Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Bulletin website includes the following: Rulemakings by State agencies; Proposed Rulemakings by State agencies; State agency notices; the Governor’s Proclamations and Executive Orders; Actions by the General Assembly; and Statewide and local court rules.

PA Bulletin, Doc. No. 20-338a

[50 Pa.B. 1398]
[Saturday, March 7, 2020]

[Continued from previous Web Page]

LAND RECYCLING AND
ENVIRONMENTAL REMEDIATION

UNDER ACT 2, 1995
PREAMBLE 1


Acknowledgment of Notices of Intent to Remediate Submitted Under the Land Recycling and Environmental Remediation Standards Act (35 P.S. §§ 6026.101—6026.908).

 Sections 302, 303, 304 and 305 of the Land Recycling and Environmental Remediation Standards Act (Act) require the Department of Environmental Protection (Department) to publish in the Pennsylvania Bulletin an acknowledgment noting receipt of any Notices of Intent to Remediate. An acknowledgment of the receipt of a Notice of Intent (NOI) to Remediate is used to identify a site where a person proposes to, or has been required to, respond to a release of a regulated substance at a site. Persons intending to use the background standard, Statewide health standard, the site-specific standard, or who intend to remediate a site as a special industrial area, must file a (NOI) to Remediate with the Department. A NOI to Remediate filed with the Department provides a brief description of the location of the site, a list of known or suspected contaminants at the site, the proposed remediation measures for the site, and a description of the intended future use of the site. A person who demonstrates attainment of one, or a combination of the cleanup standards, or who receives approval of a special industrial area remediation identified under the Act, will be relieved of further liability for the remediation of the site for any contamination identified in reports submitted to and approved by the Department. Furthermore, the person shall not be subject to citizen suits or other contribution actions brought by responsible persons not participating in the remediation.

 Under Sections 304(n)(1)(ii) and 305(c)(2) of the Act, there is a 30-day public and municipal comment period for sites proposed for remediation using a site-specific standard, in whole or in part, and for sites remediated as a special industrial area. This period begins when a summary of the NOI to Remediate is published in a newspaper of general circulation in the area of the site. For the following identified site(s), proposed for remediation to a site-specific standard or as a special industrial area, the municipality, within which the site is located, may request to be involved in the development of the remediation and reuse plans for the site if the request is made within 30-days of the following specified date. During this comment period the municipality may request that the following identified person, as the remediator of the site, develop and implement a public involvement plan. Requests to be involved, and comments, should be directed to the remediator of the site.

 For further information concerning the content of a NOI to Remediate, please contact the Environmental Cleanup Program Manager in the Department of Environmental Protection Regional Office under which the notice appears. If information concerning this acknowledgment is required in an alternative form, contact the Community Relations Coordinator at the appropriate Regional Office listed. TDD users may telephone the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

 The Department of Environmental Protection has received the following Notice(s) of Intent to Remediate:

Southeast Region: Environmental Cleanup Program Manager, 2 East Main Street, Norristown, PA 19401.

1620-1650 North Street, 1620-1650 North 5th Street, City of Philadelphia, Philadelphia County. Jennifer Poole, PG, Pennoni Associates, 1900 Market Street, Suite # 300, Philadelphia, PA 19103 on behalf of Larry McKnight, Riverwards Group, 3020 Richmond Street, Philadelphia, PA 19134 submitted a Notice of Intent to Remediate. A release of heating oil contaminated the groundwater on the site. The proposed cleanup standard for the site is Statewide Health Standard. The Notice of Intent to Remediate was published in the Metro Philadelphia on January 28, 2020.

Commercial Property, 105 Bala Avenue, Lower Merion Township, Montgomery County. Henry Bienkowski, PG, Crawford Environmental Services, Inc., 20 Cardinal Drive, Birdboro, PA 19508 on behalf of Garrett Bergman, P.O. Box 465, Narberth, PA 19072 submitted a Notice of Intent to Remediate. No. 2 fuel oil has contaminated soil and groundwater at the site. The proposed future use of the property will be non-residential as a professional office building. The proposed cleanup standard for the site is Site-Specific Standard. The Notice of Intent to Remediate was published in the Metro Philadelphia on January 26, 2020.

REGISTRATION FOR RESIDUAL WASTE GENERAL PERMITS


Registration(s) Received Under the Solid Waste Management Act; the Municipal Waste Planning, Recycling and Waste Reduction Act; and Residual Waste Regulations for a General Permit to Operate Residual Waste Processing Facilities and the Beneficial Use of Residual Waste other than Coal Ash.

Southwest Region: Regional Solid Waste Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, Telephone 412-442-4000.

General Permit Application No. WMGR123SW042. Range Resources-Appalachia, LLC, 3000 Town Center Blvd., Canonsburg, PA 15317. A request for registration for coverage under General Permit WMGR123 to construct and operate the Bedillion Day Tank Pad Reuse Water Storage Facility for storage and reuse of oil and gas liquid waste at a site located in Amwell Township, Washington County. The registration request was received in the Regional Office on February 13, 2020 and accepted as administratively complete on February 24, 2020.

