NOTICES
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Applications, Actions and Special Notices
APPLICATIONS
[42 Pa.B. 6899]
[Saturday, November 3, 2012]
THE CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT APPLICATIONS FOR NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS This notice provides information about persons who have applied for a new, amended or renewed NPDES or WQM permit, a permit waiver for certain stormwater discharges or submitted a Notice of Intent (NOI) for coverage under a General Permit. The applications concern, but are not limited to, discharges regarding industrial, animal or sewage waste, discharges to groundwater, discharges associated with municipal separate storm sewer systems (MS4), stormwater associated with construction activities or concentrated animal feeding operations (CAFO). This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92a and 40 CFR Part 122, implementing The Clean Streams Law (35 P. S. §§ 691.1—691.1001) and the Federal Clean Water Act (33 U.S.C.A. §§ 1251—1376).
Location Permit Authority Application Type or Category Section I NPDES Renewals Section II NPDES New or Amendment Section III WQM Industrial, Sewage or Animal Waste; Discharge into Groundwater Section IV NPDES MS4 Individual Permit Section V NPDES MS4 Permit Waiver Section VI NPDES Individual Permit Stormwater Construction Section VII NPDES NOI for Coverage under NPDES General Permits For NPDES renewal applications in Section I, the Department of Environmental Protection (Department) has made a tentative determination to reissue these permits for 5 years subject to effluent limitations and monitoring and reporting requirements in their current permits, with appropriate and necessary updated requirements to reflect new and changed regulations and other requirements.
For applications for new NPDES permits and renewal applications with major changes in Section II, as well as applications for MS4 Individual Permits and Individual Stormwater Construction Permits in Sections IV and VI, the Department, based upon preliminary reviews, has made tentative determinations of proposed effluent limitations and other terms and conditions for the permit applications. In accordance with 25 Pa. Code § 92a.32(d), the proposed discharge of stormwater associated with construction activities will be managed in accordance with the requirements of 25 Pa. Code Chapter 102. These determinations are published as proposed actions for comments prior to taking final actions.
Unless indicated otherwise, the United States Environmental Protection Agency (EPA) Region III Administrator has waived the right to review or object to proposed NPDES permit actions under the waiver provision in 40 CFR 123.24(d).
Persons wishing to comment on NPDES applications are invited to submit statements to the contact office noted before the application within 30 days from the date of this public notice. Persons wishing to comment on WQM permit applications are invited to submit statements to the office noted before the application within 15 days from the date of this public notice. Comments received within the respective comment periods will be considered in the final determinations regarding the applications. A comment submittal should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based.
The Department will also accept requests for public hearings on applications. A public hearing may be held if the responsible office considers the public response significant. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. The Department will postpone its final determination until after a public hearing is held.
Persons with a disability who require an auxiliary aid, service, including TDD users, or other accommodations to seek additional information should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
I. NPDES Renewal Applications
Northeast Region: Clean Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915. Phone: 570-826-2511.
NPDES No.
(Type)Facility Name &
AddressCounty &
MunicipalityStream Name
(Watershed No.)EPA Waived
Y/N?PA0033740
(Sewage)Whispering Hollow South MHP
139 Country Club Road
Northampton, PA 18067Northampton County
Allen TownshipUnnamed Tributary to Hokendauqua Creek (02C) Y PA0062880
(Sewage)KidsPeace Orchard Hills Campus
5300 KidsPeace Drive
Orefield, PA 18069Lehigh County
North Whitehall TownshipJordan Creek (2-C) Y
Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.
NPDES No.
(Type)Facility Name &
AddressCounty &
MunicipalityStream Name
(Watershed #)EPA Waived
Y/N?PA0261068 (CAFO) Meadow Lane Dairy
3392 Blue Rock Road
Lancaster, PA 17603Lancaster County /
Manor TownshipWest Branch of Little Conestoga Creek / TSF Y
Northwest Region: Clean Water Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481
NPDES No.
