Annex A
TITLE 25. ENVIRONMENTAL PROTECTION
PART I. DEPARTMENT OF ENVIRONMENTAL PROTECTION
Subpart C. PROTECTION OF NATURAL RESOURCES
ARTICLE II. WATER RESOURCES
CHAPTER 109. SAFE DRINKING WATER
Subchapter A. GENERAL PROVISIONS § 109.1. Definitions.
The following words and terms, when used in this chapter, have the following meanings, unless the context clearly indicates otherwise:
* * * * * Consecutive water system—A public water system which obtains all of its water from another public water system and resells the water to a person, provides treatment to meet a primary MCL, MRDL or treatment technique, or provides drinking water to an interstate carrier. The term does not include bottled water and bulk water systems.
* * * * *
Subchapter B. MCLs, MRDLs OR TREATMENT TECHNIQUE REQUIREMENTS § 109.202. State MCLs, MRDLs and treatment technique requirements.
(a) Primary MCLs, MRDLs and treatment technique requirements.
(1) A public water system shall supply drinking water that complies with the primary MCLs, MRDLs and treatment technique requirements adopted by the EQB under the act.
(2) This subchapter incorporates by reference the primary MCLs, MRDLs and treatment technique requirements in the National Primary Drinking Water Regulations 40 CFR Part 141 (relating to National Primary Drinking Water Regulations) as State MCLs, MRDLs and treatment technique requirements under authority of section 4 of the act (35 P.S. § 721.4), unless other MCLs, MRDLs and treatment technique requirements are established by regulations of the Department. The primary MCLs, MRDLs and treatment technique requirements which are incorporated by reference are effective on the date established by the Federal regulations.
(3) A public water system that is installing granular activated carbon or membrane technology to comply with the MCL for TTHMs, HAA5, chlorite (where applicable) or bromate (where applicable) may apply to the Department for an extension of up to 24 months past the applicable compliance date specified in the Federal regulations, but not beyond December 31, 2003. In granting the extension, the Department will set a schedule for compliance and may specify any interim measures that the Department deems necessary. Failure to meet the schedule or interim treatment requirements constitutes a violation of National Primary Drinking Water Regulations.
(b) Secondary MCLs.
(1) A public water system shall supply drinking water that complies with the secondary MCLs adopted by the EQB under the act, except for the MCL for pH which represents a reasonable goal for drinking water quality.
(2) This subchapter incorporates by reference the secondary MCLs established by the EPA in the National Secondary Drinking Water Regulations, 40 CFR 143.3 (relating to secondary maximum contaminant levels), as of January 30, 1991, as State MCLs, under the authority of section 4 of the act, unless other MCLs are established by regulations of the Department. The secondary MCL for copper is not incorporated by reference.
(3) A secondary MCL for aluminum of 0.2 mg/L is adopted as a State MCL.
(c) Treatment technique requirements for pathogenic bacteria, viruses and protozoan cysts. A public water system shall provide adequate treatment to reliably protect users from the adverse health effects of microbiological contaminants, including pathogenic bacteria, viruses and protozoan cysts. The number and type of treatment barriers and the efficacy of treatment provided shall be commensurate with the type, degree and likelihood of contamination in the source water.
(1) A public water supplier shall provide, as a minimum, continuous filtration and disinfection for surface water and GUDI sources. The treatment technique must provide at least 99.9% removal and inactivation of Giardia lamblia cysts, and at least 99.99% removal and inactivation of enteric viruses. Beginning January 1, 2002, public water suppliers serving 10,000 or more people shall provide at least 99% removal of Cryptosporidium oocysts. Beginning January 1, 2005, public water suppliers serving fewer than 10,000 people shall provide at least 99% removal of Cryptosporidium oocysts. The Department, depending on source water quality conditions, may require additional treatment as necessary to meet the requirements of this chapter and to protect the public health.
(i) The filtration process shall meet the following performance requirements:
(A) Conventional or direct filtration.
(I) The filtered water turbidity shall be less than or equal to .5 NTU in 95% of the measurements taken each month under § 109.301(1) (relating to general monitoring requirements).
(II) The filtered water turbidity shall be less than or equal to 2.0 NTU at all times, measured under § 109.301(1).
(III) Beginning January 1, 2002, for public water systems serving 10,000 or more persons, the filtered water turbidity shall meet the following criteria:
(-a-) Be less than or equal to 0.3 NTU in at least 95% of the measurements taken each month under § 109.301(1).
(-b-) Be less than or equal to 1 NTU at all times, measured under § 109.301(1).
(IV) Beginning January 1, 2005, for public water systems serving fewer than 10,000 persons, the filtered water turbidity shall meet the following criteria:
(-a-) Be less than or equal to 0.3 NTU in at least 95% of the measurements taken each month under § 109.301(1).
(-b-) Be less than or equal to 1 NTU at all times, measured under § 109.301(1).
(B) Slow sand or diatomaceous earth filtration.
(I) The filtered water turbidity shall be less than or equal to 1.0 NTU in 95% of the measurements taken each month under § 109.301(1).
(II) The filtered water turbidity shall be less than or equal to 2.0 NTU at all times, measured under § 109.301(1).
(C) Other filtration technologies. The same performance criteria as those given for conventional filtration and direct filtration in clause (A) shall be achieved unless the Department specifies more stringent performance criteria based upon onsite studies, including pilot plant studies, where appropriate.
(ii) The combined total effect of disinfection processes utilized in a filtration plant shall:
(A) Achieve at least 1.0-log inactivation of Giardia cysts and 3.0-log inactivation of viruses as demonstrated by measurements taken under § 109.301(1). Failure to maintain the minimum log inactivation for more than 4 hours of operation constitutes a breakdown in treatment.
(B) Provide a minimum residual disinfectant concentration of 0.20 mg/L at the entry point as demonstrated by measurements taken under § 109.301(1). Failure to maintain the minimum entry point residual disinfectant concentration for more than 4 hours of operation is a treatment technique violation.
(iii) For an unfiltered surface water source permitted for use prior to March 25, 1989, the public water supplier shall:
(A) Maintain a minimum residual disinfectant concentration in the water delivered to the distribution system prior to the first customer of 2.5 mg/L expressed as free chlorine or its equivalent as approved by the Department. The residual disinfectant concentration shall be demonstrated by measurements taken under § 109.301(2).
(I) For a system using disinfectants other than free chlorine, the water supplier shall maintain:
(-a-) A minimum concentration that provides, in terms of CTs achieved, a level of protection equivalent to that provided by 2.5 mg/L free chlorine, as determined by the available contact time between the point of application and the first customer, under peak flow conditions.
(-b-) At least .2 mg/L of disinfectant in the water delivered to the distribution system prior to the first customer.