DETERMINATION FOR APPLICABILITY FOR MUNICIPAL WASTE GENERAL PERMITS


Application(s) for Determination of Applicability for General Permit Under the Solid Waste Management Act (35 P.S. §§ 6018.101—6018.1003); the Municipal Waste Planning, Recycling and Waste Reduction Act (53 P.S. §§ 4000.101—4000.1904); and Municipal Waste Regulations for a General Permit to Operate Municipal Waste Processing Facilities and/or the Beneficial Use of Municipal Waste.

Northwest Region: Regional Solid Waste Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

General Permit No. WMGM043NW006. Fox & Sons Excavating, LLC, 237 North Main Street, Clarendon, PA 16313. An application for a Determination of Applicability under municipal waste General Permit WMGR043 for the acceptance, transfer, and processing prior to beneficial use of construction and demolition waste materials at 237 North Main Street, in Clarendon, Warren County, was received on February 14, 2020, and deemed administratively complete by the Regional Office. Persons interested in reviewing the general permit or the application may contact the Department of Environmental Protection, Regional Files, 230 Chestnut Street, Meadville, PA 16335-3481, 814-332-6078. TDD users may contact the Department through the Pennsylvania AT&T Relay Service, (800) 654-5984.


Application(s) for Determination of Applicability Received Under the Solid Waste Management Act (35 P.S. §§ 6018.101—6018.1003); the Municipal Waste Planning, Recycling and Waste Reduction Act (53 P.S. §§ 4000.101—4000.1904); and Residual Waste Regulations for a General Permit to Operate Residual Waste Processing Facilities and/or the Beneficial Use of Residual Waste Other Than Coal Ash.

Southcentral Region: Regional Solid Waste Manager, 909 Elmerton Avenue, Harrisburg, PA 17110, Telephone 717.705.4706.

General Permit Application No. WMGR081SC003. Gigabiter LLC, 822 North Reading Avenue, Boyertown, PA 19512, Colebrookdale Township, Berks County. This general permit authorizes the processing of uncontaminated and source-separated electronic devices by disassembling and mechanical processing (by sizing, shaping, separating and volume reduction only), and associated storage prior to reuse or recycling at the processing or transfer facility. The application for determination of applicability was determined to be complete by the Southcentral Regional Office on February 19, 2020.

 Comments concerning the application should be directed to Mr. John Oren, P.E., Permits Section Chief, Southcentral Regional Office, Waste Management Program, 909 Elmerton Avenue, Harrisburg, PA 17110. Persons interested in obtaining more information about the general permit application may contact, the Southcentral Regional Office's Waste Management Program at 717.705.4706. TDD users may contact the Department through the Pennsylvania AT&T Relay Service, (800) 654-5984. Public comments must be submitted within 60 days of this notice and may recommend revisions to, and approval or denial of the application.

OPERATE WASTE PROCESSING OR DISPOSAL AREA OR SITE


Applications Deemed Administratively Complete Under the Solid Waste Management Act (35 P.S. §§ 6018.101—6018-1003), The Municipal Waste Planning, Recycling And Waste Reduction Act (53 P.S. §§ 4000.101—4000.1904) And Regulations To Operate Solid Waste Processing Or Disposal Area Or Site.

Southcentral Region: Regional Solid Waste Manager, 909 Elmerton Avenue, Harrisburg, PA 17110-8200.

Permit Application No. 301333. Waste Recovery Solutions, LLC, 343 King Street, Myerstown, PA 17067, Jackson Township, Lebanon County. An application for a permit renewal was submitted by Waste Recovery Solutions, LLC, for continued operation of their residual waste processing facility located in Jackson Township, Lebanon County. The current permit expires May 23, 2020. This application was deemed administratively complete by the Southcentral Regional Office on February 11, 2020.

 Comments concerning the application should be directed to John Oren, Permits Chief, Waste Management Program, 909 Elmerton Avenue, Harrisburg, PA 17110-8200. Persons interested in obtaining more information about this permit application may contact the Southcentral Regional Office at (717) 705-4706. TDD users may contact the Department through the Pennsylvania AT&T Relay Service, (800) 654-5984. Public comments must be submitted within 60 days of this notice and may recommend revisions to, and approval or denial of the application.

Permit Application No. 101100. Waste Management Disposal Services of Pennsylvania, Inc., 9446 Letzburg Road, Greencastle, PA 17225, Antrim and Montgomery Townships, Franklin County. An application for a permit renewal was submitted by Waste Management Disposal Services of Pennsylvania, Inc., for continued operation of the Mountain View Reclamation landfill located in Antrim and Montgomery Townships, Franklin County. The current permit expires August 1, 2020. This application was deemed administratively complete by the Southcentral Regional Office on February 10, 2020.

 Comments concerning the application should be directed to John Oren, Permits Chief, Waste Management Program, 909 Elmerton Avenue, Harrisburg, PA 17110-8200. Persons interested in obtaining more information about this permit application may contact the Southcentral Regional Office at (717) 705-4706. TDD users may contact the Department through the Pennsylvania AT&T Relay Service, (800) 654-5984. Public comments must be submitted within 60 days of this notice and may recommend revisions to, and approval or denial of the application.

