PA Bulletin, Doc. No. 05-946b

[35 Pa.B. 2905]

[Continued from previous Web Page]

   63.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of CO from the exhaust of the auxiliary boiler shall not exceed 63 ppm corrected to 3% oxygen and 0.077 pound per million Btu of heat input, 5.01 pounds per hour and 4.2 tons in any 12 consecutive month period.

   64.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the LAER of the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217 as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of NOx, from the exhaust of the auxiliary boiler shall not exceed 0.09 pound per million Btu of heat input, 5.85 pounds per hour and 4.9 tons in any 12 consecutive month period.

   65.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the LAER of the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217 as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of VOCs from the exhaust of the auxiliary boiler shall not exceed 0.005 pound per million Btu of heat input, 0.325 pounds per hour and 0.3 ton in any 12 consecutive month period.

   66.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the permittee shall not emit any hydrogen chloride (HCl) emissions from the exhaust of the auxiliary boiler.

   67.  Under the BAT provisions in 25 Pa. Code §§ 27.1 and 127.12, the emission of total combined hazardous air pollutants (HAPs) from the exhaust of the auxiliary boiler shall not exceed 0.023 pound per hour and 0.02 ton in any 12 consecutive month period.

   68.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, only virgin No. 2 fuel oil shall be fired in the auxiliary boiler.

   69.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the auxiliary boiler shall not operate more than 1,680 hours in any 12 consecutive month period.

   70.  Within 60 days after achieving the maximum firing rate at which the auxiliary boiler will be operated but not later than 180 days after commencement of operation of the auxiliary boiler, the permittee shall perform opacity tests on the exhaust of the auxiliary boiler to verify that the opacity limitation of the auxiliary boiler. All testing shall be performed while the auxiliary boiler is operating at its maximum rate of production, using test methods and procedures approved by the Department. The results of the opacity test shall be reported to the Department within 60 days of completion of testing.

   71.  Within 120 days of achieving maximum production, but no later than 180 days after initial startup, the permittee shall perform testing on the exhaust of the auxiliary boiler to determine the nitrogen oxide, carbon monoxide, total particulate matter, and total combined HAP emission rates. The NOx and CO stack testing shall be conducted simultaneously. All testing shall be performed while the auxiliary boiler is operating at its maximum rate of production, using test methods and procedures approved by the Department.

   72.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the auxiliary boiler shall be equipped with instrumentation to monitor and record fuel oil usage.

   73.  The permittee shall maintain comprehensive and accurate records of: the number of hours that the auxiliary boiler operates each month and shall verify compliance with the operation hours restriction in any 12 consecutive month period; and the amount and type of fuel used in the auxiliary boiler each month.

   74.  The permittee shall keep comprehensive and accurate records of: the supporting calculations for the total particulate matter emissions from the auxiliary boiler to verify compliance with the total particulate matter emissions limitations of pound per million Btu of heat input, pounds per hour and tons in any 12 consecutive month period; the supporting calculations for SO2 emissions from the auxiliary boiler to verify compliance with the SO2 emissions limitations of pound per million Btu of heat input, pounds per hour and tons in any 12 consecutive month period; the supporting calculations for CO emissions from the auxiliary boiler to verify compliance with the CO emissions limitations of parts per million corrected to 3% oxygen, pound per million Btu of heat input, pounds per hour and tons in any 12 consecutive month period; the supporting calculations for NOx emissions from the auxiliary boiler to verify compliance with the NOx emissions limitations of pounds per million Btu of heat input, pounds per hour and tons in any 12 consecutive month period; the supporting calculations for VOC emissions from the auxiliary boiler to verify compliance with the VOC emissions limitations of pounds per million Btu of heat input, pounds per hour and tons in any 12 consecutive month period; and the total combined HAPs emissions from the auxiliary boiler to verify compliance with the total combined HAPs emissions limitations of pounds per hour and tons in any 12 consecutive month period.

   75.  The permittee shall maintain comprehensive and accurate records of the amount of virgin No. 2 fuel oil combusted in the auxiliary boiler during each day.

   76.  The permittee shall submit reports to the Department on a semiannual basis that include: the supporting calculations used to verify compliance with the SO2, CO, total particulate matter, NOx, VOC and total combined HAPs emissions limitations in any 12 consecutive month period; the permittee shall submit reports to the Department on a semiannual basis that include the records of the number of hours that the auxiliary boiler operates each month and the calculations used to verify compliance with the operation hours restriction in any 12 consecutive month period; and the permittee shall submit reports to the Department on a semiannual basis that include the records of the amount and type of fuel used in the auxiliary boiler each month.

   77.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the LAER of the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217 as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the permittee shall utilize low-NOx burners (LNB) and flue gas recirculation (FGR) technology to control NOx emissions from the auxiliary boiler. The auxiliary boiler shall not be operated without the inclusion of LNB and FGR. The auxiliary boiler shall be rated at 65 million Btu per hour of heat input.

   78.  The auxiliary boiler is subject to the New Source Performance Standards, 40 CFR Part 60, Subpart Dc and shall comply with all applicable requirements as specified in 40 CFR 60.40c--60.48c.

   79.  The auxiliary boiler is subject to the National Emission Standards for Hazardous Air Pollutants, 40 CFR Part 63, Subpart DDDDD and shall comply with all applicable requirements as specified in 40 CFR 63.7480--63.7575.

   80.  The permittee shall submit to the Department for approval the specific make and model of the auxiliary boiler, including design parameters of the LNB and FGR system within 30 days of issuing the purchase order for the specified source by submitting the appropriate pages of the plan approval application.

   81.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the visible emissions from the emergency generator shall not equal or exceed 10% opacity for a period or periods aggregating more than 3 minutes in any one hour or equal or exceed 30% opacity at any time.