(II) For a system with extended contact times, generally 60 minutes or more, between the point of application and the first customer, the Department may allow the water supplier to maintain a disinfectant residual concentration less than 2.5 mg/L free chlorine or its equivalent if the CTs established by the EPA are achieved.
(B) Provide continuous filtration and disinfection in accordance with this paragraph according to the following schedule:
(I) By December 31, 1991, for a public water system that, prior to March 25, 1989, had a waterborne disease outbreak or Giardia contamination in its surface water source.
(II) Within 48 months after the discovery of one of the following conditions, or by December 31, 1995, whichever is earlier, for a public water system that experiences the condition after March 25, 1989:
(-a-) A waterborne disease outbreak.
(-b-) Giardia contamination in its surface water source.
(-c-) A violation of the microbiological MCL, the turbidity MCL or the monitoring or reporting requirements for the microbiological MCL.
(-d-) A violation of the source microbiological or turbidity monitoring requirements under § 109.301(2)(i)(A) and (B) or the related reporting requirements.
(-e-) The source water fecal coliform concentration exceeds 20/100 ml or the total coliform concentration exceeds 100/100 ml in a source water sample collected under § 109.301(2).
(-f-) The source water turbidity level exceeds 5.0 NTU in a sample collected under § 109.301(2).
(-g-) The system fails to maintain a continuous residual disinfectant concentration as required under this subparagraph.
(III) By December 31, 1995, for other public water systems not covered by subclause (I) or (II).
(iv) For an unfiltered surface water source which is subject to subparagraph (iii)(B)(II) and (III), the public water supplier shall:
(A) Submit to the Department for approval a feasibility study which specifies the means by which the supplier shall, by the applicable deadline established in subparagraph (iii)(B), meet the requirements of this paragraph. The study shall identify the alternative which best assures the long-term viability of the public water system to meet drinking water standards. The study shall propose a schedule for completion of work, including the design, financing, construction and operation of one of the following alternatives:
(I) Permanent filtration treatment facilities that meet the requirements of this chapter.
(II) Abandonment of the unfiltered surface water source and one of the following:
(-a-) Permanent interconnection with another water supply which meets the requirements of this chapter.
(-b-) Permanent water treatment facilities, utilizing groundwater as the source of supply, which meet the requirements of this chapter.
(-c-) Provision for adequate supply from existing sources which meets the requirements of this chapter.
(B) Submit the feasibility study according to the following schedule:
(I) By March 31, 1992, for a supplier which prior to August 31, 1991, experienced a triggering event as specified in subparagraph (iii)(B)(II).
(II) By June 30, 1992, for a supplier which after August 31, 1991, but before January 1, 1992, experienced a triggering event as specified in subparagraph (iii)(B)(II).
(III) By August 31, 1992, for other suppliers.
(C) Submit a full and complete permit application for the means identified in the approved feasibility study by which the supplier shall meet the requirements of this paragraph, according to the following schedule:
(I) By the date set in the approved feasibility study for a supplier which, prior to January 1, 1992, experienced a triggering event as specified in subparagraph (iii)(B)(II).
(II) By June 30, 1993, for a supplier subject to the requirements of subparagraph (iii)(B)(III), except that a public water supplier serving fewer than 3,300 people may submit its permit application by December 31, 1993.
(D) Initiate construction of the means identified in the approved feasibility study by which the supplier shall meet the requirements of this paragraph, according to the following schedule:
(I) By the date set in the approved feasibility study for a supplier which, prior to January 1, 1992, experienced a triggering event as specified in subparagraph (iii)(B)(II).
(II) By June 30, 1994, for a supplier subject to the requirements of subparagraph (iii)(B)(III), except that a public water supplier serving fewer than 3,300 people may initiate construction by December 31, 1994.
(E) Complete construction and commence operation of the alternative identified in the approved feasibility study by the dates specified in subparagraph (iii)(B).
(v) The requirements of subparagraph (iv) do not modify, repeal, suspend, supersede or otherwise change the terms of a compliance schedule or deadline, established by an existing compliance order, consent order and agreement, consent adjudication, court order or consent decree. For purposes of this paragraph, the term ''existing'' means a compliance order, consent order and agreement, consent adjudication, court order or consent decree which was issued or dated before December 14, 1991.
(vi) For a source including springs, infiltration galleries, cribs or wells permitted for use by the Department prior to May 16, 1992, and determined by the Department to be a GUDI source, the public water supplier shall:
(A) Maintain a minimum residual disinfectant concentration in the water delivered to the distribution system prior to the first customer in accordance with subparagraph (iii)(A).
(B) Provide continuous filtration and disinfection in accordance with this paragraph within 48 months after the Department determines the source of supply is a GUDI source.
(C) Submit to the Department for approval a feasibility study within 1 year after the Department determines the source of supply is a GUDI source. The feasibility study shall specify the means by which the supplier shall, within the deadline established in clause (B), meet the requirements of this paragraph and shall otherwise comply with subparagraph (iv)(A).
(2) In addition to meeting the requirements of paragraph (1), a public water supplier using surface water or GUDI sources shall also comply with the requirements of, and on the schedules in, Subchapter L (relating to long-term 2 enhanced surface water treatment rule).
(3) A community public water system shall provide continuous disinfection and comply with Subchapter M (relating to additional requirements for groundwater sources) for groundwater sources.
(4) Public water systems shall conduct assessments in accordance with § 109.705(b) (relating to system evaluations and assessments) after meeting any of the triggers under subparagraph (i) or (ii). Failure to conduct an assessment or complete a corrective action in accordance with § 109.705(b) is a treatment technique violation requiring 1-hour reporting in accordance with § 109.701(a)(3) (relating to reporting and recordkeeping) and public notification in accordance with § 109.409 (relating to Tier 2 public notice—categories, timing and delivery of notice).
(i) A Level 1 assessment is triggered if any of the following conditions occur:
(A) For systems taking 40 samples or more per month under § 109.301(3), the system exceeds 5.0% total coliform-positive samples for the month.
(B) For systems taking fewer than 40 samples per month under § 109.301(3), the system has two or more total coliform-positive samples in the same month.
(C) The system fails to take every required check sample under § 109.301(3) after any single total coliform-positive sample.
(ii) A Level 2 assessment is triggered if any of the following conditions occur:
(A) A system fails to meet the E. coli MCL as specified under subsection (a)(2).
(B) A system triggers another Level 1 assessment, as defined in subparagraph (i), within a rolling 12-month period, unless the Department has determined a likely reason that the samples that caused the first Level 1 assessment were total coliform-positive and has established that the system has corrected the problem.
(5) Failure by a seasonal water system to complete the approved start-up procedure prior to serving water to the public as required under § 109.715 (relating to seasonal systems) is a treatment technique violation requiring 1-hour reporting in accordance with § 109.701(a)(3) and public notification in accordance with § 109.409.
(6) Community water systems using a chemical disinfectant or that deliver water that has been treated with a chemical disinfectant shall comply with the minimum residual disinfectant concentration specified in § 109.710 (relating to disinfectant residual in the distribution system).