AIR QUALITY

PLAN APPROVAL AND OPERATING
PERMIT APPLICATIONS

 The Department has developed an ''integrated'' plan approval, State Operating Permit and Title V Operating Permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the general public. This approach allows the owner or operator of a facility to submit permitting documents relevant to its application for all sources related to a facility or a proposed project, affords an opportunity for public input, and provides for a decision on the issuance of the necessary permits.

 The Department received applications for Plan Approvals or Operating Permits from the following facilities. Copies of the application, the Department's analysis, all pertinent documents used in the evaluation of the application and subsequently prepared proposed plan approvals/operating permits are available for public review during normal business hours at the appropriate Department Regional Office. Appointments for scheduling a review must be made by calling the appropriate Department Regional Office. The address and phone number of the Regional Office is listed before the application notices.

 Persons wishing to file a written protest or provide comments or additional information, which they believe should be considered prior to the issuance of a permit, may submit the information to the Department's Regional Office. A 30-day comment period from the date of this publication will exist for the submission of comments, protests and information. Each submission must contain the name, address and telephone number of the person submitting the comments, identification of the proposed Plan Approval/Operating Permit including the permit number and a concise statement regarding the relevancy of the information or objections to issuance of the permit.

 A person wishing to request a hearing may do so during the 30-day comment period. A public hearing may be held, if the Department, in its discretion, decides that a hearing is warranted based on the information received. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper, the Pennsylvania Bulletin or by telephone, when the Department determines this type of notification is sufficient. Requests for a public hearing and any relevant information should be directed to the appropriate Department Regional Office.

 Permits issued to the owners or operators of sources subject to 25 Pa. Code Chapter 127, Subchapter D or E, or located within a Title V facility or subject to 25 Pa. Code § 129.51(a) or permits issued for sources with limitations on their potential to emit used to avoid otherwise applicable Federal requirements may be submitted to the United States Environmental Protection Agency for review and approval as a revision to the State Implementation Plan. Final Plan Approvals and Operating Permits will contain terms and conditions to ensure that the sources are constructed and operating in compliance with applicable requirements in the Air Pollution Control Act (35 P.S. §§ 4001—4015), 25 Pa. Code Chapters 121—145, the Federal Clean Air Act (42 U.S.C.A. §§ 7401—7671q) and regulations adopted under the Federal Clean Air Act.

 Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

PLAN APPROVALS


Plan Approval Applications Received under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B that may have special public interest. These applications are in review and no decision on disposition has been reached.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481.

Contact: Dave Balog, New Source Review Chief, (814) 332-6328.

03-269B: PulFlex Technologies, LLC (P.O. Box 7159, New Castle, PA 16107), plan approval application received for the installation and initial operation of composite plastic part production equipment in Ford City, Armstrong County. This will be a natural minor facility.


Intent to Issue Plan Approvals and Intent to Issue or Amend Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B. These actions may include the administrative amendments of an associated operating permit.

Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18701-1915.

Contact: Raymond Kempa, New Source Review Chief, (570) 826-2507.

48-00005C: Hercules Cement Company dba Bucci Unicem USA (501 Hercules Drive, P.O. Box 69, Stockertown, PA 18083) submitted an application to the Department of Environmental Protection for a plan approval for the streamlining to their existing operating permit conditions at their facility located in Stockertown Borough, Northampton County. The facility currently operates under Title V Operating Permit No. 48-00005. This plan approval will be incorporated into the Title V Operating Permit through an administrative amendment at a later date.

 This application seeks to streamline existing permit conditions into more recent requirements under 40 CFR Part 63, Subpart LLL, National Emission Standards for Hazardous Air Pollutants from Portland Cement Manufacturing Industry. The Department's review of the information submitted by Hercules Cement indicates that the proposed modifications will meet all applicable air quality requirements pertaining to air contamination sources and the emission of air contaminants, including the BAT requirements. The company shall comply with 25 Pa. Code § 123.31 for malodorous emissions. The company shall comply with 25 Pa. Code § 123.13 for particulate emissions. The company shall comply with 25 Pa. Code § 123.41 for visible emissions. The company is subject to 40 CFR Part 63 Subpart LLL requirements. CEMS will continue to be used to measure NOx and SO2 emissions. The Plan approval and Operating Permit will include testing, monitoring, record keeping, and reporting requirements designed to keep the sources operating within all applicable air quality requirements. For further details, contact Ray Kempa at (570) 826-2511 within 30 days after publication date.

 The Plan approval and Operating Permit will include testing, monitoring, record keeping, and reporting requirements designed to keep the sources operating within all applicable air quality requirements. For further details, contact Ray Kempa at (570) 826-2511 within 30 days after publication date.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18701.

 Any person(s) wishing to provide DEP with additional information, which they believe should be considered prior to the issuance of this permit, may submit the information to the address shown in the preceding paragraph. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit No. 48-00005C, and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A public hearing may be held, if the Department of Environmental Protection, in its discretion, decides that such a hearing is warranted based on the comments received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, where DEP determines such notification is sufficient. Written comments or requests for a public hearing should be directed to Ray Kempa, Environmental Group Manager, New Source Review Section, Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18701, Phone 570-826-2511 within 30 days after publication date.

Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701.

