PUBLIC WATER SUPPLY (PWS) PERMIT

   Under the Pennsylvania Safe Drinking Water Act (35 P. S. §§ 721.1--721.17), the following parties have applied for a PWS permit to construct or substantially modify a public water system.

   Persons wishing to comment on a permit application are invited to submit a statement to the office listed before the application within 30 days of this public notice. Comments received within the 30-day comment period will be considered in the formulation of the final determinations regarding the application. Comments should include the name, address and telephone number of the writer and a concise statement to inform the Department of Environmental Protection (Department) of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.

   Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.

   The permit application and any related documents are on file at the office listed before the application and are available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.

   Persons with a disability who require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

SAFE DRINKING WATER


Applications Received Under the Pennsylvania Safe Drinking Water Act

   Southeast Region: Water Supply Management Program Manager, 2 East Main Street, Norristown, PA 19401.

   Permit No 4606507, Public Water Supply

Applicant Aqua Pennsylvania, Inc.
Township Lower Merion
County Montgomery
Responsible Official Joseph A. Ritter
Type of Facility PWS
Consulting Engineer N/A
Application Received Date September 8, 2006
Description of Action Installation of a Solar Bee mixing system and related control equipment for applying disinfection in an existing storage tank.

   Southcentral Region: Water Supply Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.

   Permit No. 3606509, Public Water Supply.

Applicant Bailey Family Partnership
Municipality Mount Joy Borough
County Lancaster
Responsible Official Charles G. Bailey Jr.
Owner Operator
1501 Mill Road
Elizabethtown, PA 17022
Type of Facility Public Water Supply
Consulting Engineer Eugene R. Oldham, P. E.
DC Gohn Associates, Inc.
32 Mount Joy Street
Mount Joy, PA 17552
Application Received: 6/20/2006
Description of Action Installation of a chlorination system at Well No. 6 to serve a section of the existing Lake View MHP.

   Northwest Region: Water Supply Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

   Application No. 2006501, Public Water Supply

Applicant Hydetown Court Mobile Home Park
Township or Borough Hydetown Borough
Crawford County
Responsible Official Thomas E. Kalkhof, President
Housing & Investment Properties, Inc.
Consulting Engineer Donald P. Trant, P. E.
Trant Corporation
11279 Perry Hwy.
Suite 110
Wexford PA 15090
Application Received Date 09/12/2006
Description of Action Permitting of previously unpermitted water system with service to the Hydetown Court Mobile Home Park.

MINOR AMENDMENT


Applications Received Under the Pennsylvania Safe Drinking Water Act

   Northeast Region: Water Supply Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.

   Application No. Minor Amendment, Public Water Supply.

Applicant Mountain Lake Water Co., LLC
Palmyra Township
Pike County
Responsible Official Bonnie Cabel-Rotella
Mountain Lake Water Co., LLC
P. O. Box 551
Tafton, PA 18464
Type of Facility PWS
Consulting Engineer N/A
Application Received Date August 24, 2006
Description of Action Transfer of PWS Permit 5294501 issued October 14, 1997 from Blue Horseshoe Investment Co., Inc. to Mountain Lake Water Co., LLC

   Southwest Region: Water Supply Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

   Application No. 5606502MA, Minor Amendment.

Applicant Seven Springs Municipal Authority
290 Lagoon Lane
Champion, PA 15622
Township or Borough Saltlick Township
Responsible Official Sarah Eutsey, Manager
Seven Springs Municipal Authority
290 Lagoon Lane
Champion, PA 15622
Type of Facility Water storage tank
Consulting Engineer Widmer Engineering
225 West Crawford Avenue
Connellsville, PA 15425
Application Received Date June 1, 2006
Description of Action Replacement of the existing 300,000 gallon Lake Tahoe water storage tank with new post tensioned 500,000 gallon water storage tank.

WATER ALLOCATIONS


Applications received under the act of June 24, 1939 (P. L. 842, No. 365) (35 P. S. §§ 631--641) relating to the acquisition of rights to divert waters of this Commonwealth

   Northwest Region: Water Supply Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

   WA 10-1006A, Water Allocation. Municipal Authority of Adams Township, 690 Valencia Road, P. O. Box 807, Mars, PA 16046, Adams Township, Butler County. Modification to existing Water Allocation Permit extending the service area to include Callery Borough and portions of Forward Township. As proposed, the modification will not increase the allocation amount as authorized under a valid agreement with the Borough of West View.

LAND RECYCLING AND ENVIRONMENTAL REMEDIATION

UNDER ACT 2, 1995

PREAMBLE 1


Acknowledgment of Notices of Intent to Remediate Submitted under the Land Recycling and Environmental Remediation Standards Act (35 P. S. §§ 6026.101--6026.908).

   Sections 302--305 of the Land Recycling and Environmental Remediation Standards Act (act) require the Department of Environmental Protection (Department) to publish in the Pennsylvania Bulletin an acknowledgment noting receipt of Notices of Intent to Remediate. An acknowledgment of the receipt of a Notice of Intent to Remediate is used to identify a site where a person proposes to, or has been required to, respond to a release of a regulated substance at a site. Persons intending to use the Background Standard, Statewide Health Standard, the Site-Specific Standard or who intend to remediate a site as a special industrial area must file a Notice of Intent to Remediate with the Department. A Notice of Intent to Remediate filed with the Department provides a brief description of the location of the site, a list of known or suspected contaminants at the site, the proposed remediation measures for the site and a description of the intended future use of the site. A person who demonstrates attainment of one, a combination of the cleanup standards or who receives approval of a special industrial area remediation identified under the act will be relieved of further liability for the remediation of the site for any contamination identified in reports submitted to and approved by the Department. Furthermore, the person shall not be subject to citizen suits or other contribution actions brought by responsible persons not participating in the remediation.

   Under sections 304(n)(1)(ii) and 305(c)(2) of the act, there is a 30-day public and municipal comment period for sites proposed for remediation using a Site-Specific Standard, in whole or in part, and for sites remediated as a special industrial area. This period begins when a summary of the Notice of Intent to Remediate is published in a newspaper of general circulation in the area of the site. For the sites identified, proposed for remediation to a Site-Specific Standard or as a special industrial area, the municipality within which the site is located may request to be involved in the development of the remediation and reuse plans for the site if the request is made within 30 days of the date specified. During this comment period, the municipality may request that the person identified as the remediator of the site develop and implement a public involvement plan. Requests to be involved and comments should be directed to the remediator of the site.