(7) Nontransient noncommunity water systems that have installed chemical disinfection and transient noncommunity water systems that have installed chemical disinfection in accordance with paragraph (1) or § 109.1302(b) (relating to treatment technique requirements) shall comply with the minimum residual disinfectant concentration specified in § 109.710.
(d) Fluoride. A public water system shall comply with the primary MCL for fluoride of 2 mg/L, except that a noncommunity water system implementing a fluoridation program approved by the Department of Health and using fluoridation facilities approved by the Department under § 109.505 (relating to requirements for noncommunity water systems) may exceed the MCL for fluoride but may not exceed the fluoride level approved by the Department of Health. The secondary MCL for fluoride of 2 mg/L established by the EPA under 40 CFR 143.3 is not incorporated into this chapter.
(e) Treatment technique requirements for acrylamide and epichlorohydrin. Systems which use acrylamide or epichlorohydrin in the water treatment process shall certify in accordance with § 109.701(d)(7) that the following specified levels have not been exceeded:
(1) Acrylamide = 0.05% dosed at 1 ppm (or equivalent).
(2) Epichlorohydrin = 0.01% dosed at 20 ppm (or equivalent).
(f) MRDLs.
(1) A public water system shall supply drinking water that complies with the MRDLs adopted by the EQB under the act.
(2) This subchapter incorporates by reference the primary MRDLs in the National Primary Drinking Water Regulations, in 40 CFR Part 141, Subpart G (relating to National Primary Drinking Water Regulations: maximum contaminant levels and maximum residual disinfectant levels) as State MRDLs, under the authority of section 4 of the act, unless other MRDLs are established by regulations of the Department. The primary MRDLs which are incorporated by reference are effective on the date established by the Federal regulations.
(g) Treatment technique requirements for disinfection byproduct precursors. Community water systems and nontransient noncommunity water systems that use either surface water or GUDI sources and that use conventional filtration treatment shall provide adequate treatment to reliably control disinfection byproduct precursors in the source water. Enhanced coagulation and enhanced softening are deemed by the Department to be treatment techniques for the control of disinfection byproduct precursors in drinking water treatment and distribution systems. This subchapter incorporates by reference the treatment technique in 40 CFR 141.135 (relating to treatment technique for control of disinfection byproduct (DBP) precursors). Coagulants approved by the Department are deemed to be acceptable for the purpose of this treatment technique. This treatment technique is effective on the date established by the Federal regulations.
(h) Recycling of waste stream.
(1) Except as provided in paragraph (2), a public water system that uses surface water source or GUDI and provides conventional filtration or direct filtration treatment and recycles spent filter backwash water, thickener supernatant, or liquids from dewatering processes shall return these recycled flows through the processes of the system's existing conventional or direct filtration system as defined in § 109.1 (relating to definitions) or at an alternate location approved by the Department by June 8, 2004.
(2) If capital improvements are required to modify the recycle location to meet the requirement of paragraph (1), the capital improvements shall be completed by June 8, 2006.
(3) Capital improvement means a nonrecurring, significant modification for nonroutine, long-term physical improvements to any part of a public water system, including, but not limited to, construction activities, renovation activities, demolition activities, source development, treatment process modifications, storage modifications, distribution system modifications, waste-processing modifications and all associated design costs.
Subchapter C. MONITORING REQUIREMENTS § 109.301. General monitoring requirements.
Public water suppliers shall monitor for compliance with MCLs, MRDLs and treatment technique requirements in accordance with the requirements established by the EPA under the National Primary Drinking Water Regulations, 40 CFR Part 141 (relating to National Primary Drinking Water Regulations), except as otherwise established by this chapter unless increased monitoring is required by the Department under § 109.302 (relating to special monitoring requirements). Alternative monitoring requirements may be established by the Department and may be implemented in lieu of monitoring requirements for a particular National Primary Drinking Water Regulation if the alternative monitoring requirements are in conformance with the Federal act and regulations. The monitoring requirements shall be applied as follows:
(1) Performance monitoring for filtration and disinfection. A public water supplier providing filtration and disinfection of surface water or GUDI sources shall conduct the following performance monitoring requirements, unless increased monitoring is required by the Department under § 109.302.
(i) Except as provided under subparagraphs (ii) and (iii) a public water supplier:
(A) Shall determine and record the turbidity level of representative samples of the system's filtered water as follows:
(I) For systems that operate continuously, at least once every 4 hours that the system is in operation, except as provided in clause (B).
(II) For systems that do not operate continuously, at start-up, at least once every 4 hours that the system is in operation, and also prior to shutting down the plant, except as provided in clause (B).
(B) May substitute continuous turbidity monitoring and recording for grab sample monitoring and manual recording if it validates the continuous measurement for accuracy on a regular basis using a procedure specified by the manufacturer. At a minimum, calibration with an EPA-approved primary standard shall be conducted at least quarterly. For systems using slow sand filtration or filtration treatment other than conventional filtration, direct filtration or diatomaceous earth filtration, the Department may reduce the sampling frequency to once per day.
(C) Shall continuously monitor and record the residual disinfectant concentration of the water being supplied to the distribution system and record both the lowest value for each day and the number of periods each day when the value is less than 0.20 mg/L for more than 4 hours. If a public water system's continuous monitoring or recording equipment fails, the public water supplier may, upon notification of the Department under § 109.701(a)(3) (relating to reporting and recordkeeping), substitute grab sampling or manual recording every 4 hours in lieu of continuous monitoring. Grab sampling or manual recording may not be substituted for continuous monitoring or recording for longer than 5 working days after the equipment fails.
(D) Until April 28, 2019, shall measure and record the residual disinfectant concentration at representative points in the distribution system no less frequently than the frequency required for total coliform sampling for compliance with the MCL for microbiological contaminants.
(E) Beginning April 29, 2019, shall measure and record the residual disinfectant concentration at representative points in the distribution system in accordance with a sample siting plan as specified in § 109.701(a)(8) and as follows:
(I) A public water supplier shall monitor the residual disinfectant concentration at the same time and from the same location that a total coliform sample is collected as specified in paragraph (3)(i) and (ii). Measurements taken under this subclause may be used to meet the requirements under subclause (II).
(II) A public water supplier shall monitor the residual disinfectant concentration at representative locations in the distribution system at least once per week.
(III) A public water supplier that does not maintain the minimum residual disinfectant concentration specified in § 109.710 (relating to disinfectant residual in the distribution system) at one or more sample sites shall include those sample sites in the monitoring conducted the following month.
(IV) Compliance with the minimum residual disinfectant concentration shall be determined in accordance with § 109.710.
(V) A public water system may substitute online residual disinfectant concentration monitoring and recording for grab sample monitoring and manual recording if it validates the online measurement for accuracy in accordance with § 109.304 (relating to analytical requirements).
