 In accordance with 25 Pa. Code § 127.44(f)(2), a 30-day comment period, from the date of publication, will exist for the submission of comments. Any person(s) wishing to provide DEP with additional information, which they believe should be considered prior to the issuance of this permit, may submit the information to Regional Air Quality Program Manager, Pennsylvania Department of Environmental Protection, 230 Chestnut Street, Mead-ville, PA 16335-3494 and must contain the name, address and telephone number of the person submitting the comments, identification of the proposed plan approval [25-1038A] and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A public hearing may be held, if the Department of Environmental Protection, in its discretion, decides that such a hearing is warranted based on the comments received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, where DEP determines such notification is sufficient. Written comments or requests for a public hearing should be directed to Regional Air Quality Program Manager, 230 Chestnut St., Meadville, PA 16335; Phone (814) 332-6940.

 In accordance with 25 Pa. Code § 127.45, a person may oppose the proposed plan approval by filing a written protest with the Department's Northwest Region Air Quality Program Manager.

 If a plan approval has not undergone the above public notice process, the change to an operating permit must be treated as a significant modification. In these situations the Department should follow the procedures described in §§ 127.421 to 127.431 for state only operating permits or §§ 127.521 to 127.524 for Title V operating permits.

OPERATING PERMITS


Intent to Issue Title V Operating Permits under the Air Pollution Control Act and 25 Pa. Code Chapter 127, Subchapter G.

Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401

Contact: Janine Tulloch-Reid, Facilities Permitting Chief—Telephone: 484-250-5920

23-00021: Congoleum Corp. (4401 Ridge Road, Delaware, PA 19061) for renewal of the Title V Operating Permit in Trainer Borough, Delaware County. The initial permit was issued on March 5, 2002. The facility manufactures patterned vinyl flooring, by employing rotogravure presses and coating lines to engrave images and apply protective/decorative layers on substrate. As a result of potential emissions of VOCs and NOx, the facility is a major stationary source as defined in the Clean Air Act, and is therefore subject to the Title V permitting requirements adopted in 25 Pa. Code Chapter 127, Subpart G. This Title V Renewal does not reflect any change in air emissions from the facility. The renewed permit contains monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

46-00039: Exelon Generation Co.—Moser Generating Station (Moser and Yost Streets, Pottstown, PA 19464) for operation of an electrical power peak generating station in Lower Pottsgrove Township, Montgomery County. As a result of potential emissions of NOx and SOx, the Moser facility is a major stationary source, as defined in the Clean Air Act. The renewal contains applicable monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

46-00032: SPS Technologies, Inc. (SPS), (301 Highland Avenue, Jenkintown, PA 19046) for a major aerospace parts manufacturing facility located at Highland Avenue Abington Township, Montgomery County. This action is a renewal of the facility's Title V Operating Permit originally issued on October 18, 2007. There have been several amendments of this TVOP since its original issuance. The renewal does not allow any new changes other than updating of source inventory and changes of minor significance. The operation is subjected to federal NESHAPS and NSPS regulations. The permit includes monitoring, recordkeeping and reporting requirements designed to keep the plant operating within all applicable air quality requirements.

Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110

Contact: Thomas J. Hanlon, Facility Permitting Chief—Telephone: 717-705-4862 or William Weaver, Program Manager—Telephone: 717-705-4702.

21-05002: PPG Industries, Inc. (400 Park Drive, Carlisle, PA 17015) for operation of their flat glass manufacturing facility in South Middleton Township, Cumberland County.

 In accordance with 25 Pa. Code § 127.463, the Department has received an application and intends to issue a revised Title V Operating Permit for the abovementioned facility. This will be a significant modification to the permit.

 Recent regulations under Section 129 reduce allowable nitrogen oxides (NOx) emission levels and establish detailed monitoring, recordkeeping and reporting requirements for the facility's two glass melting furnaces. The company previously requested an alternative compliance schedule for the No. 1 melting furnace in accordance with Section 129.304(c) which expressly provides for such measures. A petition for an alternative emission limitation for Glass Furnace No. 1 has been submitted to amend the previous requirements for that furnace based upon detailed cost figures now available for the facility. The Title V permit will be modified to approve this petition. This include the deletion of certain conditions related to the initial petition, the addition of conditions related to the new petition, and the revision of certain RACT-related conditions to ensure consistency with the SIP.