   For further information concerning the content of a Notice of Intent to Remediate, contact the environmental cleanup program manager in the Department regional office before which the notice appears. If information concerning this acknowledgment is required in an alternative form, contact the community relations coordinator at the appropriate regional office. TDD users may telephone the Department through the AT&T Relay Service at (800) 654-5984.

   The Department has received the following Notices of Intent to Remediate:

   Northeast Regional Field Office: Ronald S. Brezinski, Regional Environmental Cleanup Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790, (570) 826-2511.

   Victoria Square V, Palmer Township, Northampton County. Tony Dellaria, MEA, Inc., 1365 Ackermanville Road, Bangor, PA 18013 has submitted a Notice of Intent to Remediate (on behalf of his client, Nicholas Pugliese, Victoria Place, Inc., 1072 Grand Street, Phillipsburg, NJ 08865) concerning disposal of material contaminated with inorganics and benzo(a)pyrene on the referenced property. The applicant proposes to remediate the site to meet the Site-Specific Soil Standard by limited source removal and pathway elimination. Future use of the property will be residential. A summary of the Notice of Intent to Remediate was published in the Pocono Record on August 5, 2006.

   Former Techneglas Facility, Jenkins Township, Luzerne County. Mike Antonetti, P. G., Malcolm Pirnie Inc., 1603 Carmody Court, Suite 403, Sewickley, PA 15143 has submitted a Notice of Intent to Remediate (on behalf of his client, Marvin Katz, TGPIT, Inc., 4300 Walnut St., Westerville, OH 43081) concerning residual concentrations of inorganics in soils used in former site operations and petroleum hydrocarbons as the result of historic releases. The applicant proposes to remediate the site to meet the Site-Specific Soil and Groundwater Standard. Future use of the property will be industrial and/or for warehousing purposes. A summary of the Notice of Intent to Remediate is expected to be published in a local newspaper serving the local area sometime in the near future.

   Southcentral Region: Environmental Cleanup Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.

   Rite Aid Store 3608, Harrisburg City, Dauphin County. BL Companies, 213 Market Street, 6th Floor, Harrisburg, PA 17101, on behalf of Rite Aid Corporation, 30 Hunter Lane, Camp Hill, PA 17011, submitted a Notice of Intent to Remediate site soils and groundwater contaminated by petroleum compounds leaked during removal of USTs. The property was formerly two gas stations and is currently occupied by a Rite Aid Pharmacy and will remain the same in the future. The applicant seeks to remediate to both the Statewide Health and Site-Specific Standards.

   Lydia Fisher Property, Earl Township, Lancaster County. GCI Environmental Services, 1250 East King Street, Lancaster, PA 17602, on behalf of Lydia Fisher, 3007 Newport Road, Ronks, PA 17572-9725, submitted a Notice of Intent to Remediate site soils and groundwater contaminated by gasoline leaked during removal of a UST. The property was a former garage that has been demolished and the future use of the property is residential. The applicant seeks to remediate to the Site-Specific Standard.

   GF Capital--901 North 7th Street, Harrisburg City, Dauphin County. RT Environmental Services, Inc., Pureland Complex, Suite 306, 510 Heron Drive, Bridgeport, NJ 08014, on behalf of GF Capital Real Estate Fund, LP, 375 Park Avenue, 17th Floor, New York, NY 10152-1799, submitted a Notice of Intent to Remediate site soils and groundwater contaminated by kerosene leaked during removal of an AST. The property is commercial and will remain commercial in the future. The applicant seeks to remediate to the Residential Statewide Health Standard.

   Shultz Enterprises Property Lot 3 (former), Hanover Borough, York County. Taylor GeoServices, Inc., 938 Lincoln Avenue, Suite 203, Springfield, PA 19064, on behalf of Walt Green LLC, 4440 Hay Drive, Manchester, MD 21102-1148, submitted a Notice of Intent to Remediate site soils and groundwater contaminated by petroleum hydrocarbons associated with gasoline, waste oil and hydraulic oil. The property was a former car dealership and is currently a commercial car wash and will remain a car wash in the future. The applicant seeks to remediate to the Statewide Health Standard.

   Estate of Arthur F. Walters, Russ's Auto Repair Shop, Manheim Township, Lancaster County. ARM Group, Inc., 1129 West Governor Road, P. O. Box 797, Hershey, PA 17033-0797, on behalf of Chester and Miller, LLP Legal Council, 150 North Queen Street, Suite 600, Lancaster, PA 17603-1805, submitted a Notice of Intent to Remediate site soils and groundwater contaminated by gasoline constituents that were released from two USTs removed in 1999. The property was used for commercial activities and the future use is for commercial activities. The applicant seeks to remediate to the Statewide Health Standard.

   Northwest Region: Environmental Cleanup Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

   Ave Maria--St. Marys, Benzinger Township, Elk County. KLH Engineers Inc., 5173 Campbells Run Road, Pittsburgh, PA 15205, on behalf of the City of St. Marys, 808 South Michael Road, Saint Marys, PA 15857 has submitted a Notice of Intent to Remediate. The proposed remediation of soil is to remove cadmium and reach levels that comply with the Site-Specific Standards. The current use of the property is residential and will continue to be used as residential.

   North Michael Street--St. Marys, St. Marys, Elk County, KLH Engineers Inc., 5173 Campbells Run Road, Pittsburgh, PA 15205, on behalf of the City of St. Marys, 808 South Michael Road, St. Marys, PA 15857 has submitted a Notice of Intent to Remediate. The proposed remediation of soil is to remove cadmium and reach levels that comply with the Site-Specific Standards. The current use of the property is residential and will continue to be used as residential.

   Windfall Road--St. Marys, Benzinger Township, Elk County, KLH Engineers Inc., 5173 Campbells Run Road, Pittsburgh, PA 15205, on behalf of the City of St. Marys, 808 South Michael Road, St.Marys, PA 15857 has submitted a Notice of Intent to Remediate. The proposed remediation of soil is to remove cadmium and reach levels that comply with the Site-Specific Standards. The current use of the property is residential and will continue to be used as residential.

AIR QUALITY

PLAN APPROVAL AND OPERATING PERMIT APPLICATIONS

NEW SOURCES AND MODIFICATIONS

   The Department of Environmental Protection (Department) has developed an ''integrated'' plan approval, State operating permit and Title V operating permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the public. This approach allows the owner or operator of a facility to complete and submit all the permitting documents relevant to its application one time, affords an opportunity for public input and provides for sequential issuance of the necessary permits.

   The Department has received applications for plan approvals and/or operating permits from the following facilities.

