NOTICES
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Applications, Actions and Special Notices
APPLICATIONS
[29 Pa.B. 3927]
APPLICATIONS RECEIVED UNDER THE PENNSYLVANIA CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT
[National Pollution Discharge Elimination System Program (NPDES)]
DISCHARGE OF CONTROLLED INDUSTRIAL WASTE AND SEWERAGE WASTEWATER
(Part I Permits) The following parties have applied for an NPDES permit to discharge controlled wastewaters into the surface waters of this Commonwealth. Unless otherwise indicated on the basis of preliminary review and application of lawful standards and regulations the Department of Environmental Protection (Department) proposes to issue a permit to discharge subject to certain effluent limitations and special conditions. These proposed determinations are tentative.
Where indicated the EPA Region III Administrator has waived the right to review or object to this proposed permit action under the waiver provision 40 CFR 123.6E.
Persons wishing to comment on the proposed permit are invited to submit a statement to the office noted above the application within 30 days from the date of this public notice. Comments received within this 30-day comment period will be considered in the formulation of the final determinations regarding this application. Responses should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held if the responsible office considers the public response significant.
Following the 30-day comment period, the Water Management Program Manager will make a final determination regarding the proposed permit. Notice of this determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.
The application and related documents, proposed effluent limitations and special conditions, comments received and other information are on file and may be inspected and arrangements made for copying at the office indicated above the application.
Persons with a disability who wish to attend the hearing and require an auxiliary aid service or other accommodations to participate in the proceeding should contact the Secretary to the Board at (717) 787-3483. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
Applications for National Pollutant Discharge Elimination System (NPDES) permit to discharge to State waters.
Southeast Regional Office: Regional Manager, Water Management, Lee Park, Suite 6010, 555 North Lane, Conshohocken, PA 19428, (610) 832-6130.
PA 0051756. Sewage, State Farm Mutual Automobile Insurance Company, One State Farm Drive, Concordville, PA 19331.
This application is for renewal of an NPDES permit to discharge treated sewage from the State Farm Mutual Automobile Insurance Company in Concord Township, Delaware County. This is an existing discharge to an unnamed tributary to West Branch Chester Creek.
The receiving stream is classified for the following uses: trout stocking fishery, aquatic life, water supply and recreation.
The proposed effluent limits for Outfall 001, based on an average flow of .025 mgd are as follows:
Average Instantaneous Parameter Monthly (mg/l) Maximum (mg/l) CBOD5 (5-1 to 10-31) 20 40 (11-1 to 4-30) 25 50 Suspended Solids 30 60 Ammonia (as N) (5-1 to 10-31) 3.0 6.0 (11-1 to 4-30) 9.0 18.0 Total Residual Chlorine (3--5 years) 0.3 0.7 Fecal Coliform 200 colonies/100 ml as a geometric average Dissolved Oxygen minimum of 4.0 mg/l at all times pH within limits of 6.0--9.0 standard units at all times Total Residual Chlorine (0--2 years) monitor/report monitor/report Other Conditions:
The EPA waiver is in effect.
PA 0056260. Sewage, Kathleen J. Smith, 2815 Rickerts Road, Dublin, PA 18917.
This application is for renewal of an NPDES permit to discharge treated sewage from the Smith Residence STP in Hilltown Township, Bucks County. This is an existing discharge to an unnamed tributary to Morris Run.
The receiving stream is classified for the following uses: warm water fishery, trout stocking fishery, aquatic life, water supply and recreation.
The proposed effluent limits for Outfall 001, based on an average flow of .0005 mgd are as follows:
Average Instantaneous Parameter Monthly (mg/l) Maximum (mg/l) CBOD5 (5-1 to 10-31) 10 20 (11-1 to 4-30) 20 40 Suspended Solids 10 20 Ammonia (as N) (5-1 to 10-31) 3.0 6.0 (11-1 to 4-30) 9.0 18.0 Total Residual Chlorine monitor/report Fecal Coliform 200 colonies/100 ml as a geometric average Dissolved Oxygen minimum of 3.0 mg/l at all times pH within limits of 6.0--9.0 standard units at all times The EPA waiver is in effect.
PA 0055948. Industrial waste, Sunoco, Inc., Ten Penn Center, 3rd Floor, 1801 Market Street, Philadelphia, PA 19103.
This application is for renewal of an NPDES permit to discharge treated groundwater from former Atlantic Service Station located at 411 County Line Road in Horsham Township, Montgomery County. This is an existing discharge to unnamed tributary to Pennypack Creek.
