Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Bulletin website includes the following: Rulemakings by State agencies; Proposed Rulemakings by State agencies; State agency notices; the Governor’s Proclamations and Executive Orders; Actions by the General Assembly; and Statewide and local court rules.

PA Bulletin, Doc. No. 06-1972a

[36 Pa.B. 6110]
[Saturday, October 7, 2006]

[Continued from previous Web Page]

   PA0031895, Sewage, Nemacolin Country Club, P. O. Box 134, Beallsville PA 15313-0134. This application is for renewal of an NPDES permit to discharge treated sewage from Nemacolin Country Club STP in Centerville Borough, Washington County.

   The following effluent limitations are proposed for discharge to the receiving waters, known as Drainage Swale to North Branch Fishpot Run, which are classified as a WWF with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the PA American Water Co., Brownsville Plant on the Monongahela River.

   Outfall 001:  existing discharge, design flow of 0.006 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 10 20
Suspended Solids 25 50
Ammonia Nitrogen
   (5-1 to 10-31) 3.0 6.0
   (11-1 to 4-30) 9.0 18.0
Fecal Coliform
   (5-1 to 9-30) 200/100 ml as a geometric mean
   (10-1 to 4-30) 2,000/100 ml as a geometric mean
Total Residual Chlorine 1.4 3.3
Dissolved Oxygen not less than 5.0 mg/l
pH not less than 6.0 nor greater than 9.0

   The EPA waiver is in effect.

   PA0204366, Sewage, Clear Channel Entertainment, 125 West Station Square Drive, Pittsburgh PA 15215-1122. This application is for renewal of an NPDES permit to discharge treated sewage from Post Gazette Pavilion in Hanover Township, Washington County.

   The following effluent limitations are proposed for discharge to the receiving waters, known as UNT to Harmon Creek which are classified as a WWF with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the City of Wheeling.

   Outfall 001:  existing discharge, design flow of 0.018 mgd from May 1 to Octber 31 and 0.03 mgd from November 1 to April 30.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 25 50
Suspended Solids 30 60
Ammonia Nitrogen
   (5-1 to 10-31) 3.0 6.0
   (11-1 to 4-30) 8.5 17.0
Fecal Coliform
   (5-1 to 9-30) 200/100 ml as a geometric mean
   (10-1 to 4-30) 2,000/100 ml as a geometric mean
Total Residual Chlorine
   (5-1 to 10-31) 0.35 0.9
   (11-1 to 4-30) 0.45 1.0
Dissolved Oxygen not less than 4 mg/l
pH not less than 6.0 nor greater than 9.0

   The EPA waiver is in effect.

   PA0217042, Sewage, Game Commission, 4280 Route 711, Bolivar, PA 15923-2420. This application is for renewal of an NPDES permit to discharge treated sewage from the Game Commission Sewage Treatment Plant in Fairfield Township, Westmoreland County.

   The following effluent limitations are proposed for discharge to the receiving waters, known as UNT of Loves Hollow which are classified as a TSF with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the: Saltsburg Municipal Water Works on the Conemaugh River.

   Outfall 001:  existing discharge, design flow of 0.004 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 10 20
Suspended Solids 10 20
Ammonia Nitrogen
   (5-1 to 10-31) 8.0 16.0
   (11-1 to 4-30) 24.0 48.0
Fecal Coliform
   (5-1 to 9-30) 200/100 ml as a geometric mean
   (10-1 to 4-30) 2,000/100 ml as a geometric mean
Total Residual Chlorine 1.4 3.3
Dissolved Oxygen not less than 3 mg/l
pH not less than 6.0 nor greater than 9.0

   The EPA waiver is in effect.

   PA0253219, Sewage, East Franklin Township, R. D. 3, Box 211A, Kittanning, PA 16201. This application is for issuance of an NPDES permit to discharge treated sewage from Cowansville Sewage Treatment Plant in East Franklin Township, Armstrong County.

   The following effluent limitations are proposed for discharge to the receiving waters, known as Glade Run which are classified as a TSF with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the Buffalo Township Municipal Authority Freeport located on the Allegheny River.

   Outfall 001:  new discharge, design flow of 0.029 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 25 50
Suspended Solids 30 60
Ammonia Nitrogen
   (5-1 to 10-31) 5.0 10.0
   (11-1 to 4-30) 15.0 30.0
Fecal Coliform
   (5-1 to 9-30) 200/100 ml as a geometric mean
   (10-1 to 4-30) 2,000/100 ml as a geometric mean
Total Residual Chlorine 0.4 0.9
Dissolved Oxygen not less than 3 mg/l
pH not less than 6.0 nor greater than 9.0

   The EPA waiver is in effect.

   PA0253383, Sewage, Anna K. Wright, 376 North Tower Road, Fombell, PA 16123. This application is for renewal of an NPDES permit to discharge treated sewage from Wright Sewage Treatment Plant in Franklin Township, Beaver County.

   The following effluent limitations are proposed for discharge to the receiving waters known as UNT of Hazen Run, which are classified as a WWF with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the Beaver Falls Municipal Authority on the Beaver River.

   Outfall 001:  existing discharge, design flow of 0.0004 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 25 50
Suspended Solids 30 60
Fecal Coliform
   (5-1 to 9-30) 200/100 ml as a geometric mean
   (10-1 to 4-30) 2,000/100 ml as a geometric mean
Total Residual Chlorine Monitor and Report
pH not less than 6.0 nor greater than 9.0

   The EPA waiver is in effect.


   Northwest Region:  Water Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

   PA0005061-Amendment No. 1, Industrial Waste. Orion Power Midwest LP, New Castle Plant, 121 Champion Way, Canonsburg, PA 15317-5817. This proposed facility is located in Taylor Township, Lawrence County.

   Description of Proposed Activity: existing discharge of noncontact cooling water, treated industrial waste, miscellaneous wastewaters and stormwater runoff.