   Copies of the applications, subsequently prepared draft permits, review summaries and other support materials are available for review in the regional office identified in this notice. Persons interested in reviewing the application files should contact the appropriate regional office to schedule an appointment.

   Persons wishing to receive a copy of a proposed plan approval or operating permit must indicate their interest to the Department regional office within 30 days of the date of this notice and must file protests or comments on a proposed plan approval or operating permit within 30 days of the Department providing a copy of the proposed document to that person or within 30 days of its publication in the Pennsylvania Bulletin, whichever comes first. Interested persons may also request that a hearing be held concerning the proposed plan approval and operating permit. Comments or protests filed with the Department regional offices must include a concise statement of the objections to the issuance of the Plan approval or operating permit and relevant facts which serve as the basis for the objections. If the Department schedules a hearing, a notice will be published in the Pennsylvania Bulletin at least 30 days prior the date of the hearing.

   Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office identified before the application. TDD users should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

   Final plan approvals and operating permits will contain terms and conditions to ensure that the source is constructed and operating in compliance with applicable requirements in 25 Pa. Code Chapters 121--143, the Federal Clean Air Act (act) and regulations adopted under the act.

PLAN APPROVALS


Plan Approval Applications Received under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter B that may have special public interest. These applications are in review and no decision on disposition has been reached.

   Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481, George Monasky, New Source Review Chief, (814) 332-6940.

   25-053B: Urick Foundry Co. (1501 Cherry Street, Erie, PA 16502) for replacement of the existing cupola and control devices with the installation of two new coreless electric induction furnaces and baghouse system in City of Erie, Erie County. This is a State-only facility.

   33-160B: Reynoldsville Casket Co., Inc. (P. O. Box 68 560 Myrtle Street Reynoldsville, PA 15851-0068) for modification to plan approval PA 33-0160A to change the primer booth from water based solvent to a volatile based primer with the emissions from process being controlled by the existing thermal oxidizer by at the casket manufacturing and finishing operation in Reynoldsville, Jefferson County. The facility currently has a State-only Operating Permit.

   Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, William Charlton, New Source Review Chief, (412) 442-4174.

   26-00562A: Coastal Lumber Company (3302 Lobban Place, Charlottesville, VA 22903) to construct a 14.4 million Btu heat input per hour wood fueled boiler at the Hopwood Sawmill in South Union Township, Fayette County.

   Department of Public Health, Air Management Services: 321 University Avenue, Philadelphia, PA 19104, Edward Braun, Chief, (215) 685-9476.

   AMS 05044: Mutual Pharmaceutical Co., Inc. (1100 Orthodox Street, Philadelphia, PA 19124) for installation of four dust collectors, two tray drying ovens and four natural gas boilers and water heaters under 10 million Btu/hr. There will be a potential emission increase of 2.02 tons for NOx and 0.04 ton for PM for the facility. The plan approval will contain operating and recordkeeping requirements to ensure operation within all applicable requirements.


Intent to Issue Plan Approvals and Intent to Issue or Amend Operating Permits under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter B. These actions may include the administrative amendments of an associated operating permit.

   Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401, Thomas McGinley, New Source Review Chief, (484) 250-5920.

   15-0104C: Tasty Baking Oxford, Inc. (700 Lincoln Street, Oxford, PA 19363) for the proposed addition of two baking ovens and production lines to an existing facility and the proposed conversion of production line No. 4 to only nonyeast leavening products. The emission limit for the production lines of 48.8 tons of VOCs per 12-month rolling sum remains the same through this action, but the application of the limit only includes Production Line No. 1, Production Line No. 3 and the two proposed baking ovens. The facility is in Oxford Borough, Chester County.

   46-0241A: Gibraltar Rock, Inc. (355 Newbold Road, Fairless Hills, PA 19030-4314) for issuance of a Plan Approval to construct a nonmetallic mineral processing plant and install two wet suppression systems. The rock crushing plant will be located off Route 73 (Big Road) between Route 663 and Church Road, New Hanover Township, Montgomery County. The crushing plant will consist of the following air contamination sources: primary crushing system, secondary crushing system, tertiary crushing system, paved and unpaved roads, and stockpiles. The rock crushing plant shall be limited to processing a maximum of 500,000 tons of rocks per year (on a 12-month rolling sum basis). The facility is a minor source for PM, PM10 and PM2.5. The crushers, screens and conveyors are subject to 40 CFR Part 60 Subpart OOO of the Standards of Performance for New Stationary Sources.

   The permittee will incorporate the following control measures and work practice standards as BAT:

   (a)  Secondary and tertiary crushers shall be enclosed on all four sides.

   (b)  All screens shall be enclosed on all sides.

   (c)  The primary crusher shall be enclosed on three sides.

   (d)  All conveyors shall be fully covered (with access doors for maintenance).

   (e)  All paved roads shall be vac swept (vacuumed and swept to remove silt from the surface of the road) and wetted on daily basis when the plant is operating.

   (f)  Unpaved roads shall be limited to the quarry area and the overburden transport roads.

   (g)  Unpaved roads shall be wetted on daily basis when the plant is operating.

   (h)  A wheel washing station shall be installed at the transition point from the unpaved area to the paved road. All wheels of vehicles entering the paved roads from an unpaved area shall be washed irrespective of weather condition.

   (i)  Both sides of the paved roads shall have vegetative cover to reduce wind erosion of soil cover and to minimize silt loading of the roads. The Department of Environmental Protection may request additional vegetative cover if silt re-entrainment is determined to cause fugitive emissions. Vegetative cover shall be provided/planted before the crushing plant starts operation irrespective of weather condition.

   (j)  All loaded trucks leaving the facility shall be tarped.

   (k)  Nozzles of the wet suppression systems shall be located at all fugitive emission points (crushers and belt conveyor transfer points).

   (l)  All fugitive emissions from the belt conveyor transfer points shall be limited to 10% opacity and all fugitive emissions from the crushers without a capture system shall be limited to 15% opacity.

   The permittee will comply with the monitoring, recordkeeping, reporting and work practice standards to keep the facility operating within all applicable air quality requirements.

   15-0124: MacKissic, Inc. (P. O. Box 111, Parker Ford, PA 19457), for installation of the paint surface coating spray booth (spray booth) with dry particulate filtering system and the infrared drying oven (oven) at the MacKissic lawn and garden equipment manufacturing new facility at 1189 Old Schuylkill Road, East Coventry Township, Chester County. The installation of the spray booth and oven may result in the emissions of: 5.89 tons per year of VOCs; 2.36 tons per year of HAPs; and 0.6 ton per year of PM. The Plan Approval and Operating Permit will contain additional recordkeeping and operating restrictions designed to keep the facility operating within all applicable air quality requirements.

   Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711-0790, Mark Wejkszner, New Source Review Chief, (570) 826-2531.

   39-309-066: Lafarge North America (5160 Main Street, Whitehall, PA 18052) for replacement/installation of nine air cleaning devices (fabric collectors) for the existing clinker reclaim belt conveyor system and for construction of a pebble lime silo and associated air cleaning device (fabric collector). The particulate emissions from each fabric collector will not exceed the Best Available Technology standard of 0.015 grain/dscf. The installation of all ten fabric collectors will result in a total maximum particulate emission rate of 10.4 tons per year. The Plan Approval and Operating Permit will contain emission restrictions, work practice standards and monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements. The facility currently has a Title V Operating Permit No. 39-00011. This plan approval will, in accordance with 25 Pa. Code § 127.450, be incorporated into the Title V Operating Permit through an administrative amendment at a later date.

   Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, Ronald Davis, New Source Review Chief, (717) 705-4702.

   22-05034F: Pennsy Supply, Inc. (1001 Paxton Street, P. O. Box 3331, Harrisburg, PA 17104-3331 for construction of a second mill at the pulverized mineral processing operation, Hummelstown Quarry, in South Hanover Township, Dauphin County. This plan approval will include appropriate restrictions and requirements designed to keep the source operating within all applicable air quality requirements. Estimated atmospheric emissions for the project for PM10, SOx, CO, NOx, VOCs, HAPs and metal/metal compounds are projected to be 20.4, 1.20, 52.00, 10.40, 12.80, 0.08 and 0.01 tpy, respectively. The project is subject to 40 CFR Part 60--Standards of Performance for New Stationary Sources.

   36-05115A: MGS, Inc. (178 Muddy Creek Church Road, Denver, PA 17517) for construction of a new in-line surface coating and curing system in East Cocalico Township, Lancaster County. The new surface coating operations will increase the facility's annual emissions of VOCs by about 4.1 tpy. The plan approval and State-only operating permit will include emission restrictions, monitoring, recordkeeping, reporting and work practice requirements designed to keep the source operating within all applicable air quality requirements.

   67-05004M: P. H. Glatfelter Co. (228 South Main Street, Spring Grove, PA 17362-0500) for production of new products on the facility's paper machines in Spring Grove Borough, York County. The Plan Approval will limit the increase of VOC to 25 tons. The Plan Approval will include monitoring, recordkeeping, reporting and work practice standards designed to keep the facility operating within all applicable air quality requirements.

   Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701, David Aldenderfer, Program Manager, (570) 327-3637.

   08-00003: CraftMaster Manufacturing, Inc. (P. O. Box 311, Towanda, PA 18848) for modification of boiler No. 3 and associated dry fuel handling equipment at their Towanda plant in Wysox Township, Bradford County.

   Under 25 Pa. Code § 127.44, the Department of Environmental Protection (Department) provides notice that CraftMaster Manufacturing, Inc. (P. O. Box 311, Towanda, PA 18848) has submitted to the Department a plan approval application for the following modifications of boiler no. 3 and associated dry fuel handling equipment at the Towanda plant located in Wysox Township, Bradford County: increase the annual average steam rate from 125,000 lbs/hr to 150,000 lbs/hr with a corresponding increase in the annual average heat input from 190.4 mmBtu/hr to 233.4 mmBtu/hr, increase the 24-hour average heat input rate from 242.4 mmBtu/hr to 273.2 mmBtu/hr, and increase the throughput to dry fuel handling equipment from 136,700 dry tons per year to 201,702 dry tons per year. The respective facility is a major facility for which a Title V operating permit (08-00003) has been issued. The Department intends to issue a plan approval to authorize the applicant to perform the modifications.

   The proposed modifications have the potential to emit the following type and amount of air contaminants: CO--344.7 tons in any 12-consecutive month period, VOC--35.3 tons in any 12-consecutive month period, NO--201.7 tons in any 12-consecutive month period, PM--44 tons in any 12-consecutive month period, PM10--24.5 tons in any 12-consecutive month period, SOx--56.9 tons in any 12-consecutive month period, hydrogen chloride--35.8 tons in any 12-consecutive month period, mercury--6.8 lbs in any 12-consecutive month period and approximately 9.6 tons per year of ammonia. In addition, the proposed throughput increase to dry fuel handling equipment would result in a PM emission increase of 2.7 tons per year and 2.5 tons per year of PM10.

   The Department's review of the information contained in the application indicates that the proposed boiler modifications will comply with all applicable requirements pertaining to air contamination sources and the emission of air contaminants including the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the requirements of 40 CFR Part 60, Subpart Db--Standards of Performance for Industrial-Commercial-Institutional Steam Generating Units and 25 Pa. Code §§ 123.11, 123.13 and 123.41. Based on this finding, the Department intends to issue a plan approval for the proposed modifications. Additionally, if the Department determines that the sources and the air cleaning devices are operating in compliance with the plan approval conditions, the conditions established in the plan approval will be incorporated into the operating permit by means of an administrative amendment under 25 Pa. Code § 127.450.

   The Department proposes to place in the plan approval the following conditions to ensure compliance with all applicable regulatory requirements:

   1.  The conditions contained in Title V operating permit 08-00003 remain in effect unless superseded or amended by conditions contained herein. If there is a conflict between a condition or requirement contain in this plan approval and a condition or requirement contained in Title V operating permit 08-00003, the permittee shall comply with the condition or requirement contained in this plan approval rather than the conflicting condition or requirement contained in Title V Operating Permit 08-00003.

   2.  This condition supersedes condition no. 010 of Source ID 033 of Title V operating permit 08-00003 under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the air contaminant emissions from the boiler shall be controlled by the following:

   (a)  Four circular type Babcock and Wilcox Co. low NOx suspension wood dust/natural gas burners.

   (b)  A Research Cottrell (under license from Fuel Tech NV) selective noncatalytic reduction (SNCR) NOxOUT control system containing four nozzles by Fuel Tech NV in ''zone 3'' at the orientations specified in the application materials (except as authorized in this plan approval).

   (c)  a Zurn Air Systems Division model no. MTSA-96-11.5CYT-XD-N/R-TA multiclone. The multiclone shall handle no more than 153,600 acfm of exhaust.

