NOTICES
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Applications, Actions and Special Notices
APPLICATIONS
[43 Pa.B. 228]
[Saturday, January 12, 2013]
THE CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT APPLICATIONS FOR NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS This notice provides information about persons who have applied for a new, amended or renewed NPDES or WQM permit, a permit waiver for certain stormwater discharges or submitted a Notice of Intent (NOI) for coverage under a General Permit. The applications concern, but are not limited to, discharges regarding industrial, animal or sewage waste, discharges to groundwater, discharges associated with municipal separate storm sewer systems (MS4), stormwater associated with construction activities or concentrated animal feeding operations (CAFO). This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92a and 40 CFR Part 122, implementing The Clean Streams Law (35 P. S. §§ 691.1—691.1001) and the Federal Clean Water Act (33 U.S.C.A. §§ 1251—1376).
Location Permit Authority Application Type or Category Section I NPDES Renewals Section II NPDES New or Amendment Section III WQM Industrial, Sewage or Animal Waste; Discharge into Groundwater Section IV NPDES MS4 Individual Permit Section V NPDES MS4 Permit Waiver Section VI NPDES Individual Permit Stormwater Construction Section VII NPDES NOI for Coverage under NPDES General Permits For NPDES renewal applications in Section I, the Department of Environmental Protection (Department) has made a tentative determination to reissue these permits for 5 years subject to effluent limitations and monitoring and reporting requirements in their current permits, with appropriate and necessary updated requirements to reflect new and changed regulations and other requirements.
For applications for new NPDES permits and renewal applications with major changes in Section II, as well as applications for MS4 Individual Permits and Individual Stormwater Construction Permits in Sections IV and VI, the Department, based upon preliminary reviews, has made tentative determinations of proposed effluent limitations and other terms and conditions for the permit applications. In accordance with 25 Pa. Code § 92a.32(d), the proposed discharge of stormwater associated with construction activities will be managed in accordance with the requirements of 25 Pa. Code Chapter 102. These determinations are published as proposed actions for comments prior to taking final actions.
Unless indicated otherwise, the United States Environmental Protection Agency (EPA) Region III Administrator has waived the right to review or object to proposed NPDES permit actions under the waiver provision in 40 CFR 123.24(d).
Persons wishing to comment on NPDES applications are invited to submit statements to the contact office noted before the application within 30 days from the date of this public notice. Persons wishing to comment on WQM permit applications are invited to submit statements to the office noted before the application within 15 days from the date of this public notice. Comments received within the respective comment periods will be considered in the final determinations regarding the applications. A comment submittal should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based.
The Department will also accept requests for public hearings on applications. A public hearing may be held if the responsible office considers the public response significant. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. The Department will postpone its final determination until after a public hearing is held.
Persons with a disability who require an auxiliary aid, service, including TDD users, or other accommodations to seek additional information should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
I. NPDES Renewal Applications
Northeast Region: Clean Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915. Phone: 570-826-2511.
NPDES No.
(Type)Facility Name &
AddressCounty &
MunicipalityStream Name
(Watershed No.)EPA Waived
Y/N?PA0051799
(Minor Sewage)Lehigh Carbon Community College
4525 Education Park Drive
Schnecksville, PA 18078-2502Lehigh County
North Whitehall TownshipUnnamed Tributary to Jordan Creek (2-C) Y PA0063631
(Sewage)Parkland High School STP
Cedar Crest Boulevard & Ritter Road
Allentown, PA 18104Lehigh County
South Whitehall TownshipJordan Creek (2-C) Y PAS122203
(Storm Water)Nestle Waters North American
305 Nestle Way
Breinigsville, PA 18031Lehigh County
Upper Macungie TownshipIron Run (2-C) Y PAS122202
(Storm Water)Nestle Waters Na Bottling Plant
405 Nestle Way
Breinigsville, PA 18031Lehigh County
Iron Run (2-C) Y
Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.