(Type)Facility Name &
AddressCounty &
MunicipalityStream Name
(Watershed#)EPA Waived
Y/N?PA0100129
(Sewage)Seneca Hills Campground
276 Damascus Road
Polk, PA 16342Venango County
Victory TownshipSandy Creek (16-G) Y
II. Applications for New or Expanded Facility Permits, Renewal of Major Permits and EPA Non-Waived Permit Applications
Southeast Region: Clean Water Program Manager, 2 East Main Street, Norristown, PA 19401
PA0053392, Storm Water, SIC Code 4581, UPS, Inc., 1 Hog Island Road, Philadelphia, PA 19153-3996. Facility Name: UPS Air Terminal and Distribution Center. This existing facility is located in Tinicum Township, Delaware County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Storm Water.
The receiving stream(s), Delaware River, is located in State Water Plan watershed 3-F and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on an average stormwater flow.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Annual Instant. Parameters Monthly Maximum Minimum Average Maximum Maximum Flow (MGD) XXX Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 CBOD5 XXX XXX XXX XXX Report XXX Chemical Oxygen Demand XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Oil and Grease XXX XXX XXX 15 XXX 30 Dissolved Iron XXX XXX XXX XXX Report XXX Propylene Glycol XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 002 are based on an average stormwater flow.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Annual Daily Instant. Parameters Monthly Maximum Minimum Average Maximum Maximum Flow (MGD) XXX Report XXX XXX XXX XXX pH XXX XXX 6.0 XXX XXX 9.0 Oil and Grease XXX XXX XXX 15 XXX 30 The proposed effluent limits for Outfall 003 are based on an average stormwater flow.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Annual Daily Instant. Parameters Monthly Maximum Minimum Average Maximum Maximum Flow (MGD) XXX Report XXX XXX XXX XXX pH XXX XXX 6.0 XXX XXX 9.0 Oil and Grease XXX XXX XXX 15 XXX 30 The proposed effluent limits for Outfall 004 are based on an average stormwater flow.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Annual Daily Instant. Parameters Monthly Maximum Minimum Average Maximum Maximum Flow (MGD) XXX Report XXX XXX XXX XXX pH XXX XXX 6.0 XXX XXX 9.0 Oil and Grease XXX XXX XXX 15 XXX 30 In addition, the permit contains the following major special conditions:
A. Change in Ownership
B. Fire Sprinkler System Discharge
C. Laboratory Certification
D. EDMR Requirement
E. Stormwater Condition
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is in effect.
PA0056766, Storm Water, SIC Code 4581, City of Philadelphia Department of Commerce—Division Of Aviation, Terminal E, Philadelphia, PA 19153. Facility Name: Philadelphia International Airport. This existing facility is located in City of Philadelphia, Philadelphia County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of Storm Water associated with industrial activities.
The receiving stream(s), Delaware River, Unnamed Tributary to Delaware River and Unnamed Tributary to Mingo Creek, is located in State Water Plan watershed 3-F and 3-G and is classified for Warm Water Fishes, Migratory Fishes and Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on stormwater.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Dec 1 - Jun 30 Report XXX XXX XXX XXX XXX pH (S.U.) Dec 1 - Jun 30 XXX XXX 6.0 XXX XXX 9.0 CBOD5 Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Chemical Oxygen Demand Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Suspended Solids Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Oil and Grease Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Nitrate-Nitrite as N Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Ammonia-Nitrogen Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Kjeldahl Nitrogen Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Phosphorus Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Iron Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Potassium Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Acetic Acid Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Ethylene Glycol Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Propylene Glycol Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Urea Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX The proposed effluent limits for Outfall 005 are based on stormwater.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Dec 1 - Jun 30 Report XXX XXX XXX XXX XXX pH (S.U.) Dec 1 - Jun 30 XXX XXX 6.0 XXX XXX 9.0 CBOD5 Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Chemical Oxygen Demand Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Suspended Solids Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Oil and Grease Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Nitrate-Nitrite as N Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Ammonia-Nitrogen Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Kjeldahl Nitrogen Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Phosphorus Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Iron Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Total Potassium Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Acetic Acid Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Ethylene Glycol Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Propylene Glycol Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX Urea Dec 1 - Jun 30 XXX XXX XXX Report XXX XXX The proposed effluent limits for Outfall 101 are based on stormwater.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Parameters Monthly Maximum Minimum Average Maximum Maximum Oil and Grease XXX XXX XXX 15 30 XXX TRPH XXX XXX XXX 15 30 XXX The proposed effluent limits for Outfall 201 are based on stormwater.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Parameters Monthly Maximum Minimum Average Maximum Maximum Oil and Grease XXX XXX XXX 15 30 XXX TRPH XXX XXX XXX 15 30 XXX In addition, the permit contains the following major special conditions:
I.