   For the purpose of evaluating effluent requirements for TDS, NO2-NO3, fluoride, phenolics, sulfate and chloride, the existing/proposed downstream potable water supply (stream and Public Water Supplier) considered during the evaluation is Beaver Falls Municipal Authority--Eastvale plant on the Beaver River located approximately 16 miles below point of discharge.

   The receiving stream, Beaver River (Outfalls 001--006, 009, 010 and 101), and McKee Run (Outfalls 007, 008 and 011--013), is in Watershed 20-A and classified for WWF, aquatic life, water supply and recreation.

   The proposed effluent limits for Outfall 004 based on a design flow of 1.0 mgd.

Concentrations
AverageMaximumInstantaneous
Parameter Monthly (mg/l) Daily (mg/l) Maximum (mg/l)
Flow XX XX
Total Suspended Solids 30 100
Oil and Gas 15 20 30
Iron 3.0 7.0 8.75
pH 6.0 to 9.0 standard units at all times

   XX--Monitor and report.

   The EPA waiver is not in effect.

   PA0026301, Sewage. Erie Sewage Authority and the City of Erie, 68 Port Access Road, Erie, PA 16507-2202. This proposed facility is located in City of Erie, Erie County.

   Description of Proposed Activity: Renewal of an existing discharge of treated sewage.

   For the purpose of evaluating effluent requirements for TDS, NO2-NO3, fluoride, phenolics, sulfate and chloride, the existing/proposed downstream potable water supply, considered during the evaluation is the Pennsylvania/Canadian international boundary located in Lake Erie.

   The receiving stream, the Lake Erie (Outer Erie Harbor and Presque Isle Bay), Mill Creek and Garrison Run is in Watershed 15 and classified for WWF, migratory fishes (for Mill Creek), aquatic life, water supply and recreation.

   The proposed effluent limits for Outfall 001 and 001A are based on a design flow of 68.6 mgd.

Loadings Concentrations
AverageAverageAverageAverageInstantaneous
Parameters Monthly (lb/day) Weekly (lb/day) Monthly (mg/l) Weekly (mg/l) Maximum (mg/l)
Flow XX
Fecal Coliform
   (5-1 to 9-30) 200/100 ml as a geometric average
   (10-1 to 4-30) 2,000/100 ml as a geometric average
Total Residual Chlorine 0.5 1.6

   The proposed effluent limits for Suboutfall 101 are based on a design flow of 68.6 mgd.

Loadings Concentrations
AverageAverageAverageAverageInstantaneous
Parameters Monthly (lb/day) Weekly (lb/day) Monthly (mg/l) Weekly (mg/l) Maximum (mg/l)
Flow (mgd) XX XX
CBOD5 14,303 22,885 25 40 50
Total Suspended Solids 17,164 25,746 30 45 60
Phosphorus as ''P'' 572 1
pH 6.0 to 9.0 Standard Units at all times

   The proposed effluent limits for Outfall 002 are based on a design flow of N/A mgd.

Loadings Concentrations
AverageAverageAverageAverageInstantaneous
Parameters Monthly (lb/day) Weekly (lb/day) Monthly (mg/l) Weekly (mg/l) Maximum (mg/l)
Flow (mgd)* XX
Total Residual Chlorine* 1.6
Fecal Coliform*
   (5-1 to 9-30) 200/100 ml as a geometric average
   (10-1 to 4-30) 2,000/100 ml as a geometric average

   The proposed effluent limits for Suboutfall 201 are based on a design flow of N/A mgd.

Loadings Concentrations
AverageAverageAverageAverageInstantaneous
Parameters Monthly (lb/day) Weekly (lb/day) Monthly (mg/l) Weekly (mg/l) Maximum (mg/l)
Flow (mgd)* XX

   *--Monitor when discharging

   XX--Monitor and report on monthly DMRs.

   Special Conditions:

   1.  Total Residual Chlorine Minimization.
2.  Federal Pretreatment Program.
3.  Stormwater Outfalls.
4.  CSO Related Bypass.
5.  Combined Sewer Overflows.
6.  Whole Effluent Toxicity testing for the renewal.

   The EPA waiver is not in effect.


III.  WQM Industrial Waste and Sewerage Applications Under the Clean Streams Law (35 P. S. §§ 691.1--691.1001)

   Southcentral Region:  Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110, (717) 705-4707.

   WQM Permit No. 3606202, CAFO, Wanner's Pride-N-Joy Farm, 5800 Wanner Road, Narvon, PA 17555. This proposed facility is located in Salisbury Township, Lancaster County.

   Description of Proposed Action/Activity: Phase 1 of this project involves the construction of a methane digester system which will include a circular concrete digester tank and a rectangular concrete influent/effluent tank. Phase 2 of this project involves the construction of a manure solids separator and solids stacking area.

   WQM Permit No. 6780405, Amendment 06-1, Sewerage, Manchester Township Municipal Authority, 3200 Farm Trail Road, York, PA 17402. This proposed facility is located in Manchester Township, York County.

   Description of Proposed Action/Activity: Expansion of the Farmbrook Industrial Park pump station.

   Southwest Region:  Water Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

   WQM Permit No. 0406401, Sewerage, Borough of Ambridge Municipal Authority, 600 Eleventh Street, Ambridge, PA 15003. This proposed facility is located in Ambridge Borough, Beaver County.

   Description of Proposed Action/Activity: Application for the construction and operation of a pump station improvement and sewer replacement.

   The Pennsylvania Infrastructure Investment Authority which administers Pennsylvania's State Revolving Fund has been identified as a possible funding source. The Department of Environmental Protection's review of the sewage facilities plan revision has not identified any significant environmental impacts resulting from this proposal.

   WQM Permit No. 6306407, Sewerage, Hanover Township Sewer Authority, 116 Steubenville Pike, Paris, PA 15021. This proposed facility is located in Hanover Township, Washington County.

   Description of Proposed Action/Activity: Application for construction and operation of sanitary sewers.

   The Pennsylvania Infrastructure Investment Authority which administers Pennsylvania's State Revolving Fund has been identified as a possible funding source. The Department of Environmental Protection's review of the sewage facilities plan revision has not identified any significant environmental impacts resulting from this proposal.