NPDES No.
(Type)Facility Name &
AddressCounty &
MunicipalityStream Name
(Watershed #)EPA Waived
Y/N?PA0051900
(Sew)Robeson Township Municipal Authority
8 Boonetown Road
Birdsboro, PA 19508Berks County
Robeson TownshipSchuylkill River / 3-C Y PA0084450
(IW)Raven Rock Mountain Complex
201 Beasley Drive Suite 100
Fort Detrick, MD 21702-5029Adams County
Liberty TownshipUNT to Miney Branch / 13-D Y PA0085332
(Sew)Delta Borough Municipal Authority
PO Box 278
Delta, PA 17314York County
Delta BoroughScott Creek / 7-I Y PA0081868
(Sew)Fairview Township
599 Lewisberry Road
New Cumberland, PA 17070-2399York County
Fairview TownshipSusquehanna
River / 7-EY PA0088765
(Sew)Nelson & Margaret Wenger
Millbrook Manor MHP
545 Mt. Airy Road
Stevens, PA 17578Lancaster County
West Cocalico TownshipIndian Run / 7-J Y PA0082198
(Sew)Peters Township
5000 Steele Avenue
PO Box 88
Lemasters, PA 17231Franklin County
Peters TownshipUNT Conococheage Creek / 13-C Y
Northcentral Region: Clean Water Program Manager, 208 West Third Street, Williamsport, PA 17701
NPDES No.
(Type)Facility Name &
AddressCounty &
MunicipalityStream Name
(Watershed No.)EPA Waived
Y/N?PA0112119
(Sewage)American Truck Plazas LLC
1460 N Ridge Road
Milton, PA 17847Northumberland County
Turbot TownshipLimestone Run (10-D) N
Northwest Region: Clean Water Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481
NPDES No.
(Type)Facility Name &
AddressCounty &
MunicipalityStream Name
(Watershed#)EPA Waived
Y/N?PA0035505
(Sewage)Faith Bldr Ed Programs
28500 Guys Mills Road
Guys Mills, PA 16327Crawford County
Randolph TownshipUnnamed Tributary of Woodcock Creek (16-A) Y
II. Applications for New or Expanded Facility Permits, Renewal of Major Permits and EPA Non-Waived Permit Applications
Southeast Region: Clean Water Program Manager, 2 East Main Street, Norristown, PA 19401
PA0057487, SIC Code 2491, Oldcastle Lawn & Garden Inc., 500 East Pumping Station Road, Quakertown, PA 18951. Facility Name: Oldcastle Lawn & Garden Quakertown Facility. This existing facility is located in Richland Township, Bucks County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage and stormwater from the facility.
The receiving stream(s), Tohickon Creek and Unnamed Tributary to Tohickon Creek, is located in State Water Plan watershed 2-D and is classified for Trout Stocking and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.001 MGD.
Mass (lb/day) Concentration (mg/l) Average Instant. Average Instant. Parameters Monthly Minimum Monthly Maximum Flow (GPD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Dissolved Oxygen XXX XXX 3.0 XXX XXX XXX Total Residual Chlorine XXX XXX XXX 0.5 XXX 1.2 CBOD5 XXX XXX XXX 10 XXX 20 Total Suspended Solids XXX XXX XXX 10 XXX 20 Fecal Coliform (CFU/100 ml) XXX XXX XXX 200
Geo MeanXXX 1,000 Ammonia-Nitrogen XXX XXX XXX 3.0 XXX 6.0 Total Phosphorus XXX XXX XXX Report XXX Report The proposed effluent limits for storm water Outfall 002 are:
Mass (lb/day) Concentration (mg/l) Average Average Daily Instant. Parameters Monthly Minimum Monthly Maximum Maximum Flow (GPD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX XXX XXX Report XXX CBOD5 XXX XXX XXX XXX Report XXX Chemical Oxygen Demand XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Oil and Grease XXX XXX XXX XXX Report XXX Total Kjeldahl Nitrogen XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Dissolved Iron XXX XXX XXX XXX Report XXX In addition, the permit contains the following major special conditions:
• Abandon STP When Municipal Sewers Available
• Remedial Measures
• No Stormwater in Sewage
• Necessary Property Rights
• Small Stream Discharge
• Change in Ownership
• TRC Minimization
• Sludge Disposal
• Stormwater Outfall
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is in effect.