A. Remedial Measures (Public Nuisance)
B. BAT/ELG Reopener Clause
C. Property Rights
D. Change of Ownership
E. TMDL/WLA Analysis
F. Laboratory Certification
G. Sludge disposal
H. Product Contaminated Storm Water Runoffs
I. Tank Bottom Water
J. Definitions
K. BMPs for Petroleum Marketing Terminals
L. No urea requirement
II. Requirements applicable to stormwater outfalls
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is in effect.
PA0025437, Sewage, SIC Code 4952, North Coventry Municipal Authority, 1485 East Schuylkill Road, Pottstown, PA 19464. Facility Name: N Coventry Township STP. This existing facility is located in North Coventry Township, Chester County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Sewage.
The receiving stream(s), Schuylkill River, is located in State Water Plan watershed 3-D and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 2.01 MGD.
Mass (lb/day) Concentration (mg/l) Average Weekly Inst. Average Weekly Instant. Parameters Monthly Average Min. Monthly Average Max. Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Dissolved Oxygen XXX XXX 5.0 XXX XXX XXX Total Residual Chlorine XXX XXX XXX 0.5 XXX 1.6 CBOD5 (May 1 - Oct 31) 335 503 XXX 20 30 40 (Nov 1 - Apr 30) 419 671 XXX 25 40 50 Total Suspended Solids 503 754 XXX 30 45 60 Fecal Coliform (CFU/100 ml) May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Oct 1 - Apr 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Ammonia-Nitrogen (5/1 to 10/31) 168 XXX XXX 10 XXX 20 (11/1 to 4/30) 335 XXX XXX 20 XXX 40 Total Phosphorus 34 XXX XXX 2.0 XXX 4.0 In addition, the permit contains the following major special conditions:
• PCBs PMP Requirements
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is not in effect.
Northeast Region: Clean Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915. Phone: 570-826-2511.PA0008664, Industrial Waste, SIC Code 4911, UGI Development Company, 390 US Rt. 11, Hunlock Creek, PA 18621. Facility Name: Hunlock Creek Energy Center. This existing facility is located in Hunlock Township, Luzerne County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Industrial Wastewater including Non-contact cooling water, blow down, low volume wastewater and sewage.
The receiving stream(s), Susquehanna River, Unnamed Stream and Unnamed Tributary to Hunlock Creek, is located in State Water Plan watershed 5-B and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 50.5 MGD of non-contact cooling water.