IV.  NPDES Applications for Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)


V.  Applications for NPDES Waiver Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)


VI.  NPDES Individual Permit Applications for Discharges of Stormwater Associated with Construction Activities

   Southeast Region:  Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI011506072 Phillips Road Associates
202 Phillips Road
Exton, PA 19341
Chester Uwchlan Township Pine Creek
HQ-TSF
PAI011506073 Julie I. Blank
471 Fairmount Drive
Chester Springs, PA 19425
Chester East Nantmeal Township Beaver Run
EV
PAI011506074 James Spotts
1310 Harmonyville Road
Pottstown, PA 19465
Chester South Coventry Township Pigeon Creek
HQ-TSF-MF
PAI011506075 Southdown Homes
55 Country Club Drive
Suite 200
Downingtown, PA 19335
Chester East Brandywine Township East Branch Brandywine Creek
HQ-TSF

   Northeast Region:  Watershed Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.

   Lehigh County Conservation District:  Lehigh Ag. Center, Suite 102, 4184 Dorney Park Road, Allentown, PA 18104, (610) 391-9583.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI023906027 Rudy Amelio
Devonshire Properties, LLC
1348 Hamilton St.
Allentown, PA 18102
Lehigh City of Allentown Little Lehigh Creek
HQ-CWF

   Northampton County Conservation District:  Greystone Bldg., Gracedale Complex, Nazareth, PA 18064-9211, (610) 746-1971.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI024806023 Wind-Drift Real Estate Associates
Attn: Lewis Ronca
179 Mikron Road
Bethlehem, PA 18017
Northampton City of Bethlehem Nancy Run (SR 3007 Bridge to Mouth)
HQ-CWF, MF

   Southcentral Region:  Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI032106007 Members 1st FCU
5000 Louise Drive
Mechanicsburg, PA 17055
Cumberland Hampden Township UNT Conodoguinet
WWF
PAI030506005 Nate Kissell
New Enterprise Stone and
Lime Co., Inc.
P. O. Box 77
New Enterprise, PA 16664
Bedford Bedford Township Shober's Run
HQ-CWF
Raystown Branch Juniata River/TSF

   Northwest Region:  Watershed Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI064206003 Dr. Steven Herrmann and J.A. Luciano & Sons Builders
One Ichabod Lane
Bradford, PA 16701
McKean Bradford Township Minard Run
EV

VII.  List of NOIs for NPDES and/or Other General Permit Types

PAG-12 Concentrated Animal Feeding Operations (CAFOs)
PAG-13 Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)

PUBLIC WATER SUPPLY (PWS) PERMIT

   Under the Pennsylvania Safe Drinking Water Act (35 P. S. §§ 721.1--721.17), the following parties have applied for a PWS permit to construct or substantially modify a public water system.

   Persons wishing to comment on a permit application are invited to submit a statement to the office listed before the application within 30 days of this public notice. Comments received within the 30-day comment period will be considered in the formulation of the final determinations regarding the application. Comments should include the name, address and telephone number of the writer and a concise statement to inform the Department of Environmental Protection (Department) of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.

   Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.

   The permit application and any related documents are on file at the office listed before the application and are available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.

   Persons with a disability who require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

SAFE DRINKING WATER


Applications Received under the Pennsylvania Safe Drinking Water Act

   Northeast Region:  Water Supply Management Program, 2 Public Square, Wilkes-Barre, PA 18711-0790.

   Application No. 5206504, Public Water Supply.

Applicant S & S Construction Group
Dingman Township
Pike County
Responsible Official Xui Quan Shi, President
P. O. Box 1126
Montague, NJ
(973) 293-3546
Type of Facility Community Water System
Consulting Engineer Brian D. Swanson, P. E.
Swanson Engineering, PC
435 Green Ridge Street
Scranton, PA 18509
(570) 558-2727
Application Received Date May 13, 2005
Description of Action Application for construction of a new supply well, along with two 3,000 gallon finished water storage tanks, chemical treatment facilities and distribution to supply expansion of the existing Maple Park Garden residential townhouse development.

   Southcentral Region:  Water Supply Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.

   Permit No. 2806501, Public Water Supply.

Applicant Waynesboro Borough Authority
Municipality Waynesboro Borough
County Franklin
Responsible Official S. Leiter Pryor
Director of Borough Utilities
57 East Main Street
Waynesboro, PA 17268
Type of Facility Public Water Supply
Consulting Engineer James C. Elliot, P. E.
Gannett Fleming, Inc.
P. O. Box 67100
Harrisburg, PA 17106-7100
Application Received: 3/15/2006
Description of Action The addition of Well No. 2 to augment the existing sources of supply and treatment. Treatment will consists of nanofiltration and disinfection.

   Permit No. 3606510, Public Water Supply.

Applicant Salisbury Township Fire Company No. 1
Municipality Salisbury Township
County Lancaster
Responsible Official John M. Beyer, President
111 White Horse Road
Gap, PA 17527
Type of Facility Public Water Supply
Consulting Engineer Charles A Kehew II, P. E.
James R. Holley & Assoc., Inc.
18 South George St.
York, PA 17401
Application Received: 6/26/2006
Description of Action Installation of a anion exchange nitrate treatment system to remove elevated levels of nitrate.

   Permit No. 0706502, Public Water Supply.

Applicant Henrietta Mutual Water Association
Municipality North Woodbury Township
County Blair
Responsible Official Edward Barszczowski, President
R. D. 1, Box 603
Martinsburg, PA 16662
Type of Facility Public Water Supply
Consulting Engineer Thomas M. Levine, P. E.
Richard H. Bulger, Jr. & Associates, Inc.
P. O. Box 331
Martinsburg, PA 16662
Application Received: 8/1/2006
Description of Action The addition of Well No. 1 to replace the existing spring source and the addition of a polyphosphate compound to sequester elevated levels of manganese in the new source water.

   Permit No. 2806505, Public Water Supply.