Contact: Muhammad Q. Zaman, Program Manager, (570) 327-3648.

17-00068B: PA Waste, LLC (175 Bustleton Pike, Feasterville, PA 19053) for the construction and operation of a municipal solid waste landfill (Source P101) at the proposed Camp Hope Run Landfill site in Boggs Township, Clearfield County. The air contaminant emissions from the proposed landfill will be captured by a landfill gas collection system and controlled by a 3,000 cubic foot per minute enclosed flare (Control Device C101). Additional sources at the facility include the haul roads (Source P102) and a leachate treatment system (Source P103). This is a Title V facility for which an operating permit application will be required at a later date.

 The Department's review of the information contained in the application submitted by PA Waste, LLC, indicates that the sources will comply with all applicable air quality regulatory requirements pertaining to air contamination sources and the emission of air contaminants, including the fugitive air contaminant emission requirement of 25 Pa. Code § 123.1, the particulate matter emission limitation of 25 Pa. Code § 123.13, the sulfur oxide emission limitation of 25 Pa. Code § 123.21 and the visible emission limitation of 25 Pa. Code § 123.41. Additionally, the Department has determined that the proposed facility satisfies best available technology requirements pursuant to 25 Pa. Code §§ 127.1 and 127.12 (BAT) as well as the requirements of the Standards of Performance for Municipal Solid Waste Landfills specified in 40 CFR Part 60 Subpart XXX. If the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specification of the application for Plan Approval 17-00068B, the requirements established in the plan approval will be incorporated into a new Title V Operating Permit. The Title V operating permit application will be required at a later date.

 Based upon this finding, the Department proposes to issue a plan approval for the construction and operation of the proposed landfill. In addition to the emission limitations, the following is a brief description of the conditions the Department intends to place in the plan approval in order to ensure compliance with all applicable air quality regulatory requirements.

 1. Pursuant to the BAT, the permittee shall not permit the following air contaminant emissions from the exhaust of Control Device ID C101 associated with Source P101 in excess of the following limitations:

 a. nitrogen oxides (NOx, expressed as NO2)—0.06 pound per million Btu of heat input.

 b. carbon monoxide (CO)—0.20 pound per million Btu of heat input.

 c. sulfur oxides (SOx, expressed as SO2)—3.63 pounds per hour.

 d. particulate matter (PM/PM10/PM2.5)—1.53 pound per hour.

 e. non-methane organic compounds (NMOC)—0.47 pound per hour.

 2. Pursuant to the BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, Control Device C101 associated with Source P101 shall reduce the non-methane organic compound emissions by 98% or greater or reduce the outlet non-methane organic compound concentration to not equal or exceed 20 parts per million, by volume, dry basis (ppmdv) at 3% oxygen.

 3. Pursuant to the BAT, there shall be no visible emissions from Control Device C101 associated with Source P101, except for periods during startup and shut down not to exceed 10% opacity for a period or periods aggregating more than three minutes in any 1 hour.

 4. Pursuant to the BAT, Control Device C101 shall be equipped with a propane enrichment system to allow propane fuel to be bled into the landfill gas.

 5. Pursuant to the BAT, the combustion chamber temperature of Control Device C101 shall not be less than 1,600°F, at any time.

 6. Pursuant to the BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, Control Device C101 associated with Source P101 shall maintain, for each 3-hour period of operation based on rolling hourly data, an average combustion temperature of no more than 28°C (82°F) below the average combustion temperature.

 7. Pursuant to the BAT, the residence time of the air contaminants in the combustion chamber of Control Device C101 shall not be less than 1.13 second.

 8. Pursuant to BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, Control Device C101 shall be equipped with instrumentation to continuously monitor and record the combustion temperature and having a minimum accuracy of +/- one (1.0) percent of the temperature being monitored.

 9. Pursuant to the BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, Control Device C101 shall be equipped with instrumentation to continuously monitor the gas flow to the flare and record the flow once every 15 minutes.

 10. Pursuant to the BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, Control Device C101 shall be equipped with a bypass line valve in the closed position with a car-seal or a lock-and-key type configuration. A visible inspection of the seal or closure mechanism shall be performed at least once per month to ensure the valve is maintained in the closed position and that the gas flow is not diverted through the bypass line.

 11. Pursuant to the BAT, the piping incorporated in the landfill gas collection system incorporated in Source P101 shall be sized to accommodate the maximum gas generation rate to be associated with the respective field(s). The gas collection rate shall at no time be less than the gas generation rate of the respective field.

 12. Pursuant to the BAT, the horizontal collection lines in the landfill gas collection system incorporated in Source P101 shall be located no more than 150 feet apart laterally and 50 feet apart vertically. The vertical well spacing in the landfill gas collection system incorporated in Source P101 shall not exceed a lateral spacings of 215 feet unless otherwise demonstrated as acceptable pursuant to the methods outlined in Appendix E of 40 CFR Part 60 Subpart WWW.

 13. Pursuant to the BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, Control Device C101 shall be equipped with an automatic pilot ignition system that utilizes propane as a separate fuel source which ensures complete and immediate combustion of the landfill gas.

 14. Pursuant to the BAT, Control Device C101 shall be equipped with an ultraviolet scanner with controller to confirm that a flame is present anytime that landfill gas is present.