Mass (lb/day) Concentration (mg/l) Average Weekly Average Daily Instant. Parameters Monthly Average Minimum Monthly Maximum Maximum Flow (MGD) report report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine XXX XXX XXX XXX 0.2
MaxXXX Temperature (°F) XXX XXX XXX XXX 99
MaxXXX Oil and Grease XXX XXX XXX 15.0 20.0 XXX Nitrate-Nitrite as N XXX XXX XXX Report XXX XXX Nitrate-Nitrite as N Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen XXX XXX XXX Report XXX XXX Total Nitrogen Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen Effluent Net Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen XXX Report
Total AnnualXXX XXX XXX XXX Ammonia-Nitrogen XXX XXX XXX Report XXX XXX Ammonia-Nitrogen Report
Total MoXXX XXX XXX XXX XXX Ammonia-Nitrogen XXX Report
Total AnnualXXX XXX XXX XXX Total Kjeldahl Nitrogen XXX XXX XXX Report XXX XXX Total Kjeldahl Nitrogen Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus XXX XXX XXX Report XXX XXX Total Phosphorus Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus Effluent Net Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus XXX Report
Total AnnualXXX XXX XXX XXX Total Aluminum XXX XXX XXX Report Report XXX Total Iron XXX XXX XXX Report Report XXX The proposed effluent limits for Outfall 003 are based on a design flow of 0.16 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Average Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine XXX XXX XXX XXX 0.2
MaxXXX Free Available Chlorine XXX XXX XXX 0.2 XXX 0.5 Total Suspended Solids XXX XXX XXX 30 XXX 100 Oil and Grease XXX XXX XXX 15 20.0 XXX Nitrate-Nitrite as N XXX XXX XXX Report XXX XXX Nitrate-Nitrite as N Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen XXX XXX XXX Report XXX XXX Total Nitrogen Effluent Net Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen XXX Report
Total AnnualXXX XXX XXX XXX Total Nitrogen Report
Total MoXXX XXX XXX XXX XXX Ammonia-Nitrogen XXX XXX XXX Report XXX XXX Ammonia-Nitrogen Report
Total MoXXX XXX XXX XXX XXX Ammonia-Nitrogen XXX Report
Total AnnualXXX XXX XXX XXX Total Kjeldahl Nitrogen XXX XXX XXX Report XXX XXX Total Kjeldahl Nitrogen Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus XXX XXX XXX Report XXX XXX Total Phosphorus Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus Effluent Net Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus XXX Report
Total AnnualXXX XXX XXX XXX Total Aluminum XXX XXX XXX Report Report XXX Total Chromium XXX XXX XXX 0.2 0.2 XXX Total Iron XXX XXX XXX Report Report XXX Total Zinc XXX XXX XXX 1.0 1.0 XXX The proposed effluent limits for Outfall 004 are based on a design flow of 0.00357 MGD of treated sewage.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine XXX XXX XXX 1.0 XXX 2.0 CBOD5 XXX XXX XXX 25 XXX 50 Total Suspended Solids XXX XXX XXX 30 XXX 60 Fecal Coliform (CFU/100 ml) May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1000 Oct 1 - Apr 30 XXX XXX XXX 2,000
Geo MeanXXX 10000 Nitrate-Nitrite as N XXX XXX XXX Report XXX XXX Nitrate-Nitrite as N Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen XXX XXX XXX Report XXX XXX Total Nitrogen Effluent Net Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen XXX Report
Total AnnualXXX XXX XXX XXX Total Nitrogen Report
Total MoXXX XXX XXX XXX XXX Ammonia-Nitrogen XXX XXX XXX Report XXX XXX Ammonia-Nitrogen Report
Total MoXXX XXX XXX XXX XXX Ammonia-Nitrogen XXX Report
Total AnnualXXX XXX XXX XXX Total Kjeldahl Nitrogen XXX XXX XXX Report XXX XXX Total Kjeldahl Nitrogen Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus XXX XXX XXX Report XXX XXX Total Phosphorus Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus Effluent Net Report
Total MoXXX XXX XXX XXX XXX Total Phosphorus XXX Report
Total AnnualXXX XXX XXX XXX In addition, the permit contains the following major special conditions:
• Chemical additives
• Chesapeake Bay monitoring
• Stormwater
• Cooling Intake
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-826-5472.
The EPA Waiver is in effect.
Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.PA0261912, Sewage, SIC Code 5812, Scooters Mountainside Tavern LLC, 4587 Chambersburg Road, Biglerville, PA 17307. Facility Name: Scooters Mountainside Tavern. This proposed facility is located in Franklin Township, Adams County.
Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated sewage.
The receiving stream(s), Dry Swale to Marsh Creek, is located in State Water Plan watershed 13-D and is classified for Cold Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.0015 MGD.
Mass (lb/day) Concentration (mg/l) Average Average Instant. Parameters Monthly Minimum Monthly Maximum Flow (MGD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 CBOD5 XXX XXX XXX 10.0 XXX 20.0 Total Suspended Solids XXX XXX XXX 10.0 XXX 20.0 Fecal Coliform (CFU/100 ml) XXX XXX XXX 200
Geo MeanXXX 1,000 Ammonia-Nitrogen XXX XXX XXX Report XXX XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.
The EPA Waiver is in effect.
PA0261378 A-1, Sewage, SIC Code 447110, Sheetz Inc., 5700 Sixth Avenue, Altoona, PA 16602. Facility Name: Sheetz Clarks Ferry Store 461. This existing facility is located in Reed Township, Dauphin County.
Description of Existing Activity: The application is for an amendment of an NPDES permit for an existing discharge of treated Sewage.
The receiving stream(s), Susquehanna River, is located in State Water Plan watershed 6-C and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.0075 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Instant. Parameters Monthly Maximum Minimum Monthly Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Dissolved Oxygen XXX XXX 5.0 XXX XXX XXX CBOD5 XXX XXX XXX 10 XXX 20 Total Suspended Solids XXX XXX XXX 10 XXX 20 Fecal Coliform (CFU/100 ml) XXX XXX XXX 200
Geo MeanXXX XXX Total Phosphorus XXX XXX XXX 0.5 XXX 1.0 Total Nitrogen XXX XXX XXX 5 XXX 10 The proposed monitoring requirements and, where appropriate, effluent limits for implementation of the Chesapeake Bay Tributary Strategy are as follows for Outfall 001.
Mass (lbs) Concentration (mg/l) Monthly Parameters Monthly Annual Minimum Average Maximum Ammonia—N Report Report XXX Report XXX Kjeldahl—N Report XXX XXX Report XXX Nitrate-Nitrite as N Report XXX XXX Report XXX Total Nitrogen Report Report XXX Report XXX Total Phosphorus Report Report XXX Report XXX Net Total Nitrogen Report 38 XXX XXX XXX Net Total Phosphorus Report 3.8 XXX XXX XXX * This permit contains conditions which authorize the permittee to apply nutrient reduction credits to meet the Net Total Nitrogen and the Net Total Phosphorus effluent mass limits, under the Department's Trading of Nutrients and Sediment Reduction Credits Policy and Guidelines (Document #392-0900-001, December 30, 2006). The condition includes the requirement to report the application of these credits in Supplemental Discharge Monitoring Reports (DMRs) submitted to the Department.
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.
The EPA Waiver is in effect.
Southwest Regional Office: Regional Manager, Clean Water, 400 Waterfront Drive, Pittsburgh, PA 15222-4745; 412-442-4000PA0254606, Sewage, Saltsburg Borough, 320 Point Street, Saltsburg, PA 15681. Facility Name: Saltsburg STP. This proposed facility is located in Saltsburg Borough, Indiana County.
Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated Sewage.
The receiving stream(s), Conemaugh River, is located in State Water Plan watershed 18-C and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.2 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Weekly Instant. Parameters Monthly Maximum Minimum Monthly Average Maximum Flow (MGD) 0.2 Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine XXX XXX XXX 0.5 XXX 1.0 CBOD5 Report Report
Wkly AvgXXX 25 38 50 BOD5 Raw Sewage Influent Report Report XXX Report XXX XXX Total Suspended Solids Raw Sewage Influent Report Report XXX Report XXX XXX Total Suspended Solids Report Report
Wkly AvgXXX 30 45 60 Fecal Coliform (CFU/100 ml) May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Oct 1 - Apr 30 XXX XXX XXX 2,000
Geo MeanXXX 10,000 In addition, the permit contains the following major special conditions: The permittee is permitted to discharge through Combined Sewer Overflows (CSOs) 002,003,004,005 and 006 to the Conemaugh River
The EPA Waiver is in effect.