   (d)  A SES/Walther model no. 1P2CH1C11D3F/12*31.5*31.5(3@10.5) dry single stage electrostatic precipitator (ESP) following the multiclone. The ESP shall handle no more than 160,400 acfm of exhaust (combined exhaust from boiler Nos. 2 and 3).

   3.  This condition supersedes condition No. 001 of Source ID 033 of Title V operating permit 08-00003. Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the following air contaminant emissions from boiler No. 3 shall not exceed the following:

   a.  NOx--133 ppmdv at 7% oxygen (30-day rolling average).

   b.  SO2--0.0557 lb/mmBtu.

   c.  CO--430 ppmdv at 7% oxygen (30-day rolling average).

   d.  VOCs--0.0345 lb/mmBtu.

   e.  PM--0.043 lb/mmBtu.

   f.  PM--0.024 lbs/mmBtu.

   g.  Opacity equal to or greater than 15% for a period or periods aggregating more than 3 minutes in any 1 hour or equal to or greater than 50% at any time.

   h.  Ammonia (NH3)--15.2 ppmdv

   i.  Hydrogen chloride--0.035 lb/mmBtu (based on fuel analysis) and 35.8 tons in any 12-consecutive month period.

   j.  Mercury--3.34e-06 lbs/mmBtu (based on fuel analysis) and 6.8 lbs in any 12-consecutive month period.

   Boiler No. 3 need not comply with the PM and opacity emission limitations listed previously during any occasion when boiler Nos. 2 or 3 and the associated electrostatic precipitator are being purged. However, during those times the PM and opacity limitations of 25 Pa. Code §§ 123.11 and 123.41 must be met.

   4.  Under 40 CFR 60.43b(f), the opacity of the boiler No. 3 exhaust shall not be greater than 20% (6-minute average), except for one 6-minute period per hour of not more than 27%.

   5.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the PM concentration of the exhaust of the dry wood silo baghouse (Control Device ID N62 of Source ID 155P of Title V operating permit 08-00003) associated with the dry wood silo (Source ID 155P of Title V operating permit 08-00003) shall not exceed 0.010 grain per dry standard cubic foot.

   6.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the PM concentration of the exhausts of the coated fuel silo fabric collector (Control Device ID BVB01 of Source ID 194P of Title V operating permit 08-00003) and the dry fuel metering bin fabric collector (Control Device ID BVB02 of Source ID 195P of Title V operating permit 08-00003) associated with the coated fuel silo (Source ID 194P of Title V operating permit 08-00003) and the dry fuel metering bin (Source ID 195P of Title V operating permit 08-00003) shall not exceed 0.020 grain per dry standard cubic foot.

   7.  This condition supersedes condition No. 006 of Section C of Title V operating permit 08-00003. Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the combined total emissions from boiler Nos. 1--3, the line I first stage dryers (combustion only) and the line I second stage dryers (combustion only) shall not exceed the following emission rates:

   a.  CO--344.7 tons in any 12-consecutive month period.

   b.  VOCs--35.3 tons in any 12-consecutive month period.

   c.  NOx--201.7 tons in any 12-consecutive month period or 172 tons in any 12-consecutive month period based on the results of the NOx set point plan referenced in this plan approval; the final limit will be incorporated into the operating permit.

   d.  PM--44 tons in any 12-consecutive month period.

   e.  PM10--24.5 tons in any 12-consecutive month period.

   f.  SOx--56.9 tons in any 12-consecutive month period.

   8.  Under 25 Pa. Code Chapter 145, Subchapter A, the heat input from natural gas and propane shall not exceed 50% of the annual heat input to boiler No. 3.

   9.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, supplemental outside (such as, not generated onsite) wood burned in boiler no. 3 shall not contain chlorinated materials or sulfur containing materials. The burning of coated wood shall be limited to that generated by the permittee. No pressure treated wood fuel shall be burned in boiler No. 3.

   10.  Under the source monitoring provisions in 25 Pa. Code §§ 139.101 and 139.103, the permittee shall obtain Phase I approval (for both the 15% BAT limit and the 20% NSPS/MACT limit) from the Department's Continuous Compliance Section for the continuous emission monitoring system (CEMS) for opacity from boiler No. 3 within 180 days of issuance of this plan approval.

   11.  Under the source monitoring provisions in 25 Pa. Code §§ 139.101 and 139.103, the required relative accuracy testing shall be completed on the opacity CEMS and the opacity CEMS shall be fully certified in accordance with the Department's ''Continuous Source Monitoring Manual'' within 270 days of Phase I approval.

   12.  The permittee shall install and maintain instrumentation to continuously and accurately measure the pressure drop across each of the three fabric collectors of the dry fuel handling equipment (dry wood silo baghouse, coated fuel silo fabric collector and the dry fuel metering bin fabric collector) to assure proper operation of each fabric collector and to determine the need for filter replacement. The pressure drops shall be recorded at least once each week along with any corrective actions taken if any pressure drop is outside the fabric collector's design pressure drop range. The records shall be maintained for a minimum of 5 years and shall be made available to the Department upon request.

   13.  The permittee shall manage and monitor the secondary voltages and rapping frequencies of the ESP (SES/Walther model no. 1P2CH1C11D3F/12*31.5*31.5 (3@10.5)) with the Eurocard Management System by Forry, Inc. The ESP shall be operated in ''Best Opacity Control'' mode as specified by Forry, Inc. in the application materials submitted to the Department. The permittee shall keep accurate records of the rapping frequencies and the secondary voltages of each T-R set to assure that the ESP is operated and maintained in accordance with good air pollution control practices. The records shall be maintained for a minimum of 5 years and shall be made available to the Department upon request.

   14.  The permittee shall install and maintain instrumentation to continuously and accurately measure the pressure drop across the boiler No. 3 multiclone (Zurn Air Systems Division model no. MTSA-96-11.5CYT-XD-N/R-TA) to assure that the multiclone is operated and maintained in accordance with good air pollution control practices. The pressure drop shall be recorded at least once each day along with any corrective actions taken if the pressure drop is outside the multiclone's design pressure drop range. The records shall be maintained for a minimum of 5 years and shall be made available to the Department upon request.

   15.  The permittee shall replace two existing thermocouples (TE-067 and TE-068) in boiler No. 3 with two new type S thermocouples (National Basic Sensor model no. UV-S-I-86-8-43"-M-F-Z-NST). The two thermocouple readings shall be averaged-average furnace temperature (AFT). The thermocouple readings shall be continuously recorded. The records shall be maintained for a minimum of 5 years and shall be made available to the Department upon request. In addition, the thermocouples shall be calibrated annually.

