PUBLIC WATER SUPPLY (PWS) PERMITS

 Under the Pennsylvania Safe Drinking Water Act (35 P. S. §§ 721.1—721.17), the following parties have applied for PWS permits to construct or substantially modify public water systems.

 Persons wishing to comment on permit applications are invited to submit statements to the office listed before the application within 30 days of this public notice. Comments received within this 30-day comment period will be considered in the formulation of the final determinations regarding an application. A comment should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.

 Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.

 The permit application and related documents are on file at the office listed before the application and available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.

 Persons with a disability that require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

SAFE DRINKING WATER


Applications Received Under the Pennsylvania Safe Drinking Water Act

Northeast Region: Safe Drinking Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915

Permit No. 3914505, Public Water Supply.

Applicant Nestle Waters North America, Inc.
Attention: Mr. Weaver
305 Nestle Way
Breinigsville, PA 18031
[Borough or Township] Upper Macungie Township
County Lehigh County
Type of Facility PWS
Consulting Engineer Mr. Edward E. Davis Sr., P.E.
Miller Brothers Construction, Inc.
P. O. Box 472
Schuylkill Haven, PA 17972-0472
(570) 385-1662
Application Received Date 07/09/2014
Description of Action Application for the addition of a granular activated carbon system, a mineral injection system, and re-positioning of UV units.

Southcentral Region: Safe Drinking Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110

Permit No. 0115504 MA, Minor Amendment, Public Water Supply.

Applicant The York Water Company
Municipality Cumberland Township
County Adams
Responsible Official Mark S. Snyder, Engineering Manager
130 East Market Street
PO Box 15089
York, PA 17405-7089
Type of Facility Public Water Supply
Consulting Engineer Mark S. Snyder, P.E.
The York Water Company
130 East Market Street
P. O. Box 15089
York, PA 17405-7089
Application Received: 3/11/2015
Description of Action Replacement of the existing softening system and the existing booster pumps. Installation of a new 36" GWR chlorine contact pipe.

Permit No. 3815502, Public Water Supply.

Applicant The Church of Jesus Christ of Latter-day Saints
Municipality North Cornwall Township
County Lebanon
Responsible Official Lanford Gatts, Facilities Manager
P. O. Box 483
Hollidaysburg, PA 16648
Type of Facility Public Water Supply
Consulting Engineer David R. Pollock, P.E.
BSEG, LLC
4949 Liberty Lane
Allentown, PA 18106
Application Received: 2/11/2015
Description of Action Installation of softening and nitrate removal systems. Dissolved oxygen reduction through the use of AquaMag is also being proposed.

Southwest Region: Safe Drinking Water Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

Permit No. 3015502, Public Water Supply.

Applicant Southwestern Pennsylvania Water Authority
1442 Jefferson Road
PO Box 187
Jefferson, PA 15344
[Township or Borough] Cumberland Township
Responsible Official John Golding, Manager
Southwestern Pennsylvania Water Authority
1442 Jefferson Road
P. O. Box 187
Jefferson, PA 15344
Type of Facility Water system
Consulting Engineer Bankson Engineers, Inc.
267 Blue Run Road
Suite 200
Cheswick, PA 15024
Application Received Date March 5, 2015
Description of Action Construction of plate settler clarifiers (Phase II WTP improvements).

Permit No. 0215510, Public Water Supply.

Applicant UPMC
200 Lothrop Street
Pittsburgh, PA 15213
[Township or Borough] City of Pittsburgh
Responsible Official John P. Krolicki
Vice President of Facilities and Support Services
UPMC
200 Lothrop Street
Pittsburgh, PA 15213
Type of Facility Western Psychiatric Institute & Clinic
Consulting Engineer Barclay Water Management
55 Chapel Street
Newton, MA 02458
Application Received Date February 24, 2015
Description of Action Installation of a secondary disinfection system (chloramination).

Permit No. 0215511, Public Water Supply.

Applicant UPMC
200 Lothrop Street
Pittsburgh, PA 15213
[Township or Borough] City of Pittsburgh
Responsible Official John P. Krolicki
Vice President of Facilities and Support Services
UPMC
200 Lothrop Street
Pittsburgh, PA 15213
Type of Facility Magee's Women's Hospital
Consulting Engineer Barclay Water Management
55 Chapel Street
Newton, MA 02458
Application Received Date March 6, 2015
Description of Action Installation of a secondary disinfection system (chloramination).

Permit No. 0215512, Public Water Supply.

Applicant UPMC
200 Lothrop Street
Pittsburgh, PA 15213
[Township or Borough] City of Pittsburgh
Responsible Official John P. Krolicki
Vice President of Facilities and Support Services
UPMC
200 Lothrop Street
Pittsburgh, PA 15213
Type of Facility Shadyside/Hillman Campus
Consulting Engineer Barclay Water Management
55 Chapel Street
Newton, MA 02458
Application Received Date March 11, 2015
Description of Action Installation of a secondary disinfection system (chloramination).

Northwest Region: Safe Drinking Water Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481

Permit No. 3315502, Public Water Supply

Applicant Tay Development LLC
Township or Borough Perry Township
County Jefferson
Responsible Official Tina Hoover
Type of Facility Restaurant
Consulting Engineer Brian Sekula, P.E.
Application Received Date 03/12/15
Description of Action Install a sodium hypochlorite chemical feed system and additional storage to ensure 4-log inactivation of viruses.

WATER ALLOCATIONS


Applications received under the act of June 24, 1939 (P. L. 842, No. 365) (35 P. S. §§ 631—641) relating to the Acquisition of Rights to Divert Waters of the Commonwealth

Southwest Region: Water Supply Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

WA11-1002A, Water Allocations. Ebensburg Borough Municipal Authority, 300 West High Street, Ebensburg, PA 15931, Cambria County. The applicant is requesting the right to withdraw 1.22 MGD annual average, with a one day maximum of 1.5 MGD from the Howell's Run Dam.

LAND RECYCLING AND ENVIRONMENTAL REMEDIATION

UNDER ACT 2, 1995
PREAMBLE 1


Acknowledgment of Notices of Intent to Remediate Submitted under the Land Recycling and Environmental Remediation Standards Act (35 P. S. §§ 6026.101—6026.907)

 Sections 302—305 of the Land Recycling and Environmental Remediation Standards Act (act) (35 P. S. §§ 6026.302—6026.305) require the Department to publish in the Pennsylvania Bulletin an acknowledgment noting receipt of Notices of Intent to Remediate. An acknowledgment of the receipt of a Notice of Intent to Remediate is used to identify a site where a person proposes to, or has been required to, respond to a release of a regulated substance at a site. A person intending to use the background standard, Statewide health standard, the site-specific standard or intend to remediate a site as a special industrial area shall file a Notice of Intent to Remediate with the Department. A Notice of Intent to Remediate filed with the Department provides a brief description of the location of the site, a list of known or suspected contaminants at the site, the proposed remediation measures for the site and a description of the intended future use of the site. A person who demonstrates attainment of one or a combination of cleanup standards or receives approval of a special industrial area remediation identified under the act will be relieved of further liability for the remediation of the site for contamination identified in reports submitted to and approved by the Department. Furthermore, the person shall not be subject to citizen suits or other contribution actions brought by responsible persons not participating in the remediation.