Applicant D-111 Group, LLC
Municipality Hamilton Township
County Franklin
Responsible Official Eugene R. Strite Member/President
826 Tallow Hill Road
Chambersburg, PA 17055
Type of Facility Public Water Supply
Consulting Engineer Lance S. Kegerreis, P. E.
Dennis E. Black Engineering Inc.
2400 Philadelphia Avenue
Chambersburg, PA 17201
Application Received: 8/11/2006
Description of Action This is for a new PWS that will serve the Whiskey Run System. The system will consists of three wells, treatment to consists of disfection and greensand filtration for iron and manganese removal, finished water storage and distribution.

   Northcentral Region:  Water Supply Management Program Manager, 208 West Third Street, Williamsport, PA 17701.

   Permit No. 4106502--Construction Public Water Supply.

Applicant Lycoming County Water and Sewer Authority
Township or Borough Muncy and Fairfield Townships
County Lycoming
Responsible Official Christine Maggi
Executive Director
Lycoming County Water and Sewer Authority
216 Old Cement Road
Montoursville, PA 17754
Type of Facility Public Water Supply--Construction
Consulting Engineer Brian L. Book, P. E.
Herbert, Rowland & Grubic, Inc.
474 Windmere Drive
State College, PA 16801
Application Received Date September 20, 2006
Description of Action Construction of approximately 20,000 linear feet of waterline, water supply well, treatment facilities and a 300,000 gallon finished water storage tank.

   Southwest Region:  Water Supply Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

   Permit No. 0406504, Public Water Supply.

Applicant Conway Borough
1208 Third Avenue
Conway, PA 15027
Township or Borough Conway Borough
Responsible Official Greg Ritorto, Council President
Conway Borough
1208 Third Avenue
Conway, PA 15027
Type of Facility Water treatment plant
Consulting Engineer NIRA Consulting Engineers, Inc.
950 Fifth Avenue
Coraopolis PA 15108
Application Received Date September 5, 2006
Description of Action New water storage facility and related appurtenances, construction of a new pumping station, distribution systems upgrades and replacements and construction of an emergency interconnection with Ambridge.

   Permit No. 0206511, Public Water Supply.

Applicant Coraopolis Water & Sewer Authority
1012 Fifth Avenue
Coraopolis, PA 15108
Township or Borough Coraopolis
Responsible Official Thomas Cellante, Jr.
Coraopolis Water & Sewer Authority
1012 Fifth Avenue
Coraopolis, PA 15108
Type of Facility Water treatment plant
Consulting Engineer Lennon, Smith, Souleret Engineering, Inc.
846 Fourth Avenue
Coraopolis, PA 15108
Application Received Date September 25, 2006
Description of Action Demolish Fleming Street and cemetery water storage tanks and construct a 0.7 million gallon steel reservoir at Fleming Street and a 0.75 million gallon steel elevated storage tank at cemetery. Installation of pressure reducing stations, cleaning and painting of the School Street water storage tank. Replacement of the existing Fleming Street booster station (pumping and rechlorination).

LAND RECYCLING AND ENVIRONMENTAL REMEDIATION

UNDER ACT 2, 1995

PREAMBLE 1


Acknowledgment of Notices of Intent to Remediate Submitted under the Land Recycling and Environmental Remediation Standards Act (35 P. S. §§ 6026.101--6026.908).

   Sections 302--305 of the Land Recycling and Environmental Remediation Standards Act (act) require the Department of Environmental Protection (Department) to publish in the Pennsylvania Bulletin an acknowledgment noting receipt of Notices of Intent to Remediate. An acknowledgment of the receipt of a Notice of Intent to Remediate is used to identify a site where a person proposes to, or has been required to, respond to a release of a regulated substance at a site. Persons intending to use the Background Standard, Statewide Health Standard, the Site-Specific Standard or who intend to remediate a site as a special industrial area must file a Notice of Intent to Remediate with the Department. A Notice of Intent to Remediate filed with the Department provides a brief description of the location of the site, a list of known or suspected contaminants at the site, the proposed remediation measures for the site and a description of the intended future use of the site. A person who demonstrates attainment of one, a combination of the cleanup standards or who receives approval of a special industrial area remediation identified under the act will be relieved of further liability for the remediation of the site for any contamination identified in reports submitted to and approved by the Department. Furthermore, the person shall not be subject to citizen suits or other contribution actions brought by responsible persons not participating in the remediation.

   Under sections 304(n)(1)(ii) and 305(c)(2) of the act, there is a 30-day public and municipal comment period for sites proposed for remediation using a Site-Specific Standard, in whole or in part, and for sites remediated as a special industrial area. This period begins when a summary of the Notice of Intent to Remediate is published in a newspaper of general circulation in the area of the site. For the sites identified, proposed for remediation to a Site-Specific Standard or as a special industrial area, the municipality within which the site is located may request to be involved in the development of the remediation and reuse plans for the site if the request is made within 30 days of the date specified. During this comment period, the municipality may request that the person identified as the remediator of the site develop and implement a public involvement plan. Requests to be involved and comments should be directed to the remediator of the site.

   For further information concerning the content of a Notice of Intent to Remediate, contact the environmental cleanup program manager in the Department regional office before which the notice appears. If information concerning this acknowledgment is required in an alternative form, contact the community relations coordinator at the appropriate regional office. TDD users may telephone the Department through the AT&T Relay Service at (800) 654-5984.

   The Department has received the following Notices of Intent to Remediate:

   Southeast Region:  Environmental Cleanup Program Manager, 2 East Main Street, Norristown, PA 19401.

   Apex on York, City of Philadelphia, Philadelphia County. Robert E. Edwards, RETTEW Associates, Inc, 3020 Columbia Ave., Lancaster, PA 17603 on behalf of Greg Pellathy, Pell Parnters, 116 Greenwood Ave., Wyncote, PA 19095 has submitted a Notice of Intent to Remediate. Soil at the site has been impacted by releases of SVOC's and metals. The intended future use of the property is student and housing and parking.