III. WQM Industrial Waste and Sewerage Applications under The Clean Streams Law
Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.
WQM Permit No. 0109202, Amendment 12-1, Industrial Waste, Knouse Foods Cooperative, Inc., Hilltop 2 Spray Field, 800 Peach Glen-Idaville Road, Peach Glen, PA 17375.
This proposed facility is located in Tyrone & Huntingdon Townships, Adams County.
Description of Proposed Action/Activity: Seeking permit approval for the construction / operation of a spray irrigation field at Knouse's Peach Glen Plant. The site, known as Hilltop 2, has approximately 22.89 acres of available field, of which 21.4 acres will be wetted. The system will include a new pump house, forcemain, and distribution system capable of supplying up to 900 gallons per minute (gpm) to multiple zones within the spray irrigation field. Tail water from the system will be collected and returned to the existing Pond 3 via three (3) duplex pump stations. Fixed sprinklers will be used to distribute pre-treated effluent evenly within in the zones.
Southwest Region: Clean Water Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745
WQM Permit No. 0212401, Sewerage, Chatham University, Woodland Road, Pittsburgh, PA 15232
This proposed facility is located in Richland Township, Allegheny County
Description of Proposed Action/Activity: Application for the construction and operation of a sewage treatment plant.
WQM Permit No. 5612402, Sewerage, Ursina Borough, 418 Park Street, Confluence, PA 15424
This proposed facility is located in Ursina Borough, Somerset County
Description of Proposed Action/Activity: Application for the construction and operation of a sewage treatment plant.
WQM Permit No. WQG026189, Sewerage, North Huntingdon Township Municipal Authority, 11265 Center Highway, North Huntingdon, PA 15642
This proposed facility is located in North Huntingdon Township, Westmoreland County
Description of Proposed Action/Activity: Application for the construction and operation of a sewer system.
IV. NPDES Applications for Stormwater Discharges from MS4
V. Applications for NPDES Waiver Stormwater Discharges from MS4
VI. NPDES Individual Permit Applications for Discharges of Stormwater Associated with Construction Activities
Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI01
151235Lighthouse Youth Center
PO Box 38
Oxford, PA 19363Chester Oxford Borough Little Elk Creek (HQ-TSFMF) PAI01
151236Hearne Harkwoods
200 Whiteside Drive
Oxford, PA 19363Chester Lower Oxford Township Unnamed Tributary West Branch Big Elk Creek (HQ-TSF-MF) PAI01
231207Mar-J Properties, LLC
114 Yearsley Mill Road
Media, PA 19063Delaware Middletown Township Rocky Run (HQ-CWF-MF) PAI01
5106002-R—Phase 28Philadelphia International Airport
Terminal D-E
Philadelphia, PA 19153Philadelphia City of Philadelphia Delaware River (WWF) PAI01
511206Green Woods Charter School
119 Rector Street
Philadelphia, PA 19127Philadelphia City of Philadelphia Unnamed Tributary Schuylkill River (WWF-MF) Northeast Region: Watershed Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915.
Northampton County Conservation District: 14 Gracedale Ave., Greystone Building, Nazareth, PA 18064, 610-746-1971.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI024812013 John Forde
Palmerview Acquisition, L.P.
770 Township Line Rd.
Ste. 150
Yardley, PA 19067Northampton Palmer Twp. Shoeneck Creek, WWF, MF Lehigh County Conservation District: Lehigh Ag. Ctr., Ste. 102, 4184 Dorney Park Road, Allentown, PA 18104, 610-391-9583.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI023912022 William Mayo, Jr.
Big Bear Management Fund
c/o 1-A Realty, Inc.