 Under sections 304(n)(1)(ii) and 305(c)(2) of the act, there is a 30-day public and municipal comment period for sites proposed for remediation using a site-specific standard, in whole or in part, and for sites remediated as a special industrial area. This period begins when a summary of the Notice of Intent to Remediate is published in a newspaper of general circulation in the area of the site. For the following site, proposed for remediation to a site-specific standard or as a special industrial area, the municipality, within which the site is located, may request to be involved in the development of the remediation and reuse plans for the site if the request is made within 30 days of the date specified as follows. During this comment period, the municipality may request that the person identified as the remediator of the site develop and implement a public involvement plan. Requests to be involved and comments should be directed to the remediator of the site.

 For further information concerning the content of a Notice of Intent to Remediate, contact the environmental cleanup program manager in the Department regional office listed before the notice. If information concerning this acknowledgment is required in an alternative form, contact the community relations coordinator at the appropriate regional office. TDD users may telephone the Department through the AT&T Relay Service at (800) 654-5984.

 The Department has received the following Notices of Intent to Remediate:

Northcentral Region: Environmental Cleanup & Brownfields Program Manager, 208 West Third Street, Williamsport, PA 17701

Trailer Convoys Inc., Interstate 80 @ MM192, Greene Township, Clinton County. Northridge Group, Inc., P.O. Box 231, Northumberland, PA 17857 on behalf of Trailer Convoys, Inc., P.O. Box 14, Jeffersonville, IN 47130 has submitted a Notice of Intent to Remediate. The release was 130-gallons of diesel fuel to the highway berm. The site was and will remain a right-of-way along the interstate roadway. The proposed cleanup standard for the site is Statewide Health. The Notice of Intent to Remediate was published in The Daily Item on February 24, 2015.

Northeast Region: Eric Supey, Environmental Cleanup and Brownfields Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915.

Lafayette College, 219 North Third Street, City of Easton, Northampton County. Moonstone Environmental LLC, 1150 Glenlivet Drive, Suite C-31, Allentown, PA 18106, on behalf of Lafayette College, 9 North Campus Drive, Easton, PA 18042, submitted a Notice of Intent to Remediate. During removal of underground storage tanks, detectable petroleum-related compounds (VOC's, SVOC's, and lead) were found in soil within the tank excavation areas, the proposed future use of the property is both residential and non-residential. The proposed cleanup standard for the site is the Site Specific Standard, and the Statewide Health Standard. The Notice of Intent to Remediate was published in The Morning Call on February 13, 2015.

Southcentral Region: Environmental Cleanup and Brownfields Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone 717.705.4705.

Woodstream Corporation, 69 North Locust Street, Lititz, PA 17543, Borough of Lititz, Lancaster County. RPS Gaia Tech, 135 South LaSalle Street, Suite 3500, Chicago, IL 60603, on behalf of Woodstream Corporation, 62 North Locust Street, Lititz, PA 17543, submitted a Notice of Intent to Remediate site soils and groundwater contaminated with chlorinated solvents from historical manufacturing operations. The site will be remediated to the Site Specific Standard. Future use of the site remains nonresidential and manufacturing. The Notice of Intent to Remediate was published in the Lititz Record Express on February 26, 2015.

OPERATE WASTE PROCESSING OR DISPOSAL AREA OR SITE


Application received, under the Solid Waste Management Act (35 P. S. §§ 6018.101—6018.1003), the Municipal Waste Planning, Recycling and Waste Reduction Act (53 P. S. §§ 4000.101—4000.1904) and regulations to operate a Solid Waste Processing or Disposal Area or Site.

Southwest Region: Regional Solid Waste Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745. Telephone 412-442-4000.

Permit ID No. WMGR123SW021. RES Water-Champion, LLC, 1373 Washington Pike, Suite 100, Bridgeville, PA 15017. Registration request for authorization for a processing facility for the beneficial use of oil and gas liquid waste proposed in Robinson Township, Washington County. Application was received in the Regional Office on February 26, 2015 and accepted for technical review on March 12, 2015.

AIR QUALITY

PLAN APPROVAL AND OPERATING PERMIT APPLICATIONS

 The Department has developed an ''integrated'' plan approval, State Operating Permit and Title V Operating Permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the general public. This approach allows the owner or operator of a facility to submit permitting documents relevant to its application for all sources related to a facility or a proposed project, affords an opportunity for public input, and provides for a decision on the issuance of the necessary permits.

 The Department received applications for Plan Approvals or Operating Permits from the following facilities.

 Copies of the application, the Department's analysis, all pertinent documents used in the evaluation of the application and subsequently prepared proposed plan approvals/operating permits are available for public review during normal business hours at the appropriate Department Regional Office. Appointments for scheduling a review must be made by calling the appropriate Department Regional Office. The address and phone number of the Regional Office is listed before the application notices.

 Persons wishing to file a written protest or provide comments or additional information, which they believe should be considered prior to the issuance of a permit, may submit the information to the Department's Regional Office. A 30-day comment period from the date of this publication will exist for the submission of comments, protests and information. Each submission must contain the name, address and telephone number of the person submitting the comments, identification of the proposed Plan Approval/Operating Permit including the permit number and a concise statement regarding the relevancy of the information or objections to issuance of the permit.

 A person wishing to request a hearing may do so during the 30-day comment period. A public hearing may be held, if the Department, in its discretion, decides that a hearing is warranted based on the information received. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper, the Pennsylvania Bulletin or by telephone, when the Department determines this type of notification is sufficient. Requests for a public hearing and any relevant information should be directed to the appropriate Department Regional Office.

 Permits issued to the owners or operators of sources subject to 25 Pa. Code Chapter 127, Subchapter D or E, or located within a Title V facility or subject to 25 Pa. Code § 129.51(a) or permits issued for sources with limitations on their potential to emit used to avoid otherwise applicable Federal requirements may be submitted to the United States Environmental Protection Agency for review and approval as a revision to the State Implementation Plan. Final Plan Approvals and Operating Permits will contain terms and conditions to ensure that the sources are constructed and operating in compliance with applicable requirements in the Air Pollution Control Act (35 P. S. §§ 4001—4015), 25 Pa. Code Chapters 121—145, the Federal Clean Air Act (42 U.S.C.A. §§ 7401—7671q) and regulations adopted under the Federal Clean Air Act.

 Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

PLAN APPROVALS


Plan Approval Applications Received under the Air Pollution Control Act (35 P. S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B that may have special public interest. These applications are in review and no decision on disposition has been reached.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481

Contact: Edward Orris, New Source Review Chief—Telephone: 814-332-6636

61-224A: Joy Global, Inc. Franklin Plant 1 (323 Buffalo Street, Franklin, PA 16323), for the construction of 2 paint booths in Franklin City, Venango County. This is a State Only facility.


Intent to Issue Plan Approvals and Intent to Issue or Amend Operating Permits under the Air Pollution Control Act and 25 Pa. Code Chapter 127, Subchapter B. These actions may include the administrative amendments of an associated operating permit.

Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

Contact: Mark R. Gorog, P.E., Environmental Engineer Manager—Telephone: 412-442-4150

04-00740A: Shell Chemical Appalachia LLC (910 Louisiana Street, OSP 14080C, Houston, TX 77002) Notice is hereby given in accordance with 25 Pa. Code §§ 127.44—127.46 that the Department of Environmental Protection (''Department'') intends to issue Air Quality Plan Approval: PA-04-00740A to Shell Chemical Appalachia LLC (''Shell'') for the construction of a petrochemicals complex to be located on the site formerly occupied by Horsehead Corporation's Monaca Zinc Smelter plant in Potter and Center Townships, Beaver County.