(ii) For a public water supplier serving 3,300 or fewer people, the Department may reduce the residual disinfectant concentration monitoring for the water being supplied to the distribution system to a minimum of 2 hours between samples at the grab sampling frequencies prescribed as follows if the historical performance and operation of the system indicate the system can meet the residual disinfectant concentration at all times:
System Size (People) Samples/Day <500 1 500—1,000 2 1,001—2,500 3 2,501—3,300 4 If the Department reduces the monitoring, the supplier shall nevertheless collect and analyze another residual disinfectant measurement as soon as possible, but no longer than 4 hours from any measurement which is less than .2 mg/L.
(iii) For a public water supplier serving fewer than 500 people, the Department may reduce the filtered water turbidity monitoring to one grab sample per day, if the historical performance and operation of the system indicate effective turbidity removal is maintained under the range of conditions expected to occur in the system's source water.
(iv) A public water supplier providing conventional filtration treatment or direct filtration and serving 10,000 or more people and using surface water or GUDI sources shall, beginning January 1, 2002, conduct continuous monitoring of turbidity for each individual filter using an approved method under the EPA regulation in 40 CFR 141.74(a) (relating to analytical and monitoring requirements) and record the results at least every 15 minutes. Beginning January 1, 2005, public water suppliers providing conventional or direct filtration and serving fewer than 10,000 people and using surface water or GUDI sources shall conduct continuous monitoring of turbidity for each individual filter using an approved method under the EPA regulation in 40 CFR 141.74(a) and record the results at least every 15 minutes.
(A) The water supplier shall calibrate turbidimeters using the procedure specified by the manufacturer. At a minimum, calibration with an EPA-approved primary standard shall be conducted at least quarterly.
(B) If there is failure in the continuous turbidity monitoring or recording equipment, or both, the system shall conduct grab sampling or manual recording, or both, every 4 hours in lieu of continuous monitoring or recording.
(C) A public water supplier serving 10,000 or more persons has a maximum of 5 working days following the failure of the equipment to repair or replace the equipment before a violation is incurred.
(D) A public water supplier serving fewer than 10,000 persons has a maximum of 14 days following the failure of the equipment to repair or replace the equipment before a violation is incurred.
(v) A public water supplier shall calculate the log inactivation of Giardia, using measurement methods established by the EPA, at least once per day during expected peak hourly flow. The log inactivation for Giardia must also be calculated whenever the residual disinfectant concentration at the entry point falls below the minimum value specified in § 109.202(c) (relating to State MCLs, MRDLs and treatment technique requirements) and continue to be calculated every 4 hours until the residual disinfectant concentration at the entry point is at or above the minimum value specified in § 109.202(c). Records of log inactivation calculations must be reported to the Department in accordance with § 109.701(a)(2).
(vi) In addition to the requirements specified in subparagraph (v), a public water supplier that uses a disinfectant other than chlorine to achieve log inactivation shall calculate the log inactivation of viruses at least once per day during expected peak hourly flow. The log inactivation for viruses shall also be calculated whenever the residual disinfectant concentration at the entry point falls below the minimum value specified in § 109.202(c) and continue to be calculated every 4 hours until the residual disinfectant concentration at the entry point is at or above the minimum value specified in § 109.202(c). Records of log inactivation calculations shall be reported to the Department in accordance with § 109.701(a).
(2) Performance monitoring for unfiltered surface water and GUDI. A public water supplier using unfiltered surface water or GUDI sources shall conduct the following source water and performance monitoring requirements on an interim basis until filtration is provided, unless increased monitoring is required by the Department under § 109.302:
(i) Except as provided under subparagraphs (ii) and (iii), a public water supplier:
(A) Shall perform E. coli or total coliform density determinations on samples of the source water immediately prior to disinfection. Regardless of source water turbidity, the minimum frequency of sampling for total coliform or E. coli determinations may be no less than the following:
System Size (People) Samples/Week <500 1 500—3,299 2 3,300—10,000 3 10,001—25,000 4 25,001 or more 5 (B) Shall measure the turbidity of a representative grab sample of the source water immediately prior to disinfection as follows:
(I) For systems that operate continuously, at least once every 4 hours that the system is in operation, except as provided in clause (C).
(II) For systems that do not operate continuously, at start-up, at least once every 4 hours that the system is in operation, and also prior to shutting down the plant, except as provided in clause (C).
(C) May substitute continuous turbidity monitoring for grab sample monitoring if it validates the continuous measurement for accuracy on a regular basis using a procedure specified by the manufacturer. At a minimum, calibration with an EPA-approved primary standard shall be conducted at least quarterly.
(D) Shall continuously monitor and record the residual disinfectant concentration required under § 109.202(c)(1)(iii)of the water being supplied to the distribution system and record the lowest value for each day. If a public water system's continuous monitoring or recording equipment fails, the public water supplier may, upon notification of the Department under § 109.701(a)(3), substitute grab sampling or manual recording, or both, every 4 hours in lieu of continuous monitoring. Grab sampling or manual recording may not be substituted for continuous monitoring for longer than 5 days after the equipment fails.
(E) Until April 28, 2019, shall measure the residual disinfectant concentration at representative points in the distribution system no less frequently than the frequency required for total coliform sampling for compliance with the MCL for microbiological contaminants.
(F) Beginning April 29, 2019, shall measure and record the residual disinfectant concentration at representative points in the distribution system in accordance with a sample siting plan as specified in § 109.701(a)(8) and as follows:
(I) A public water supplier shall monitor the residual disinfectant concentration at the same time and from the same location that a total coliform sample is collected as specified in paragraph (3)(i) and (ii). Measurements taken under this subclause may be used to meet the requirements under subclause (II).
(II) A public water supplier shall monitor the residual disinfectant concentration at representative locations in the distribution system at least once per week.
(III) A public water supplier that does not maintain the minimum residual disinfectant concentration specified in § 109.710 at one or more sample sites shall include those sample sites in the monitoring conducted the following month.
(IV) Compliance with the minimum residual disinfectant concentration shall be determined in accordance with § 109.710.
(V) A public water system may substitute online residual disinfectant concentration monitoring and recording for grab sample monitoring and manual recording if it validates the online measurement for accuracy in accordance with § 109.304.
(ii) For a public water supplier serving 3,300 or fewer people, the Department may reduce the residual disinfectant concentration monitoring for the water being supplied to the distribution system to a minimum of 2 hours between samples at the grab sampling frequencies prescribed as follows if the historical performance and operation of the system indicate the system can meet the residual disinfectant concentration at all times:
* * * * * (5) Monitoring requirements for VOCs. Community water systems and nontransient noncommunity water systems shall monitor for compliance with the MCLs for VOCs established by the EPA under 40 CFR 141.61(a) (relating to maximum contaminant levels for organic contaminants). The monitoring shall be conducted according to the requirements established by the EPA under 40 CFR 141.24(f) (relating to organic chemicals, sampling and analytical requirements), incorporated herein by reference, except as modified by this chapter. Initial or first year monitoring mentioned in this paragraph refers to VOC monitoring conducted on or after January 1, 1993.