The receiving stream is classified for the following uses: trout stocking fishery, aquatic life, water supply and recreation.
The proposed effluent limits for Outfall 001, based on an average flow of 5,800 gpd are as follows:
Average Maximum Instantaneous Parameter Monthly (mg/l) Daily (mg/l) Maximum (mg/l) Benzene 0.001 0.002 0.0025 Total BETX* 0.1 0.2 0.25 Ethylbenzene monitor/report monitor/report Toluene monitor/report monitor/report Total Xylenes monitor/report monitor/report Manganese 1.0 2.0 2.5 pH within limits of 6.0--9.0 standard units at all times *BETX shall be measured as sum of benzene, ethylbenzene, toluene and xylenes.
Other Conditions:
The EPA waiver is in effect.
Conditions for future permit modification.
Southcentral Regional Office: Regional Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110-8200, (717) 705-4707.PA 0010677. Industrial waste, SIC: 3824, Veeder-Root Company, P. O. Box 1673, Altoona, PA 16603-1673.
This application is for renewal of an NPDES permit for an existing discharge of treated industrial waste to an unnamed tributary to Spencer Run, in Allegheny Township, Blair County.
The receiving stream is classified for warm water fishes, recreation, water supply and aquatic life. For the purpose of evaluating effluent requirements for TDS, NO2-NO3, fluoride and phenolics, the existing downstream potable water supply intake considered during the evaluation was United Water Company located in Dauphin County. The discharge is not expected to impact any potable water supply.
The proposed effluent limits for Outfall 001 for a design flow of .0048 mgd are:
Average Maximum Instantaneous Parameter Monthly (mg/l) Daily (mg/l) Maximum (mg/l) Flow (mgd) XXX monitor and report XXX pH (s.u.) from 6.0--9.0 inclusive Temperature °F XXX Monitor and report XXX Total Zinc XXX Monitor and report XXX Hexavalent Chromium XXX Monitor and report XXX The proposed effluent limits for Outfall 002 for a design flow of .043 mgd are:
Average Maximum Instantaneous Parameter Monthly (mg/l) Daily (mg/l) Maximum (mg/l) Flow (mgd) XXX XXX XXX pH (s.u.) from 6.0--9.0 inclusive Benzene .001 .002 .0025 Toluene 1.0 2.0 2.5 1,2-Trans-Dichloroethylene .10 .20 .25 1,1,1-Trichloroethane .20 .40 .50 Total PCBs .0000025 .000005 .000006 Persons may make an appointment to review the DEP files on this case by calling Mary DiSanto, File Review Coordinator, at (717) 705-4732.
The EPA waiver is in effect.
PA 0031062. Sewage, SIC: 4952, Robesonia-Wernersville Municipal Authority, P. O. Box 202, Wernersville, PA 19565-0202.
This application is for renewal of an NPDES permit for an existing discharge of treated sewage to Spring Creek, in Heidelberg Township, Berks County.
The receiving stream is classified for trout stocking fishery, recreation, water supply and aquatic life. For the purpose of evaluating effluent requirements for TDS, NO2-NO3, fluoride and phenolics, the existing downstream potable water supply intake considered during the evaluation was Western Berks Water located in Bern Township, Berks County. The discharge is not expected to impact any potable water supply.
The proposed effluent limits for Outfall 001 for a design flow of 1.4 mgd are:
Average Average Instantaneous Parameter Monthly (mg/l) Weekly (mg/l) Maximum (mg/l) CBOD5 25 40 50 Total Suspended Solids 30 45 60 NH3-N (5- to 10-31) 6 12 (11-1 to 4-30) 18 monitor and report Total Phosphorus 1 2 Total Residual Chlorine (Interim) monitor and report monitor and report (Final) 0.39 1/29 Dissolved Oxygen minimum of 5.0 at all times pH from 6.0--9.0 inclusive Fecal Coliforms (5-1 to 9-30) 200/100 ml as a geometric average (10-1 to 4-30) 3,400/100 ml as a geometric average Persons may make an appointment to review the DEP files on this case by calling Mary DiSanto, File Review Coordinator, at (717) 705-4732.
The EPA waiver is not in effect.
Southwest Regional Office: Water Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, (412) 442-4000.PA 0218111. Sewage, Conemaugh Township Supervisors, 1120 Tire Hill Road, Johnstown, PA 15905-7707.