 The Department will hold a public hearing on Tuesday, May 5, 2015, from 6:00-8:00 PM at Central Valley High School, 160 Baker Road Extension, Monaca, PA 15061, to take oral testimony regarding this Air Quality Plan Approval application. Notice of this hearing is separately published within this Pennsylvania Bulletin.

 Polyethylene pellets will be the final manufactured product of this facility. The pellets will be produced from one of two gas phase or one slurry technology polyethylene production lines. Combined design capacity for the three polyethylene production lines will be 1.6 million metric tons of polyethylene pellets per year. Ethylene will be manufactured on site as an intermediate product at this facility. Ethylene will be produced by cracking ethane feedstock received by pipeline. Design capacity for ethylene production will be 1.5 million metric tons per year. The ethylene will be entirely used on site as the primary feedstock for the polyethylene production lines. Byproducts of the ethylene production process will include light gasoline, pyrolysis fuel oil, coke residue/tar, and a mixture of propane and heavier hydrocarbons. Three combustion turbines with duct burners and heat recovery steam generators will also be located at this facility to provide electricity and steam for use on site. Total electric generating capacity will be approximately 250 MW. Excess electricity will be sold to the grid in sufficient quantities to classify this facility as an electric utility.

 Air contamination sources and controls to be authorized at this site include:

 • Seven (7) tail gas- and natural gas-fired ethane cracking furnaces, 620 MMBtus/hr heat input rating each; equipped with low-NOx burners and controlled by selective catalytic reduction (SCR).

 • One (1) ethylene manufacturing line, 1,500,000 metric tons/yr; compressor seal vents and startup/shutdown/maintenance/upsets controlled by the high pressure header system (HP System).

 • Two (2) gas phase polyethylene manufacturing lines, 550,000 metric tons/yr each; VOC emission points controlled by the low pressure header system (LP System) or HP System, PM emission points controlled by filters.

 • One (1) slurry technology polyethylene manufacturing line, 500,000 metric tons/yr; VOC emission points controlled by the LP System or HP System, PM emission points controlled by filters.

 • One (1) LP System; routed to the LP incinerator, 10 metric tons/hr capacity, with backup multipoint ground flare (MPGF), 74 metric tons/hr total capacity.

 • One (1) HP System; routed to two (2) HP enclosed ground flares 150 metric tons/hr capacity each, with backup emergency elevated flare, 1,500 metric tons/hr capacity.

 • Three (3) General Electric, Frame 6B, natural gas-fired combustion turbines, 40.6 MW (475 MMBtus/hr heat input rating) each, including natural gas- or tail gas-fired duct burners, 189 MMBtus/hr heat input rating each; controlled by SCR and oxidation catalysts.

 • Four (4) diesel-fired emergency generator engines, 5,028 bhps rating each.

 • Three (3) diesel-fired fire pump engines, 700 bhp rating each.

 • One (1) process cooling tower, 28 cell counter-flow mechanical draft, 18.3 MMgals/hr water flow capacity; controlled by drift eliminators.

 • One (1) cogen cooling tower, 6 cell counter-flow mechanical draft, 4.44 MMgals/hr water flow capacity; controlled by drift eliminators.

 • Polyethylene pellet blending, handling, storage, and loadout; controlled by fabric filters.

 • Liquid loadout, coke residue/tar and recovered oil; controlled by vapor capture and routing back to the process or Spent Caustic Vent incinerator, and low-leak couplings.

 • Liquid loadout, pyrolysis fuel oil and light gasoline; controlled by vapor capture and routing to the LP System, and low-leak couplings.

 • Liquid loadout, C3+; controlled by pressurized transfer with vapor balance and low-leak couplings.

 • One (1) recovered oil, one (1) spent caustic, and two (2) equalization wastewater storage tanks, 23,775 to 742,324 gallon capacities; controlled by internal floating roofs (IFR) and vapor capture routed to the Spent Caustic Vent incinerator, 8 metric tons/hr capacity.

 • One (1) light gasoline, and two (2) hexene storage tanks; 85,856 and 607,596 gallon capacities; controlled by IFR and vapor capture routed to the LP System.

 • Two (2) pyrolysis fuel oil storage tanks; 85,856 gallon capacity; controlled by vapor capture routed to the LP System.

 • Miscellaneous storage tanks, diesel fuel, 1,849 to 10,038 gallon capacities; controlled by carbon canisters.

 • Miscellaneous components in gas, light liquid, and heavy liquid service; controlled by leak detection and repair (LDAR).

 • Wastewater treatment plant (WWTP).

 • Plant roadways; controlled by paving and a road dust control plan including sweeping and watering (as necessary).

 Potential to emit from the facility will be limited to not exceed the following:

Table 1: Facility Wide Potential to Emit

Air Contaminant Emission Rate
(tpy)
Nitrogen Oxides (NOx) 348
Carbon Monoxide (CO) 1,012
Filterable Particulate Matter (PM) 71
Particulate Matter Less Than 10
Microns In Diameter (PM10)
164
Particulate Matter Less Than 2.5
Microns In Diameter (PM2.5)
159
Sulfur Oxides (SOx) 21
Volatile Organic Compounds (VOC) 522
Hazardous Air Pollutants (HAP) 30.5
Ammonia (NH3) 152
Carbon Dioxide Equivalents (CO2e) 2,248,293

 This authorization is subject to Prevention of Significant Deterioration (PSD) requirements of 40 CFR 52.21; adopted in its entirety by the Department and incorporated by reference under 25 Pa. Code § 127.83; for nitrogen dioxide (NO2), CO, PM, PM10, and CO2e. In accordance with the PSD rules in 40 CFR 52.21 and 25 Pa. Code § 127.83, Shell has performed an air quality analysis which utilizes dispersion modeling. Shell's air quality analysis satisfies the requirements of the PSD rules and is consistent with the U.S. Environmental Protection Agency's (EPA) Guideline on Air Quality Models (40 CFR Part 51, Appendix W) and the EPA's air quality modeling policy and guidance.

 In accordance with 40 CFR 52.21(k), Shell's air quality analysis demonstrates that Shell's proposed emissions will not cause or contribute to air pollution in violation of the National Ambient Air Quality Standards (NAAQS) for CO, NO2, or PM10. Shell's air quality analysis demonstrates that Shell's proposed emissions will not cause or contribute to air pollution in violation of the increments for NO2 or PM10. The degree of Class II and Class I increment consumption expected to result from the operation of the Shell facility is provided in the following tables:

Table 2: Degree of Class II Increment Consumption from Operation of Shell Facility

Pollutant Averaging Period Degree of Class II Increment Consumption Class II Increment
micrograms/meter3 % of Class II Increment micrograms/meter3
NO2 Annual < 0.93919 < 3.76% 25
PM10 24-Hour < 8.43834 < 28.13% 30
Annual < 2.34454 < 13.79% 17

Table 3: Degree of Class I Increment Consumption from Operation of Shell Facility

Pollutant Averaging Period Degree of Class I Increment Consumption Class I Increment
micrograms/meter3 % of Class I Increment micrograms/meter3
NO2 Annual < 0.02342 < 0.94% 2.5
PM10 24-Hour < 0.27234 < 3.40% 8
Annual < 0.01954 < 0.49% 4

 In accordance with 40 CFR 52.21(o), Shell provided a satisfactory analysis of the impairment to visibility, soils, and vegetation that would occur as a result of the Shell facility and general commercial, residential, industrial, and other growth associated with the Shell facility. In accordance with 40 CFR 52.21(p), written notice of the proposed project has been provided to the Federal Land Managers of nearby Class I areas as well as initial screening calculations to demonstrate that Shell's proposed emissions will not adversely impact visibility and air quality related values (AQRV) in nearby Class I areas.