 Facility actual emissions for calendar year 2012 included 2,968 tons of NOx, 705 tons of sulfur oxides and 261 tons of particulate matter.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A 30-day comment period, from the date of publication of this notice in the Pennsylvania Bulletin, will exist for the submission of comments or protests.

 William R. Weaver, Air Quality Program Manager, may be contacted at 717-705-4702, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments or protests.

Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

Contact: Barbara Hatch, Facilities Permitting Chief—Telephone: 412-442-4174

65-000137: Allegheny Ludlum, LLC. /Vandergrift (100 River Road, Brackenridge, PA 15014) In accordance with 25 Pa. Code §§ 127.424, 127.425 and 127.521, the Department of Environmental Protection (DEP) is providing notice that it intends to issue a renewal Title V Operating Permit (TVOP-65-000137) to Vandergrift facility to authorize the continued operation of a stainless steel sheets, strips and plates finishing operations facility located in Vandergrift Boro., Westmoreland County. The name and address of the applicant is Allegheny Ludlum, LLC./Vandergrift, 100 River Road, Bracken-ridge, PA 15014.

 The finishing operations at this facility primarily include two annealing and pickling lines, two boilers and two cold reduction mills, shearing, abrasive cutting and machining and other miscellaneous equipment associated with this type of operations. The facility has the potential to emit 0.6 ton per year of SO2, 331.8 tons per year of NOx, 80.0 tons per year of PM/PM10 and 20.3 tons per year of VOCs. NOx emission is above its respective major facility emission threshold. The proposed TVOP renewal contains conditions relating to monitoring, recordkeeping and work practice standards.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public inspection during normal business hours at DEP, 400 Waterfront Drive, Pittsburgh, PA 15222. Appointments for scheduling a file review may be made by calling 412-442-4286. Any person wishing to provide DEP with additional information that they believe should be considered prior to the issuance of this permit may submit the information to DEP at the address shown above. A 30-day comment period, from the date of this publication, will exist for the submission of comments. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit (specify TVOP-65-000137) and concise statements regarding the relevancy of the information in the proposed permit or objections to issuance of the permit.

 A public hearing may be held, if DEP, in its discretion, decides that such a hearing is warranted based on the information received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or by the Pennsylvania Bulletin, or by telephone, where DEP determines such notification by telephone is sufficient. Written comments or requests for a public hearing should be directed to Barbara Hatch, Air Quality Environmental Engineer Manager, DEP, Southwest Regional Office, 400 Waterfront Drive, Pittsburgh, PA 15222, (412) 442-5226.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481

Contact: Matthew Williams, Facilities Permitting Chief—Telephone: 814-332-6131

37-00023: Genon Power Midwest LP—New Castle Power Plant (PO Box 325, West Pittsburgh, PA 16160) to modify a Title V Operating Permit for their New Castle Power Plant in Taylor Township, Lawrence County.

 The modification is in accordance with 25 Pa. Code § 127.463. The permit expires April 30, 2017. Genon Power New Castle Power Plant is a major facility and is subject to the Title V Operating Permit requirements adopted in 25 Pa. Code Chapter 127, Subchapters F and G. The facility is subject to multiple State and Federal Regulations. The modification involves the incorporation of the requirements of 40 CFR 63 Subpart DDDDD—National Emission Standards for Hazardous Air Pollutants (NESHAPs) for Major Sources: Industrial, Commercial, and Institutional Boilers and Process Heaters. These requirements became effective April 1, 2013. The Department is required to revise the permit because the expiration date of the current permit is more than 3 years from the effective date of Subpart DDDDD. The facility has an auxiliary boiler used for building heat and freeze protection. Source 030 is a Clayton Industries boiler (model EO-204-1) rated at 8.2 mmbtu/hr. The boiler is fueled with #2 oil. This boiler is subject to the tune-up and energy assessment work practice standards of Subpart DDDDD. Minor changes were also made to the permit to reflect the amended language of 40 CFR 63 Subpart ZZZZ—NESHAPs for Stationary Reciprocating Internal Combustion Engines.

 Copies of the Department's analysis and other documents used in the evaluation of the application are available for public inspection during normal business hours at the Department of Environmental Protection, 230 Chestnut Street, Meadville, PA 16335.