   16.  The permittee shall maintain instrumentation to continuously and accurately measure the flow rate of NOxOUT-HP(r) reagent to boiler No. 3. The permittee shall keep records of the NOxOUT-HP(r) injection rate (in gallons per hour) at least once every 15 minutes. The records shall be maintained for a minimum of five years and shall be made available to the Department upon request.

   17.  Within 180 days of issuance of this plan approval, the permittee shall perform stack testing to determine compliance with the PM emission limitation of 0.010 gr/dscf from the dry wood silo baghouse (Control Device ID N62 of Source ID 155P of Title V operating permit 08-00003) associated with the dry wood silo (Source ID 155P of Title V operating permit 08-00003) and 0.020 gr/dscf from the coated fuel silo fabric collector (Control Device ID BVB01 of Source ID 194P of Title V operating permit 08-00003) and the dry fuel metering bin fabric collector (Control Device ID BVB02 of Source ID 195P of Title V operating permit 08-00003) associated with the coated fuel silo (Source ID 194P of Title V operating permit 08-00003) and the dry fuel metering bin (Source ID 195P of Title V operating permit 08-00003). Stack testing shall be performed in accordance with the applicable provisions of 25 Pa. Code Chapter 139 (relating to sampling and testing) using test methods and procedures approved by the Department. Testing shall be performed when boiler No. 3 and the associated fuel handling sources are operating at maximum capacity (approximately 273.2 mmBtu/hr).

   18.  Within 180 days of issuance of this plan approval, the permittee shall perform stack testing on boiler No. 3 to determine compliance with the PM, PM10, VOC and SO2 emission limitations. Stack testing shall be performed in accordance with the applicable provisions of 25 Pa. Code Chapter 139 (relating to sampling and testing) using test methods and procedures approved by the Department. Testing shall be performed when boiler no. 3 is operating at maximum capacity (approximately 273.2 mmBtu/hr).

   19.  Within 9 weeks of the issuance of this plan approval, the permittee shall complete Part I of the NOx set-point plan dated August 25, 2006. If the calculated removal efficiency between the uncontrolled NOx concentration and a set point of 100 ppmdv at 7% oxygen is less than 70%, the permittee shall complete Part II of the NOx set-point plan within 13 weeks of completing Part I. If the target NOx stack test at > 90% of MCR shows ammonia emissions less than or equal to 15.2 ppmdv, then the set-point shall be 100 ppmdv at 7% oxygen and the annual NOx emission limit 172 tons in any 12 consecutive month period. If the results show that it would take greater than 70% NOx removal to achieve a NOx set point of 100 ppmdv at 7% oxygen, the permittee may request, in writing, that the NOx set-point remain at 115 ppmdv at 7% oxygen with a corresponding annual NOx limit of 201.7 tons in any 12 consecutive month period. However, the permittee shall still perform ammonia stack testing within 180 days of the issuance of this plan approval to determine compliance with the 15.2-ppmdv ammonia limit at maximum boiler capacity (approximately 273.2 mmBtu/hr). The permittee shall report the results of Part I to the Department within 10 days of completion. The Department will respond in writing to a request that the NOx set-point remain at 115 ppmdv if valid test results show that it would require a removal efficiency greater than 70% to achieve the lower set-point.

   During uncontrolled NOx testing, fuel shall not be used that contains higher nitrogen containing compound content than what is normally burned. Records shall be kept that verify the consistency of the nitrogen containing compound content of the fuels burned before and during testing along with a signed statement by the responsible official that the fuels burned during testing did not contain higher than typical nitrogen containing compounds.

   During ammonia stack testing, normal urea flow rates shall be injected based on the steam flow and NOx set-point control logic documentation submitted for this plan approval. Records shall be kept showing the urea flow rates and verifying that the rates are typical.

   The permittee shall make whatever urea injection nozzle changes (replacement or relocation) needed to meet the NOx set point and the ammonia limit, and upon completion of nozzle changes shall document such changes to the Department along with any changes in urea usage rates. If it is necessary for urea flow rates to increase beyond that injected during the required testing, the permittee shall propose a timeline for additional ammonia stack testing. In addition, the existing approved NOx CEMS shall continue to operate and accurately measure and record NOx emissions, except for the 3-hour uncontrolled NOx testing period if the uncontrolled NOx concentration is beyond the existing CEMS capability.

   20.  At least 60 days prior to all stack testing required in this plan approval (except uncontrolled NOx testing), the permittee shall submit two copies of a test protocol to the Department's Northcentral Region for review and approval. This protocol shall describe the test methods and procedures to be used in the performance of testing, and shall include dimensioned sketches of the exhaust systems showing the locations of all proposed sampling ports. The protocol shall also identify all process parameters, which will be monitored and recorded during testing to verify the throughput rate (for wood fuel handling equipment) and boiler heat input and steam flow during testing, and to verify that all associated air cleaning devices are operating normally during testing.

   At least 14 days prior to stack testing, the permittee shall notify the Department (Northcentral Regional Office and Central Office, Source Testing Section) of the actual dates and times that testing will occur so that Department personnel can arrange to be present during testing. The Department is under no obligation to accept the results of the testing without having been given proper notification.

   Within 60 days following the completion of the stack testing, the permittee shall submit two copies of a test report to the Department's Northcentral Region for review and approval. The test report shall contain the results of the testing, a description of the test methods and procedures actually used, copies of all raw test data with sample calculations and copies of all process data recorded during testing and operating load calculations (material throughput and boiler heat input and steam flow). Since the testing is required for the purpose of demonstrating compliance with emission limitations identified in this plan approval, the results of the testing shall be expressed in units identical to the units of the limitations identified in this plan approval.

   21.  The permittee shall keep records of the amount of CO, NOx, SO2, VOCs, PM and PM10 emitted each month from boiler Nos. 1--3, the line I first stage dryers (combustion only) and the line I second stage dryers (combustion only) and the amount of HCl and mercury emitted each month (based on fuel analysis) from boiler No. 3 and shall verify compliance with the annual emission limitations required in this plan approval. The records shall be maintained for a minimum of 5 years and shall be made available to the Department upon request.

   22.  The permittee shall keep records of the type and amount (including heat input) of wood fuel burned in boiler No. 3 each month and shall accurately demonstrate, by monthly sampling and analysis, that all wood fuel types and mixtures of wood fuels burned would result in less than 0.035 lb/mmBtu of HCl emissions and less than 3.34e-06 lbs/mmBtu of mercury emissions. The records shall be retained for a minimum of 5 years and shall be made available to the Department upon request.