 In accordance with 40 CFR 52.21(l)(2), where an air quality model specified in the EPA Guideline on Air Quality Models (40 CFR Part 51, Appendix W) is inappropriate, the model may be modified on a case-by-case basis. Written approval of the EPA Regional Administrator must be obtained for the use of a modified model. In addition, the use of a modified model must be subject to notice and opportunity for public comment under procedures developed in accordance with 40 CFR 52.21(q). The air quality analysis for NO2 for the proposed Shell facility utilizes the Plume Volume Molar Ratio Method (PVMRM), which is currently implemented as a non-regulatory-default option within the EPA's recommended near-field dispersion model, the American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD). In accordance with the recommendations under subsection 3.2 of the EPA's Guideline on Air Quality Models, the Department submitted a request to EPA Region III for approval of the use of the PVMRM in Shell's air quality analysis for NO2 on March 31, 2014. The EPA Regional Administrator approved the Department's request on April 21, 2014. Pursuant to 25 Pa. Code §§ 127.44 and 127.83, and 40 CFR 52.21(l)(2) and (q), notice is hereby given that the Department is expressly soliciting written comments on the use of the PVMRM in Shell's air quality analysis for NO2.

 Shell has performed an inhalation risk assessment in order to evaluate potential cancer and noncancer inhalation risks from this facility's potential air emissions. Emission rates of compounds of potential concern (COPC) have been modeled to derive exposure concentrations. The highest modeled exposure concentrations were then multiplied or divided by compound-specific unit risk factors or reference concentrations, respectively. Chronic risks for each COPC were then summed and compared against the Department's benchmark excess lifetime cancer risk and health index (HI) values. Acute risks for each COPC were compared against the Department's benchmark hazard quotient (HQ) value.

Table 4: Inhalation Risk Assessment Results Summary

Inhalation Risk Department Benchmark Modeled Risk Less Than Benchmark?
Excess Lifetime Cancer Risk 1 in 100,000 0.8 in 100,000 Yes
Chronic Noncancer Risk HI < 0.25 HI = 0.07 Yes
Acute Noncancer Risk HQ < 1 HQ = 0.21 Yes

 The Department's technical review concludes that Shell's inhalation risk assessment was conducted according to the Department-approved protocol and is acceptable. Furthermore, the Department's independent inhalation risk assessment concludes that chronic cancer and noncancer risks as well as acute noncancer risks do not exceed the Department's benchmarks.

 This authorization is subject to New Source Review (NSR) requirements of 25 Pa. Code Chapter 127 Subchapter E for NOx, VOC, and PM2.5. These air contaminants are subject to Lowest Achievable Emission Rate (LAER) requirements. This location is designated as an area of nonattainment for the 2008 Lead NAAQS; however, lead emissions from this facility will be negligible because gaseous fuels, which contain little if any lead, will be combusted on site. NSR requirements have not been triggered for lead. Prior to commencing operation, Shell will be required to secure 400 tons of NOx, 620 tons of VOC, and 159 tons of PM2.5 emission reduction credits (ERCs) in order to offset emission increases from those air contaminants.

 This authorization is subject to State regulations including 25 Pa. Code Chapters 123—Standards for Contaminants; 127—Construction, Modification, Reactivation, and Operation of Sources; 129—Standards for Sources; 135—Reporting of Sources; 139—Sampling and Testing; and 145—Interstate Pollution Transport Reduction. Specific source standards include 25 Pa. Code §§ 129.56 and 129.57 for storage tanks containing VOCs, 25 Pa. Code § 129.65 for ethylene production plants, and 25 Pa. Code § 129.71 for LDAR requirements for ethylene and polyethylene manufacturing fugitive sources. State standards for contaminants and sources are superseded in most cases by more stringent BACT and LAER requirements. This authorization is also subject to Federal New Source Performance Standards (NSPS) including 40 CFR Part 60 Subparts Kb, VV, VVa, DDD, NNN, RRR, IIII, and KKKK; National Emission Standards for Hazardous Air Pollutants (NESHAP) including 40 CFR Part 61 Subparts J, V, and FF; and NESHAP including 40 CFR Part 63 Subparts SS, UU, XX, YY, FFFF, YYYY, and ZZZZ. Other applicable Federal regulations include 40 CFR Parts 52—Approval and Promulgation of Implementation Plans (specifically § 52.21—Prevention of Significant Deterioration of Air Quality), 64—Compliance Assurance Monitoring; 68—Chemical Accident Prevention Provisions; 72, 73, and 75—Permits Regulation, Sulfur Dioxide Allowance System, and Continuous Emission Monitoring; Part 96—NOx Budget Trading Program and CAIR NOx and SO2 Trading Programs for State Implementation Plans, and Part 98—Mandatory Greenhouse Gas Reporting.

 Plan approval conditions will include source specific and facility-wide emission limitations, operational restrictions, compliance testing and monitoring requirements, work practice standards, and associated recordkeeping and reporting requirements. The Department has determined that the proposed facility satisfies BACT, LAER, and the Department's Best Available Technology (BAT) requirements. Once compliance with the Plan Approval is demonstrated, the applicant will be required to submit a Title V Operating Permit (TVOP) application in accordance with 25 Pa. Code Subchapters F and G.

 A person may oppose the proposed plan approval by filing a written protest with the Department through Alan Binder via the U.S. Postal Service to Pennsylvania Department of Environmental Protection, 400 Waterfront Drive, Pittsburgh, PA 15222; email to abinder@pa.gov; or fax to 412.442.4194. Additional written comments may also be submitted. Each protest or set of written comments must contain the name, address and telephone number of the person submitting the comments, identification of the proposed Plan Approval (PA-04-00740A) and a concise statement of the objections to the plan approval issuance and the relevant facts upon which the objections are based.

 Shell's Plan Approval application, the Department's Air Quality Review Memorandum, and the Proposed Air Quality Plan Approval for this project are available for review by any interested party at the Pennsylvania Department of Environmental Protection, Southwest Regional Office, 400 Waterfront Drive, Pittsburgh, PA 15222. To request a review of the Shell Plan Approval Application, to receive an electronic copy of the Department's Air Quality Review Memorandum, or to receive an electronic copy of the Department's proposed air Quality Plan Approval for this project, a person may contact Phil Bouse at pbouse@pa.gov or 412.442.4000.

 All comments must be received prior to the close of business 30 days after the date of this publication.

Southcentral Region: Air Quality Program, 909 Elmer-ton Avenue, Harrisburg, PA 17110

Contact: Thomas Hanlon, Facilities Permitting Chief, 717-705-4762, Lisa Dorman, New Source Review Permitting Chief—Telephone: 717-705-4863 or William Weaver, Regional Air Quality Manager, Telephone: 717-705-4702.

21-05032A: Domestic Castings Company, LLC (275 N. Queen Street, Shippensburg, PA 17257) for the installation of one fabric filter to replace two older units and the upgrading of another fabric filter at the foundry in Shippensburg Township, Cumberland County. Overall particulate matter emissions (PM) from the foundry are not expected to increase. Reported actual facility PM emissions for calendar year 2013 were 14.75 tons. The Plan Approval includes emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. The foundry is subject to 40 CFR Part 63, Subpart ZZZZZ—National Emission Standards for Hazardous Air Pollutants for Iron and Steel Foundries Area Sources.