 15. Pursuant to the BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, the landfill gas collection system shall be operated so that the methane concentration is less than 500 parts per million above background at the surface of the landfill.

 16. Pursuant to the BAT and 40 CFR Part 60 Subpart XXX Sections 60.760—60.769, each well associated with the gas collection system incorporated in Source P101 shall be installed no later than 60 days after the date on which the initial solid waste has been in place.

 17. Pursuant to the BAT, gas collection and destruction (enclosed flare, C101) in a field incorporated in Source P101 shall commence no later than two (2) years after refuse has first been deposited within that field. At that time all wells within the field shall be tied into the gas collection system associated with Source P101. No gas well shall be vented directly to the atmosphere from a field at any time after gas collection is required to commence.

 18. Pursuant to 25 Pa. Code § 123.31, The permittee shall not permit the emission into the outdoor atmosphere of any malodorous air contaminants from any source in a manner that the malodors are detectable outside the property of the person on whose land the source is being operated.

 19. Pursuant to the BAT, Control Device C101 shall be equipped with an automatic shut-off mechanism designed to immediately stop the flow of gases when a flame-out occurs. During restart or start-up, there should be sufficient flow of auxiliary fuel to the burners such that unburned landfill gases are not emitted to the atmosphere.

 20. Pursuant to the BAT, Control Device C101 shall be designed such that there are no visible flames beyond the flare shroud during normal operation.

 21. The permittee shall keep records of the following information for a minimum of five (5) years:

 a. The total emissions and supporting calculations of nitrogen oxides, carbon monoxides, sulfur oxides, particulate matter and non-methane organic compounds from Control Device C101 on a monthly basis to verify compliance with the respective annual emission limits.

 b. The combustion temperature of Control Device C101 on a continuous basis.

 22. The permittee shall perform nitrogen oxide, carbon monoxide and non-methane organic compound stack tests upon Control Device C101 associated with Source P101 within 120 days from the initial operation to verify compliance with the emission limits for nitrogen oxide, carbon monoxide and non-methane hydrocarbon emissions from Control Device C101 associated with Source P101.

 a. The performance test shall consist of three (3) separate test runs and each run shall last at least one (1) hour in duration.

 b. All testing is to be done using reference method test procedures acceptable to the Department and all testing is to be performed while Control Device C101 is operating at maximum normal operating conditions.

 23. The permittee shall submit a plan approval application for the installation of another enclosed flare (control device) to control the higher landfill gas flow rates once the actual LFG flow rate equals 2,750 cfm.

 24. Pursuant to the BAT, all leachate generated at the facility shall be treated in Source P103.

 25. Pursuant to the BAT, the ammonia emissions from the Source P103 shall not exceed 0.30 ton in any 12 consecutive month period.

 26. Pursuant to BAT, an operable water truck equipped with a pressurized spray mechanism shall be kept on-site and filled with water at all times (except when refilling the truck) and shall be used for the prevention and control of fugitive air contaminant emissions from site haul roads and construction/operation activities associated with the landfill. The permittee shall water each site haul road and construction/operation area at the facility when the facility is in operation at least every two hours during months of June through September and at least twice per day during rest of the calendar year. The permittee is not required to water each site haul road and construction/operation area at the facility if the ground is frozen or freezing rain has fallen during the day. If at any time the fugitive dust emissions exceed the limitations of 25 Pa. Code § 123.1, the permittee shall take such control measures as are necessary to reduce the air contaminant emissions to within the acceptable limits.

 27. The permittee shall implement any effective winterization measure necessary to render the water truck capable of use under all weather conditions.

 28. Pursuant to the BAT, all loaded trucks entering or exiting the facility via public roadways shall have the truck beds completely tarped or otherwise covered. The permittee shall post easily visible signs explaining the previously listed requirement on the facility access road and elsewhere within the facility, as appropriate.

 29. Pursuant to the BAT, the permittee shall post speed limit signs indicating the speed limit on paved roads to be 15 MPH and unpaved roads to be 10 MPH for the prevention and control of fugitive air contaminant emissions from site haul roads.

 30. Pursuant to the BAT, the permittee shall maintain a permanent truck wash station, which all vehicles must pass through prior to exiting the facility property. Tires and undercarriage of each vehicle shall be washed as needed to prevent carry out of mud and dirt from the facility onto public roadways.

 Source P101 is subject to the requirements of 40 CFR Part 60 Subpart XXX Sections 60.760—60.769. The permittee shall comply with all applicable requirements of 40 CFR Sections 60.760—60.769.

 A copy of the plan approval application and the Department's review is available for public review between 8 a.m. and 4 p.m. at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review may be made by calling the Department at 570-327-0550. An electronic copy of the proposed plan approval can be accessed at the Department's web site at www.dep.pa.gov and then by following these menu selections: DEP > About DEP > Regional Resources > Northcentral Regional Office > Community Information > Camp Hope Run Landfill. Written comments on the proposed plan approval or requests for a public hearing should be directed to Muhammad Q. Zaman, Environmental Program Manager, Department of Environmental Protection, Air Quality Program, Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701, 570-327-3648.