   82.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the LAER of the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of NOx, from the exhaust of the emergency generator shall not exceed 6.9 grams per horsepower-hour and 3.82 tons in any 12 consecutive month period.

   83.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of CO from the exhaust of the emergency generator shall not exceed 1.34 grams per horsepower-hour and 0.743 ton in any 12 consecutive month period.

   84.  Under the LAER of the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of total hydrocarbons (THCs) from the exhaust of the emergency generator shall not 0.25 gram per horsepower-hour and 0.14 ton in any 12 consecutive month period.

   85.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of SO2 from the exhaust of the emergency generator shall not exceed 0.736 gram per horsepower-hour and 0.408 ton in any 12 consecutive month period.

   86.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of total particulate matter from the exhaust of the emergency generator shall not exceed 0.215 gram per horsepower-hour and 0.119 ton in any 12 consecutive month period.

   87.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emergency generator shall fire only No. 2 fuel oil and the generator shall not be operated more than 500 hours in any 12 consecutive month period.

   88.  Within 180 days of the commencement of operation of the emergency generator, stack testing shall be performed on the engine to determine its NOx, total hydrocarbons, total particulate matter and CO emission rates using reference method test procedures, which are acceptable to the Department. In addition to the stack testing required by this condition, within 12 months after the initial stack testing, and annually thereafter, the permittee shall perform NOx and CO emissions tests upon the emergency generator using a portable analyzer approved by the Department. The Department may alter the frequency of annual portable analyzer tests based on the results and sufficient justification.

   89.  The permittee shall keep comprehensive and accurate records of: the number of hours that the emergency generator operates each month and hours of operation to verify compliance with the operation hours restriction in any 12 consecutive month period; and the amount and type of fuel used in the emergency generator each month.

   90.  The permittee shall keep comprehensive and accurate records of: the supporting calculations for NOx emissions from the emergency generator to verify compliance with the NOx emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; the supporting calculations for CO emissions from the emergency generator to verify compliance with the CO emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; the supporting calculations for THC emissions from the emergency generator to verify compliance with the THC emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; the supporting calculations for SO2 emissions from the emergency generator to verify compliance with the SO2 emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; and the supporting calculations for total particulate matter emissions from the emergency generator to verify compliance with the total particulate matter emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period.

   91.  The permittee shall submit reports to the Department on a semiannual basis that include: the records of the number of hours that the emergency generator operates each month and verify compliance with the operation hours restriction in any 12 consecutive month period; and the supporting calculations used to verify compliance with the NOx, CO, THC, SO2 and the total particulate matter emissions limitations in any 12 consecutive month period.

   92.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emergency generator shall be a 1,005.8 hp Caterpillar 3412C TA diesel-fired engine.

   93.  The emergency generator is subject to the National Emission Standards for Hazardous Air Pollutants, 40 CFR Part 63, Subpart ZZZZ and shall comply with all applicable requirements as specified in 40 CFR 63.6580--63.6675.

   94.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the visible emissions from the fire pump shall not equal or exceed 10% opacity for a period or periods aggregating more than 3 minutes in any one hour or equal or exceed 30% opacity at any time.

   95.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the LAER of the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of NOx, from the exhaust of the fire pump shall not exceed 5.4 grams per horsepower-hour and 0.68 ton in any 12 consecutive month period.

   96.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of CO from the exhaust of the fire pump shall not exceed 0.765 gram per horsepower-hour and 0.095 ton in any 12 consecutive month period.

   97.  Under the LAER of the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of THCs from the exhaust of the fire pump shall not exceed 0.16 gram per horsepower-hour and 0.02 ton in any 12 consecutive month period.

   98.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of SO2 from the exhaust of the fire pump shall not exceed 0.681 gram per horsepower-hour and 0.0845 ton in any 12 consecutive month period.

   99.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of total particulate matter from the exhaust of the fire pump shall not exceed 0.10069 gram per horsepower-hour and 0.0125 ton in any 12 consecutive month period.

   100.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the fire pump shall fire only No. 2 fuel oil and the fire pump shall not be operated more than 500 hours in any 12 consecutive month period.

   101.  The permittee shall keep comprehensive and accurate records of: the number of hours that the fire pump operates each month and hours of operation to verify compliance with the operation hours restriction in any 12 consecutive month period; and the amount and type of fuel used in the fire pump each month.

   102.  The permittee shall keep comprehensive and accurate records of: the supporting calculations for NOx emissions from the fire pump to verify compliance with the NOx emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; the supporting calculations for CO emissions from the fire pump to verify compliance with the CO emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; the supporting calculations for THC emissions from the fire pump to verify compliance with the THC emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; the supporting calculations for SO2 emissions from the fire pump to verify compliance with the SO2 emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period; and the supporting calculations for total particulate matter emissions from the fire pump to verify compliance with the total particulate matter emissions limitations of grams per horsepower-hour and tons in any 12 consecutive month period.

   103.  The permittee shall submit reports to the Department on a semiannual basis that include: the records of the number of hours that the fire pump operates each month and verify compliance with the operation hours restriction in any 12 consecutive month period; and the supporting calculations used to verify compliance with the NOx, CO, THC, SO2, and the total particulate matter emissions limitations in any 12 consecutive month period.

   104.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the fire pump shall be a 225.3 hp Caterpillar 3126B diesel-fired engine.

   105.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the total particulate matter in the exhaust of: the bin vent fabric collector associated with the primary crushing building shall not exceed a concentration of 0.01 grain per dry standard cubic foot, 2.57 pounds per hour at any time, and 11.263 tons per year; the bin vent fabric collector associated with the screening and secondary crusher building shall not exceed a concentration of 0.01 grain per dry standard cubic foot, 2.57 pounds per hour at any time, and 11.263 tons per year; and the bin vent fabric collector associated with the boiler building shall not exceed a concentration of 0.01 grain per dry standard cubic foot, 0.043 pound per hour at any time, and 0.188 ton per year. Additionally, the opacity of the exhaust of each bin vent fabric collector associated with the coal processing operation shall not exceed 10% at any time.