67-05005I: PPL Generation, LLC (2 North Ninth Street, Allentown, PA 18101) for the installation of a mercury dry sorbent injection (MDSI) system to control mercury emissions from the three existing coal-fired utility boilers at the Brunner Island Steam Electric Station located in East Manchester Township, York County. The MDSI system will consist of fully enclosed material transfer equipment and two mercury dry sorbent storage silos whose particulate matter (PM) emissions will be controlled by a dedicated bin vent collector during storage silo loading. The maximum expected increases in facility emissions as a result of the changes proposed are: 0.01 TPY PM; 0.01 TPY PM10; and 0.01 TPY PM2.5. The facility is a Title V facility. The Department's review of the information submitted by the applicant indicates that the air contamination sources as constructed or modified will comply with all regulatory requirements pertaining to air contamination sources and the emission of air contaminants including the best available technology (BAT) requirement of 25 Pa. Code §§ 127.1 and 127.12. Based on these findings, the Department proposes to issue a plan approval for the proposed construction. If, after the project has been implemented, the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specifications of the application for plan approval, the requirements established in the plan approval will be incorporated into the facility's Title V Operating Permit pursuant to the administrative amendment provisions of 25 Pa. Code § 127.450(a)(5).

Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701

Contact: Muhammad Q. Zaman, Environmental Program Manager—Telephone: 570-327-3648

59-00030A: Bass Wood Energy, LLC (6051 Wallace Road Extension, Suite 100, Wexford, PA 15090) for the construction of five (5) 6,023 bhp (4.4 MW) 4 stroke, lean burn Jenbacher J624 GS natural gas-fired engine/generator sets, each equipped with both catalytic oxidation and selective catalytic reduction (SCR), at the proposed electric generating station located in Duncan Township, Tioga County. The facility will also include one (1) 0.64 MMBtu/hour natural gas-fired natural gas line heater; three (3) storage tanks ranging in size from 2,600 gallons to 6,000 gallons; one (1) desiccant dehydration system; various fugitive emissions.

 The Department of Environmental Protection's (Department) review of the information submitted by Bass Wood Energy, LLC indicates that the air contamination sources to be constructed will comply with all regulatory requirements, including monitoring, recordkeeping, and reporting requirements, and pertaining to air contamination sources and the emission of air contaminants including the National Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines, 40 CFR Sections 63.6580 through 63.6675, the Standards of Performance for Stationary Spark Ignition Internal Combustion Engines, 40 CFR Sections 60.4230 through 60.4248, the Mandatory Greenhouse Gas Reporting Rule, 40 CFR Part 98, 25 Pa. Code Chapter 123 and the Best Available Technology requirement (BAT) of 25 Pa. Code §§ 127.1 and 127.12. Based on these findings, the Department proposes to issue a plan approval for the proposed construction.

 The emissions from each proposed engine included in this project will not exceed the following limits: 0.06 g/bhp-hr and 3.50 TPY NOx, 0.119 g/bhp-hr and 6.92 TPY CO, 0.076 g/bhp-hr and 4.42 TPY VOCs, 0.000588 lb/MMBtu and 0.083 TPY SOx, 0.024 g/bhp-hr and 1.40 TPY PM/PM10/PM2.5, 0.025 g/bhp-hr and 1.49 TPY formaldehyde, 10 ppmvd at 15% O2 ammonia; no visible emissions equal to or greater than 10% for a period or periods aggregating more than three minutes in any 1 hour and equal to or greater than 30% at any time.

 In addition to the emission limitations, the following is a brief description of the types of conditions the Department intends to place in the plan approval in order to ensure compliance with all applicable air quality regulatory requirements: Performance testing requirement for all engines to verify compliance with the emissions limitations; Establish a facility-wide leak detection and repair (LDAR) program to account for fugitive emissions; Restrict the engines to natural gas firing only; In addition to performance testing, establish follow-up portable analyzer testing for NOx and CO for all engines every 2,500 hours of operation.

 The facility is a State Only facility. If the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specifications of the application for Plan Approval 59-00030A, the applicant will subsequently apply for a State Only Operating Permit in accordance with 25 Pa. Code Subchapter F. All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

59-00031A: Pine Hill Energy, LLC (6051 Wallace Road Extension, Suite 100, Wexford, PA 15090) for the construction of five (5) 6,023 bhp (4.4 MW) 4 stroke, lean burn Jenbacher J624 GS natural gas-fired engine/generator sets, each equipped with both catalytic oxidation and selective catalytic reduction (SCR), at the proposed electric generating station located in Union Township, Tioga County. The facility will also include one (1) 0.64 MMBtu/hour natural gas-fired natural gas line heater; three (3) storage tanks ranging in size from 2,600 gallons to 6,000 gallons; one (1) desiccant dehydration system; various fugitive emissions.

 The Department of Environmental Protection's (Department) review of the information submitted by Pine Hill Energy, LLC indicates that the air contamination sources to be constructed will comply with all regulatory requirements, including monitoring, recordkeeping, and reporting requirements, and pertaining to air contamination sources and the emission of air contaminants including the National Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines, 40 CFR Sections 63.6580 through 63.6675, the Standards of Performance for Stationary Spark Ignition Internal Combustion Engines, 40 CFR Sections 60.4230 through 60.4248, the Mandatory Greenhouse Gas Reporting Rule, 40 CFR Part 98, 25 Pa. Code Chapter 123 and the Best Available Technology requirement (BAT) of 25 Pa. Code §§ 127.1 and 127.12. Based on these findings, the Department proposes to issue a plan approval for the proposed construction.

 The emissions from each proposed engine included in this project will not exceed the following limits: 0.06 g/bhp-hr and 3.50 TPY NOx, 0.119 g/bhp-hr and 6.92 TPY CO, 0.076 g/bhp-hr and 4.42 TPY VOCs, 0.000588 lb/MMBtu and 0.083 TPY SOx, 0.024 g/bhp-hr and 1.40 TPY PM/PM10/PM2.5, 0.025 g/bhp-hr and 1.49 TPY formaldehyde, 10 ppmvd at 15% O2 ammonia; no visible emissions equal to or greater than 10% for a period or periods aggregating more than three minutes in any 1 hour and equal to or greater than 30% at any time.

 In addition to the emission limitations, the following is a brief description of the types of conditions the Department intends to place in the plan approval in order to ensure compliance with all applicable air quality regulatory requirements: Performance testing requirement for all engines to verify compliance with the emissions limitations; Establish a facility-wide leak detection and repair (LDAR) program to account for fugitive emissions; Restrict the engines to natural gas firing only; In addition to performance testing, establish follow-up portable analyzer testing for NOx and CO for all engines every 2,500 hours of operation.

 The facility is a State Only facility. If the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specifications of the application for Plan Approval 59-00030A, the applicant will subsequently apply for a State Only Operating Permit in accordance with 25 Pa. Code Subchapter F. All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

41-00087B: Knight Confer Funeral Home, Inc. (1914 Memorial Avenue, Williamsport, PA 17701) for the construction of a human crematorium at the Knight Confer Funeral Home facility located in Williamsport, Lycoming County. The Department of Environmental Protection's (Department) review of the information submitted by Knight Confer Funeral Home indicates that the air contamination sources to be constructed will comply with all regulatory requirements pertaining to air contamination sources and the emission of air contaminants including the best available technology requirement (BAT) of 25 Pa. Code §§ 127.1 and 127.12. Based on this finding, the Department proposes to issue a plan approval for the proposed construction.