PA0051497, SIC Code 3462, Lenape Forged Products Corporation, 1334 Lenape Road, West Chester, PA 19382-6893. Facility Name: Lenape Forged Products Corporation. This existing facility is located in Pocopson Township, Chester County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of contact cooling water and stormwater.
The receiving stream(s), Brandywine Creek, is located in State Water Plan watershed 3-H and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on an average stormwater flow.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Parameters Monthly Minimum Maximum Maximum pH (S.U.) XXX XXX XXX Report XXX XXX BOD5 XXX XXX XXX Report XXX XXX Chemical Oxygen Demand XXX XXX XXX Report XXX XXX Total Suspended Solids XXX XXX XXX Report XXX XXX Oil and Grease XXX XXX XXX Report XXX XXX Nitrate-Nitrite as N XXX XXX XXX Report XXX XXX Total Kjeldahl Nitrogen XXX XXX XXX Report XXX XXX Total Phosphorus XXX XXX XXX Report XXX XXX The proposed effluent limits for Monitoring Point 101 are based on a design flow of 0.03 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Instant. Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Dissolved Oxygen XXX XXX Report Report XXX XXX Temperature (°F) XXX XXX XXX XXX XXX 110 CBOD5 XXX XXX XXX Report Report XXX Total Suspended Solids XXX XXX XXX 30 60 75 Oil and Grease XXX XXX XXX 10 XXX 30 Total Nitrogen XXX XXX XXX Report Report XXX Ammonia-Nitrogen XXX XXX XXX Report Report XXX Total Phosphorus XXX XXX XXX Report Report XXX Total Copper XXX XXX XXX Report Report XXX Total Nickel XXX XXX XXX Report Report XXX In addition, the permit contains the following major special conditions:
A. Acquire Necessary Property Rights
B. Proper Sludge Disposal
C. WQM Permit Condition
D. BAT/ELG Reopener
E. 2° Change in Temperature
F. Stormwater Outfall Requirement
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is not in effect.
Northeast Region: Clean Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915. Phone: 570-826-2511.PAS602208, Storm Water, SIC Code 5093, H Blinderman & Son Inc., PO Box 908, Allentown, PA 18105. Facility Name: H Blinderman & Son Inc. This proposed facility is located in Hellertown Borough, Northampton County.
Description of Proposed Activity: The application is for a new NPDES permit for an existing discharge of Storm Water associated with industrial activities.
The receiving stream(s), Saucon Creek, is located in State Water Plan watershed 2-C and is classified for High Quality Waters—Cold Water Fishes and, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.000000 MGD (stormwater only).
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Suspended Solids XXX XXX XXX XXX Report XXX Total Dissolved Solids XXX XXX XXX XXX Report XXX Oil and Grease XXX XXX XXX XXX Report XXX Total Kjeldahl Nitrogen XXX XXX XXX XXX Report XXX Dissolved Iron XXX XXX XXX XXX Report XXX Total Iron XXX XXX XXX XXX Report XXX The proposed effluent limits* for Outfall 002 are based on a design flow of 0.000000 MGD (stormwater only).
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Suspended Solids XXX XXX XXX XXX Report XXX Total Dissolved Solids XXX XXX XXX XXX Report XXX Oil and Grease XXX XXX XXX XXX Report XXX Total Kjeldahl Nitrogen XXX XXX XXX XXX Report XXX Dissolved Iron XXX XXX XXX XXX Report XXX Total Iron XXX XXX XXX XXX Report XXX * In the absence of an available monitoring point, the facility will implement its PPC Plan and BMPs to protect stormwater from contamination in this drainage area.