   106.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, each bin vent fabric collector associated with the coal processing operation shall be equipped with instrumentation to continuously monitor the differential pressure across each bin vent fabric collector.

   107.  The permittee shall keep records of the differential pressure of each bin vent fabric collector associated with the coal processing operation at least on a daily basis. A sufficient quantity of spare fabric bags for each bin vent fabric collector associated with the coal processing operation shall be kept on hand at all times in order to immediately replace any worn or damaged bags.

   108.  If any piece of equipment of the coal processing operation is causing the emission of fugitive particulate matter in excess of the limitations specified in all applicable requirements of 25 Pa. Code § 123.1 and Subpart Y of the Federal Standards of Performance for New Stationary Sources, 40 CFR 60.250--60.254 as determined by the Department, or in excess of the level which the Department considers to be the ''minimum attainable through the use of the BAT,'' the permittee shall, upon notification by the Department, immediately take control measures as are necessary to reduce the air contaminant emissions to within the level deemed acceptable by the Department.

   109.  The coal processing operation consists of the following equipment: equipment located in a partially enclosed building four 425 ton capacity coal hoppers rated at 300 ton per hour each and four belt feeders rated at 300 ton per hour each; equipment located inside the primary crushing building; two-700 ton per hour scalping coal screens and two 700 ton per hour Bradford Breakers; equipment located inside the screening and secondary crusher building 350 ton per hour coal scalping screen, 100 ton surge bin, and three-secondary hammermill crushers; equipment located inside the boiler building--36" by 150` silo tripper conveyor and four 900 ton capacity coal storage silos; equipment not located inside a building--36" by 700` fully enclosed yard conveyor A, 36" by 500` fully enclosed yard conveyor B, and 36" by 700` fully enclosed yard conveyor C.

   110.   Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the air contaminant emissions from the two-700 ton per hour scalping coal screens and the two 700 ton Bradford Breakers associated with the coal processing operation located in the primary crushing building shall be controlled by a bin vent fabric collector, the air contaminant emissions from the 350 ton per hour coal scalping screen, 100 ton surge bin and the three-secondary hammermill crushers associated with the coal processing operation located in the screening and secondary crusher building shall be controlled by a bin vent fabric collector, and the air contaminant emissions from the four 900 ton capacity coal storage silos associated with the coal processing operation located in the boiler building shall be controlled by a bin vent fabric collector.

   111.  The bin vent fabric collectors associated with the primary crushing building and associated with the screening and secondary crusher building shall each have a maximum air flow of 30,000 ACFM, an effective air to cloth ratio at actual conditions of not more than 7:1 and using reverse air jets cleaning system. The bin vent fabric collector associated with the boiler building shall have a maximum air flow of 500 ACFM, an effective air to cloth ratio at actual conditions of not more than 7:1 and using reverse air jets cleaning system.

   112.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the coal processing operation shall not operate if any bin vent fabric collectors are inoperable. In addition, all conveyors associated with the coal processing operation, which are not entirely located inside a building, shall be fully enclosed except for where the material enters and exits the conveyor.

   113.  The coal processing operation is subject to the Standards of Performance for New Stationary Sources, 40 CFR Part 60, Subpart Y and shall comply with all applicable requirements as specified in 40 CFR Sections 60.250--60.254.

   114.  The permittee shall submit to the Department for approval the specific make and model and the corresponding design details of the two 700 ton per hour scalping coal screens, the two 700 ton per hour Bradford Breakers, the 350 ton per hour coal scalping screen and the three secondary hammermill crushers associated with the coal processing operation, as well as the specific make and model of the bin vent fabric collectors within 30 days of issuing the purchase order for the specified equipment by submitting the appropriate pages of the plan approval application.

   115.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the total particulate matter in the exhaust of the bin vent fabric collector associated with the bed ash silo shall not exceed a concentration of 0.01 grain per dry standard cubic foot, 0.034 pound per hour, and 0.15 ton per year. Additionally, the bin vent fabric collector associated with the bed ash silo shall be equipped with instrumentation to continuously monitor the differential pressure across the bin vent fabric collector.

   116.  The permittee shall keep records of the differential pressure of the bin vent fabric collector associated with the bed ash silo at least once each day. The permittee shall keep records of the amount of bed ash loaded into trucks on a monthly basis and shall verify the amount of bed ash loaded into trucks in any 12 consecutive month period. The permittee shall submit reports to the Department on a semi-annual basis that include the records of the amount of bed ash loaded into trucks on a monthly basis and shall verify the limitation of the amount of bed ash loaded into trucks in any 12 consecutive month period. Additionally, a sufficient quantity of spare fabric bags for the bin vent fabric collector associated with the bed ash silo shall be kept on hand at all times in order to immediately replace any worn or damaged bags.

   117.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the bed ash shall be sufficiently conditioned with water in a pug mill prior to the loading of bed ash into trucks in order to prevent fugitive emissions from occurring. The bed ash silo shall be a 5,850 ton capacity silo whose air contaminant emissions shall be controlled by a bin vent fabric collector. The bed ash silo shall not operate if the bin vent fabric collector is inoperable. The bin vent fabric collector shall have an air flow of 400 ACFM, an effective air to cloth ratio at actual conditions of not more than 7:1 and using reverse air jets cleaning system.

   118.  The permittee shall submit to the Department for approval the specific make and model of the bin vent fabric collector associated with the bed ash silo within 30 days of issuing the purchase order for the specified equipment by submitting the appropriate pages of the plan approval application.

   119.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, no more than 661,085 tons of bed ash shall be loaded into trucks from the bed ash silo in any 12 consecutive month period.