 The emissions from the proposed source included in this project will not exceed the following limits: 0.49 ton of nitrogen oxides (NOx, expressed as NO2) per year, 1.64 ton of carbon monoxide per year, 0.49 ton of volatile organic compounds per year and 4.65 tons of particulate matter per year.

 In addition to the emission limitations, the following is a brief description of the types of conditions the Department intends to place in the plan approval in order to ensure compliance with all applicable air quality regulatory requirements: 1. The particulate matter emissions from the crematory shall not exceed 0.08 grain per dry standard cubic foot of exhaust, corrected to 7% oxygen; 2. The visible emissions from the crematory shall not equal or exceed 10% opacity for a period or periods aggregating more than 3 minutes in any one hour or equal or exceed 30% opacity at any time; 3. The crematory shall only be fired on natural gas or LP gas; 4. Only human remains and associated containers, which are constructed of cardboard, particleboard or wood, shall be incinerated in the crematory. 5. Under no circumstances shall the crematory be used for the incineration of hospital waste, infectious waste or any other type of waste other than human remains and associated containers; 6. The crematory shall be equipped with instrumentation to continuously monitor and record the primary and secondary combustion chamber exit temperatures any time the crematory is in operation; 7. The crematory shall be equipped with instrumentation to continuously monitor the opacity of the effluent gas any time the crematory is in operation; 8. A secondary combustion chamber temperature of at least 1,800°F shall be maintained for a residence time of at least one (1) second at any time that cremation is occurring in the crematory; 9. The crematory shall be equipped with an interlock which prevents the primary combustion chamber burner from firing unless the secondary combustion chamber is at a temperature of at least 1,800°F; 10. The crematory shall be equipped with an interlock which prevents the primary combustion chamber burner from firing and sounds an alarm any time the opacity of the visible emissions exceeds 10%; 11. The charge door of the crematory shall be kept shut during the cremation cycle except for short periods of time in order to inspect and/or reposition the remains; 12. The permittee shall maintain accurate and comprehensive records of the primary and secondary combustion chamber temperature chart recordings.

 The facility is a State Only facility. If the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specification of the application for Plan Approval 41-00087B, the requirements established in the plan approval will be incorporated into a state only operating permit pursuant to 25 Pa. Code § 127.421. All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570.327.0550.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481

Contact: Edward Orris, New Source Review Chief—Telephone: 814-332-6636

20-040K: Advanced Cast Products (18711 Mill Street, Meadville, PA 16335), for the re-permitting of the particulate matter collection and control system for the facility's charge & pre-heating process (Source 101) and the facility's melting-transfer-magnesium treatment process (Source 102) due to the original plan approval 20-040I expiring in Vernon Township, Crawford County. This is a Title V facility. The public notice is required for sources required to obtain a Plan Approval in accordance with 25 Pa. Code § 127.44. This plan approval will, in accordance with 25 Pa. Code § 127.450 or § 127.505, be incorporated into the facility operating permit at a later date.

 Plan approval No 20-040K is for the proposed re-permitting of the particulate matter collection and control system for the facility's charge & pre-heating process (Source 101) and the facility's melting-transfer-magnesium treatment process (Source 102) due to the original plan approval 20-040I expiring on June 30, 2014. The application was received on January 16, 2015, and was administratively complete on February 4, 2015. This project will not result in an emission increase from what was originally permitted under plan approval 20-040I. This Plan Approval will contain emission restriction, testing, recordkeeping, work practice standard and additional requirement conditions, which will satisfy the requirements of 25 Pa. Code § 127.12b (pertaining to plan approval terms and conditions) and will demonstrate Best Available Technology (BAT) for the source including, but are not limited to, the following:

 Facility is now subject to the ''large foundry'' requirements of 40 CFR 63 ZZZZZ Sources 101 & 102:

 No person may permit the emission into the outdoor atmosphere of particulate matter in a manner that the concentration of total particulate matter (both filterable and condensable) in the effluent gas exceeds 0.020 grain per dry standard cubic foot.

 Emissions from the baghouse (BH15) shall not exceed the following:

 PM: 0.860 tpy based on a 12-month rolling total

 PM10: 0.813 tpy based on a 12-month rolling total

 The facility shall not exceed 30,000 tpy throughput based on a 12-month rolling total.

 Facility shall stack test for total PM (both filterable and condensable) while operating at 8 tons per hour or greater

 Facility shall record pressure drop daily and shall be maintained between 1.0 and 8.0 inches of water or as established during compliant testing.

 Facility shall record VE observations. VE observation shall be performed during tapping, if tapping operations are conducted during daylight hours. The VE observation shall be 60 seconds in length and if any visible emissions are observed, a Method 9 observation shall be conducted to determine compliance with the opacity limitations. The VE observations shall be done daily for a period of one month and if there is no detectable VE then the facility may perform weekly VE observations for a period of 4 weeks and if there is no detectable VE then the facility may perform monthly VE observations during tapping. Any observation of VE will start the sequence over again.

 The facility may bypass the baghouse only during idle periods and only for performing preventative maintenance and/or repairs on the baghouse. Idle periods are defined as periods when the facility is not in production (charging, melting, tapping, preheating, or treating iron).

 The permittee shall perform quarterly ''black-light'' leak inspections of the baghouse. An excursion is defined as a failure to perform and record the quarterly leak inspections.

 The permittee shall maintain and operate the source and control device in accordance with the manufacturer's specifications and in accordance with good air pollution control practices.

 All conditions from the facility operating permit dated December 11, 2012, for Sources 101 and 102 remain in effect unless modified in this plan approval.

 In accordance with 25 Pa. Code § 127.44(f)(1), all the pertinent documents regarding this application (applications, review memos, and draft approvals) are also available for review from 8:00 a.m. to 4:00 p.m. at the Meadville Regional DEP office (Air Quality). Appointments for scheduling a review must be made by calling the DEP at (814) 332-6340.

 In accordance with 25 Pa. Code § 127.44(f)(2), a 30-day comment period, from the date of publication, will exist for the submission of comments. Any person(s) wishing to provide DEP with additional information, which they believe should be considered prior to the issuance of this permit, may submit the information to Regional Air Quality Program Manager, Pennsylvania Department of Environmental Protection, 230 Chestnut Street, Meadville, PA 16335-3494 and must contain the name, address and telephone number of the person submitting the comments, identification of the proposed plan approval [20-040K] and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A public hearing may be held, if the Department of Environmental Protection, in its discretion, decides that such a hearing is warranted based on the comments received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, where DEP determines such notification is sufficient. Written comments or requests for a public hearing should be directed to Regional Air Quality Program Manager, 230 Chestnut St., Meadville, PA 16335; Phone (814) 332-6940.

 In accordance with 25 Pa. Code § 127.45, a person may oppose the proposed plan approval by filing a written protest with the Department's Northwest Region Air Quality Program Manager. If a plan approval has not undergone the above public notice process, the change to an operating permit must be treated as a significant modification. In these situations the Department should follow the procedures described in §§ 127.421 to 127.431 for state only operating permits or §§ 127.521 to 127.524 for Title V operating permits.