 Any person wishing to provide the Department of Environmental Protection with additional information they believe should be considered prior to the issuance of this permit may submit the information to the Department at the address shown above. A 30-day comment period, from the date of this publication, will exist for the submission of comments. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit (specify Permit # TV 37-00023) and concise statements regarding the relevancy of the information in the proposed permit or objections to issuance of the permit.

 Written comments should be directed to Mr. John F. Guth, Program Manager, Air Quality, Department of Environmental Protection, Northwest Region, 230 Chestnut Street, Meadville, PA 16335. For additional information concerning the permit or the issuance procedure, contact Mr. Matthew M. Williams, Facilities Section Chief, Air Quality Program, at the same address or phone at (814) 332-6131.


Intent to Issue Operating Permits under the Air Pollution Control Act and 25 Pa. Code Chapter 127, Subchapter F.

Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19428

Contact: Janine Tulloch-Reid, Facilities Permitting Chief—Telephone: 484-250-5920

15-00086: Griffin Industries LLC—dba Bakery Feeds (97 Westbrook Drive, Honey Brook, PA 19344) for an animal feed processing facility in Honey Brook Township, Chester County. The renewal permit is for a non-Title V (State only) facility. Operations at the facility include drying of waste bakery products, separation of the product and packaging and blending of the recycled bakery product with an animal feed ingredient. A regenerative thermal oxidizer (RTO) controls VOC emissions from the dryer with a minimum of 98% efficiency. Natural gas, non-chemically treated wood, and packaging waste are approved fuels for the biomass burner with the rotary dryer. No emissions increases above previously approved levels are authorized with the renewal. The operating permit will include monitoring, testing, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

23-00072: Action Supply Co., Inc. (1401 Calcon Hook Road, Sharon Hill, PA 19079) for a renewal of a State Only Operating Permit in Darby Township, Delaware County. The facility operates three ready-mix concrete plants and a concrete recycling plant consisting of two crushers and a screener. The recycling plant is powered by three diesel-fired engines. While there is no restriction in operating hours for the concrete plants, the recycling plant is limited to a 2,000 hour per year limitation. There have been no source changes or modifications to any plant equipment since this operating permit was last issued; however new requirements from the Federal MACT Standards of Subpart ZZZZ, which are applicable to the diesel-fired engines, are being included in the operating permit. Also incorporated in the operating permit and in accordance with EPA standards on the regulation of fuels and fuel additives, all non-road diesel fuel is subject to a maximum sulfur content of 15 ppm per gallon standard. Action Supply Co., Inc. is a synthetic minor facility. Monitoring, record keeping and reporting requirements have been added to the permit to address applicable limitations.

46-00240: JBS Souderton, Inc. (249 Allentown Rd, Souderton, PA 18964) for an animal slaughtering, meat processing and meat packing plant, synthetic minor facility in Franconia Township, Montgomery County. This action is a renewal of the facility's State Only Operating Permit originally issued on May 22, 2007. The renewal does not allow any new changes other than updating of source inventory and changes of minor significance. The operation is subjected to federal NESHAPS and NSPS regulations. The permit includes monitoring, recordkeeping and reporting requirements designed to keep the plant operating within all applicable air quality requirements.

46-00147: Chemalloy Company, Inc. (P. O. Box 350 Bryn Mawr, PA 19010) for a primary metal products manufacturing minor facility at 1301 Conshohocken Rd, Conshohocken, PA 19428, Plymouth Township, Montgomery County. This action is a renewal of the facility's State Only Operating Permit originally issued on December 13, 2007. The renewal does not allow any new changes other than updating of source inventory and changes of minor significance. The permit includes monitoring, recordkeeping and reporting requirements designed to keep the plant operating within all applicable air quality requirements.

09-00135: Met-Pro Corp—Fybroc Division (700 Emlen Way, Telford, PA 18969) for renewal of a State Only Operating Permit for a pumps and pumping equipment manufacturing facility in Telford Borough, Bucks County. The facility is a natural minor facility for VOC and HAP emissions. This facility is limited to 3.5 tons per year of VOC/HAP emissions. This Operating Permit renewal includes emission restrictions, monitoring, recordkeeping and work practice requirements designed to ensure this facility complies with all applicable air quality regulations.

Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711-0790

Contact: Ray Kempa, New Source Review Chief—Telephone: 570-826-2507

40-00063: Kappa Graphics, LP (50 Rock Street, Pittston, PA 18640-3028) for operation of a lithographic printing operation in Hughestown Borough, Luzerne County. The sources consist of four (4) presses and a thermal oxidizer for emission control of volatile organic compounds (VOC's). This is a renewal of a State-Only Operating Permit. The State-Only operating permit includes emissions, work practice standards and testing, monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

48-00055: Philadelphia Archdiocese—Mary Immaculate Center (300 Cherryville Road, Northampton, PA 18067-9548) for operation of three (3) boiler at the facility located in Lehigh Township, Northampton County. The boilers are fired on #4 or lighter fuel oil. This is a renewal of a State-Only Operating Permit. The State-Only operating permit includes emissions, work practice standards and testing, monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

Southcentral Region: Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110

Contact: Thomas J. Hanlon, Facility Permitting Chief—Telephone: 717-705-4862 or William Weaver, Program Manager—Telephone: 717-705-4702.

67-03094: Rocher, Inc.—d/b/a Del-Wood Kitchens, Inc. (1856 Dubs Church Road, Hanover, PA 17331) for operation of a wood kitchen cabinet manufacturing in Manheim Township, York County.

 In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit renewal for the abovemen-tioned facility.

 Actual 2011 emissions at the facility are estimated to be approximately 5.4 tons of VOCs and 0.5 ton of HAPs. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. Among other items, the conditions include provisions derived from 40 CFR Part 63, Subpart JJJJJJ—National Emission Standards for Hazardous Air Pollutants for Industrial, Commercial, and Institutional Boilers Area Sources.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office, at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, or may request a public hearing, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A 30-day comment period, from the date of publication of this notice in the Pennsylvania Bulletin, will exist for the submission of comments, protests or requests for a public hearing.

 Mr. William Weaver, Air Quality Program Manager, may be contacted at 717-705-4702, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments, protests or requests for a public hearing.

22-05041: The Hershey Company (1033 Old West Chocolate Avenue, Hershey PA 17033) for the West Chocolate Manufacturing plant in Derry Township, Dauphin County.

 In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit renewal for the abovemen-tioned facility.

 The facility's annual emission are approximately 12.6 tons of CO, 7.4 tons of PM10, 4.8 tons of NOx, 1.2 tons of VOCs, and 0.11 ton of SOx. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. Among other items, the facility's boilers are subject to 40 CFR Part 60, Subpart Dc requirements, and several of the plant's emergency generators and fire pump engines are subject to 40 CFR Part 60, Subpart IIII & 40 CFR Part 63, Subpart ZZZZ requirements.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office, at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, or may request a public hearing, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A 30-day comment period, from the date of publication of this notice in the Pennsylvania Bulletin, will exist for the submission of comments, protests or requests for a public hearing.

 Thomas J. Hanlon, Facilities Permitting Chief, may be contacted at (717) 705-4862, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments or protests.

50-03004: Tuscarora Hardwoods, Inc. (2240 Sher-mans Valley Road, Elliotsburg, PA 17024) for operation of a lumber processing facility in Spring Township, Perry County.

 In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit renewal for the abovemen-tioned facility. The estimated potential boiler emissions are: 24 tons of PM per year; 72 tons of CO per year; 26.4 tons of NOx per year; 3 tons of SOx per year; and 2.61 tons of VOCs per year. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations.

 The facility includes equipment subject to 40 CFR, Part 60, Subpart JJJJJJ—National Emission Standards for Area Sources: Industrial/Commercial/Institutional Boilers and 40 CFR, Part 60, Subpart Dc—Standards of Performance for Small Industrial-Commercial-Institutional Steam Generating Units.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office, at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, or may request a public hearing, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A 30-day comment period, from the date of publication of this notice in the Pennsylvania Bulletin, will exist for the submission of comments, protests or requests for a public hearing.

 Mr. Gary Helsel, Acting Chief, New Source Review Section, may be contacted at 814-949-7935, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments, protests or requests for a public hearing.

36-05086: Donsco, Inc. (100 South Jacobs Street, Mount Joy, PA 17552) for the foundry operations in Mount Joy Borough, Lancaster County.

 In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit for the abovementioned facility.