   23.  Under 40 CFR 52.21(r)(6)(iii) and (v), the permittee shall keep records of the annual emissions, in tons per year on a calendar year basis, of PM and PM10 from the dry wood silo, the coated fuel silo, the dry fuel metering bin, the coated fuel silo emergency discharge and the dry wood silo emergency discharge. The records of PM and PM10 emissions shall be kept for 10 years. The permittee shall submit a report to the Department if the emissions, in tons per year, from the above sources cause the boiler modification project to exceed the baseline actual emissions (as documented in the application materials) by a significant amount for the regulated NSR pollutants (PM and/or PM10), and if such emissions differ from the pre-modification projection as documented in the application materials. The report shall be submitted to the Department within 60 days after the end of such year. In addition, all records kept shall be retained for a minimum of 5 years and shall be made available to the Department upon request.

   24.  The permittee shall submit quarterly reports of the monthly amount of CO, NOx, SO2, VOCs, PM and PM10 emitted from boiler Nos. 1--3, the line I first stage dryers (combustion only) and the line I second stage dryers (combustion only) and the monthly amount of HCl and mercury emitted (based on fuel analysis) from boiler No. 3 along with the supporting calculations. The quarterly reports shall verify compliance with the annual emission limitations required in this plan approval. The quarterly reports shall be submitted to the Department within 30 days of the end of each calendar quarter.

   25.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the SNCR reagent injected into the boiler shall be NOxOUT-HP®.

   26.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the SNCR system shall be interlocked with the AFT such that NOxOUT-HP® is not injected if the AFT is less than 1,175° F.

   27.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the NOxOUT-HP® injection rate shall be controlled based on boiler steam load and a NOx emission set-point of 115 ppmdv at 7% oxygen or 100 ppmdv at 7% oxygen (based on the results of the NOx set point plan referenced in this plan approval; the final limit will be incorporated into the operating permit) as specified in the application materials submitted to the Department. The injection rate of NOxOUT-HP® shall not exceed 30 gallons per hour, except as needed during Part II of the NOx set-point plan to achieve a NOx set-point of 100 ppmdv at 7% oxygen. If the stack test results show ammonia slip less than 15.2 ppmdv, at a urea injection rate greater than 30 gallons per hour, the permittee may inject at the higher urea rate (the higher injection rate will be incorporated into the operating permit).

   28.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the coated fuel silo emergency discharge shall be equipped with a blanking plate that prevents any discharge of dry fiber from the silo during normal operation. In addition, the fiber in the silo shall be wetted down prior to activating the emergency discharge.

   29.  Under the BAT provisions in 25 Pa. Code §§ 127.1 and 127.12, the dry wood silo emergency discharge (Source ID 155P of Title V operating permit 08-00003) shall be equipped with a flexible discharge to direct wood fiber to the ground.

   Copies of the application and the Department's review of the application are available for public review between 8 a.m. and 4 p.m. at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review may be made by calling the Department at (570) 327-3693.

   Written comments or requests for a public hearing should be directed to Muhammad Q. Zaman, Chief, Facilities Permitting Section, Department of Environmental Protection, Air Quality Program, Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701, (570) 327-0512.

   41-327-003A: PMF Industries, Inc. (2601 Reach Road, Williamsport, PA 17701) for the modification of a batch vapor degreaser in the City of Williamsport, Lycoming County.

   The batch vapor degreaser uses trichloroethylene, which has been designated as both a VOC and a HAP by the United States Environmental Protection Agency, to clean metal parts. It is equipped with a refrigerated freeboard chiller to help reduce trichloroethylene emissions. The proposed modification is an increase in the allowable trichloroethylene emissions from the batch vapor degreaser from the current limit of 9.99 tons per year to 13.0 tons per year.

   The facility in which the batch vapor degreaser is located is not currently a major (Title V) facility for any air contaminant but will become one for hazardous air pollutants after the proposed modification has occurred. The Department of Environmental Protection (Department) review of the information provided by PMF Industries, Inc. indicates that the modified batch vapor degreaser should comply with all applicable regulatory requirements pertaining to air contamination sources and the emission of air contaminants including the BAT requirement of 25 Pa. Code §§ 127.1 and 127.12 and the requirements of Subpart T of the National Emission Standards for Hazardous Air Pollutants, 40 CFR 63.460--63.470 (Halogenated Solvent Cleaning). Based on this finding, the Department of Environmental Protection proposes to issue plan approval for the proposed modification.

   The following is a summary of the conditions the Department proposes to place in the plan approval to be issued to ensure compliance with all applicable regulatory requirements:

   1.  Conditions contained in Operating Permit 41-327-003 remain in effect unless superseded or amended by a condition contained herein.

   2.  The amount of trichloroethylene used in the batch vapor degreaser shall not exceed 13.0 tons in any 12-consecutive month period. In determining compliance with this limit, any trichloroethylene shipped off-site in liquid form need not be counted as usage provided it is 100% trichloroethylene. Mixtures of trichloroethylene, sludge, and the like, may not be excluded or subtracted unless the trichloroethylene content for each drum or other container of the mixture has been determined through appropriate analysis and then only the trichloroethylene portion may be excluded.

   3.  The permittee shall maintain accurate and comprehensive records of the amount of trichloroethylene added to the batch vapor degreaser each month as well as the amount of 100% trichloroethylene shipped offsite each month. If the permittee excludes or subtracts from the monthly trichloroethylene usage total, any trichloro- ethylene that is contained in a mixture of trichloro- ethylene and sludge or trichloroethylene and any other material which is shipped offsite, records must also be maintained of the amount of trichloroethylene in each such shipment, the date of shipment, the trichloro- ethylene content of each drum or container shipped and a description of the analytical method used to determine the trichloroethylene content. Records maintained under this condition shall be retained onsite for at least 5 years and shall be made available to the Department upon request.

   4.  Within 120 days of being notified by the Department to submit a Title V operating permit application for the facility in which the batch vapor degreaser is located, the permittee shall submit a complete and comprehensive application to the Department.

   Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481, George Monasky, New Source Review Chief, (814) 332-6940.