This application is for issuance of an NPDES permit to discharge treated sewage from the Tire Hill Wastewater Treatment Plant in Conemaugh Township, Somerset County.
The following effluent limitations are proposed for discharge to the receiving waters, known as Stony Creek, which are classified as a warm water fishery with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the Saltsburg Municipal Water Works on the Conemaugh River.
Outfall 001: new discharge, design flow of 0.45 mgd.
Concentration (mg/l) Average Average Maximum Instantaneous Parameter Monthly Weekly Daily Maximum CBOD5 25 38 50 Suspended Solids 30 45 60 Ammonia Nitrogen (5-1 to 10-31) 15 22 30 Fecal Coliform (5-1 to 9-30)
(10-1 to 4-30)200/100 ml as a geometric mean
2,000/100 ml as a geometric meanTotal Residual Chlorine 0.5 1.6 pH not less than 6.0 nor greater than 9.0 The EPA waiver is in effect.
Northwest Regional Office: Regional Manager, Water Management, 230 Chestnut Street, Meadville, PA 16335, (814) 332-6942.PA 0222151--Amendment No. 1. Industrial waste. Witco Corporation, One American Lane, Greenwich, CT 06831.
This application is for an amendment of a Part I NPDES permit, to discharge treated groundwater to Tunungwant Creek in Bradford, McKean County. This is an existing discharge.
The receiving water is classified for the following uses: warm water fishes, aquatic life, water supply and recreation. For the purpose of evaluating effluent requirements for TDS, NO2-NO3, fluoride and phenolics, the existing/proposed downstream potable water supply considered during the evaluation is the PA/NY state line on Tunungwant Creek located at Bradford, McKean County, approximately 2.7 miles below point of discharge.
The proposed discharge limits, based on a design flow of .367 mgd, are:
Outfall No. 001, Interim Limits
Average Maximum Instantaneous Parameter Monthly (mg/l) Daily (mg/l) Maximum (mg/l) Flow XX Total Iron XX XX XX Oil and Grease 15 30 Dissolved Iron 7 pH 6.0--9.0 at all times Outfall No. 001, Final Limits
Average Maximum Instantaneous Parameter Monthly (mg/l) Daily (mg/l) Maximum (mg/l) Flow XX XX XX Total Iron 3.5 7 8.8 Oil and Grease 15 30 Dissolved Iron 7 pH 6.0--9.0 at all times Final technology based limitation for total iron.
The EPA waiver is in effect.
PA 0029726. Sewage. Jamestown Municipal Authority P. O. Box 188, Jamestown, PA 16134.
This application is to hydraulically rerate the NPDES permit to discharge treated sewage to the Shenango River in Jamestown Borough, Mercer County. This is a minor discharge.
The receiving water is classified for the following uses: warm water fishes, aquatic life, water supply and recreation. For the purpose of evaluating effluent requirements for TDS, NO2-NO3, fluoride and phenolics, the existing/proposed downstream potable water supply considered during the evaluation is the Greenville Municipal Authority intake on the Shenango River located at Greenville, approximately 7 miles below point of discharge.
The proposed effluent limits, based on a design flow of 0.15 mgd, are:
Outfall No. 001, Interim Limits
Average Weekly Instantaneous Parameter Monthly (mg/l) Average (mg/l) Maximum (mg/l) CBOD5 (5-1 to 10-31) 25 40 50 (11-1 to 4-30) 20 30 40 TSS 30 45 60 Ammonia-Nitrogen (5-1 to 10-31) 9 18 (11-1 to 4-30) 7 14 Total Phosphorus (as P) 1 2 Fecal Coliform (5-1 to 9-30) 200/100 ml as a geometric average (10-1 to 4-30) 34,500/100 ml as a geometric average Total Residual Chlorine 0.5 1.2 pH 6.0--9.0 at all times The proposed effluent limits, based on a design flow of 0.26 mgd, are:
Outfall No. 001, Final Limits
Average Weekly Instantaneous Parameter Monthly (mg/l) Average (mg/l) Maximum (mg/l) CBOD5 25 40 50 TSS 30 45 60 Ammonia-Nitrogen (5-1 to 10-31) 20 40 Total Phosphorus (as P) 1 2 Fecal Coliform (5-1 to 9-30) 200/100 ml as a geometric average (10-1 to 4-30) 48,300/100 ml as a geometric average Total Residual Chlorine 0.5 1.6 pH 6.0--9.0 at all times The EPA waiver is in effect.