   120.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the total particulate matter from the exhaust of each bin vent fabric collector associated with each fly ash storage silo shall not exceed a concentration of 0.01 grain per dry standard cubic foot. In addition, the total particulate matter from the exhaust of each bin vent fabric collector associated with each fly ash storage silo shall not exceed 0.0345 pound per hour at any time and 0.15 ton per year.

   121.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, each bin vent fabric collector associated with each fly ash storage silo shall be equipped with instrumentation to continuously monitor the differential pressure across each bin vent fabric collector.

   122.  The permittee shall keep records of the differential pressure of the each bin vent fabric collector associated with each fly ash storage silo at least on a daily basis. The permittee shall keep records of the amount fly ash loaded into trucks on a monthly basis and shall verify the amount of fly ash loaded into trucks in any 12 consecutive month period. The permittee shall submit reports to the Department on a semiannual basis that include the records of the amount of fly ash loaded into trucks on a monthly basis and shall verify the limitation of the amount of fly ash loaded into trucks in any 12 consecutive month period. Additionally, a sufficient quantity of spare fabric bags for each bin vent fabric collector shall be kept on hand at all times in order to immediately replace any worn or damaged bags.

   123.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the fly ash from fly ash silo No. 1 and fly ash silo No.2 contained in the fly ash storage silos shall be sufficiently conditioned with water in a pug mill prior to the loading of fly ash into trucks in order to prevent fugitive emissions from occurring.

   124.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83 and the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the fly ash storage silos shall be a 2,925 ton capacity fly ash storage silo No.1 and a 2,925 ton capacity fly ash storage silo No.2. The air contaminant emissions from fly ash storage silo No.1 and fly ash storage silo No. 2 of the fly ash storage silos shall each be controlled by a bin vent fabric collector. The fly ash storage silo No. 1 shall not operate if its bin vent fabric collector is inoperable. Additionally, the fly ash storage silo No. 2 associated with the fly ash storage silos shall not operate if its bin vent fabric collector is inoperable. The bin vent fabric collectors shall each have an air flow of 400 ACFM, an effective air to cloth ratio at actual conditions of not more than 7:1 using reverse air jets cleaning system.

   125.  The permittee shall submit to the Department for approval the specific make and model of each bin vent fabric collector associated with each fly ash storage silo within 30 days of issuing the purchase order for the specified equipment by submitting the appropriate pages of the plan approval application.

   126.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, no more than combined total of 991,627 tons per year of fly ash shall be loaded into trucks from the fly ash storage silos.

   127.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the total particulate matter from the exhaust of bin vent fabric collector associated with the limestone storage silo shall not exceed a concentration of 0.01 grain per dry standard cubic foot, 0.017 pound per hour at any time, and 0.075 ton per year. Additionally, the total particulate matter from the exhaust of the bin vent fabric collector associated with limestone processing within the boiler building shall not exceed a concentration of 0.01 grain per dry standard cubic foot, 0.013 pound per hour at any time, and 0.056 ton per year.

   128.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, Each bin vent fabric collector associated with the limestone conveying and processing operation shall be equipped with instrumentation to continuously monitor the differential pressure across each bin vent fabric collector.

   129.  The permittee shall keep records of the differential pressure of each bin vent fabric collector associated with the limestone conveying and processing operation at least once each day. Additionally, a sufficient quantity of spare fabric bags for each bin vent fabric collector associated with Source P107 shall be kept on hand at all times to immediately replace any worn or damaged bags.

   130.  If any piece of equipment of the limestone conveying and processing operation is causing the emission of fugitive particulate matter in excess of the limitations specified in all applicable requirements of 25 Pa. Code § 123.1 and Subpart OOO of the Standards of Performance for New Stationary Sources, 40 CFR 60.670--60.676, as determined by the Department, or in excess of the level which the Department considers to be the ''minimum attainable through the use of the BAT,'' the permittee shall, upon notification by the Department, immediately take such control measures as are necessary to reduce the air contaminant emissions to within the level deemed acceptable by the Department.

   131.  The limestone conveying and processing operation is a limestone conveying and processing operation consisting of the following equipment: equipment not located inside a building 100 ton limestone hopper, 36" by 800` fully enclosed conveyor, 1,150 ton limestone storage silo, 36'' by 50' fully enclosed conveyor, 36" by 700` fully enclosed conveyor; equipment located inside the boiler building 36" by 150` conveyor, two 525 ton limestone storage hoppers, two 36" by 50` conveyors, and two milling machines. Any of this equipment can be replaced provided that the replacement equipment is of equal or smaller size as defined in Subpart OOO of the Standards of Performance for New Stationary Sources, 40 CFR 60.670--60.676, and provided that the replacement equipment is of equivalent design and function (for example, a limestone hopper may be replaced with a same size limestone hopper, and the like). The permittee shall notify the Department prior to the replacement.

   132.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the air contaminant emissions from the 1,150 ton limestone storage silo of the limestone conveying and processing operation shall be controlled by a bin vent fabric collector. The air contaminant emissions from the 36" by 150` conveyor, two 525 ton limestone storage hoppers, two 36" by 50` conveyors and two milling machines of the limestone conveying and processing operation located in the boiler building shall be controlled by a bin vent fabric collector. The bin vent fabric collector associated with the limestone storage silo shall have an air flow of 200 ACFM, a maximum air to cloth ratio of 7:1 using reverse air jets cleaning system. The bin vent fabric collector associated with limestone processing within the boiler building shall have an air flow of 150 ACFM, a maximum air to cloth ratio of 7:1 using reverse air jets cleaning system.

   133.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, all conveyors of the limestone conveying and processing operation which are not entirely located inside a building shall be fully enclosed except for where the material enters and exits the conveyor, the 1,150 ton limestone storage silo of the limestone conveying and processing operation shall not operate if its bin vent fabric collector is inoperable, and the 36" by 150` conveyor, two 525 ton limestone storage hoppers, two 36" by 50` conveyors and two milling machines of the limestone conveying and processing operation shall not operate if its bin vent fabric collector is inoperable.