In addition, the permit contains the following major special conditions:
• Necessary Property rights, Residuals management, ELG Reopener, Stormwater conditions
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-826-5472.
The EPA Waiver is in effect.
Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.Application No. PA0246859, Concentrated Animal Feeding Operation (CAFO), Amos L Hoover (Hickory Lane Farm Cafo), R D # 1 Box 706, Blain, PA 17006.
Amos L Hoover has submitted an application for an Individual NPDES permit for an existing CAFO known as Hickory Lane Farm Cafo, located in Jackson Township, Perry County.
The CAFO is situated near Unnamed Tributary to Bowers Run in Watershed 7-A, which is classified for High Quality Waters—Cold Water Fishes, and High Quality Waters—Cold Water Fishes. The CAFO is designed to maintain an animal population of approximately 1001.2 animal equivalent units (AEUs) consisting of 850 sows, 50 boars, 5,700 nursery swine, 3,050 finishing swine and 60 steers. Manure is collected in an underneath shallow pull plug pit and stored in a clay-lined earthen manure storage lagoon. A release or discharge to waters of the Commonwealth under normal operating conditions is not expected. Normal operating conditions are defined as conditions below a 25-year, 24-hour storm event.
The Department has conducted administrative and technical reviews of the application. Based on the preliminary review and application of lawful standards and regulations, the Department has made a tentative determination to issue an NPDES permit for the operation subject to the terms and conditions and monitoring and reporting requirements specified in the permit.
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.
The Environmental Protection Agency (EPA) permit waiver provision under 40 CFR 123.24(e) does not apply to this NPDES permit.
Application No. PA0261955, Concentrated Animal Feeding Operation (CAFO), S & A Kreider & Son Inc. (S & A Kreider & Sons Farm Cafo), 761 Spring Valley Road, Quarryville, PA 17566.
S & A Kreider & Son Inc. has submitted an application for an Individual NPDES permit for a new CAFO known as S & A Kreider & Sons Farm Cafo, located in East Drumore Township, Lancaster County.
The CAFO is situated near Jackson Run and Unnamed Stream in Watershed 7-K, which is classified for High Quality Waters—Cold Water Fishes. The CAFO is designed to maintain an animal population of approximately 2402.5 animal equivalent units (AEUs) consisting of Dairy animals. Manure is collected in an HDPE-lined storage lagoon, two circular concrete storage lagoons and a concrete lined storage lagoon. A release or discharge to waters of the Commonwealth under normal operating conditions is not expected. Normal operating conditions are defined as conditions below a 25-year, 24-hour storm event.
The Department has conducted administrative and technical reviews of the application. Based on the preliminary review and application of lawful standards and regulations, the Department has made a tentative determination to issue an NPDES permit for the operation subject to the terms and conditions and monitoring and reporting requirements specified in the permit.
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.
The Environmental Protection Agency (EPA) permit waiver provision under 40 CFR 123.24(e) does not apply to this NPDES permit.
Northcentral Regional Office: Regional Clean Water Program Manager, 208 W Third Street Suite 101, Williamsport, PA 17701-6448, Telephone: 570.327.3664.PA0232319, SIC Code 4952, Tammy J Sortman, 705 Northway Road, Williamsport, PA 17701. Facility Name: Tammy Sortman Subdivision. This proposed facility is located in Lock Haven City, Clinton County.
Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated sewage from a single residence currently experiencing a malfunctioning on-lot system.
The receiving stream(s), West Branch Susquehanna River, is located in State Water Plan watershed 9-B and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.0004 MGD.