 The facility's melt operations are subject to the area source requirements of 40 CFR Part 63, Subpart ZZZZZ. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. The facility has potential emissions of 43.1 tons of PM10 and 13.8 tons of VOCs.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office, at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, or may request a public hearing, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above and a concise statement regarding the relevancy of the information or objections to the issuance of the permit identification of the proposed permit by the permit number listed above.

 A 30-day comment period, from the date of publication of this notice in the Pennsylvania Bulletin, will exist for the submission of comments or protests.

 Thomas J. Hanlon, Facilities Permitting Chief, may be contacted at (717) 705-4862, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments or protests.

22-03036: Alfa-Laval, Inc. (300 Chestnut Street, Lykens, PA 17048) for the heat exchanger manufacturing plant in Lykens Borough, Dauphin County.

 In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit for the abovementioned facility.

 The facility's boiler is subject to 40 CFR Part 63, Subpart JJJJJJ and the facility's abrasive blasting, machining operations, and welding operations are all subject to 40 CFR Part 63, Subpart XXXXXX. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. The facility has the potential to emit 3.16 tons of CO, 3.77 tons of NOx, 8.59 tons of PM10, 5.23 tons of VOCs, and 0.02 ton of SOx.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office, at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, or may request a public hearing, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above and a concise statement regarding the relevancy of the information or objections to the issuance of the permit identification of the proposed permit by the permit number listed above.

 A 30-day comment period, from the date of publication of this notice in the Pennsylvania Bulletin, will exist for the submission of comments or protests.

 Thomas J. Hanlon, Facilities Permitting Chief, may be contacted at (717) 705-4862, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments or protests.

21-05051: PA State System of Higher Education—Shippensburg University (1871 Old Main Drive, Shippensburg, PA 17257-2299) for boilers and emergency generators in Shippensburg Borough, Cumberland County. This is a renewal of their State-Only Operating Permit issued in October 2007.

 In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit for the abovementioned facility. The primary emissions from the facility are SOx, NOx, CO, and particulate matter. The facility's actual 2011 annual emissions are: SOx 68 tons, NOx 29 tons, PM10 23 tons, CO 2 tons, and VOC 0.3 ton. The boilers and emergency generator engines are subject to the area source MACTs 40 CFR Part 63, Subparts JJJJJJ and ZZZZ respectively.

 The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping, and reporting requirements to ensure the facility complies with the applicable air quality regulations.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office, at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, or may request a public hearing, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above, and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 Mr. Gary Helsel, Acting Chief, New Source Review Section, may be contacted at 814-949-7935, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments or protests.

38-05031: Supreme Mid-Atlantic Corp. (411 Jonestown Road, P. O. Box 779, Jonestown, PA 17038) for the operation of a truck and truck parts coating operation facility in Union Township, Lebanon County.

 In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit for the abovementioned facility. Actual VOC emissions are estimated to be around 8.0 tpy. The Operating Permit will include emission limits and work practice standards along with testing, monitoring, record keeping and reporting requirements to ensure the facility complies with all applicable air quality regulations.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the PA DEP Southcentral Regional Office, at 909 Elmerton Avenue, Harrisburg, PA 17110.

 A person may oppose the proposed operating permit, or may provide the Department with additional information to consider in its review, or may request a public hearing, by filing a written protest with the Department at the address listed above. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit by the permit number listed above and a concise statement regarding the relevancy of the information or objections to the issuance of the permit identification of the proposed permit by the permit number listed above.

 A 30-day comment period, from the date of publication of this notice in the Pennsylvania Bulletin, will exist for the submission of comments or protests.

 Thomas J. Hanlon, Facilities Permitting Chief, may be contacted at (717) 705-4862, or at PA DEP Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, for additional information or for the submission of comments or protests.

Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

Contact: Barbara Hatch, Facilities Permitting Chief—Telephone: 412-442-4174

65-00064: Specialty Seal Group, Inc.—Latrobe Plant (1001 Lloyd Ave. Latrobe, PA 15650) for operation of electronic components having a hermetic seal in the Unity Township, Westmoreland County.

 In accordance with 25 Pa Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) has received an application and intends to issue an Air Quality Operating Permit for the above mentioned facility.