   Storage Specialists, LLC, City of Philadelphia, Philadelphia County. Sony Y. Ward, P. G., ENSR Corp., 2005 Cabot Blvd., West, Suite 100, Langhorne, PA 19047 on behalf of Carl Grigorian, Ph.D., P. E., Storage Specialists, LLC, 111 N. Jackson Street, Suite 200, Glendale, CA 91206 has submitted a Notice of Intent to Remediate. Soil at the site has been impacted by release of lead. The future use of the property is for nonresidential commercial use as a storage facility.

   Willow Grove Home Depot, Upper Moreland Township, Montgomery County. Justin Lauterbach, RT Env., Services, Purleand Complex, Suite 306, 510 Heron Drive, P. O. Box 521, Bridgeport, NJ 08014 on behalf of Charles Gallub, Develcom, 204 Harding Road, P. O. Box 217, Bellmawr, NJ 08031 has submitted a Notice of Intent to Remediate. Soil at the site has been impacted by release of arsenic and other organics. The proposed future use of the subject property is commercial.

   Northcentral Region:  Environmental Cleanup Program Manager, 208 West Third Street, Williamsport, PA 17701.

   Former B & B Equipment Site, Clinton Township, Lycoming County. Molesevich Environmental, LLC, P. O. Box 654, Lewisburg, PA 17837 on behalf of Tom Shaheen, Shaheen Auto Sales, 5463 US 15, Montgomery, PA 17752 has submitted a Notice of Intent to Remediate soil and groundwater contaminated with gasoline and diesel fuel. The applicant proposes to remediate the site to meet the Site-Specific Standard. The intended future use of the property will be commercial.

   SEDA-Cog Joint Rail Authority Newberry Yard-South Site, City of Williamsport, Lycoming County. Marshall Miller & Assoc., 3913 Hartzdale Drive, Suite 1306, Camp Hill, PA 17011 on behalf of SEDA-COG Joint Rail Authority, 201 Furnace Road, Lewisburg, PA 17837 has submitted a Notice of Intent to Remediate groundwater contaminated with a separate phase liquid. The applicant proposes to remediate the site to meet the Site-Specific Standard. The planned use and future development of the site is strictly for commercial/industrial purposes.

INFECTIOUS AND CHEMOTHERAPEUTIC WASTE TRANSPORTER LICENSES


Applications received or withdrawn under the Solid Waste Management Act (35 P. S. §§ 6018.101--6018.1003) and act June 28, 1988 (P. L. 525, No. 93) and regulations to transport infectious and chemotherapeutic waste.

   Central Office:  Bureau of Waste Management, Division of Hazardous Waste Management, P. O. Box 8471, Harrisburg, PA 17105-8471.

   Renewal Applications Received

   Cole Care, Inc., 1001 East Second Street, Coudersport, PA 16915, License No. PA-HC 0178. Received on 8/28/06.

   Veolia ES Technical Solutions, LLC, 1 Eden Lane, Flanders, NJ 07836, License No. PA-HC 0221. Received on 8/30/06.

   The Pennsylvania State University, 6 Eisenhower Parking Deck, University Park, PA 16802, License No. PA-HC 0153. Received on 9/6/06.

AIR QUALITY

PLAN APPROVAL AND OPERATING PERMIT APPLICATIONS

NEW SOURCES AND MODIFICATIONS

   The Department of Environmental Protection (Department) has developed an ''integrated'' plan approval, State operating permit and Title V operating permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the public. This approach allows the owner or operator of a facility to complete and submit all the permitting documents relevant to its application one time, affords an opportunity for public input and provides for sequential issuance of the necessary permits.

   The Department has received applications for plan approvals and/or operating permits from the following facilities.

   Copies of the applications, subsequently prepared draft permits, review summaries and other support materials are available for review in the regional office identified in this notice. Persons interested in reviewing the application files should contact the appropriate regional office to schedule an appointment.

   Persons wishing to receive a copy of a proposed plan approval or operating permit must indicate their interest to the Department regional office within 30 days of the date of this notice and must file protests or comments on a proposed plan approval or operating permit within 30 days of the Department providing a copy of the proposed document to that person or within 30 days of its publication in the Pennsylvania Bulletin, whichever comes first. Interested persons may also request that a hearing be held concerning the proposed plan approval and operating permit. Comments or protests filed with the Department regional offices must include a concise statement of the objections to the issuance of the Plan approval or operating permit and relevant facts which serve as the basis for the objections. If the Department schedules a hearing, a notice will be published in the Pennsylvania Bulletin at least 30 days prior the date of the hearing.

   Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office identified before the application. TDD users should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

   Final plan approvals and operating permits will contain terms and conditions to ensure that the source is constructed and operating in compliance with applicable requirements in 25 Pa. Code Chapters 121--143, the Federal Clean Air Act (act) and regulations adopted under the act.

PLAN APPROVALS


Plan Approval Applications Received under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter B that may have special public interest. These applications are in review and no decision on disposition has been reached.

   Southeast Region:  Air Quality Program, 2 East Main Street, Norristown, PA 19401, Thomas McGinley, New Source Review Chief, (484) 250-5920.

   15-0010C: ISG Plate, LLC (139 Modena Road, Coatesville, PA 19320) for installation of a replacement dust collector on a manual cutting operation, identified as the ACA Powder Cutting and Baghouse, at their facility in the City of Coatesville, Chester County. This facility is a Title V facility. The ACA powder cutting and baghouse is identified in the facility's Title V Operating Permit as Source ID 182. The existing dust collector is old and needs to be replaced. The new dust collector is expected to reduce PM emissions to less than 0.01 grain per dry standard cubic feet, which will be equivalent to 0.71 lb/hr. The ACA powder cutting and baghouse will be restricted to these emission rates, as well as an annual emission rate of 3.11 tons/year. The ACA Powder Cutting operation will also result in emissions of chromium, lead, manganese, and nickel, totaling 0.181 ton/year. The Plan Approval will contain monitoring and recordkeeping requirements designed to keep Source ID 182 operating within the allowable emissions and all applicable air quality requirements.