Mass (lb/day) Concentration (mg/l) Average Average Instant. Parameters Monthly Minimum Monthly Maximum Flow (MGD) Report XXX XXX XXX XXX XXX pH XXX XXX 6.0 XXX XXX 9.0 CBOD5 XXX XXX XXX 25 XXX 50 Total Suspended Solids XXX XXX XXX 30 XXX 60 Fecal Coliform May 1 - Sep 30 XXX XXX XXX 200
XXX 1000 Oct 1 - Apr 30 XXX XXX XXX 2,000
XXX 10000 UV Intensity (No.) Clean
XXX XXX XXX XXX XXX In addition, the permit contains the following major special conditions:
• Annual Maintenance Reporting
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.
The EPA Waiver is in effect.
Southwest Regional Office: Regional Manager, Water Management, 400 Waterfront Drive, Pittsburgh, PA 15222-4745; 412-442-4000PA0000418, Industrial Waste, SIC Code 4941, Municipal Authority of the Borough of Derry Westmoreland County, 620 N Chestnut Street, Derry, PA 15627-1728. Facility Name: Municipal Authority of the Borough of Derry. This existing facility is located in Derry Borough, Westmoreland County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Industrial Waste.
The receiving stream(s), Unnamed Tributary to McGee Run, is located in State Water Plan watershed 18-D and is classified for Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.27 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine XXX XXX XXX 0.5 XXX 1.0 Total Suspended Solids XXX XXX XXX 30 XXX 60 Total Aluminum XXX XXX XXX 2.0 XXX 4.0 Total Iron XXX XXX XXX 2.0 XXX 4.0 Total Manganese XXX XXX XXX 1.0 XXX 2.0 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is in effect.
PAS326103, Storm Water, SIC Code 1629, Redevelopment Authority of Allegheny County, 425 Sixth Avenue, Suite 800, Pittsburgh, PA 15219. Facility Name: Carrie Furnace Redevelopment. This proposed facility is located in Rankin and Swissvale Boroughs, Allegheny County.
Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of untreated Storm Water.
The receiving stream(s), Monongahela River, is located in State Water Plan watershed 19-A and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.000000 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Suspended Solids XXX XXX XXX 30 60 XXX Total Aluminum XXX XXX XXX 4.0 8.0 XXX Total Iron XXX XXX XXX 2.0 4.0 XXX Total Manganese XXX XXX XXX 1.0 2.0 XXX The proposed effluent limits for Outfall 002 are based on a design flow of 0.000000 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Suspended Solids XXX XXX XXX 30 60 XXX Total Aluminum XXX XXX XXX 4.0 8.0 XXX Total Iron XXX XXX XXX 2.0 4.0 XXX Total Manganese XXX XXX XXX 1.0 2.0 XXX The proposed effluent limits for Outfall 003 are based on a design flow of 0.000000 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Suspended Solids XXX XXX XXX 30 60 XXX Total Aluminum XXX XXX XXX 4.0 8.0 XXX Total Iron XXX XXX XXX 2.0 4.0 XXX Total Manganese XXX XXX XXX 1.0 2.0 XXX The proposed effluent limits for Outfall 004 are based on a design flow of 0.000000 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Daily Instant. Parameters Monthly Maximum Minimum Monthly Maximum Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Suspended Solids XXX XXX XXX 30 60 XXX Total Aluminum XXX XXX XXX 4.0 8.0 XXX Total Iron XXX XXX XXX 2.0 4.0 XXX Total Manganese XXX XXX XXX 1.0 2.0 XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is in effect.
PA0026522, Sewage, West Mifflin Sanitary Sewer Municipal Authority, 1302 Lower Bull Run Road, West Mifflin, PA 15122-2902. Facility Name: New England STP. This existing facility is located in West Mifflin Borough, Allegheny County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Sewage.
The receiving stream(s), Unnamed Tributary of Monongahela River is located in State Water Plan watershed 19-C and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 101 are based on a design flow of 1.2 MGD.