 The subject facility consists of 12 electric furnaces, ammonia storage tank, nickel plating line and an electroless nickel plating line. The facility has the potential to emit 0.02 tpy NOx, 0.18 tpy CO, 0.297 tpy VOC, and 0.761 tpy HAPs. The facility is required to conduct a weekly survey of the facility during daylight hours while the facility is operating to ensure compliance with the visible emission, fugitive emission and malodor restrictions. Records of the weekly survey performed must be recorded. The proposed authorization is subject to State and Federal Regulations. The permit includes operation requirements, monitoring requirements, and recordkeeping requirements.

 Those who wish to provide the Department with additional written information that they believe should be considered prior to the issuance of the Plan Approval may submit the information to Sheila Shaffer, Pennsylvania Department of Environmental Protection, 400 Waterfront Drive, Pittsburgh, PA, 15222. Written comments must contain the name, address and telephone number of the person submitting the comments, identification of the proposed Operating Permit (65-00064) and concise statements regarding the relevancy of the information or objections to issuance of the Operating Permit.

 A public hearing may be held, if the Department, in its discretion, decides that such a hearing is warranted based on the information received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or by the Pennsylvania Bulletin, or by telephone, where the Department determines such notification by telephone is sufficient. Written comments or requests for a public hearing should be directed to Mr. Mark Wayner, Regional Air Quality Program Manager, Department of Environmental Protection, Southwest Region, 400 Waterfront Drive, Pittsburgh, PA 15222. For additional information concerning the permit or the issuance procedure, contact Ms. Sheila Shaffer, Air Quality Engineering Specialist, at the same address or phone at (412) 442-5227.

 All comments must be received prior to the close of business 30 days after the date of this publication.

04-00734: Sardello, Inc. (1000 Corporation Drive, Aliquippa, PA 15001) In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) gives notice that they intend to issue a State Only Operating Permit (SOOP) to Sardello, Inc. to authorize the continued operation of their Hopewell Facility located in Hopewell Township, Beaver County.

 This is a remanufacturing plant for equipment such as fuel pumps, fuel injectors, valves, governors & parking brakes as well as non-mechanical metallic components. Processes include thermal and/or abrasive cleaning, painting and coating and testing. Estimated potential emission from this facility is 8.51 tons of VOCs per year which include HAPs and other pollutants of insignificant amount.

 The proposed SOOP contains conditions relating to emission restrictions, monitoring, recordkeeping, reporting and work practice standards.

 Arrangements may be made to review the application at our offices. Those who wish to provide the Department with additional written information that they believe should be considered prior to the issuance of the Operating Permit renewal may written comments to Barbara Hatch, Pennsylvania Department of Environmental Protection, 400 Waterfront Drive, Pittsburgh, PA, 15222, 412-442-5226 (bhatch@pa.gov). A 30-day comment period, from the date of this publication, will exist for the submission of comments. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit (specify OP-04-00734), and concise statements regarding the relevancy of the information in the proposed permit or objections to issuance of the permit.

 A public hearing may be held, if DEP, in its discretion, decides that such a hearing is warranted based on the information received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or by the Pennsylvania Bulletin, or by telephone, where DEP determines such notification by telephone is sufficient. Written comments or requests for a public hearing should be directed to Barbara Hatch at the location identified above.

65-00621: Kennametal Inc. (1008 Club Drive, Johnstown, PA 15905) In accordance with 25 Pa. Code §§ 127.424 and 127.425 the Department of Environmental Protection (DEP) gives notice that they intend to issue a State Only Operating Permit (SOOP) to Kennametal Inc. to authorize the continued operation of their Kingston Plant located in Derry Township, Westmoreland County.

 The facility produces tungsten, tungsten carbide, tungsten titanium carbide powder to make tool and parts for industries. The facility consists of small crushers and screens, blenders, blenders, furnaces and several dust collectors and other equipment associated with this type of industries.

 The facility has the potential to emit up to 28.96 tons per year of total particulate matter (PM), 6.09 tons per year of NOx and other pollutants of insignificant amount. The proposed SOOP contains conditions relating to emission restrictions, monitoring, recordkeeping, reporting and work practice standards.

 Arrangements may be made to review the application at our offices. Those who wish to provide the Department with additional written information that they believe should be considered prior to the issuance of the Operating Permit renewal may written comments to Barbara Hatch, Pennsylvania Department of Environmental Protection, 400 Waterfront Drive, Pittsburgh, PA, 15222, 412-442-5226 (bhatch@pa.gov). A 30-day comment period, from the date of this publication, will exist for the submission of comments. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit (specify OP-65-00621), and concise statements regarding the relevancy of the information in the proposed permit or objections to issuance of the permit.