   46-0005AC: Merck and Company, Inc. (P. O. Box 4, WP20-208, 770 Sumneytown Pike, West Point, PA, 19486-0004) for installation of a new biological manufacturing building 12A, this plan approval will also incorporate previously approved construction of a biological manufacturing 12 (buildings 12 and 12A) at the Merck pharmaceutical manufacturing and research facility in Upper Gwynedd Township, Montgomery County. The facility currently has a Title V permit No. TVOP-46-00005. The Plan Approval will subsequently be incorporated into the Title V Operating Permit through an administrative amendment in accordance with 25 Pa. Code § 127.450. The air contaminant emitting sources of buildings 12 and 12A under this approval will consist of 4 shell freezers and a natural gas fueled emergency generator. Based on the information provided by the applicant and Department of Environmental Protection's (Department) own analysis, the four shell freezers will emit a total of 7.2 tons per year of VOCs and 0.36 ton per year of HAPs. Based on the information provided by the applicant and Department's own analysis, the emergency generator will emit 0.19 ton per year of VOCs, 0.47 ton per year of NOx, 0.44 ton per year of CM, 0.01 ton per year of SOx and 0.01 ton per year of PM10. The Plan Approval and Operating Permit will contain requirements to keep the facility operating within all applicable air quality requirements. Further details on the conditions and reasons for their inclusion are available upon request.

   Northeast Region:  Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711-0790, Mark Wejkszner, New Source Review Chief, (570) 826-2531.

   58-303-006: New Milford Materials, LLC (P. O. Box 324A-1, Montrose, PA, 18801) for construction of a batch asphalt plant at their existing B. S. Quarries New Milford Saw Shop and Quarry in New Milford Township, Susquehanna County that will utilize recycled asphalt pavement (RAP) and will be fired on No. 2 fuel oil and waste derived liquid fuel (WDLF). This facility is not a Title V facility. The batch asphalt plant will incorporate no more than 22.0% RAP into the 300 ton per hour facility while any WDLF used will meet all regulatory specifications. The company has elected to take a voluntary production restriction of 400,000 tons of asphalt per year. Emissions from the plant will not exceed 24.0 tpy of NOx, 80.0 tpy of CO, 17.6 tpy of SOx, 1.6 tpy of VOC and 8.4 tpy of PM. The asphalt plant is subject to Subpart I of the Federal Standards of Performance for New Stationary Sources for Hot Mix Asphalt Facilities, 40 CFR 60.90--60.93. The plan approval will include all appropriate testing, monitoring, recordkeeping and reporting requirements designed to keep the batch asphalt plant operating within all applicable air quality requirements.

   Southcentral Region:  Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, Ronald Davis, New Source Review Chief, (717) 705-4702.

   05-05022B: Bedford Reinforced Plastics, Inc. (264 Reynoldsdale Road, Bedford, PA 15522-7401) for installation of two new fiberglass reinforced plastic pultrusion production lines at their facility in East Saint Clair Township, Bedford County. Operation of these pultrusion lines will increase potential HAPs by 6.48 tons per year. The plan approval and subsequent Title V operating permit amendment will include emission restrictions, work practice standards, monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. This project is subject to 40 CFR Part 63, Subpart WWW--National Emission Standards for Hazardous Air Pollutants. Reinforced Plastic Composites Production.

   Northwest Region:  Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481, George Monasky, New Source Review Chief, (814) 332-6940.

   24-161A: Greentree Landfill Gas Co., LLC (Tower Road, Brockway, PA 15824) for construction of two natural gas compressors for boosting natural gas production into the custody transfer point in Horton Township, Elk County. This is a State-only facility. The public notice is required for sources required to obtain a Plan Approval in accordance with 25 Pa. Code § 127.44. This plan approval will, in accordance with 25 Pa. Code § 127.450, be incorporated into the State-only operating permit through an administrative amendment at a later date. The source shall comply with the following conditions, which will satisfy the requirements of 25 Pa. Code § 127.12b (pertaining to plan approval terms and conditions) and will demonstrate Best Available Technology for the source:

*  These internal combustion engines shall be equipped and operated with control devices that reduce emissions to levels equal to or less than:

   *  NOx at rated brake horsepower and operating at rated speed--2.0 grams per brake horsepower-hour (gms/bhp-hr) for gas fired units;

   *  VOC at rated brake horsepower and operating at rated speed--0.4 gms/bhp-hr.;

   *  CO at rated brake horsepower and operating at rated speed--2.0 gms/bhp-hr.; and

   *  At operating conditions less than rated capacity, internal combustion engines shall, on a pounds per hour basis, emit no more than they emit at rated brake horsepower and rated speed.

   *  Visible emissions in excess of the following limitations:

      *  Equal to or greater than 10% for a period or periods aggregating more than 3 minutes in any 1 hour.

      *  Equal to or greater than 30% at any time.

   *  The emission limitations shall apply at all times except during periods of start-up and shut-down, provided, however, that the duration of start-up and shut-down do not exceed 1 hour per occurrence.

   *  This source is subject to 25 Pa. Code §§ 123.1, 123.31 and 123.41 for fugitive, odor and visible emissions, respectively.

   *  No person may permit the emission into the outdoor atmosphere of PM in a manner that the concentration of PM in the effluent gas exceeds 0.02 grain per dry standard cubic foot.

   *  The internal combustion engines shall be designed and operated to either reduce NMOC by 98 weight-percent or to reduce the outlet NMOC concentration to less than 20 parts per million by volume, dry basis as hexane at 3% oxygen. The reduction efficiency or parts per million by volume shall be established by an initial performance test to be completed no later than 180 days after the initial startup of the source using the test methods specified in § 60.754(d).

   *  Within 60 days after achieving the normal production rate at which the affected source will be operated, but not later than 180 days after initial start-up of the control device, a stack test shall be performed in accordance with the provisions of 25 Pa. Code Chapter 139. The stack test shall be performed while the aforementioned source is operating at the maximum or normal rated capacity as stated on the application. The stack test shall be conducted for NOx, CO and VOC (NMOC).