   134.  The permittee shall submit to the Department for approval the specific make and model and the corresponding design details of the two milling machines associated with the limestone conveying and processing operation, as well as the specific make and model of the bin vent fabric collectors and the corresponding design details within 30 days of issuing the purchase order for the specified source and control devices by submitting the appropriate pages of the plan approval application.

   135.  The limestone conveying and processing operation is subject to the Standards of Performance for New Stationary Sources, 40 CFR Part 60, Subpart OOO and shall comply with all applicable requirements as specified in 40 CFR 60.670--60.676.

   136.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the total particulate matter emitted from the cooling tower shall not exceed 1.75 pounds per hour and 7.67 tons in any 12 consecutive month period.

   137.  The permittee shall continuously monitor the circulating water flow rate in units of gpm, the circulating water's total solids content in units of parts per million and the number of cycles of concentration of the cooling tower. The permittee shall continuously record the circulating water flow rate in units of gallons per minute, the circulating water's total solids content in units of parts per million and the number of cycles of concentration of the cooling tower. The permittee shall keep records of the supporting calculations to verify compliance with the particulate matter emission limitations in pounds per hour and tons in any 12 consecutive month period. Additionally, the permittee shall submit reports to the Department on a semi-annual basis that include the supporting calculations used to verify compliance with total particulate matter emission limitation in any 12 consecutive month period.

   138.  Under the BACT of the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, each cell of the cooling tower shall be equipped with a drift eliminator. The drift eliminator located on each cell of the cooling tower shall be capable of achieving a maximum drift rate of 0.0005%.

   139.  Under the PSD provisions in 40 CFR 52.21 and of 25 Pa. Code § 127.83, as well as the BAT provisions in 25 Pa. Code § 127.1 and 127.12, the circulating water flow rate of the cooling tower shall not exceed 140,000 gpm at any time, the total solids concentration of the circulating water in the cooling tower shall not exceed 5,000 ppm at any time, and the number of cycles of concentration shall not exceed five cycles at any time. The cooling tower shall be a rectangular mechanical-draft 10 cell tower. Additionally, no chromium based water treatment chemicals shall be used in the cooling tower.

   140.  Under the LAER New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the emission of VOCs from the No. 2 fuel oil storage tank shall not exceed 1 pound per year.

   141.  Under the New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217 as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the permittee shall monitor the activated carbon indicator associated with the storage tank on a daily basis.

   142.  The permittee shall keep comprehensive and accurate records of: the readings of the activated carbon indicator associated with the storage tank on a weekly basis; and the dates that activated carbon is added to the activated carbon filters associated with the storage tank.

   143.  Under the LAER New Source Review Regulation provisions in 25 Pa. Code §§ 127.201--127.217, as well as the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the storage tank shall be equipped with activated carbon filters and a PV conservation vent at all times No. 2 fuel oil is stored in storage tank. The VOC emissions from the No. 2 fuel oil storage tank shall be controlled by the activated carbon filters through the PV conservation vent. Additionally, the permittee shall keep on hand a sufficient quantity of activated carbon canisters for the activated carbon filters associated with the storage tank in order to be able to immediately replace activated carbon upon breakthrough. Breakthrough is defined as any detectable VOC concentration emitted to the atmosphere from the carbon bed. The storage tank shall be a 50,000 gallon capacity No. 2 fuel oil tank, located above ground at the facility and the permittee shall only store No. 2 fuel oil in the No. 2 fuel oil storage tank.

   144.  All records required by this plan approval shall be kept for a minimum of 5 years and shall be made available to the Department upon request. In addition, the permittee shall report any equipment malfunctions or excess emissions to the Department.

   Copies of the application and the modeling analysis used in the evaluation of the application are available for public review between 8 a.m. and 4 p.m. at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review may be made by calling Kathy Arndt at (570) 327-3693.

   Interested persons may submit written comments, suggestions or objections concerning the proposed plan approval and alternative air dispersion modeling to the regional office within 30 days of publication of this notice. Written comments submitted to the Department during the 30-day public comment period should include the name, address and telephone number of the commentator, identification of proposed Plan Approval 17-00055A and a concise statement regarding the relevancy of the information or objections to the issuance of the plan approval or the use of the alternative model.

   A public hearing may be held, if the Department, in its discretion, decides that a hearing is warranted based on the information received. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper, the Pennsylvania Bulletin or by telephone, when the Department determines that notification by telephone is sufficient. Written comments or requests for a public hearing should be directed to Muhammad Q. Zaman, Chief, Facilities Permitting Section, Department of Environmental Protection, Air Quality Program, Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701, (570) 327-0512.

   Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodations to do so should contact the Department or the Pennsylvania AT&T Relay Service at (800) 654-5984 (TDD) to discuss how the Department may accommodate their needs.

   Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, William Charlton, New Source Review Chief, (412) 442-4174.

   PA-30-00099B: Allegheny Energy Supply Company, LLC (800 Cabin Hill, Greensburg, PA 15601) for the construction and operation of a facility to manufacture synthetic fuel (synfuel) at their existing Hatfield's Ferry Power Station in Monongahela Township, Greene County.

   Under 25 Pa. Code § 127.44(a), the Department of Environmental Protection (Department) intends to issue a Plan Approval to the Allegheny Energy Supply Company, LLC to allow the construction and operation of a facility to manufacture synthetic fuel (synfuel) at the existing Hatfield's Ferry Power Station located in Monongahela Township, Greene County.

   Based on the applicant's estimate, potential emissions from this new source are summarized in Table 1.

Table 1.  Synfuel Plant Potential Emissions.