OPERATING PERMITS


Intent to Issue Title V Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter G.

Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110.

Contact: Thomas Hanlon, Facilities Permitting Chief, (717) 705-4862, Thomas Bianca, New Source Review Chief, (717) 705-4863, or William Weaver, Regional Air Quality Manager, (717) 705-4702.

05-05022: Bedford Reinforced Plastics (264 Reynoldsdale Road, Bedford, PA 15522) to issue a Title V Operating Permit renewal for the fiberglass pultrusion operation at the Bedford plant located in East Saint Clair Township, Bedford County. The actual 2018 emissions from the facility were 7.18 tons of VOCs and 7.18 tons of a single HAP. The Operating Permit will include emission limits and work practice standards along with testing, monitoring, recordkeeping, and reporting requirements to ensure the facility complies with the applicable air quality regulations. Among other items, the conditions include provisions derived from 40 CFR Part 63 Subpart WWWW for reinforced plastic composites production.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481.

Contact: Matthew Williams, Facilities Permitting Chief, (814) 332-6328.

03-00027: Keystone-Conemaugh Projects, LLC (175 Cornell Road, Suite 1, Blairsville, PA 15717). The Department intends to issue a renewal of the Title V Operating Permit for the operation of the electrical generation facility in Plum Creek Township, Indiana County.

 The facility's major emission sources include two tangential pulverized coal-fired (PC) boilers, each with nominal maximum heat inputs of 8,717 MMBtu/hr, two 138 MMBtu/hour auxiliary boilers, four 3,600 bhp peaking diesel electrical generators, emergency diesel engines and fire pumps, coal handling, ash disposal, limestone and gypsum operations, plant haul roads, cooling towers, miscellaneous propane heaters and sorbent handling and storage. The facility reported actual emissions in TPY for 2018 as: 6,399.29 NOx, 4,911.85 CO, 23,950.58 SOx, 298.2 PM, 664.6 PM10, 33.36 VOC, 19.8 HAPs, and 12,680,778.06 CO2. The facility is subject to the Title V Operating Permit requirements adopted in 25 Pa. Code Chapter 127, Subchapter G. The facility is subject to the New Source Performance Standards for Nonmetallic Mineral Processing Plants (Subpart OOO) and Stationary Compression Ignition Internal Combustion Engines (Subpart IIII); the National Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines (Subpart ZZZZ), Industrial, Commercial, and Institutional Boilers and Process Heaters (Subpart DDDDD) and Coal and Oil Fired Electric Steam Utility Steam Generating Units (Subpart UUUUU); and the Cross State Air Pollution Rule (CASPR) for NOx Annual Trading Program (Subparts AAAAA), SO2 Group 1 Trading Program (Subpart CCCCC), and NOx Ozone Season Group 2 Trading Program (Subpart EEEEE). The renewal permit includes additional operation requirements, monitoring requirements, and recordkeeping requirements to ensure compliance with the Clean Air Act and the Air Pollution Control Act.


Intent to Issue Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter F.

Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401.

Contact: Janine Tulloch-Reid, Facilities Permitting Chief, (484) 250-5920.

46-00142: Custom Processing Services, LLC (461 State Street, East Greenville, PA 18041), for the renewal of a State Only, Natural Minor Operating Permit Renewal in East Greenville Borough, Montgomery County. The permit is for a non-Title V (State Only) facility. The facility's potential to emit criteria pollutants is less than major thresholds; therefore, the facility is a Natural Minor. The company provides customized grinding, milling, blending, and drying services of various mineral products. The pollutant of concern is particulate matter. Dust collectors are used on all sources for particulate matter control. The renewed permit includes monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable local, State, and Federal air quality requirements.

Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110.

Contact: Thomas Hanlon, Facilities Permitting Chief, (717) 705-4862, Thomas Bianca, New Source Review Chief, (717) 705-4863, or William Weaver, Regional Air Quality Manager, (717) 705-4702.

34-03007: Dominion Energy Transmission, Inc. (500 Dominion Blvd., Glenn Allen, VA 23060) for the operation of a natural gas compressor station facility in Lack Township, Juniata County. This is for renewal of the existing State-Only Permit. The actual 2018 emissions were 0.01 tpy PM-10, 0.01 tpy PM-2.5, 1.19 tpy NOx, 0.50 tpy CO, 3.03 tpy VOC, and 0.03 tpy SO2. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations.

Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701.

Contact: Muhammad Q. Zaman, Program Manager, 570-327-3648.