 A public hearing may be held, if DEP, in its discretion, decides that such a hearing is warranted based on the information received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or by the Pennsylvania Bulletin, or by telephone, where DEP determines such notification by telephone is sufficient. Written comments or requests for a public hearing should be directed to Barbara Hatch at the location identified above.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481

Contact: Matthew M. Williams—Telephone: 814-332-6131

10-00281: II VI, Inc. (375 Saxonburg Boulevard, Saxonburg, PA 16056-9430) for renewal of the operating permit for their facility in Clinton Township, Butler County. The sources at the facility include miscellaneous combustion sources, batch vapor degreaser using a halogenated solvent, chemical vapor deposition units, hydrogen selenide gas production, thins film materials produc-tion, isopropyl alcohol vapor degreasers, batch vapor dryer, and emergency generators. The emergency generators are fueled with low sulfur diesel (15 ppmv). The conditions of the previous plan approval and operating permit were incorporated into the renewal permit. The halogenated solvent vapor degreaser is subject to 40 CFR 63 Subpart T—NESHAP for Halogenated solvent cleaning. The emergency generators are subject to 40 CFR 63 Subpart ZZZZ—NESHAP for Reciprocating Internal Combustion Engine (RICE). Emissions from the facility are less than the major source thresholds. The facility is a Natural Minor.

COAL AND NONCOAL MINING ACTIVITY APPLICATIONS

 Applications under the Surface Mining Conservation and Reclamation Act (52 P. S. §§ 1396.1—1396.19a); the Noncoal Surface Mining Conservation and Reclamation Act (52 P. S. §§ 3301—3326); The Clean Streams Law (35 P. S. §§ 691.1—691.1001); the Coal Refuse Disposal Control Act (52 P. S. §§ 30.51—30.66); and The Bituminous Mine Subsidence and Land Conservation Act (52 P. S. §§ 1406.1—1406.20a). Mining activity permits issued in response to such applications will also address the applicable permitting requirements of the following statutes: the Air Pollution Control Act (35 P. S. §§ 4001—4015); the Dam Safety and Encroachments Act (32 P. S. §§ 693.1—693.27); and the Solid Waste Management Act (35 P. S. §§ 6018.101—6018.1003).

 The following permit applications to conduct mining activities have been received by the Department. A copy of the application is available for inspection at the district mining office indicated before each application. Notices of requests for 401 Water Quality Certifications are included in individual application notices, as noted.

 Written comments or objections, or requests for an informal conference, or a public hearing, as applicable, on a mining permit application and request for Section 401 water quality certification application may be submitted by any person or any officer or head of any Federal, state or local government agency or authority to the Department at the address of the district mining office indicated before each application within 30 days of this publication, or within 30 days after the last publication of the applicant's newspaper advertisement as provided by 25 Pa. Code §§ 77.121—77.123 and 86.31—86.34.

 Written comments or objections regarding a mining permit application should contain the name, address and telephone number of persons submitting comments or objections, application number and a statement of sufficient detail to inform the Department on the basis of comment or objection and relevant facts upon which it is based.

 A request for an informal conference or a public hearing, as applicable, on a mining permit application, as provided by 25 Pa. Code § 77.123 or § 86.34, must contain the name, address and telephone number of the requestor; the application number; a brief summary of the issues to be raised by the requestor at the conference; and a statement whether the requestor desires to have the conference conducted in the locality of the proposed mining activities.

 When an NPDES number is listed, the mining activity permit application was accompanied by an application for an individual NPDES permit. A separate notice will be provided after the draft NPDES permit is prepared.

Coal Applications Received

California District Office: 25 Technology Drive, Coal Center, PA 15423, 724-769-1100

32831602 and NPDES No. PA0214515. General Trade Corporation, (745 Power Plant Road, New Florence, PA 15944-7000). To renew the permit for The Central Preparation Plant in West Wheatfield Township, Indiana County and related NPDES Permit. No additional discharges. The application was considered administratively complete on May 1, 2013. Application received March 12, 2013.