7475 Hamilton Blvd.
P. O. Box 8
Trexlertown, PA 18087Lehigh Lower Macungie Twp. Little Lehigh Creek, HQ-CWF, MF
VII. List of NOIs for NPDES and/or Other General Permit Types
PAG-12 CAFOs
PUBLIC WATER SUPPLY (PWS) PERMITS Under the Pennsylvania Safe Drinking Water Act (35 P. S. §§ 721.1—721.17), the following parties have applied for PWS permits to construct or substantially modify public water systems.
Persons wishing to comment on permit applications are invited to submit statements to the office listed before the application within 30 days of this public notice. Comments received within this 30-day comment period will be considered in the formulation of the final determinations regarding an application. A comment should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.
Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.
The permit application and related documents are on file at the office listed before the application and available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.
Persons with a disability that require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
SAFE DRINKING WATER
Applications Received Under the Pennsylvania Safe Drinking Water Act
Southcentral Region: Water Supply Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110
Permit No. 3612533, Public Water Supply.
Applicant Knightscove Properties Municipality Fulton Township County Lancaster Responsible Official Thomas P. Knight, Principal
PO Box 274
Port Deposit, MD 21904Type of Facility Public Water Supply Consulting Engineer Charles A Kehew II, P.E.
James R. Holley & Associates, Inc.
18 South George Street
York, PA 17401Application Received: 10/3/2012 Description of Action Installation of chlorine contact tanks, demonstration of 4-log treatment of viruses and authorization of nitrate treatment system. Southwest Region: Water Supply Management Program Manager, 400 Waterfront Drive, Pittsburgh, Pa 15222-4745
Permit No. 2612504, Public Water Supply.
Applicant Pennsylvania American Water Company
300 Galley Road
McMurray, PA 15317[Township or Borough] Connellsville Township Responsible Official Scott Hilty, Engineer
Pennsylvania American Water Company
300 Galley Road
McMurray, PA 15317Type of Facility Water system Consulting Engineer Bankson Engineers, Inc.
267 Blue Run Road
PO Box 200
Indianola, PA 15051Application Received Date October 22, 2012 Description of Action Construction of two water booster pump stations located along Springfield Pike (SR 711).
MINOR AMENDMENT
Applications Received Under the Pennsylvania Safe Drinking Water Act
Northeast Region: Safe Drinking Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790
Application No. 4512504MA
Applicant Pennsylvania-American Water Co. [Township or Borough] Middle Smithfield Township
Monroe CountyResponsible Official David R. Kaufman, VP Engineering
Pennsylvania-American Water Co.
800 West Hersheypark Drive
Hershey, PA 17033Type of Facility Community Water System Consulting Engineer Daniel G. Rickard, PE
Pennsylvania-American Water Co.
100 North Pennsylvania Avenue
Wilkes-Barre, PA 18701
570-830-6531Application Received Date October 5, 2012 Description of Action Application for construction of a chlorine contact segment to meet the Groundwater Rule requirements for the Mid-Monroe CWS Well Nos. 3 & 5. Application No. 2400068
Applicant Paul J. Goettner [Township or Borough] Foster Township
Luzerne CountyResponsible Official Paul J. Goettner
239 Main Street, Suite 203
East Greenville, PA 18041
215-679-4784Type of Facility Community Water System Consulting Engineer NA Application Received Date October 1, 2012 Description of Action Application to transfer PWS Operation Permit No. 2400068 for Hyland Mobile Home Park to Paul J. Goettner. Southwest Region: Water Supply Management Program Manager, 400 Waterfront Drive, Pittsburgh, Pa 15222-4745
Application No. 6512514MA, Minor Amendment.
Applicant Highridge Water Authority
17 Maple Avenue
Blairsville, PA 15717[Township or Borough] Brush Valley Township Responsible Official George Sulkosky, Executive Director
Highridge Water Authority
17 Maple Avenue
Blairsville, PA 15717Type of Facility Water system Consulting Engineer Gibson-Thomas Engineering Co., Inc.