(i) Vinyl chloride. Monitoring for compliance with the MCL for vinyl chloride is required for groundwater entry points at which one or more of the following two-carbon organic compounds have been detected: trichloroethylene, tetrachloroethylene, 1,2-dichloroethane, 1,1,1-trichloro-ethane, cis-1,2-dichloroethylene, trans-1,2-dichloro-ethylene or 1,1-dichloroethylene and shall consist of quarterly samples. If the results of the first analysis do not detect vinyl chloride, monitoring shall be reduced to one sample during each compliance period. Surface water entry points shall monitor for vinyl chloride as specified by the Department.
(ii) Initial monitoring. Initial monitoring shall consist of 4 consecutive quarterly samples at each entry point in accordance with the following monitoring schedule during the compliance period beginning January 1, 1993, except for systems which are granted reduced initial monitoring in accordance with clauses (E) and (F). A system which monitors during the initial monitoring period, but begins monitoring before its scheduled initial monitoring year specified in this subparagraph, shall begin monitoring every entry point during the first calendar quarter of the year it begins monitoring, except as provided in clause (E).
(A) Systems serving more than 10,000 persons shall begin monitoring during the quarter beginning January 1, 1994.
(B) Systems serving 3,301 persons to 10,000 persons shall begin monitoring during the quarter beginning January 1, 1995.
(C) Systems serving 500 to 3,300 persons shall begin monitoring during the quarter beginning January 1, 1993.
(D) Systems serving fewer than 500 persons shall begin monitoring during the quarter beginning January 1, 1994.
(E) For systems serving 3,300 or fewer people which monitor at least one quarter prior to October 1, 1993, and do not detect VOCs at an entry point during the first quarterly sample, the required initial monitoring is reduced to one sample at that entry point. For systems serving 500 to 3,300 people to qualify for this reduced monitoring, the initial monitoring shall have been conducted during the quarter beginning January 1, 1993.
(F) For systems serving more than 3,300 people, which were in existence prior to January 1, 1993, initial monitoring for compliance with the MCLs for VOCs established by the EPA under 40 CFR 141.61(a) is reduced to one sample for each entry point which meets the following conditions:
(I) VOC monitoring required by the Department between January 1, 1988, and December 31, 1992, has been conducted and no VOCs regulated under 40 CFR 141.61(a) were detected.
(II) The first quarter monitoring required by this paragraph has been conducted during the first quarter of the system's scheduled monitoring year under this paragraph, with no detection of a VOC.
(G) Systems with new entry points associated with new sources which are permitted under Subchapter E (relating to permit requirements) to begin operation after December 31, 1992, shall conduct initial monitoring as follows. New entry points shall be monitored quarterly, beginning the first full quarter the entry point begins serving the public.
(iii) Repeat monitoring for entry points at which a VOC is detected. For entry points at which a VOC is detected at a level equal to or greater than 0.0005 mg/L, then:
(A) Monitoring shall be repeated quarterly beginning the quarter following the detection for VOCs for which the EPA has established MCLs under 40 CFR 141.61(a), except for vinyl chloride as provided in subparagraph (i), until reduced monitoring is granted in accordance with this subparagraph.
(B) The Department may decrease the quarterly monitoring requirement specified in clause (A) provided it has determined that the system is reliably and consistently below the MCL. For an initial detection of a VOC, the Department will not make this determination until the water system obtains results from a minimum of four consecutive quarterly samples that are reliably and consistently below the MCL.
* * * * * (6) Monitoring requirements for SOCs (pesticides and PCBs). Community water systems and nontransient noncommunity water systems shall monitor for compliance with the MCLs for SOCs established by the EPA under 40 CFR 141.61(c). The monitoring shall be conducted according to the requirements established by the EPA under 40 CFR 141.24(h), incorporated herein by reference except as modified by this chapter.
(i) Initial monitoring. Initial monitoring shall consist of 4 consecutive quarterly samples at each entry point beginning during the quarter beginning January 1, 1995, except for systems which are granted an initial monitoring waiver in accordance with subparagraph (vii). Systems which monitor during the initial monitoring period but begin monitoring before 1995 shall begin monitoring during the first calendar quarter of the year. New entry points associated with new sources which are vulnerable to SOC contamination, as determined in accordance with subparagraph (vii), and which begin operation after March 31, 1995, shall be monitored quarterly, beginning the first full quarter the entry point begins serving the public.
(ii) Repeat monitoring for SOCs that are detected. If an SOC is detected (as defined by the EPA under 40 CFR 141.24(h)(18) or by the Department), then:
(A) Monitoring for the detected SOC shall be conducted quarterly, beginning the quarter following the detection, until reduced monitoring is granted in accordance with this subparagraph.
(B) The Department may decrease the quarterly monitoring requirement specified in clause (A) provided it has determined that the system is reliably and consistently below the MCL. For an initial detection of a SOC, the Department will not make this determination until the water system obtains results from a minimum of four consecutive quarterly samples that are reliably and consistently below the MCL.
(C) If the Department determines that the system is reliably and consistently below the MCL, the Department may allow the system to monitor annually. Systems which monitor annually shall monitor during the quarter that previously yielded the highest analytical result, or as specified by the Department.
(D) Systems which have 3 consecutive years of quarterly or annual samples with no detection of a contaminant may apply to the Department for a waiver as specified in subparagraph (vii). A waiver is effective for one compliance period and may be renewed in each subsequent compliance period.
(E) For entry points at which either heptachlor or heptachlor epoxide is detected during the initial round of consecutive quarterly samples, or in subsequent repeat samples, the monitoring shall be continued for both contaminants in accordance with the more frequent monitoring required of the two contaminants based on the level at which each is detected.
(iii) Repeat monitoring for SOCs that are not detected. For entry points at which SOCs are not detected during the first year of quarterly monitoring, the required monitoring is reduced to one sample in each 3-year compliance period for systems serving 3,300 or fewer persons and to 2 consecutive quarterly samples in each compliance period for systems serving more than 3,300 persons. Reduced monitoring shall be conducted at 3-year intervals from the year of required initial VOC monitoring, in accordance with paragraph (5)(ii).
(iv) Repeat monitoring for SOCs with MCL exceedances. For entry points at which an SOC MCL is exceeded, monitoring for the detected SOC shall be conducted quarterly, beginning the quarter following the exceedance. Quarterly monitoring shall continue until a minimum of 4 consecutive quarterly samples shows the system is in compliance as specified in subparagraph (ix) and the Department determines the system is reliably and consistently below the MCL. If the Department determines that the system is in compliance and is reliably and consistently below the MCL, the Department may allow the system to monitor in accordance with subparagraph (ii)(C).