PA 0037991. Sewage, Imperial Point North, 563 Chaucer Court, Girard, PA 16417.
This application is for renewal of an NPDES permit to discharge treated sanitary sewage to an unnamed tributary to Lake Erie in Girard Township, Erie County. This is an existing discharge.
The receiving water is classified for cold water and migratory fishery, aquatic life, water supply and recreation. For the purpose of evaluating effluent requirements for TDS, NO2-NO3, fluoride and phenolics, there is no existing/proposed downstream potable water supply to consider during the evaluation.
The proposed effluent limits for Outfall 001, based on average design flow of 0.080 mgd, are:
Effluent Concentration (mg/l) Average Instantaneous Parameter Monthly Maximum CBOD5 25 50 Total Suspended Solids 30 60 NH3-N (5-1 to 10-31) 2.0 4.0 (11-1 to 4-30) 6.0 12 Total Residual Chlorine 0.26 Phosphorus as P 1.0 Dissolved Oxygen minimum of 3.0 mg/l at all times Fecal Coliform (5-1 to 9-30) 200/100 ml as a geometric average (10-1 to 4-30) 2,300/100 ml as a geometric average pH 6.0--9.0 standard units at all times The EPA waiver is in effect.
Proposed NPDES Permit Renewal Actions for Minor Sewage Discharges
The following parties have applied to renew their current NPDES permits to allow the continued discharge of controlled wastewaters into the surface waters of this Commonwealth. The Department of Environmental Protection (Department) has made a tentative determination to renew these permits and proposes to issue them, subject to their current permit effluent limitations and monitoring and reporting requirements, with appropriate and necessary updated requirements to reflect new or changed regulations and other requirements. The updates may include, but will not be limited to, applicable permit conditions and/or requirements addressing combined sewer overflows (CSOs), municipal sewage sludge management and total residual chlorine control (TRC). Major changes to or deviations from the terms of the existing permit will be documented and published with the final Department actions.
The EPA, Region III, Regional Administrator has waived the right to review or object to these proposed permit actions under the waiver provision 40 CFR 123.6E.
Persons wishing to comment on the proposed permits are invited to submit a statement to the Field Operations indicated as the office responsible, within 30 days from the date of this public notice. Comments received within this 30-day period will be considered in the formulation of the final determinations regarding these applications and proposed permit actions. Comments should include the name, address and telephone number of the writer and a brief statement to inform the Field Office of the basis of the comment and the relevant facts upon which it is based. A public hearing may be held if the Field Office considers the public response significant.
Following the 30-day comment period, the Water Management Program Manager will make a final determination regarding the proposed permit action. Notice of this determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.
The permit renewal application and related documents, proposed effluent limitations and special conditions, comments received and other information are on the Department's file. The documents may be inspected at, or a copy requested from, the Field Office that has been indicated above the application notice.
Southcentral Regional Office: Water Management Program, 909 Elmerton Avenue, 2nd Floor, Harrisburg, PA 17110, (717) 705-4707.
NPDES Facility County and Tributary New Permit No. Name and Address Municipality Stream Requirements PA 0041220 RMC Enterprises, Inc.
P. O. Box 381
Elizabethtown, PA
17022-0381Dauphin County
Conewago
TownshipUNT to
Conewago
CreekTRC PA 0086495 Metal Industries Home
Products, Inc.
P. O. Box 305
Gratz, PA 17030-0305Dauphin County
Gratz
BoroughWiconisco
CreekTRC PA 0086355 Howard D. and Shari M. Soule
7312 Sandy Hollow Road
Harrisburg, PA 17112Dauphin County
West Hanover
TownshipUNT to
Beaver
CreekTRC
DISCHARGE OF CONTROLLED INDUSTRIAL WASTE AND SEWERAGE WASTEWATER
Applications under the Pennsylvania Clean Streams Law
(Part II Permits) The following permit applications and requests for plan approval have been received by the Department of Environmental Protection (Department).
Persons objecting on the grounds of public or private interest to the approval of an application or submitted plan may file a written protest with the Department at the address indicated above each permit application or plan. Each written protest should contain the following: name, address and telephone number; identification of the plan or application to which the protest is addressed; and a concise statement in sufficient detail to inform the Department of the exact basis of the protest and the relevant facts upon which it is based. The Department may conduct a fact-finding hearing or an informal conference in response to any given protest. Each commentator will be notified in writing of the time and place if a hearing or conference concerning the plan, action or application to which the protest relates is held. To insure consideration by the Department prior to final action on permit applications and proposed plans, initial protests and additions or amendments to protests already filed should be filed within 15 calendar days from the date of this issue of the Pennsylvania Bulletin. A copy of each permit application and proposed plan is on file in the office indicated and is open to public inspection.