Pollutant Pounds Per Hour Tons Per Year
PM 2.54 4.32
PM10 0.68 1.57
VOC 1.38 4.95
HAP 1.38 4.95

   Based on these potential emissions, the facility is not subject to PSD or New Source Review requirements for this change.

   Copies of the application, Department's analysis and other documents used in evaluation of the application are available for public inspection during normal business hours at the Department of Environmental Protection, 400 Waterfront Drive, Pittsburgh, PA 15222.

   For the Department to assure compliance with all applicable standards, it proposes to place the following conditions on the Plan Approval:

   1.  This Plan Approval is for the construction and operation of a facility to manufacture synthetic fuel by Allegheny Energy Supply Company, LLC at the Hatfield's Ferry Power Station located in Monongahela Township, Greene County [25 Pa. Code § 127.12b].

   2.  The Owner/Operator shall not permit the emission to the outdoor atmosphere of any malodorous air contaminants from any source, in such a manner that the malodors are detectable outside the property [25 Pa. Code § 123.31].

   3.  There shall be no fugitive emissions from the facility contrary to 25 Pa. Code §§ 123.1 and 123.2.

   4.  Coal throughput at the synthetic fuel facility shall not exceed 3,600,000 tons in any consecutive 12-month period [25 Pa. Code § 127.12b].

   5.  Liquid additive usage shall not exceed 5.5 pounds per ton of coal or 2,262,857 gallons in any consecutive 12-month period [25 Pa. Code § 127.12b].

   6.  Liquid additive VOC and HAP content shall be limited to 500 ppmw, as delivered [25 Pa. Code § 127.12b].

   7.  Each shipment of liquid additive shall be accompanied by the manufacturer's verification, or shall be tested by Allegheny Energy Supply Company, LLC, for compliance with Condition No. 8. VOC and HAP content of the liquid additive shall be verified prior to unloading [25 Pa. Code § 127.12b].

   8.  All conveyor belts at the facility shall be covered and the synthetic fuel manufacturing process shall be located within an enclosed facility [25 Pa. Code § 127.12b].

   9.  All transfer points shall be fully enclosed or equipped with water sprays capable of operation under all weather conditions [25 Pa. Code § 127.12b].

   10.  The Owner/Operator shall maintain records of daily, monthly, and 12-month rolling total for coal usage, liquid additive usage and synthetic fuel production. The records shall also include daily records of liquid additive type and liquid additive application rate [25 Pa. Code § 127.12b].

   11.  The Owner/Operator shall perform a daily inspection of the facility for the presence of fugitive and malodorous emissions. Records of the inspections shall be maintained in a log and include any corrective actions taken [25 Pa. Code § 127.12b].

   12.  All logs and required records shall be maintained on site for a minimum of 5 years and shall be made available to the Department upon request [25 Pa. Code § 127.12b].

   13.  By constructing this synthetic fuel manufacturing facility, and considering the 2003 Bottom Ash Screening Operation, the Allegheny Energy Supply Company, LLC, Hatfield's Ferry Power Station has consumed 5.0 tons for VOC of the 40-ton major modification increment, 5.5 tons for PM of the 25-ton major modification increment and 2.2 tons for PM10 of the 15-ton major modification increment [25 Pa. Code Subchapter E and 25 Pa. Code § 127.83].

   14.  This Plan Approval authorizes the temporary operation of the sources covered by this Plan Approval provided the following conditions are met [25 Pa. Code § 127.12b]:

   (a)  The Owner/Operator shall submit written Notice of the Completion of Construction and the Operator's intent to commence operation at least 5 days prior to the completion of construction. The Notice shall state the date when construction will be completed and the date when the Operator expects to commence operation.

   (b)  Operation of the sources covered by this Plan Approval is authorized only to facilitate the start-up and shakedown of sources and air cleaning devices, to permit operations pending the issuance of an Operating Permit, or to permit the evaluation of the source for compliance with all applicable regulations and requirements.

   (c)  Upon receipt of the Notice of the Completion of Construction from the Owner/Operator the Department shall authorize a 180-day Period of Temporary Operation of the sources from the date of commencement of operation. The Notice submitted by the Owner/Operator, prior to the expiration of this Plan Approval, shall modify the Plan Approval expiration date. The new Plan Approval expiration date shall be 180 days from the date of commencement of operation.

   (d)  Upon determination by the Owner/Operator that the sources covered by this Plan Approval are in compliance with all conditions of the Plan Approval the Owner/Operator shall contact the Department's reviewing engineer and schedule the Initial Operating Permit Inspection.

   (e)  Upon completion of Initial Operating Permit Inspection and determination by the Department that the sources covered by this Plan Approval are in compliance with all conditions of the Plan Approval the Owner/Operator shall submit an administrative permit amendment application, per 25 Pa. Code § 127.450, to the Department at least 60 days prior to the expiration date of the Plan Approval to incorporate the requirements of the plan approval into the Title V Operating Permit.

   (f)  The Owner/Operator may request an extension of the 180-day Period of Temporary Operation if compliance with all applicable regulations and Plan Approval requirements has not been established. The extension request shall be submitted in writing at least 15 days prior to the end of the Period of Temporary Operation and shall provide a description of the compliance status of the source. The extension request shall include a detailed schedule for establishing compliance and the reasons compliance has not been established. This Period of Temporary Operation may be extended for additional limited periods, each not to exceed 120 days, by submitting an extension request as previously described.

   (g)  If, at any time, the Department has cause to believe that air contaminant emissions from the sources listed in this plan approval may be in excess of the limitations specified in, or established under this plan approval or the permittee's operating permit, the permittee may be required to conduct test methods and procedures deemed necessary by the Department to determine the actual emissions rate. The testing shall be conducted in accordance with 25 Pa. Code Chapter 139, when applicable, and in accordance with any restrictions or limitations established by the Department at such time as it notifies the company that testing is required.