(v) Confirmation samples. A confirmation sample shall be collected and analyzed for each SOC listed under 40 CFR 141.61(c) which is detected at a level in excess of its MCL during annual or less frequent compliance monitoring. The confirmation sample shall be collected within 2 weeks of the water supplier receiving notification from the accredited laboratory performing the analysis that an MCL has been exceeded. The average of the results of the original and the confirmation samples will be used to determine compliance. Confirmation monitoring shall be completed by the deadline specified for SOC compliance monitoring.
(vi) Reduced monitoring. When reduced monitoring is provided under subparagraph (ii) or (iii), the system shall monitor the entry point during the second calendar year quarter, or the second and third calendar year quarter when 2 quarterly samples are required in each compliance period, unless otherwise specified by the Department. The reduced monitoring option in subparagraph (iii) does not apply to entry points at which treatment has been installed for SOC removal. Compliance monitoring for SOCs for which treatment has been installed to comply with an MCL shall be conducted at least annually, and performance monitoring shall be conducted quarterly.
(vii) Waivers. A waiver will be granted to a public water supplier from conducting the initial compliance monitoring or repeat monitoring, or both, for an SOC based on documentation provided by the public water supplier and a determination by the Department that the criteria in clause (B), (C) or (D) has been met. A waiver is effective for one compliance period and may be renewed in each subsequent compliance period. If the Department has not granted a use waiver in accordance with clause (B), the public water supplier is responsible for submitting a waiver application and renewal application to the Department for review in accordance with clause (B), (C) or (D) for specific entry points. Waiver applications will be evaluated relative to the vulnerability assessment area described in clause (A) and the criteria in clause (B), (C) or (D). Entry points at which treatment has been installed to remove an SOC are not eligible for a monitoring waiver for the SOCs for which treatment has been installed.
(A) Vulnerability assessment area for SOCs including dioxin and PCBs.
(I) For groundwater or GUDI entry points, the vulnerability assessment area shall consist of wellhead protection area Zones I and II.
(II) For surface water entry points, the vulnerability assessment area shall consist of the area that supplies water to the entry point and is separated from other watersheds by the highest topographic contour.
(B) Use waivers. A use waiver will be granted by the Department for contaminants which the Department has determined have not been used, stored, manufactured, transported or disposed of in this Commonwealth, or portions of this Commonwealth. A use waiver specific to a particular entry point requires that an SOC was not used, stored, manufactured, transported or disposed of in the vulnerability assessment area. If use waiver criteria cannot be met, a public water supplier may apply for a susceptibility waiver.
(C) Susceptibility waivers. A susceptibility waiver for specific contaminants may be granted based on the following criteria, and only applies to groundwater entry points:
(I) Previous analytical results.
(II) Environmental persistence and transport of the contaminant.
(III) Proximity of the drinking water source to point or nonpoint source contamination.
(IV) Elevated nitrate levels as an indicator of the potential for pesticide contamination.
(V) Extent of source water protection or approved wellhead protection program.
(D) Waiver requests and renewals. Waiver requests and renewals shall be submitted to the Department, on forms provided by the Department, for review and approval prior to the end of the applicable monitoring period. Until the waiver request or renewal is approved, the public water system is responsible for conducting all required monitoring.
(viii) Invalidation of SOC samples.
(A) The Department may invalidate results of obvious sampling errors.
(B) An SOC sample invalidated under this subparagraph does not count towards meeting the minimum monitoring requirements of this paragraph.
(ix) Compliance determinations. Compliance with the SOC MCLs shall be determined based on the analytical results obtained at each entry point. If one entry point is in violation of an MCL, the system is in violation of the MCL.
(A) For systems monitoring more than once per year, compliance with the MCL is determined by a running annual average of all samples taken at each entry point.
(B) If monitoring is conducted annually or less frequently, the system is out of compliance if the level of a contaminant at any entry point is greater than the MCL. If a confirmation sample is collected as specified in subparagraph (v), compliance is determined using the average of the two sample results.
(C) If any sample result will cause the running annual average to exceed the MCL at any entry point, the system is out of compliance with the MCL immediately.
(D) If a system fails to collect the required number of samples, compliance with the MCL will be based on the total number of samples collected.
(E) If a sample result is less than the detection limit, zero will be used to calculate compliance.
(7) Monitoring requirements for IOCs. Community water systems and nontransient noncommunity water systems shall monitor for compliance with the MCLs for IOCs established by the EPA under 40 CFR 141.62 (relating to maximum contaminant levels for inorganic contaminants). Transient noncommunity water suppliers shall monitor for compliance with the MCLs for nitrate and nitrite. The monitoring shall be conducted according to the requirements established by the EPA under 40 CFR 141.23 (relating to inorganic chemical sampling and analytical requirements). The requirements are incorporated by reference except as modified by this chapter.
(i) Monitoring requirements for asbestos.
(A) Monitoring frequency. Community water systems and nontransient noncommunity water systems not granted a waiver under clause (F) shall monitor for compliance with the MCL for asbestos by taking one sample at each vulnerable sampling point during the first 3-year compliance period of each 9-year compliance cycle, with the initial compliance monitoring beginning not later than the calendar year beginning January 1, 1995.
(B) Sampling points. A system shall monitor at the following locations:
(I) Each entry point to the distribution system.
(II) At least one representative location within the distribution system identified in a written sample site plan that includes a materials evaluation of the distribution system. The written sample site plan shall be maintained on record and submitted to the Department prior to conducting initial monitoring or upon request.
(C) Monitoring of new entry points. New entry points which begin operation after December 31, 1995, shall conduct initial monitoring during the first compliance period of the first compliance cycle after the entry point begins serving the public, if the Department determines that a waiver cannot be granted in accordance with clause (F).
(D) Repeat monitoring for systems that exceed the asbestos MCL. If a sample exceeds the MCL for asbestos, the monitoring at that sampling point shall be continued quarterly beginning in the quarter following the MCL exceedance. After four consecutive quarterly samples with results reliably and consistently below the MCL at that entry point, the required monitoring is reduced to one sample at that entry point during the first 3-year compliance period of each subsequent 9-year compliance cycle, if treatment has not been installed to remove asbestos from the source water. Compliance monitoring at entry points at which treatment has been installed to remove asbestos from source water shall be conducted at least annually, and performance monitoring shall be conducted quarterly.
(E) Confirmation samples. For asbestos sample results in excess of the MCL during annual or less frequent compliance monitoring, the water supplier shall take a confirmation sample within 2 weeks of notification by the accredited laboratory performing the analysis. The average of the results of the original and the confirmation sample will be used to determine compliance. Monitoring shall be completed by the deadline specified for asbestos compliance monitoring.