Persons with a disability who wish to attend the hearing and require an auxiliary aid, service or other accommodation to participate in the proceeding should contact the Secretary to the Board at (717) 787-3483. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
Industrial waste and sewerage applications under The Clean Streams Law (35 P. S. §§ 691.1--691.1001).
Southeast Regional Office: Regional Water Management Program Manager, Lee Park, Suite 6010, 555 North Lane, Conshohocken, PA 19428, (610) 832-6130.
WQM Permit No. 1599411. Sewerage. East Goshen Township Municipal Authority, 1580 Paoli Pike, West Chester, PA 19380. Applicant requests approval for the construction and operation of two pump stations with force main to serve Mill Valley, a residential community located in East Goshen Township, Chester County.
WQM Permit No. 1599412. Sewerage. Eugene McKenna, 131 Germany Hollow Road, Honeybrook, PA 19320. Applicant requests approval for the construction and operation for a single residential STP located in West Brandywine Township, Chester County.
WQM Permit No. 4699419. Sewerage. Whitemarsh Township, 616 Germantown Pike, Lafayette Hill, PA 19444-1821. Applicant requests modification to reduce/eliminate chlorine residual levels at the wastewater treatment plan located in Whitemarsh Township, Montgomery County.
WQM Permit No. 4699201. Industrial waste. Lonza, Inc., 900 River Road, Conshohocken, PA 19428. Applicant requests approval for construction and operation to expand the wastewater treatment plant located in Upper Merion Township, Montgomery County.
Southwest Regional Office: Water Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, (412) 442-4000.
A. 3099402. Sewerage. Consol Pennsylvania Coal Company, 1800 Washington Road, Pittsburgh, PA 15241. Application for the construction and operation of a sewage treatment plant to serve the Crabapple Portal Facility located in Richhill Township, Greene County.
Southwest Regional Office: Regional Oil and Gas Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, (412) 442-4000.
WQM Permit No. 3286201-T1. Industrial waste. Franklin Brine Treatment Corporation, RD 2, Box 403-R, U. S. Route 322 East, Franklin, PA. Application to modify an existing industrial wastewater treatment facility in Burrell Township, Indiana County. Application received in the Regional Office: June 21, 1999.
Northwest Regional Office: Regional Water Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481, (814) 332-6942.
WQM Permit No. 6299409. Sewage, Mary Beth Burnell and Richard L. Morrell, SRSTP, R. R. 3, Box 39A, Sugar Grove, PA 16350. This project is for the construction of a single residence sewage treatment plant in Sugar Grove Township, Warren County.
INDIVIDUAL PERMITS
(PAS)
NPDES Individual
The following parties have applied for an NPDES permit to discharge stormwater from a proposed construction activity into the surface waters of this Commonwealth. Unless otherwise indicated, on the basis of preliminary review and application of lawful standards and regulations, the Department of Environmental Protection (Department) proposes to issue a permit to discharge, subject to certain limitations set forth in the permit and special conditions. The proposed determinations are tentative. Limitations are provided in the permit as erosion and sedimentation control measures and facilities which restrict the rate and quantity of sediment discharged.
Where indicated, the EPA, Region III, Regional Administrator has waived the right to review or object to this proposed permit action under the waiver provision of 40 CFR 123.24(d).
Persons wishing to comment on the proposed permit are invited to submit a statement to the office noted above the application within 30 days from the date of this public notice. Comments reviewed within this 30-day period will be considered in the formulation of the final determinations regarding this application. Responses should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held if the responsible office considers the public response significant.
Following the 30-day comment period, the Water Management Program Manager will make a final determination regarding the proposed permit. Notice of this determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.
The application and related documents, including the erosion and sedimentation control plan for the construction activity, are on file and may be inspected at the office noted above the application.
Persons with a disability who wish to attend the hearing and require an auxiliary aid, service or other accommodation to participate in the proceedings, should contact the specified program. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
Southeast Regional Office: Regional Water Management Program Manager, Lee Park, Suite 6010, 555 North Lane, Conshohocken, PA 19428-2233, (610) 832-6130.