   Persons wishing to provide the Department with additional information that they believe should be considered prior to the issuance of the Plan Approval may submit the information to the Department the following address. A 30-day comment period, from the date of this publication, will exist for the submission of comments. Written comments must contain the following:

   *  Name, address, and telephone number of the person submitting the comments.

   *  Identification of the proposed Plan Approval (specify the Plan Approval number).

   *  Concise statements regarding the relevancy of the information or objections to issuance of the Plan Approval.

   Written comments should be directed to Regional Air Quality Program Manager, Department of Environmental Protection, Southwest Region--Field Operation, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

   For additional information, contact Mark Gorog, Air Quality Program, (412) 442-4333 at the previously listed address.

   Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481, George Monasky, New Source Review Chief, (814) 332-6940.

   42-061B: Dresser Manufacturing Division--Dresser Industries (41 Fisher Avenue, Bradford, PA 16701) for modification of the VOC and HAP emission limits from the Binks Spray Booth and Plastisol Dip operations at their Fisher Avenue Plant, Bradford, McKean County.

   In accordance with 25 Pa. Code §§ 127.44(b) and 127.424(b), the Department of Environmental Protection intends to issue a plan approval for modification of a plan approval to modify the VOC and HAP emission limits from the Binks Spray Booth and Plastisol Dip operations at their Fisher Avenue Plant, Bradford, McKean County. This plan approval will, in accordance with 25 Pa. Code § 127.450, be incorporated into a State Only operating permit through an administrative amendment at a later date. Issuance of the plan approval is recommended with the appropriate conditions in the plan approval.

OPERATING PERMITS


Intent to Issue Title V Operating Permits under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter G.

   Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401, Edward Jurdones Brown, Facilities Permitting Chief, (484) 250-5920.

   23-00045: Sunoco Partner Marketing and Terminal LP (4041 Market St, Aston, PA 19014) for renewal of their Title V Operating Permit in Upper Chichester Township, Delaware County. The initial permit was issued on May 18, 2000. The facility is primarily used for bulk storage and transfer of petroleum products. As a result of potential emissions of VOC, the facility is a major stationary source as defined in Title I, Part D of the Clean Air Act Amendments, and is therefore subject to the Title V permitting requirements adopted in 25 Pa. Code Chapter 127, Subchapter G. The Title V Operating Permit will contain Compliance Assurance Monitoring conditions under 40 CFR Part 64. The renewal contains all applicable requirements including monitoring, recordkeeping and reporting.

   Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711-0790, Mark Wejkszner, New Source Review Chief, (570) 826-2531.

   35-00024: Keystone Recovery, Inc. (Marshwood Road, Throop, PA 18512) for a renewal Title V Operating Permit in Throop Borough, Lackawanna County. The facility sources include a landfill gas treatment system, seven combustion engines and a compressor station. These sources have the potential to emit major quantities of regulated pollutants above Title V emission thresholds. The proposed Title V Operating Permit contains all applicable requirements including Federal and State regulations. In addition, monitoring, recordkeeping and reporting conditions regarding compliance with all applicable requirements are included.

   35-00014: Keystone Sanitary Landfill, Inc. (P. O. Box 249, Dunmore, PA 18512-0249) for a renewal Title V Operating Permit in Dunmore Borough, Lackawanna County. The facility sources include quarry operations, landfill (closed), landfill phase 1 (gas collection system); gasoline, hydraulic oil, motor oil and diesel storage tanks and a leachate pretreatment plant. These sources have the potential to emit major quantities of regulated pollutants above Title V emission thresholds. The proposed Title V Operating Permit contains all applicable requirements including Federal and State regulations. In addition, monitoring, recordkeeping and reporting conditions regarding compliance with all applicable requirements are included.

   48-00011: PPL Martins Creek SES, LLC (6605 Foul Rift Road, Bangor, PA 18013-4857) for issuance of a renewal Title IV Phase II Acid Rain Permit for their power transmission facility in Lower Mt. Bethel Township, Northampton County. The renewal Title IV Phase II Acid Rain Permit shall be incorporated as part of the renewal Title V operating permit for their facility. The facility's main sources include two bituminous coal/No. 2 fuel oil fired boilers, two No. 2 fuel oil/natural gas/No.6 fuel oil fired boilers, one natural gas fired auxiliary boiler, one No. 2 fuel oil fired auxiliary boiler, for No. 2 fuel oil fired combustion turbines and two diesel generators. The renewal Title IV Phase II Acid Rain Permit includes all applicable requirements including Federal and State regulations.

   Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, Ronald Davis, New Source Review Chief, (717) 705-4702.

   31-05001: Department of Corrections--Hunting- don State Correctional Institution (1100 Pike Street, Huntingdon, PA 16654-1112) for operation of the state correctional facility in Smithfield Township, Huntingdon County. The facility is a major source that primarily emits SOx, NOx and CO through the operation of the facility's four bituminous coal fired boilers. The Title V operating permit will contain appropriate monitoring, record keeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements. To limit HAP emissions, the facility has accepted an annual coal through put limitation of 14,000 tons. This is a renewal of their Title V operating permit.


Intent to Issue Operating Permits under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter F.

   Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19428, Edward Jurdones Brown, Facilities Permitting Chief, (484) 250-5920.

   09-00077: Exelon Generation Co.--Pennsbury Power Production Plant (1414 Bordentown Road, Morrisville, PA 19303) for operation of two combustion turbines that convert landfill gas into electric power when the demand is high in Falls Township, Bucks County. This is a non-Title V Facility, State-only, Synthetic Minor Operating Permit. The permit will include monitoring, recordkeeping, reporting and work practice standards designed to keep the facility operating within all applicable air quality requirements.