Mass (lb/day) Concentration (mg/l) Average Weekly Average Weekly Instant. Parameters Monthly Average Minimum Monthly Average Maximum Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Dissolved Oxygen XXX XXX 5.0 XXX XXX XXX Total Residual Chlorine (Interim) XXX XXX XXX 1.0 XXX 3.3 (Final) XXX XXX XXX 0.02 XXX 0.06 CBOD5 250 376 XXX 25 37.5 50 BOD5 Raw Sewage Influent Report Report
Daily MaxXXX Report XXX XXX Total Suspended Solids Raw Sewage Influent Report Report
Daily MaxXXX Report XXX XXX Total Suspended Solids 300 450 XXX 30 45 60 Fecal Coliform (CFU/100 ml) May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Oct 1 - Apr 30 XXX XXX XXX 2,000
Geo MeanXXX 10,000 Ammonia-Nitrogen May 1 - Oct 31 20 30 XXX 2.0 3.0 4.0 Nov 1 - Apr 30 30 45 XXX 3.0 4.5 6.0 Total Phosphorus Report XXX XXX Report XXX XXX Total Nitrogen Report XXX XXX Report XXX XXX The EPA Waiver is not in effect.
PA0026883, Sewage, City of Beaver Falls, 715 15th Street, Beaver Falls, PA 15010-4124. Facility Name: Beaver Falls STP. This existing facility is located in Beaver Falls City, Beaver County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream, Beaver River is located in State Water Plan watershed 20-B and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Internal Outfall 101 and Relief Outfall 002 are based on a design flow of 4.8 MGD.
Mass (lb/day) Concentration (mg/l) Average Daily Average Weekly Instant. Parameters Monthly Maximum Minimum Monthly Average Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine XXX XXX XXX 0.5 XXX 1.6 CBOD5 1,001.4 1,502.1
Wkly AvgXXX 25 37.5 50 BOD5 Report Report XXX Report XXX XXX BOD5 Raw Sewage Influent Report Report XXX Report XXX XXX Total Suspended Solids Raw Sewage Influent Report Report XXX Report XXX XXX Total Suspended Solids 1,201.7 1,802.5
Wkly AvgXXX 30 45 60 Fecal Coliform (CFU/100 ml) May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Oct 1 - Apr 30 XXX XXX XXX 2,000
Geo MeanXXX 10,000 The EPA Waiver is not in effect.
III. WQM Industrial Waste and Sewerage Applications under The Clean Streams Law
Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.
WQM Permit No. 3612403, Sewerage, Mount Joy Borough Authority, 21 East Main Street, Mount Joy, PA 17552.
This proposed facility is located in Mount Joy Borough, Lancaster County.
Description of Proposed Action/Activity: Proposed replacement / enlargement of the existing 12-inch vitrified clay sanitary sewer main to a new 18-inch PVC sewer main and four manholes to mitigate existing flooding conditions.
WQM Permit No. 3192405 12-1, Sewerage, Wood-Broad Top-Wells Joint Municipal Authority, PO Box 7, Wood Township, PA 16694-0007.
This proposed facility is located in Wood Township, Huntingdon County.
Description of Proposed Action/Activity: Proposing the inclusion of a three-month maximum monthly average flow capacity of 0.168 million gallons per day (mgd).
WQM Permit No. 3471403 12-1, Sewerage, McAlisterville Area Joint Authority, PO Box 61, McAlisterville, PA 17049-0061.
This proposed facility is located in Fayette Township, Juniata County.
Description of Proposed Action/Activity: Upgrade / Replacement of the existing covered aerators with fine bubble diffusers, new blowers and mixers.
Southwest Region: Water Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745
WQM Permit No. 6312407, Sewerage, Cecil Township Municipal Authority, 3599 Millers Run Road, Suite 104, Cecil Township, PA 15321
This proposed facility is located in Cecil Township, Washington County
Description of Proposed Action/Activity: Application for the construction and operation of a sewer extension.