NPDES Permit PAS10-D111. Stormwater. Katz Builders and Developers, 541 West Germantown Pike, Plymouth Meeting, PA 19462, has applied to discharge stormwater from a construction activity located in Solebury Township, Bucks County to Aquetong Creek.
NPDES Permit PAS10-G370. Stormwater. East Vincent Township, 900 West Bridge Street, Spring City, PA, has applied to discharge stormwater from a construction activity located in East Vincent Township, Chester County, to Schuylkill River and Stoney Run.
Northeast Regional Office: Regional Water Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790, (570) 826-2511.
Lehigh County Conservation District, District Manager, Lehigh Ag. Ctr., Ste. 102, 4184 Dorney Park Road, Allentown, PA 18104, (610) 391-9583.
NPDES Permit PAS10Q178. Stormwater. Hope Community Church, Joseph Beblavy, 2074 Hefner Road, Fogelsville, PA 18051-2320, has applied to discharge stormwater from a construction activity located in Weisenberg Township, Lehigh County, to Hassen Creek.
Southcentral Regional Office: Regional Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110-8200, (717) 657-4707.
Mifflin County Conservation District, District Manager, 20 Windmill Hill Rm. 4, Burnham, PA 17009, (717) 248-4695.
NPDES Permit PAS-10-4505. Stormwater. Milroy Associates, 269 Waring Avenue, State College, PA 16801, has applied to discharge stormwater from a construction activity located in Armagh Township, Mifflin County, to Tea Creek.
Franklin County Conservation District, District Manager, 550 Cleveland Avenue, Chambersburg, PA 17201, (717) 264-8074.
NPDES Permit PAS-10-M105. Stormwater. Galen Powers Land Development, 2341 Falling Spring Road, Chambersburg, PA 17201, has applied to discharge stormwater from a construction activity located in Guilford Township, Franklin County, to Falling Spring Creek.
Northcentral Regional Office: Regional Water Management Program Manager, 208 W. Third St., Suite 101, Williamsport, PA 17701, (717) 327-3574.
Clinton County Conservation District, 36 Spring Run Rd., Rm. 104, Mill Hall, PA 17751, (570) 726-3798.
NPDES Permit PAS101916. Stormwater. Columbia Gas Transmission has applied to discharge stormwater from a construction activity located in Beech Creek, Noyes, Chapman, Grugan and Gallagher Townships, Clinton County to Big Run, W. Branch, Panther Branch, Swamp Branch, Middle Branch, East Branch, Cleneenin Branch of Baker Run, Cranberry Run, Benjamin Run, Sled Road Hollow, Stevens Valley Run, Goodman Hollow, Johnson Run, Bear Pen Run, Rickey Run.
Southwest Regional Office: Regional Water Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, (412) 442-4000.
NPDES Permit PAS10A109. Stormwater. Ron Plisco, P. O. Box 545, Monroeville, PA 15146, has applied to discharge water from a construction activity located in North Versailles Township, Allegheny County to Jacks Run.
NPDES Permit PAS100244. Stormwater. Level 3 Communications, 14023 Denver West Parkway, Golden, Colorado 80401-3107, has applied to discharge water from a construction activity located in Ambridge Borough, Baden Borough, Beaver Falls Borough, Big Beaver Borough, Conway Borough, Darlington Township, East Rochester Borough, Freedom Borough, Harmony Township, Homewood Borough, New Brighton Borough, New Galilee Borough, Patterson Heights Borough, Rochester Borough, West Mayfield Borough, Beaver County; Enon Valley Borough, Little Beaver Township, New Beaver Borough, Lawrence County; and Avalon Borough, Bellevue Borough, Ben Avon Borough, Edgeworth Borough, Emsworth Borough, Glenfield Borough, Hayville Borough, Kilbuck Township, Leet Township, Leetsdale Borough, Osborne Borough, City of Pittsburgh, Ross Township, Sewickley Borough, Allegheny County to Big Sewickley Creek, UNT Ohio River, Legionville Run, Tavebau Run, Crows Run, Walnut Bottom Run, Wallace Run, UNT Beaver River, Clarks Run, Dutchman Run, Fasburg Run, LaCock Run, Beaver River, McKinley Run, Blockhouse Run, Jordan Run, UNT NF Little Beaver Creek, NF Little Beaver Creek, Spruce Run, Lowries Run, Toms Run, Kilburck Run, Jacks Run and Little Sewickley Creek.
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.