19-00014: Hanson Aggregates PA, LLC (7660 Imperial Way, Allentown, PA 18195) to issue a renewal State Only Operating Permit for the Bloomsburg Quarry located in Hemlock Township, Columbia County. The facility is currently operating under State Only Operating Permit 19-00014. The facility's sources include a non-metallic mineral crushing plant consisting of multiple crushers, conveyors and screens, one cold cleaning degreaser, 2.3 miles of onsite unpaved haul roads and a miscellaneous heater, engine and storage tanks. The facility has potential emissions of 6.12 TPY of CO; 9.71 TPY of NOx; 0.55 TPY of SOx; 17.54 TPY of PM/PM10; 13.22 TPY of VOCs; 6.74 TPY of combined hazardous air pollutants; 946 TPY GHGs. One crusher at this plant is subject to 40 CFR 60, Subpart OOO—Standards of Performance for Nonmetallic Mineral Processing Plants. The emission limits and work practice standards along with testing, monitoring, record keeping, and reporting requirements have been included in the operating permit to ensure the facility complies with all applicable Federal and State air quality regulations. These operating permit conditions have been derived from the applicable requirements of 25 Pa. Code Chapters 121—145, as well as 40 CFR Part 60. All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

59-00027: UGI Storage Company (1 Meridian Blvd, Suite 2C01, Wyomissing, PA 19610) to issue a renewal State Only Operating Permit for their Palmer Compressor Station located in Farmington Township, Tioga County. The facility is currently operating under State Only Operating Permit 59-00027. The facility's main sources include three natural gas-fired compressor engines and one diesel fired emergency generator. The facility has potential emissions of 23.4 tons per year (tpy) of NOx, 7.4 tpy of CO, 1.6 tpy of PM, 7.7 tpy of VOCs, 0.2 tpy of SOx, 4.0 tpy of HAPs, and 24,134 tpy of GHGs. No emission or equipment changes are being proposed by this action. The emission limits, throughput limitations and work practice standards along with testing, monitoring, recordkeeping and reporting requirements have been included in the operating permit to ensure the facility complies with all applicable Federal and State air quality regulations. These operating permit conditions have been derived from the applicable requirements of 25 Pa. Code Chapters 121—145 as well as 40 CFR Parts 60 and 63. All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

Southwest Regional Office, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

Contact: Thomas Joseph, Facilities Permitting Chief, 412.442.4336.

63-00990: Donora Dock, LLC (1501 Ligonier St, Latrobe, PA 15650). In accordance with 25 Pa. Code §§ 127.424, 127.425 and 127.521, the Department is providing notice of its intent to issue a natural minor State Only Operating Permit for the operation of a coal and pet coke transfer facility located in Carroll Township, Washington County.

 Operations at the facility include the offloading of clean bituminous coal and pet coke by barge and truck. Activities consist of loading/unloading, transfer, blending, stockpiling, hauling, and trans-loading of up to 2.6 million tons of material per year. Potential emissions from this facility are estimated at 44.49 tons of PM10 per year of fugitive emissions.

 The facility is subject to the applicable requirements of 25 Pa. Code Article III, Chapters 121—145. The proposed operating permit includes emission and throughput limitations, monitoring, work practice, reporting, and recordkeeping requirements for the facility.

 The application, DEP's Review Memorandum, and the proposed permit are available for public review during normal business hours at DEP's Southwest Regional Office, 400 Waterfront Drive, Pittsburgh, PA 15222. A file review can be scheduled through the DEP's website at https://www.dep.pa.gov/Citizens/PublicRecords/Pages/Informal-File-Review.aspx.

 Any person may submit comments, a request for the Department to hold a public hearing, or a protest to the proposed operating permit or a condition thereof by submitting the information to Nick Waryanka, P.E., Air Quality Engineer, at the Southwest Regional Office. A 30-day comment period from the date of publication of this notice will exist for the submission of comments. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit (specify Operating Permit 63-00990) and concise statements regarding the relevancy of the information in the proposed permit or objections to issuance of the permit.

 A public hearing may be held in accordance with 25 Pa. Code § 127.429, if the Department, in its discretion, decides that such a hearing is warranted based on the information received. If a public hearing is held, all persons who have properly filed a protest under 25 Pa. Code § 127.426 may appear and give testimony. The applicant, the protestant, and other participants will be notified of the decision to hold a hearing (and the time, place and purpose of such hearing) by publication in the newspaper or by the Pennsylvania Bulletin, or by telephone, where the Department determines such notification by telephone is sufficient.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481.

Contact: Matthew Williams, Facilities Permitting Chief, (814) 332-6940.

32-00424: Rosebud Mining Company Brush Valley Plant (301 Market Street, Kittanning, PA 16201). The Department intends to issue a renewal of the State Only Operating Permit for operating of a coal preparation plant located in Center Township, Indiana County. The subject facility consists of a raw coal mine belt, a raw coal radial stacker, a double deck screen, a fine coal radial stacker, middling and oversize coal belts, numerous storage piles, propane heater and three emergency generators. Emissions from the facility are based on the coal throughput limit of 1,000,000 tpy, 500 hours for each emergency generator, and AP-42 emission factors. The facility has the potential to emit 66.94 TPY PM, 9.44 TPY NOx, 3.28 TPY NOx + HC, 3.27 TPY CO, 3.27 TPY SOx, and 1.22 TPY VOC. The facility is a natural minor and is subject to State and Federal Regulations (40 CFR Part 60 Subpart Y and IIII). The renewal permit includes operation requirements, monitoring requirements, and recordkeeping requirements to ensure compliance with the Clean Air Act and the Air Pollution Control Act.

Philadelphia: Air Management Services, 321 University Avenue, Philadelphia, PA 19104-4543.

Contact: Edward Wiener, Chief of Source Registration at 215-685-9426.