30841316. Consol Pennsylvania Coal Company, LLC, (PO Box J, 1525 Pleasant Grove Road, Claysville, PA 15323). To revise the permit for the Bailey Mine & Prep Plant in Richhill Township, Greene County to install an AMD plant pipeline and sludge injection borehole. Application also includes a request for a Section 401 Water Quality Certification. Surface Acres Proposed 46.0. No additional discharges. The application was considered administratively complete on May 2, 2013. Application received March 12, 2013.

Greensburg District Mining Office: Armbrust Professional Center, 8205 Route 819, Greensburg, PA 15601, 724-925-5500

63050102 and NPDES Permit No. PA0250767. S & K Energy, Inc. (5945 Pudding Stone Lane, Bethel Park, PA 15102). Application received for transfer of permit currently issued to Mulligan Mining, Inc. for continued operation and reclamation of a bituminous surface mining site located in Smith Township, Washington County, affecting 143.9 acres. Receiving streams: unnamed tributaries to Raccoon Run and Raccoon Creek, classified for the following use: warm water fishes. The first downstream potable water supply intake from the point of discharge is greater than ten miles from the proposed site. Transfer application received: April 19, 2013.

63080101 and NPDES Permit No. PA0251381. S & K Energy, Inc. (5945 Pudding Stone Lane, Bethel Park, PA 15102). Application received for transfer of permit currently issued to Mulligan Mining, Inc. for continued operation and reclamation of a bituminous surface mining site located in Smith Township, Washington County, affecting 124.0 acres. Receiving streams: unnamed tributaries to Raccoon Creek and Little Raccoon Creek, classified for the following use: warm water fishes. The first downstream potable water supply intake from the point of discharge is greater than ten miles from the proposed site. Transfer application received: April 19, 2013.

03040101 and NPDES Permit No. PA0250597. AMFIRE Mining Company, LLC (One Energy Place, Latrobe, PA 15650). Renewal application for reclamation only to an existing bituminous surface mine, located in Gilpin Township, Armstrong County, affecting 62.1 acres. Receiving stream: unnamed tributary to Allegheny River, classified for the following use: WWF. The potable water supply with intake within 10 miles downstream from the point of discharge: Freeport Water Company. Renewal application received: April 26, 2013.

Noncoal Applications Received

Effluent Limits—The following effluent limits will apply to NPDES permits issued in conjunction with a noncoal mining permit:

Table 2

30-day Daily Instantaneous
Parameter Average Maximum Maximum
Suspended solids 10 to 35 mg/l 20 to 70 mg/l 25 to 90 mg/l
Alkalinity exceeding acidity*
pH* greater than 6.0; less than 9.0
* The parameter is applicable at all times.

 A settleable solids instantaneous maximum limit of 0.5 ml/l applied to surface runoff resulting from a precipitation event of less than or equal to a 10-year 24-hour event. If coal will be extracted incidental to the extraction of noncoal minerals, at a minimum, the technology-based effluent limitations identified under coal applications will apply to discharges of wastewater to streams.

Pottsville District Mining Office: 5 West Laurel Boulevard, Pottsville, PA 17901, 570-621-3118

64130801 and NPDES Permit No. PA0225355. LCJ Partners, LLC, (5087 SR 492, Susquehanna, PA 18847), commencement, operation and restoration of a bluestone quarry operation and NPDES Permit for discharge of treated mine drainage in Scott Township, Wayne County affecting 5.0 acres, receiving stream: HQ-cold water and migratory fishes. Application received: April 8, 2013.

0908031C2 and NPDES Permit No. PA022642. Haines & Kibblehouse, Inc., (PO Box 196, Skippack, PA 19474), renewal of NPDES Permit for discharge of treated mine drainage from a quarry operation in Hilltop Township, Bucks County affecting 52.9 acres, receiving stream: unnamed tributary to Morris Run, classified for the following uses; trout stock fishes and migratory fishes. Application received: April 15, 2013.

48980301C7 and NPDES Permit No. PA0223875. Chrin Brothers Inc., (635 Industrial Drive, Easton, PA 18042), renewal of NPDES Permit for discharge of treated mine drainage from a quarry operation in Williams Township, Northampton County affecting 36.8 acres, receiving stream: unnamed tributary to Lehigh River, classified for the following use: cold water fishes. Application received: April 16, 2013.

[Continued on next Web Page]



No part of the information on this site may be reproduced for profit or sold for profit.

This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.