PLAN APPROVAL


PUBLIC HEARINGS

Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

Contact: William Charlton, New Source Review Chief—Telephone: 412-442-4174

04-00740A: Shell Chemical Appalachia LLC Petrochemicals Complex Proposed Plan Approval Authorization

Potter and Center Townships, Beaver County

 As per 25 Pa. Code § 127.48, notice is hereby given that the Pennsylvania Department of Environmental Protection (DEP) will hold a public hearing from 6:00-8:00PM on Tuesday, May 5, 2015, at the Central Valley High School, 160 Baker Road Extension, Monaca, PA 15061.

 The purpose of the hearing is to take testimony concerning the Department's intent to issue Plan Approval No. 04-00740A to Shell Chemical Appalachia LLC for the construction of a petrochemicals complex to be located on site formerly occupied by Horsehead Corporation's Monaca Zinc Smelter plant in Potter and Center Townships, Beaver County. The primary air emission sources to be constructed are seven ethane cracking furnaces, one ethylene manufacturing line, two gas phase and one slurry technology polyethylene manufacturing lines, three combined cycle turbines with duct burners (combined 250 MW generating capacity), one low pressure thermal incinerator, two high pressure ground flares, one multipoint ground flare, and one emergency elevated flare. Polyethylene pellets will be the final manufactured product of this facility. The Department is publishing a notice of intent to issue this plan approval in today's Pennsylvania Bulletin to allow for public comments regarding the proposed plan approval.

 In accordance with 25 Pa. Code §§ 127.48 and 127.49, the DEP will accept and record testimony concerning Shell's application. Those wishing to present testimony during the hearing should contact Community Relations Coordinator, John Poister, at 412.442.4203 before noon on May 5, 2015, to register. Individuals who do not register may also present testimony the day of the hearing. Organizations are encouraged to designate one witness to present testimony on behalf of the organization. Persons unable to attend the public hearing can submit three copies of a written statement to the DEP within 10 days thereafter. Written statements should be sent through Alan Binder via the U.S. Postal Service to Pennsylvania Department of Environmental Protection, 400 Waterfront Drive, Pittsburgh, PA 15222; email to abinder@pa.gov; or fax to 412.442.4194. Each written statement must contain the name, address and telephone number of the person submitting the comments, identification of the proposed plan approval (PA-04-00740A) and a concise statement of the objections to the plan approval issuance and the relevant facts upon which the objections are based.

 Individuals in need of an accommodation as provided for in the Americans With Disabilities Act of 1990 should contact John Poister or the Pennsylvania AT&T Relay Service at 1.800.654.5984 (TDD) to discuss how DEP may accommodate your needs.


Intent to Issue Operating Permits under the Air Pollution Control Act and 25 Pa. Code Chapter 127, Subchapter F.

Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401

Contact: Janine Tulloch-Reid, Facilities Permitting Chief—Telephone: 484-250-5920

09-00090: Praxair Distr Midatlantic LLC. (1 Steele Rd E Morrisville, PA 19067-3613) for the operation of the filling and recycling of gas cylinders for industry. It is located in Falls Township, Bucks County. The permit is for a non-Title V (State Only) facility. The facility's potential to emit criteria pollutants is less than major thresholds; therefore the facility is a Natural Minor. There are no applicable federal New Source Performance Standards (NSPS) or National Emission Standards for Hazardous Air Pollutants (NESHAP) for this facility. The permit will include monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

Southcentral Region: Air Quality Program, 909 Elmer-ton Avenue, Harrisburg, PA 17110

Contact: Thomas Hanlon, Facilities Permitting Chief, 717-705-4762, Lisa Dorman, New Source Review Permitting Chief—Telephone: 717-705-4863 or William Weaver, Regional Air Quality Manager, Telephone: 717-705-4702.

06-03146: Troutman Industries, Inc. (2201 Reading Avenue, West Lawn, PA 19609) for operation of their hard chrome plating operation in Spring Township, Berks County. Potential emissions from the facility are estimated to be 3.27 tpy VOC & 0.002 tpy of chromium compounds. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. Among other items, the conditions include provisions derived from 40 CFR 63 Subpart N—National Emission Standards for Chromium Emissions from Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks.

36-05137: B & S Woodcrafts, LLC (722 Truce Road, Quarryville, PA 17566) to issue a State Only Operating Permit for the wood furniture assembly and finishing operations located in Providence Township, Lancaster County. The actual emissions from the facility in 2013 year are estimated at 0.04 tpy of CO, 0.06 tpy of NOx, 9.79 tpy of VOCs and 2.18 tpy of HAPs. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. Among other items, the conditions include provisions derived from 25 Pa. Code § 129.52 Surface Coating Processes and 40 CFR Part 63 Subpart ZZZZ—National Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines.

06-05008: SFS Intec, Inc. (P. O. Box 6326, Wyomissing, PA 19610) for operation of a fastener manufacturing facility with surface coating operations controlled by water based coatings and dry filters in Wyomissing Borough, Berks County. Actual emissions from the facility in 2013 were estimated at 0.51 ton CO, 0.61 ton NOx, 0.05 ton PM10, & 10.01 tons VOC. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. Among other items, the conditions include provisions derived from 25 Pa. Code §§ 129.52 and 129.63.

Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701

Contact: Muhammad Q. Zaman, Environmental Program Manager—Telephone: 570-327-3648

19-00014: Hanson Aggregates Pennsylvania, LLC (7660 Imperial Way, Allentown, PA 18195-1040) to issue a renewal State Only Operating Permit for their Bloomsburg Quarry located in Hemlock Township, Columbia County. The facility is currently operating under State Only Operating Permit 19-00014. The facility's main sources include a stone crushing plant equipped with a water spray dust suppression system, a Remco vertical impact crusher equipped with a fabric collector, and an onsite network of unpaved haul roads. This renewal will incorporate the replacement of a Hewitt-Robbins jaw crusher with a similarly-seized Trio jaw crusher.

 The facility has potential emissions of 0.72 TPY of CO; 1.18 TPY of NOx; 0.06 TPY of SOx; 53.81 TPY of PM; 16.32 TPY of PM10; 1.59 TPY of VOCs.

 The Remco vertical impact crusher is subject to 40 CFR Part 60, Subpart OOO—Standards of Performance for Nonmetallic Mineral Processing Plants.

 The emission limits and work practice standards along with testing, monitoring, record keeping and reporting requirements have been included in the operating permit to ensure the facility complies with all applicable Federal and State air quality regulations. These operating permit conditions have been derived from the applicable requirements of 25 Pa. Code Chapters 121—145 as well as 40 CFR Part 60.

 All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

08-00008: Guthrie Robert Packer Hospital (1 Guthrie Square, Sayre, PA 18840) to issue a renewal State Only Operating Permit for their hospital located in Sayre Borough, Bradford County. The facility is currently operating under State Only Operating Permit 08-00008. The facility's main sources include three natural gas/No. 2 fuel oil fired boilers and five emergency diesel generators.

 The facility has potential emissions of 32.73 TPY of CO; 61.17 TPY of NOx; 97.26 TPY of SOx; 3.66 TPY of PM; 3.66 TPY of PM10; 3.51 TPY of VOCs and 0.74 TPY of HAPs.

 The emission limits and work practice standards along with testing, monitoring, record keeping and reporting requirements have been included in the operating permit to ensure the facility complies with all applicable Federal and State air quality regulations. These operating permit conditions have been derived from the applicable requirements of 25 Pa. Code Chapters 121—145 as well as 40 CFR Parts 60 and 63.