1004 Ligonier Street
PO Box 853
Latrobe, PA 15650Application Received Date October 2, 2012 Description of Action Installation of approximately 14,500 feet of waterline (Roundtop, Cresswell and Meyers Roads). Application No. 3012505MA, Minor Amendment.
Applicant Southwestern Pennsylvania Water Authority
1442 Jefferson Road
PO Box 187
Jefferson, PA 15344[Township or Borough] Center and Wayne Townships Responsible Official John W. Golding, Manager
Southwestern Pennsylvania Water Authority
1442 Jefferson Road
PO Box 187
Jefferson, PA 15344Type of Facility Water system Consulting Engineer Bankson Engineers, Inc.
267 Blue Run Road
PO Box 200
Indianola, PA 15051Application Received Date September 10, 2012 Description of Action Installation of approximately 21,700 feet of waterline (Oak Forest waterline project). Application No. 0212525MA, Minor Amendment.
Applicant Pennsylvania American Water Company
852 Wesley Drive
Mechanicsburg, PA 17055[Township or Borough] Bethel Park Responsible Official Bruce Brubaker, Engineering Project Manager
Pennsylvania American Water Company
852 Wesley Drive
Mechanicsburg, PA 17055Type of Facility Water system Consulting Engineer Bankson Engineers, Inc.
267 Blue Run Road
PO Box 200
Indianola, PA 15051Application Received Date October 23, 2012 Description of Action Painting and rehabilitation of the Rocky Ridge #20 water storage tank. Application No. 0212526MA, Minor Amendment.
Applicant Pennsylvania American Water Company
852 Wesley Drive
Mechanicsburg, PA 17055[Township or Borough] Liberty Borough Responsible Official Bruce Brubaker, Engineering Project Manager
Pennsylvania American Water Company
852 Wesley Drive
Mechanicsburg, PA 17055Type of Facility Water system Consulting Engineer Bankson Engineers, Inc.
267 Blue Run Road
PO Box 200
Indianola, PA 15051Application Received Date October 23, 2012 Description of Action Painting and rehabilitation of the Liberty Borough water storage tank. Application No. 2612503MA, Minor Amendment.
Applicant Pennsylvania American Water Company
852 Wesley Drive
Mechanicsburg, PA 17055[Township or Borough] South Union Responsible Official Bruce Brubaker, Engineering Project Manager
Pennsylvania American Water Company
852 Wesley Drive
Mechanicsburg, PA 17055Type of Facility Water system Consulting Engineer Bankson Engineers, Inc.
267 Blue Run Road
PO Box 200
Indianola, PA 15051Application Received Date October 23, 2012 Description of Action Painting and rehabilitation of the Hopwood water storage tank. Application No. 2612501MA, Minor Amendment.
Applicant North Fayette County Municipal Authority
1634 University Drive
PO Box 368
Dunbar, PA 15431[Township or Borough] Vanderbilt Borough Responsible Official Robert Softcheck, General Manager
North Fayette County Municipal Authority
1634 University Drive
PO Box 368
Dunbar, PA 15431Type of Facility Water system Consulting Engineer K2 Engineering, Inc.
234 Pittsburgh Street
Uniontown, PA 15401Application Received Date October 17, 2012 Description of Action Installation of approximately 3,000 feet of 12-inch diameter waterline. Application No. 2612502MA, Minor Amendment.
Applicant North Fayette County Municipal Authority
1634 University Drive
PO Box 368
Dunbar, PA 15431[Township or Borough] Georges Township Responsible Official Robert Softcheck, General Manager
North Fayette County Municipal Authority
1634 University Drive
PO Box 368
Dunbar, PA 15431Type of Facility Water system Consulting Engineer K2 Engineering, Inc.
234 Pittsburgh Street
Uniontown, PA 15401Application Received Date October 17, 2012 Description of Action Installation of approximately 3,000 feet of 12-inch diameter and 1,730 feet of 6-inch diameter waterline.
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.