   23-00098: SAP America, Inc. (3999 West Chester Pike, Newtown Square, PA 19073) for operation of three boilers, four emergency generators and a water heater at the office building in Newtown Township, Delaware County. The permit is for a non-Title V (State-only) facility. The facility has elected to cap NOx to less than 25 tons per year each; therefore the facility is a Synthetic Minor. The permit will include monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

   46-00159: US Chrome Corp. of PA (750 West Washington Street, Norristown, PA 19401) for operation of their Chrome Electroplating facility in Norristown Borough, Montgomery County. The permit is for a non-Title V (State-only) facility. The major sources of air emissions are five plating baths and one fume scrubber. The permit will include monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

   Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, Ronald Davis, New Source Review Chief, (717) 705-4702.

   28-03045: Dominion Transmission, Inc. (625 Liberty Avenue, Pittsburgh, PA 15222) for a State-only Operating Permit at their Chambersburg Compressor Station site in Hamilton Township, Franklin County. The facility's major sources of emissions include two natural gas fired turbine-gas compressors controlled by dry low NOx combustor, rated at 7,955 hp each, which primarily emit NOx. The facility emissions of NOx shall be limited at less than 100 tons per year. Plan Approval No. 28-03045 will be incorporated into the operating permit. The operating permit will contain restrictions, work practice standards, monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

   Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481, Eric Gustafson Facilities Permitting Chief, (814) 332-6940.

   61-00208: Specialty Fabrications and Powder Coating, LLC. (455 Allegheny Boulevard, Franklin, PA 16323-0790) for operation of their sheet metal fabrication facility at Sugarcreek Borough, Venango County. The significant sources are miscellaneous natural gas usage, a paint line, drying/curing powder coating, a powder coat line and a burn off oven.

   43-00322: Thompson Fabrication (60 Council Avenue, Wheatland, PA 16161-0432) for fabrication of steel roll off dumpsters in the Borough of Wheatland, Mercer County.

COAL AND NONCOAL MINING ACTIVITY APPLICATIONS

   Applications under the Surface Mining Conservation and Reclamation Act (52 P. S. §§ 1396.1--1396.19a); the Noncoal Surface Mining Conservation and Reclamation Act (52 P. S. §§ 3301--3326); The Clean Streams Law (35 P. S. §§ 691.1--691.1001); the Coal Refuse Disposal Control Act (52 P. S. §§ 30.51--30.66); and The Bituminous Mine Subsidence and Land Conservation Act (52 P. S. §§ 1406.1--1406.21). Mining activity permits issued in response to applications will also address the applicable permitting requirements of the following statutes: the Air Pollution Control Act (35 P. S. §§ 4001--4015); the Dam Safety and Encroachments Act (32 P. S. §§ 693.1--693.27); and the Solid Waste Management Act (35 P. S. §§ 6018.101--6018.1003).

   The following permit applications to conduct mining activities have been received by the Department of Environmental Protection (Department). A copy of an application is available for inspection at the district mining office indicated before an application. Where a 401 Water Quality Certification is needed for any aspect of a particular proposed mining activity, the submittal of the permit application will serve as the request for certification.

   Written comments, objections or requests for informal conferences on applications may be submitted by any person or any officer or head of any Federal, State or local government agency or authority to the Department at the district mining office indicated before an application within 30 days of this publication, or within 30 days after the last publication of the applicant's newspaper advertisement, as provided by 25 Pa. Code §§ 77.121--77.123 and 86.31--86.34.

   Where any of the mining activities listed will have discharges of wastewater to streams, the Department will incorporate NPDES permits into the mining activity permits issued in response to these applications. NPDES permits will contain, at a minimum, technology-based effluent limitations as identified in this notice for the respective coal and noncoal applications. In addition, more restrictive effluent limitations, restrictions on discharge volume or restrictions on the extent of mining which may occur will be incorporated into a mining activity permit, when necessary, for compliance with water quality standards (in accordance with 25 Pa. Code Chapters 93 and 95). Persons or agencies who have requested review of NPDES permit requirements for a particular mining activity within the previously mentioned public comment period will be provided with a 30-day period to review and submit comments on the requirements.

   Written comments or objections should contain the name, address and telephone number of the person submitting comments or objections; the application number; and a statement of sufficient detail to inform the Department on the basis of comment or objection and relevant facts upon which it is based. Requests for an informal conference must contain the name, address and telephone number of requestor; the application number; a brief summary of the issues to be raised by the requestor at the conference; and a statement whether the requestor wishes to have the conference conducted in the locality of the proposed mining activities.

Coal Applications Received

Effluent Limits

   The following coal mining applications that include an NPDES permit application will be subject to, at a minimum, the following technology-based effluent limitations for discharges of wastewater to streams:


30-day Daily Instantaneous
Parameter Average Maximum Maximum
iron (total) 3.0 mg/l 6.0 mg/l 7.0 mg/l
manganese (total) 2.0 mg/l 4.0 mg/l 5.0 mg/l
suspended solids 35 mg/l      70 mg/l      90 mg/l     
pH1 greater than 6.0; less than 9.0
alkalinity greater than acidity1

1 The parameter is applicable at all times.

   A settleable solids instantaneous maximum limit of 0.5 ml/l applied to: (1) surface runoff (resulting from a precipitation event of less than or equal to a 10-year 24-hour event) from active mining areas; active areas disturbed by coal refuse disposal activities; and mined areas backfilled and revegetated; and (2) drainage (resulting from a precipitation event of less than or equal to a 1-year 24-hour event) from coal refuse disposal piles.

   California District Mining Office: 25 Technology Drive, Coal Center, PA 15423, (724) 769-1100.

   30841319 and NPDES Permit No. PA0043559, Consolidation Coal Company, (1 Bridge Street, Monongah, WV 26554), to revise the permit for the Blacksville Mine No. 1 in Wayne and Greene Townships, Greene County to inject coal bed methane well water into the mine pool. No additional discharges. Application received March 23, 2005.

[Continued on next Web Page]



No part of the information on this site may be reproduced for profit or sold for profit.

This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.