   24-123E: Onyx Greentree Landfill, LLC (635 Toby Road, Kersey, PA 15846) for installation of an additional enclosed ground flare (6,000 cfm) similar in design to the existing flares in Fox Township, Elk County. This installation will not result in NSR or PSD applicability. This is a Title V facility. The public notice is required for sources required to obtain a Plan Approval at Title V facilities in accordance with 25 Pa. Code § 127.44. This plan approval will, in accordance with 25 Pa. Code § 127.450, be incorporated into the Title V operating permit through an administrative amendment at a later date. The source shall comply with the following conditions, which will satisfy the requirements of 25 Pa. Code § 127.12b (pertaining to plan approval terms and conditions) and will demonstrate Best Available Technology for the source:

   *  The source shall comply with 25 Pa Code §§ 123.1, 123.21, 123.31, and 123.41 for fugitive matter, sulfur compound, odor and visible emissions.

   *  The flare shall be designed for and operated with no visible emissions except for periods not to exceed a total of 5 minutes during any 2-consecutive hours and the emissions during these periods shall not exceed 10% opacity. The opacity of the emissions shall not be equal to or greater than 60% at any time.

   *  The flare shall be designed and operated to either reduce nonmethane organic compounds (NMOC) by 98 weight percent or reduce the outlet NMOC concentration to less than 20 ppmv, dry basis as hexane @3% oxygen. This minimum DRE and outlet concentration is also required by 40 CFR 60.752(b)(2)(iii)(B) of the Federal New Source Performance Standards.

   *  PM emissions from the flare shall not exceed 0.02 grain/dscf.

   *  The flare shall be stack tested for NOx, CO and NMOC.

   *  The flare shall maintain a minimum operating temperature of 1,500° F for at least 0.3 second. The minimum operating temperature of the flare shall be 1,500° F or the operating temperature maintained during the performance test in which compliance with the 98% destruction efficiency or 20 ppmv requirement was demonstrated. The operating temperature of the flare shall be continuously measured and recorded.

   *  The flare shall be designed and operated in accordance with 40 CFR 60.18.

   *  The flare must be an enclosed ground type, which is shrouded with no visible flame shooting from the flare.

   *  The flare shall be equipped with a continuous pilot ignition source using an auxiliary fuel.

   *  The flare shall be operated with a flame present at all times. The flare shall be equipped with an automatic shut-off mechanism designed to immediately stop the flow of gases when a flameout occurs. During restart or start-up, there shall be sufficient flow of auxiliary fuel to the burners so that unburnt landfill gases are not emitted to the atmosphere. The owner or operator shall keep on file records of all periods of operation in which the flame or flare pilot flame is absent. The records shall be made readily available upon Department request.

   *  The permittee shall perform quarterly monitoring to determine there are no landfill gas leaks which result in concentrations of 500 ppmv or more measured as propane (or 1,375 ppmv or more measure as methane) at a distance of 0.5 inch from any exposed equipment. The landfill equipment subject to this requirement shall include the exposed portions of the gas wells, piping or any other connections or fittings along the landfill gas transfer paths of a landfill gas collection and disposal system. A log shall be kept at the facility indicating any leak that exceeds the above concentration and the corrective action taken for a period of 5 years and made readily available to Department personnel upon request.

   *  A detailed record describing the time, location, type and amount of roadway surface treatment shall be maintained at the landfill site for at least 5 years.

   *  Petroleum contaminated soils may be used as daily landfill cover provided the VOC emissions from the contaminated soils does not exceed 2.7 tpy based on a consecutive 12-month period. The facility shall keep records of the petroleum-contaminated soil received at the landfill.

   *  The collection system shall be designed to minimize offsite migration of the subsurface gas. The gas collection system shall be designed: 1) to collect gas from the maximum possible area of the landfill; and 2) to accommodate the maximum gas generation rate for the landfill. Should the landfill gas flow rate from the disposal area exceed the maximum design capacity of the control devices, the company shall submit a plan approval application for the installation of an additional control device deemed acceptable by the Department.

   *  The landfill gas shall be controlled and monitored in accordance with 25 Pa Code § 273.292.

   *  25 Pa Code § 273.217 requires landfill operators to implement fugitive air contaminant control measures and otherwise prevent and control air pollution in accordance with the Air Pollution Control Act (35 P. S. §§ 4001--4014), 25 Pa. Code Part I, Subpart C, Article III (relating to air resources) and 25 Pa Code § 273.218 (relating to nuisance minimization and control).

   *  Fugitive Emission Control Criteria: This criterion specifies the reasonable actions that are necessary for the prevention of fugitive dust emissions from the operation of landfills in accordance with these requirements.

   *  The facility shall comply with New Source Performance Standards (NSPS) 40 CFR Part 60 Subpart WWW and shall comply with all applicable requirements of this subpart. This includes, but is not limited to, the following:

   *  In accordance with 40 CFR 60.756(b)(2), the facility shall either:

   *  Install, calibrate and maintain a gas flow rate measuring device that shall record the flow to the control device at least every 15 minutes; or

   *  Secure the bypass line valve in the closed position with a car-seal or a lock-and-key type of configuration. A visual inspection of the seal or closure mechanism shall be performed at least once every month to ensure that the valve is maintained in the closed position and that the gas flow is not diverted through the bypass line.

   *  In accordance with 40 CFR 60.755(b), each well shall be installed no later than 60-days after the date on which the initial solid waste has been in place for a period of: 5 years or more if active; or 2 years or more if closed or at final grade.

   *  In accordance with 40 CFR 60.753(c) and 60.756(a), each interior wellhead in the collection system shall be operated with a landfill gas temperature less than 55° C and with either a nitrogen level less than 20% or an oxygen level less than 5%. The above parameters shall be monitored monthly and records shall be kept on file for a period of 5 years and made readily available to Department personnel upon request. Should the temperature or nitrogen and/or oxygen level be exceeded during the monitoring of these wellheads, the permittee shall take the necessary steps, in accordance with 40 CFR 60.755(a)(5), to bring the affected wellheads into compliance. The monitoring procedures shall comply with the provisions of 40 CFR 60.756(a).

   *  In accordance with 40 CFR 60.753(d), 60.755(c) and 60.756(f), the collection system shall be operated so that the methane concentration is less than 500 parts per million above background at the surface of the landfill. The owner or operator shall monitor surface concentrations of methane along the entire perimeter of the collection area and along a serpentine pattern spaced 30 meters apart (or a site-specific established spacing) for each collection area on a quarterly basis. Methane concentration shall be less than 500 parts per million above background at the surface of the landfill using an organic vapor analyzer, flame ionization detector or other portable monitor meeting Section 3, 40 CFR Part 60, Appendix A, Method 21. Records shall be kept on file for a period of five years and made readily available to Department personnel upon request.