 All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

47-00012: HRI, Inc. (1750 West College Avenue State College, PA 16801) to issue a renewal State Only Operating Permit for the Milton hot mix asphalt plant located in Liberty Township, Montour County. The facility is currently operating under State Only Operating Permit 47-00012. The facility's main sources include a 300 ton per hour natural gas/No. 2 Fuel Oil/WDLF fired asphalt concrete plant, solvent degreasers and an emergency generator.

 The facility has potential emissions of 43.05 TPY of CO; 17.86 TPY of NOx; 98.69 TPY of SOx; 6.46 TPY of PM; 6.46 TPY of PM10; 19.16 TPY of VOCs and 2.10 TPY of HAPs.

 The emission limits and work practice standards along with testing, monitoring, record keeping and reporting requirements have been included in the operating permit to ensure the facility complies with all applicable Federal and State air quality regulations. These operating permit conditions have been derived from the applicable requirements of 25 Pa. Code Chapters 121—145 as well as 40 CFR Parts 60 and 63.

 All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

19-00028: White Pines Corporation (2650 Audubon Road, Audubon, PA 19403-2406) to issue a renewal State Only Operating Permit for the White Pines Landfill in Pine Township, Columbia County. The facility is currently operating under State Only Operating Permit 19-00028. The facility's main sources include one (1) diesel-fired engine-generator, one (1) double-deck screening operation, landfill cells, collection and perimeter wells.

 The facility has potential emissions of 0.40 TPY of CO; 2.26 TPY of NOx; 0.16 TPY of SOx; 31.52 TPY of PM; 31.52 TPY of PM10; 0.08 TPY of VOCs and 0.01 TPY of HAPs.

 The emission limits and work practice standards along with testing, monitoring, record keeping and reporting requirements have been included in the operating permit to ensure the facility complies with all applicable Federal and State air quality regulations. These operating permit conditions have been derived from the applicable requirements of 25 Pa. Code Chapters 121—145 as well as 40 CFR Parts 60 and 63.

 All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-3693.

41-00075: Construction Specialties, Inc. (P. O. Box 380, Muncy, PA 17756) to issue a renewal State Only Operating Permit for their facility in Montgomery Borough, Lycoming County. The facility is currently operating under State Only Operating Permit 41-00075. The facility's main sources include one (1) natural gas fired boiler, a surface coating operation consisting of three (3) spray booths, and a woodworking operation.

 The facility has potential emissions of 0.05 TPY of CO; 0.60 TPY of NOx; 0.01 TPY of SOx; 8.92 TPY of PM; 8.92 TPY of PM10; 8.03 TPY of VOCs and 1.86 TPY of HAPs.

 The emission limits and work practice standards along with testing, monitoring, record keeping and reporting requirements have been included in the operating permit to ensure the facility complies with all applicable Federal and State air quality regulations. These operating permit conditions have been derived from the applicable requirements of 25 Pa. Code Chapters 121—145 as well as 40 CFR Parts 60 and 63.

 All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-3693.

Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745

Contact: Barbara Hatch, Facilities Permitting Chief—Telephone: 412-442-4174

30-00148: Dana Mining Company, LLC (308 Dents Run Road, Morgantown, WV 26501) for a facility-wide Natural Minor Operating Permit renewal for the operation of a coal preparation plant, known as the 4 West Deep Mine Coal Preparation Plant, located in Dunkard Township, Greene County. The facility contains air contamination sources consisting of coal stockpiles, conveyers, screens, loadout, and roadways. Air pollution prevention equipment at the facility includes enclosures, a water truck, and tarping of truck loads. Raw coal throughput is limited to a maximum of 4,000,000 tons per year. Facility emissions are 26.4 tons of PM10 per year. The facility is limited to a maximum opacity from any processing equipment of 20 percent. The facility is subject to the applicable requirements of 40 CFR 60, Subpart Y, 40 CFR 63, Subpart IIII, and 25 Pa. Code Chapters 121—145. The permit includes emission limitations, and operational, monitoring, testing, reporting and recordkeeping requirements for the facility.

32-00424: Western Allegheny Energy, LLC (301 Market Street, Kittanning, PA 16201) for an initial facility-wide Natural Minor Operating Permit for the operation of a coal preparation plant, known as the Brush Valley Mine Coal Preparation Plant, located in Center Township, Indiana County. The facility contains air contamination sources consisting of coal stockpiles, conveyers, screens, wet coal cleaning plant, two emergency diesel engines (732-bhp, and 287-bhp), and roadways. Air pollution prevention equipment at the facility includes enclosures, a water truck, sweeper, and tarping of truck loads. Raw coal throughput is limited to a maximum of 1,000,000 tons per year. Facility emissions are 21.1 tons of PM10 per year, and 3.7 tons of NOx per year. The facility is limited to a maximum opacity from any processing equipment of 10 percent. The facility is subject to the applicable requirements of 40 CFR 60, Subpart Y, 40 CFR 60, Subpart IIII, and 25 Pa. Code Chapters 121—145. The permit includes emission limitations, and operational, monitoring, testing, reporting and recordkeeping requirements for the facility.

03-00246: Bedrock Mines, LP (111 Freeport Road, Pittsburgh, PA 15215) for coal mining services at the Keystone East Mine in Plumcreek Township, Armstrong County. This is an initial State-Only Operating Permit application submittal.

65-00857: Saint-Gobain Ceramics (4702 Route 982, Latrobe, PA 15650) for the manufacturing of advanced ceramic materials for wear and corrosion resistant application located in Derry Township, Westmoreland County. Saint-Gobain operates four natural gas and one electric drying kilns, mixing, and machining operations. Emissions are controlled through the use dry filter units and two afterburners/high temperature retention systems. This facility has the potential to emit 4.01 tpy NOx, 2.98 tpy VOC, 10.58 tpy CO, 1.10 tpy SOx, 2.96 tpy PM10, and 3.08 tpy HAPs. The company reported actual emissions for 2014 as: 3.55 tpy NOx, 0.66 tpy VOC, 6.29 tpy CO, 0.32 tpy SOx, and 1.01 tpy PM10. This facility is subject to the applicable requirements of 25 Pa. Code Chapters 121—145. Proposed SOOP includes conditions relating to applicable emission restrictions, testing, monitoring, recordkeeping, reporting and work practice standards requirements.

32-00433: Sunoco Pipeline, LP (525 Fritztown Road, Sinking Spring, PA 19608) In accordance with 25 Pa. Code §§ 127.424 and 127.425, notice is hereby given that Pennsylvania Department of Environmental Protection (DEP) intends to issue an Air Quality State Only Operating Permit (SOOP) to Sunoco Pipeline, LP to authorize the operation of a natural gas liquid pumping facility known as the Blairsville Station, located in Burrell Township, Indiana County.

 Sunoco Pipeline, LP operates the Blairsville Station to transport natural gas liquids consisting of ethane, propane and butane through the Mariner East II pipeline. Sources at this facility consist of an electric pump and an enclosed flare. This facility has the potential to emit less than 0.2 ton of carbon monoxide (CO), 1.3 ton of nitrogen oxides (NOx), 1.0 ton volatile organic compounds (VOCs) and 70 tons of greenhouse gas equivalents (CO2e) on a 12-month rolling basis. This facility is subject to the applicable requirements of 25 Pa. Code Chapters 121—145. The proposed SOOP includes conditions relating to applicable monitoring, recordkeeping, reporting and management practice requirements.