(F) Waivers for asbestos monitoring. A waiver will be granted to a public water supplier from conducting compliance monitoring for asbestos based on documentation provided by the public water supplier and a determination by the Department that the criteria in this clause have been met. A waiver is effective for one compliance period and may be renewed in each subsequent compliance period. Entry points at which treatment has been installed to remove asbestos are not eligible for a monitoring waiver.
(I) A waiver for entry point compliance monitoring may be granted if the sources supplying the entry point are not vulnerable to asbestos contamination.
(II) A waiver for distribution system monitoring may be granted if the distribution system does not contain asbestos cement pipe as indicated in the materials evaluation or if the water system has optimized corrosion control as specified in Subchapter K (relating to lead and copper).
(III) Waiver requests and renewals shall be submitted to the Department, on forms provided by the Department, for review and approval prior to the end of the applicable monitoring period. Until the waiver request or renewal is approved, the public water system is responsible for conducting all required monitoring.
(ii) Monitoring requirements for nitrate and nitrite.
(A) Initial monitoring schedule. A public water system shall begin monitoring for nitrate and nitrite by taking one annual sample at each groundwater or GUDI entry point to the distribution system beginning during the year beginning January 1, 1993. Community water systems and nontransient noncommunity water systems with surface water sources shall monitor quarterly at each surface water entry point for nitrate and nitrite beginning during the quarter beginning January 1, 1993. Transient noncommunity water systems shall monitor each surface water entry point by taking one annual sample beginning during the year beginning January 1, 1993.
(B) Monitoring of new entry points.
(I) New community and nontransient noncommunity surface water entry points associated with new sources shall be monitored quarterly, beginning the first full quarter the entry point begins serving the public. Quarterly monitoring shall continue until reduced monitoring is granted in accordance with clause (C)(II) or (D).
(II) New community and nontransient noncommunity groundwater or GUDI entry points and new transient noncommunity entry points associated with new sources shall be monitored annually, beginning within 1 year of serving the public.
(C) Repeat monitoring for systems with nitrate or nitrite levels equal to or greater than 50% of the MCLs.
(I) For entry points at which initial monitoring results or subsequent monitoring indicate nitrate or nitrite levels equal to or greater than 50% of the MCL, water systems shall begin quarterly monitoring the quarter following detection at that level and continue quarterly monitoring for both nitrate and nitrite, unless reduced monitoring is granted in accordance with subclause (II) or (III).
(II) For surface water entry points, after 4 consecutive quarterly samples at an entry point for a water system indicate nitrate and nitrite levels in each sample are less than 50% of the MCLs, the required compliance monitoring is reduced to 1 sample per year at the entry point. Annual monitoring shall be conducted during the quarter which previously resulted in the highest analytical result, unless the Department determines that a different monitoring quarter should be used in accordance with paragraph (10).
(III) For groundwater or GUDI entry points, after 4 consecutive quarterly samples at an entry point for a water system indicate nitrate and nitrite levels in each sample are reliably and consistently below the MCL, the required compliance monitoring is reduced to 1 sample per year at the entry point. Annual monitoring shall be conducted during the quarter which previously resulted in the highest analytical result, unless the Department determines that a different monitoring quarter should be used in accordance with paragraph (10).
(IV) For nitrate or nitrite sample results in excess of the MCLs, the water supplier shall take a confirmation sample within 24 hours of having received the original sample result. A water supplier that is unable to comply with the 24-hour sampling requirement shall immediately notify persons served by the public water system in accordance with § 109.408. Systems exercising this option shall take and analyze a confirmation sample within 2 weeks of notification of the analytical results of the first sample.
(V) Noncommunity water systems for which an alternate nitrate level has been approved by the Department in accordance with 40 CFR 141.11(d) (relating to maximum contaminant levels for inorganic chemicals) are not required to collect a confirmation sample if only the nitrate MCL is exceeded and nitrate is not in excess of the alternate nitrate level. If the alternate nitrate level is exceeded, the water supplier shall collect a confirmation sample within 24 hours after being advised by the certified laboratory performing the analysis that the compliance sample exceeded 20 mg/L for nitrate. Confirmation monitoring shall be completed by the deadline for compliance monitoring.
(VI) Quarterly performance monitoring is required for nitrate and nitrite at entry points where treatment has been installed to remove nitrate or nitrite.
(D) Repeat monitoring for systems with nitrate and nitrite levels less than 50% of the MCLs. For entry points at which initial monitoring results indicate nitrate and nitrite levels in each sample are less than 50% of the MCLs, nitrate and nitrite monitoring shall be repeated annually during the calendar quarter which previously resulted in the highest analytical result, unless the Department determines that a different monitoring quarter should be used in accordance with paragraph (10).
(iii) Monitoring requirements for antimony, arsenic, barium, beryllium, cadmium, cyanide, chromium, fluoride, mercury, nickel, selenium and thallium.
(A) Initial monitoring schedule. Community water systems and nontransient noncommunity water systems shall monitor each surface water entry point annually beginning during the year beginning January 1, 1993, and shall monitor each groundwater or GUDI entry point once every 3 years beginning during the year beginning January 1, 1994.
(B) Monitoring of new entry points. New groundwater or GUDI entry points which begin operation after December 31, 1994, shall begin initial monitoring in accordance with the schedule in clause (A)—that is, 1997, and so forth. New surface water entry points shall begin initial annual monitoring during the first new calendar year after the entry point begins serving the public.
(C) Repeat monitoring for entry points at which an IOC MCL is exceeded.
(I) For entry points at which initial monitoring results or subsequent monitoring indicates an IOC level in excess of the MCL, monitoring shall be repeated quarterly beginning the quarter following detection at that level for each IOC in excess of an MCL, until reduced monitoring is granted in accordance with subclause (II).
(II) After analyses of four consecutive quarterly samples indicate that contaminant levels are reliably and consistently below the MCLs, the required monitoring at an entry point where treatment has not been installed to comply with an IOC MCL for each IOC that is reliably and consistently below the MCL is reduced to the frequencies stated in clause (A). This reduced monitoring option does not apply to entry points at which treatment has been installed for IOC removal. Compliance monitoring for IOCs for which treatment has been installed to comply with an MCL shall be conducted at least annually, and performance monitoring shall be conducted quarterly.