WQM Permit No. 6309403-A1, Sewerage, Cecil Township Municipal Authority, 3599 Millers Run Road, Suite 104, Cecil Township, PA 15321
This existing facility is located in Cecil Township, Washington County
Description of Proposed Action/Activity: Application for permit amendment.
WQM Permit No. 5612403, Sewerage, Jenner Area Joint Sewer Authority, 102 Saylor Street, Jennerstown, PA 15547
This proposed facility is located in Boswell Borough, Somerset County
Description of Proposed Action/Activity: Application for the construction and operation of a pump station.
Northwest Region: Clean Water Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481
WQM Permit No. WQG018858, Sewerage, William D. Holmes, 8758 Horseshoe Drive, Erie, PA 16510.
This proposed facility is located in Greene Township, Erie County.
Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant.
WQM Permit No. WQG018859, Sewerage, Brian Baldwin, 8422 Mill Street, Girard, PA 16417.
This proposed facility is located in Platea Borough, Erie County.
Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant to replace a malfunctioning on-lot system.
WQM Permit No. WQG018860, Sewerage, Marjorie G. Newcomer, 4950 Brown Road, Waterford, PA 16441.
This proposed facility is located in Greene Township, Erie County.
Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant to replace a malfunctioning on-lot system.
WQM Permit No. WQG018861, Sewerage, Giovanni A. Ciotti, 11299 Pennside Road, Albion, PA 16401.
This proposed facility is located in Conneaut Township, Erie County.
Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant to replace a malfunctioning on-lot system.
WQM Permit No. 6212405, Sewerage, Paul Zentz, 11558 Route 62, Tidioute, PA 16351.
This proposed facility is located in Limestone Township, Warren County.
Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant.
IV. NPDES Applications for Stormwater Discharges from MS4
V. Applications for NPDES Waiver Stormwater Discharges from MS4
VI. NPDES Individual Permit Applications for Discharges of Stormwater Associated with Construction Activities
Northeast Region: Watershed Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915.
Lehigh County Conservation District: Lehigh Ag. Ctr., Ste. 102, 4184 Dorney Park Rd., Allentown, PA 18104, 610-391-9583.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI023907005R(1) Jaindl Land Company
David Jaindl
3150 Coffeetown Rd.
Orefield, PA 18069Lehigh Upper Macungie Twp. Hassen Creek, HQ-CWF, MF PAI023912024 Randy and Joe, LLC
Randall Weston
2222 Sullivan Trail
Easton, PA 18040Lehigh Lower Macungie Twp. Spring Creek, HQ-CWF, MF Monroe County Conservation District: 8050 Running Valley Road, Stroudsburg, PA 18360, 570-629-3060.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI024506016R Hirshland & Company
1055 Westlakes Drive
Suite 300
Berwyn, PA 19312Monroe Mount Pocono Borough Forest Hills Run, HQ-CWF, MF PAI024512011 M.S. Logistics, LLC
101 Hodencamp Rd.
Suite 200
Thousand Oaks, CA 92360Monroe Coolbaugh Twp. Pocono Summit Lake, HQ-CWF, MF;
Tobyhanna Creek, HQ-CWF, MFNorthampton County Conservation District: 14 Gracedale Ave., Greystone Building, Nazareth, PA 18064, 610-746-1971.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI024806016R Spectrum Land Acquisition, Inc.
Kenneth Snyder
3312 Seventh St.
Whitehall, PA 18052Northampton Bushkill Township Monocacy Creek, HQ-CWF, MF Southwest Region: Waterways & Wetlands Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745. (412) 442.4315
Permit No. Applicant &
AddressCounty Municipality Stream Name PAI056312007 PennDOT District 12-0
PO Box 450,
825 N. Gallatin Avenue
Uniontown, PA 15401Washington North Strabane Township Little Chartiers Creek (HQ-WWF)
VII. List of NOIs for NPDES and/or Other General Permit Types
PAG-12 CAFOs
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.