   *  The permittee shall maintain comprehensive accurate records which, at a minimum, shall include:

   *  The number of hours per calendar year that each engine or piece of equipment operated.

   *  The amount of fuel used per calendar year in each engine or piece of equipment.

*  When a new internal combustion engine is installed and is required to conduct a performance test, the permittee shall maintain records or report the following:

   *  Records including a description of testing methods, results, all engine operating data collected during the tests and a copy of the calculations performed to determine compliance with emission standards.

   *  Copies of the report that demonstrates that the engines were operating at rated brake horsepower and rated speed conditions during performance testing.

*  These records shall be retained for a minimum of 2 years and shall be made available to the Department upon request. The Department reserves the right to expand the list contained in this condition as it may reasonably prescribe under the provisions of section 4 of the Pennsylvania Air Pollution Control Act (35 P. S. § 4004), and as it may deem necessary to determine compliance with any condition contained herein.

*  The permittee shall maintain a record of all preventative maintenance inspections of the source and control device. These records shall, at a minimum, contain the dates of the inspections, any problems or defects, the actions taken to correct the problem or defects and any routine maintenance performed.

*  The permittee shall maintain a record of the following from the operational inspections:

   *  Pressure drop across the catalyst.

   *  Differential temperature across the catalyst.

   *  The permittee shall perform a daily operational inspection of the source and control device for any day the source and control device is in operation.

   *  The permittee shall install a magnehelic gauge or equivalent to measure pressure drop across the control device. The gauge shall be maintained in good working order at all times. The permittee shall develop the normal operating range for the control device and shall submit the normal operating range to the Department for approval prior to applying for an operating permit.

   *  The permittee shall install a thermocouple or equivalent to measure differential temperature across the control device. The gauge shall be maintained in good working order at all times. The permittee shall develop the normal operating range for the control device and shall submit the normal operating range to the Department for approval prior to applying for an operating permit.

   *  All gauges employed (inlet/outlet catalyst temperature and pressure drop) shall have a scale such that the expected normal reading shall be no less than 20) of full scale and be accurate within +2% of full scale reading.

   *  The permittee shall operate the control device at all times that the source is in operation.

   *  The permittee shall maintain and operate the source and control device in accordance with the manufacturer's specifications and in accordance with good air pollution control practices.

   10-021O:  Indspec Chemical Corp. (133 Main Street, P. O. Box 307, Petrolia, PA 16050) for replacement of the burners on the Bertrams Units Nos. 1 and 2 (Sources 035 and 036) with Low NOx burners with the same rated heat input of the existing burners in Petrolia Borough, Butler County.

   In accordance with 25 Pa. Code §§ 127.44(b) and 127.424(b) the Department of Environmental Protection (Department) intends to issue a plan approval to Indspec Chemical Corporation in Petrolia Borough, Butler County. The facility was issued a Title V permit No.TV-10-00021 on November 2, 2000. This plan approval will, in accordance with 25 Pa. Code § 127.450, be incorporated into the Title V operating permit through an administrative amendment at a later date.

   Plan approval No. 1 is for the replacement of the burners on the Bertrams Units Nos. 1 and 2 (Sources 035 and 036) with Low NOx burners with the same rated heat input of the existing burners. The NOx emissions will decrease by approximately 4.75 tpy per unit. The CO emissions will increase by approximately 2.7 tpy per unit. The TSP, PM10, SOx and VOC emissions will remain relatively unchanged. The plan approval contains requirements for testing to demonstrate compliance with the CO and NOx emission limitations. The facility will be required to monitor the fuel usage, hours of operation, and use the emission data from AP-42 emission factors and the emission tests to calculate the 12-month rolling emissions. The facility will also be required to perform yearly maintenance on the burners. The Plan Approval and Operating Permit will contain additional monitoring, recordkeeping and work practice requirements designed to keep the facility operating within all applicable air quality requirements.

   Copies of the applications, Department's analysis and other documents used in the evaluation of the Applications are available for public review during normal business hours at the Northwest Regional DEP Office, 230 Chestnut St., Meadville, PA 16335.

   Persons wishing to provide Department with additional information that they believe should be considered prior to the issuance of this permit may submit the information to the address shown in the preceding paragraph. The Department will consider any written comments received within 30 days of the publication of this notice. Each written comment must contain the following:

Name, address and telephone number of the person submitting the comments.
Identification of the proposed permit Permit No. 10-021O.
A concise statement regarding the relevancy of the information or objections to the issuance of the permit.

   A public hearing may be held, if the Department, in its discretion, decides that a hearing is warranted based on the comments received. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, when the Department determines that telephone notification is sufficient. Written comments or requests for a public hearing should be directed to Matthew Williams, New Source Review, Air Quality Program, 230 Chestnut Street, Meadville, PA 16335, (814)-332-6940.

   Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodations to do so should by contacting Matthew Williams, or the Pennsylvania AT&T Relay Service at (800) 654-5984 (TDD) to discuss how the Department may accommodate their needs.

   If a plan approval has not undergone the public notice process the change to an operating permit must be treated as a significant modification. In these situations the Department should follow the procedures described in 25 Pa. Code §§ 127.421 to 127.431 for State-only operating permits or 25 Pa. Code §§ 127.521 to 127.524 for Title V operating permits.


Intent to Issue Operating Permits under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter F.

   Southeast Region:  Air Quality Program, 2 East Main Street, Norristown, PA 19428, Edward Jurdones Brown, Facilities Permitting Chief, (484) 250-5920.