* * * * * (12) Monitoring requirements for disinfection byproducts and disinfection byproduct precursors. Community water systems and nontransient noncommunity water systems that use a chemical disinfectant or oxidant shall monitor for disinfection byproducts and disinfection byproduct precursors in accordance with this paragraph. Community water systems and nontransient noncommunity water systems that obtain finished water from another public water system that uses a chemical disinfectant or oxidant to treat the finished water shall monitor for TTHM and HAA5 in accordance with this paragraph. Systems that use either surface water or GUDI sources and that serve at least 10,000 persons shall begin monitoring by January 1, 2002. Systems that use either surface water or GUDI sources and that serve fewer than 10,000 persons, or systems that use groundwater sources, shall begin monitoring by January 1, 2004. Systems monitoring for disinfection byproducts and disinfection byproduct precursors shall take all samples during normal operating conditions. Systems monitoring for disinfection byproducts and disinfection byproduct precursors shall use only data collected under this chapter to qualify for reduced monitoring. Compliance with the MCLs and monitoring requirements for TTHM, HAA5, chlorite (where applicable) and bromate (where applicable) shall be determined in accordance with 40 CFR 141.132 and 141.133 (relating to monitoring requirements; and compliance requirements) which are incorporated herein by reference.
* * * * * (iv) Bromate. Community water systems and nontrans- ient noncommunity water systems that use ozone for disinfection or oxidation shall monitor for bromate.
(A) Routine monitoring. Systems shall take one sample per month for each treatment plant that uses ozone. Systems shall take the monthly sample at the entrance to the distribution system while the ozonation system is operating under normal conditions.
(B) Reduced monitoring.
(I) Until March 31, 2009, systems that have an average source water bromide concentration that is less than 0.05 mg/L based upon representative monthly bromide measurements for 1 year, the required monitoring is reduced from monthly to quarterly. Systems on reduced monitoring shall continue to take monthly samples for source water bromide. If the running annual average source water bromide concentration, computed quarterly, equals or exceeds 0.05 mg/L based upon representative monthly measurements, the system shall revert to routine monitoring as prescribed by clause (A).
(II) Beginning April 1, 2009, a system required to analyze for bromate may reduce monitoring from monthly to quarterly, if the system's running annual average bromate concentration computed quarterly is less than or equal to 0.0025 mg/L based on monthly measurements as prescribed in clause (A) analyzed using methods specified in 40 CFR 141.132(b)(3)(ii)(B) for the most recent 4 quarters. Systems qualifying for reduced bromate monitoring under subclause (I) may remain on reduced monitoring as long as the running annual average of quarterly bromate samples analyzed using methods specified in 40 CFR 141.132(b)(3)(ii)(B) is less than or equal to 0.0025 mg/L. If the running annual average bromate concentration is greater than 0.0025 mg/L, the system shall resume routine monitoring as prescribed under clause (A).
(v) DBP precursors. Community water systems and nontransient noncommunity water systems that use either surface water or GUDI sources and that use conventional filtration shall monitor for disinfection byproduct precursors.
(A) Routine monitoring. Systems shall take monthly samples of the source water alkalinity, the source water TOC and postsedimentation TOC for each treatment plant that uses conventional filtration. Postsedimentation TOC can be taken at any point between sedimentation effluent and the entry point to the distribution system. The three samples shall be taken concurrently and at a time that is representative of both normal operating conditions and influent water quality.
(B) Reduced monitoring. For systems with an average postsedimentation TOC of less than 2.0 mg/L for 2-consecutive years, or less than 1.0 mg/L for 1 year, the required monitoring for source water alkalinity, source TOC and postsedimentation TOC is reduced from monthly to quarterly for each applicable treatment plant. The system shall revert to routine monitoring as prescribed by clause (A) in the month following the quarter when the annual average postsedimentation TOC is not less than 2.0 mg/L.
(C) Early monitoring. Systems may begin monitoring to determine whether the TOC removal requirements of 40 CFR 141.135(b)(1) (relating to treatment technique for control of disinfection byproduct (DBP) precursors) can be met 12 months prior to the compliance date for the system. This monitoring is not required and failure to monitor during this period is not a violation. However, any system that does not monitor during this period, and then determines in the first 12 months after the compliance date that it is not able to meet the requirements of 40 CFR 141.135(b)(1) and shall therefore apply for alternate minimum TOC removal requirements under 40 CFR 141.135(b)(4) is not eligible for retroactive approval of the alternate minimum TOC removal requirements and is in violation. Systems may apply for alternate minimum TOC removal requirements any time after the compliance date.
(13) Monitoring requirements for disinfectant residuals. Community water systems and nontransient noncommunity water systems that use either chlorine or chloramines or that obtain finished water from another public water system that uses either chlorine or chloramines, and transient noncommunity water systems that install chemical disinfection treatment in accordance with § 109.1302(b) (relating to treatment technique requirements) shall monitor for residual disinfectant concentration in accordance with this paragraph. Community water systems, nontransient noncommunity water systems and transient noncommunity water systems that use chlorine dioxide to treat the finished water shall monitor for chlorine dioxide in accordance with this paragraph. Systems monitoring for residual disinfectant concentration shall take all samples during normal operating conditions. Compliance with the MRDLs and monitoring requirements for chlorine, chloramines and chlorine dioxide (where applicable) shall be determined in accordance with 40 CFR 141.132 and 141.133 which are incorporated herein by reference. Compliance with the minimum residual disinfectant concentration shall be determined in accordance with § 109.710.
(i) Chlorine and chloramines.
(A) Until April 28, 2019, systems shall measure the residual disinfectant level at the same points in the distribution system and at the same time that total coliforms are sampled, as specified in paragraph (3). Systems that used either surface water or GUDI sources may use the results of residual disinfectant concentration sampling conducted under paragraph (1) or (2) in lieu of taking separate samples.
(B) Beginning April 29, 2019, systems shall measure the residual disinfectant concentration in accordance with a sample siting plan as specified in § 109.701(a)(8) and as follows:
(I) Public water systems shall monitor the residual disinfectant concentration at the same time and from the same location that a total coliform sample is collected as specified in paragraph (3)(i) and (ii). Systems that use either surface water or GUDI sources may use the results of residual disinfectant concentration sampling conducted under paragraph (1) or (2) instead of taking separate samples. Measurements taken under this clause may be used to meet the requirements under subclause (II).
(II) Public water systems shall monitor the residual disinfectant concentration at representative locations in the distribution system at least once per week.
(III) A public water system that does not maintain the minimum residual disinfectant concentration specified in § 109.710 at one or more sample sites shall include those sample sites in the monitoring conducted the following month.
(IV) Compliance with the minimum residual disinfectant concentration shall be determined in accordance with § 109.710.
(V) A public water system may substitute online residual disinfectant concentration monitoring and recording for grab sample monitoring and manual recording if it validates the online measurement for accuracy in accordance with § 109.304.
(ii) Chlorine dioxide.
* * * * * § 109.303. Sampling requirements.
* * * * * (e) Compliance monitoring samples for the contaminants listed under 40 CFR 141.40(a), 141.61(a) and (c), 141.62 and 141.88 may be composited in accordance with 40 CFR 141.23(a)(4), 141.24(f)(14) and (h)(10) and 141.88(a)(1)(iv) (relating to inorganic chemical sampling and analytical requirements; organic chemicals, sampling and analytical requirements; and monitoring requirements for lead and copper in source water) except:
* * * * *
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.