   23-00106:  BPG Real Estate Investors--Straw Party 1 LP (3815 West Chester Pike, Newtown Square, PA 19073) for operation of three boilers, one emergency generator and one fire pump located at the Ellis Preserve at Newtown Square in Newtown Township, Delaware County. The permit is for a non-Title V (State-only) facility. The facility has elected to cap NOx and SOx to less than major facility thresholds; therefore, the facility is a Synthetic Minor. The permit will include monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

   46-00253: Valley Forge, Inc. (450 East Valley Forge Road, King of Prussia, PA 19406) for a non-Title V Facility, State-only, Synthetic Minor Operating Permit in Upper Merion Township, Montgomery County. Valley Forge, Inc. recycles used concrete, asphalt, brick and block and crushes it for use in road subbase and other construction products; grinds green waste into mulch; and processes compost and topsoil. The facility's major sources of emissions are the engines, from which the main pollutant emitted is NOx. Valley Forge, Inc., will limit the hours of operation in order to limit their facility NOx emissions to less than 11.1 tons per year. The permit will contain monitoring, recordkeeping, reporting and work practice requirements designed to keep the facility operating within all applicable air quality requirements.

   Southcentral Region:  Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, Ronald Davis, New Source Review Chief, (717) 705-4702.

   21-03004: ADM Milling Co. (P. O. Box 3100, Shiremanstown, PA 17011) for operation of their flour milling facility in Camp Hill Borough, Cumberland County. The facility is subject to 40 CFR Part 60, Subpart DD-Standards of Performance for Grain Elevators. This is a non-Title V (State-only) facility. The State-only operating permit shall contain testing, monitoring, recordkeeping and reporting requirements, emission restrictions and work practice standards designed to keep the facility operating within all applicable air quality requirements. This is a renewal of the facility's previous operating permit.

   36-03157: Fertrell Co. (P. O. Box 265, Bainbridge, PA 17502) for operation of their fertilizer plant in Conoy Township, Lancaster County. Actual emissions are expected to be 10 tons per year of SO, 2 tons per year of NOx and 2 tons per year of PM. The State-only permit will include monitoring, work practices, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

   Northcentral Region:  Air Quality Program, 208 West Third Street, Williamsport, PA 17701, David Aldenderfer, Program Manager, (570) 327-3637.

   60-00020: Pik Rite, Inc. (60 Pik Rite Lane, Lewisburg, PA 17837) for operation of a steel parts fabricating and surface coating facility in Buffalo Township, Union County.

   The facility incorporates two spray booths in which farm equipment and other fabricated steel items are painted as well as 15 small propane-fired space heaters and a 300 gallon diesel fuel storage tank. The air contaminant emissions from the facility are not expected to exceed 4.98 tons of VOCs, 1.3 tons of volatile HAPs, 11.28 tons of PM10, .77 ton NOx, .11 ton of CO and .083 tons of SOx per year.

   The facility is not a major (Title V) facility for any air contaminant.

   The Department of Environmental Protection proposes to incorporate into the operating permit to be issued conditions requiring compliance with all applicable regulatory requirements pertaining to air contamination sources and the emission of air contaminants as well as conditions previously established in Plan Approval 60-318-011A, issued on November 1, 2005, and modified on May 15, 2006.

   The previously-established conditions include:

   1.  No more than a combined total of 2,248 gallons of coating used in the surface coating operation in any 12-consecutive month period shall contain VOCs in excess of 1.69 pounds per gallon of coating, as mixed for application, and no coating shall contain VOCs in excess of 2.74 pounds per gallon of coating, as mixed for application.

   2.  No more than a combined total of 1,400 gallons of coating used in the surface coating operation in any 12-consecutive month period, as mixed for application, shall contain any volatile HAPs, of which no more than 500 gallons in any 12-consecutive month period shall contain volatile HAPs in excess of .36 pound per gallon of coating, as mixed for application, and none shall contain volatile HAPs in excess of 1.2 pounds per gallon of coating, as mixed for application.

   3.  No more than 15 gallons of adhesives shall be used in any 12-consecutive month period and no adhesive shall contain VOCs or volatile HAPs in excess of 5.09 pound per gallon of adhesive, as mixed for application.

   4.  No more than 696 gallons of cleanup solvent shall be used in any 12-consecutive month period, of which no more than 600 gallons shall contain any VOCs or volatile HAPs. No cleanup solvent shall contain volatile hazardous air pollutants in excess of 3.31 pounds per gallon of solvent.

   5.  The total combined VOC emissions from the surface coating operation shall not exceed 4.95 tons in any 12-consecutive month period and the total combined volatile HAP emissions shall not exceed 1.5 tons in any 12-consecutive month period.

   6.  Coatings applied in the surface coating operation shall be applied by brush or wiping cloth or by high volume low pressure (HVLP) spray technology (or an application technique determined by the Department of Environmental Protection to have an equivalent transfer efficiency).

   7.  Surface coating performed at this site shall take place in spray booths which are exhausted to the atmosphere through spray booth filters except that coatings can be applied by brush or wiping cloth outside of the spray booths. The particulate matter emission rate from the spray booth shall not exceed .01 grain per dry standard cubic foot of exhaust.

   8.  All coatings used in the surface coating operation shall comply with 25 Pa. Code § 129.52.

   9.  VOC-containing, volatile HAP-containing and acetone-containing materials used in the surface coating operation shall be stored in closed containers when not in actual use. Spray lines, guns, and the like, shall be cleaned by either flushing a solid liquid stream of solvent into an appropriate container or by soaking equipment in closed containers of liquid solvent. Under no circumstances shall cleaning solvent be sprayed or flushed from a spray gun or line into the air. Under no circumstances shall cleaning solvent be flushed from a spray gun or line into a container in such a manner that it is atomized. Used cleaning solvent and all used cleaning rags or cloths shall be stored in closed containers and shall never be treated in any manner which would unnecessarily promote the evaporative loss of cleaning solvent to the atmosphere.

   10.  Records shall be maintained of the identity, composition and amount of each coating, coating component, coating additive, adhesive, cleaning solvent, and the like used each month. If a coating is mixed onsite from multiple components or if a coating has an additive (other than water) mixed with it onsite, records shall also be maintained of the identity and composition of each of the coating components mixed together, as well as the mix ratio, for each different batch of coating mix.

[Continued on next Web Page]



No part of the information on this site may be reproduced for profit or sold for profit.

This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.