 The City of Philadelphia, Air Management Services (AMS) intends to issue an initial Natural Minor Operating Permit for the following facility:

OP19-000014: The Sterling Apartments (1815 JFK Blvd, Philadelphia, PA 19103) for the operation of a commercial and residential condominium in the City of Philadelphia, Philadelphia County. The facility's air emission sources include two (2) boilers firing natural gas each rated less than 2 MMBtu/hr, six (6) boilers firing natural gas and/or No. 2 fuel oil rated at 3 MMBtu/each, one emergency generator firing diesel fuel rated at 896 HP, and three (3) cogen units firing natural gas rated at 100 HP each.

 The operating permit will be issued under 25 Pa. Code, Philadelphia Code Title 3 and Air Management Regulation XIII. Permit copies and other supporting information are available for public inspection at AMS, 321 University Avenue, Philadelphia, PA 19104. For further information, contact Edward Wiener at (215) 685-9426.

 Persons wishing to file protest, comments, or request a public hearing on the previously listed operating permit must submit the protest, comments or request for public hearing within 30 days from the date of this notice. Any protests or comments filed with AMS must include a concise statement of the objections to the permit issuance and the relevant facts upon which the objections are based. Based upon the information received during the public comment period, AMS may modify the operating permit or schedule a public hearing. The hearing notice will be published in the Pennsylvania Bulletin and a local newspaper at least thirty days before the hearing.

PLAN APPROVALS


Receipt of Plan Approval Applications and Intent to Issue Plan Approvals, and Intent to Issue Amended Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B and Subchapter F. These actions may include the administrative amendments of an associated operating permit.

Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18701-1915.

Contact: Raymond Kempa, New Source Review Chief—Telephone: 570-826-2531.

 Notice is hereby given in accordance with 25 Pa. Code §§ 127.44(a) and 127.45(a), that the Department of Environmental Protection (DEP) has received and intends to issue a Plan Approval to Medico Industries (1500 Highway 315, Wilkes-Barre, PA 18702) for their facility located in Plains Twp., Luzerne County. This Plan Approval No. 40-00136B will be incorporated into a State Only Permit through an administrative amendment at a later date.

 Plan Approval No. 40-00136B is for the installation of a two Wet Paint Line with filters and curing ovens and a descaling operation with baghouse. VOC emissions from the plant will remain under 50 TPY threshold limit, 12-month rolling sum. Particulate emissions will not exceed 0.02 grain/dscf from the baghouse. The company shall be subject to and comply with 25 Pa. Code § 129.52 for VOC emission limits. Total HAP emissions from the facility will be under 25 TPY, 12-month rolling sum. Single HAP emissions will be under 10 TPY, 12-month rolling sum. The company shall be subject to and comply with 25 Pa. Code § 123.31 for malodorous emissions. The company shall be subject to and comply with 25 Pa. Code § 123.41 for visible emissions. Emissions from the lines will be controlled by the use of a dry filters and curing oven. These limits will meet BAT requirements for this source. The Plan Approval and Operating permit will contain additional recordkeeping and operating restrictions designed to keep the facility operating within all applicable air quality requirements.

 Copies of the application, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711.

 Any person(s) wishing to provide DEP with additional information, which they believe should be considered prior to the issuance of this permit, may submit the information to the address shown in the preceding paragraph. Each written comment must contain the name, address and telephone number of the person submitting the comments, identification of the proposed permit No. 40-00136B and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A public hearing may be held, if the Department of Environmental Protection, in its discretion, decides that such a hearing is warranted based on the comments received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, where DEP determines such notification is sufficient. Written comments or requests for a public hearing should be directed to Ray Kempa, Chief, New Source Review Section, Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711, Phone 570-826-2511 within 30 days after publication date.

COAL & NONCOAL MINING
ACTIVITY APPLICATIONS

 Applications under the Surface Mining Conservation and Reclamation Act (52 P.S. §§ 1396.1—1396.31); the Noncoal Surface Mining Conservation and Reclamation Act (52 P.S. §§ 3301—3326); the Clean Streams Law (35 P.S. §§ 691.1—691.1001); the Coal Refuse Disposal Control Act (52 P.S. §§ 30.51—30.66); the Bituminous Mine Subsidence and Land Conservation Act (52 P.S. §§ 1406.1—1406.21). Mining activity permits issued in response to such applications will also address the applicable permitting requirements of the following statutes: the Air Pollution Control Act (35 P.S. §§ 4001—4015); the Dam Safety and Encroachments Act (32 P.S. §§ 693.1—693.27); and the Solid Waste Management Act (35 P.S. §§ 6018.101—6018.1003).

 The following permit applications to conduct mining activities have been received by the Department of Environmental Protection. A copy of the application is available for inspection at the District Mining Office indicated above each application. Notices of requests for 401 Water Quality Certifications are included in individual application notices, as noted.

 Written comments or objections, or requests for an informal conference, or a public hearing, as applicable, on a mining permit application may be submitted by any person or any officer or head of any Federal, State or local government agency or authority to the Department at the address of the District Mining Office indicated above each application within 30-days of this publication, or within 30-days after the last publication of the applicant's newspaper advertisement, as provided by 25 Pa. Code §§ 77.121—77.123 and 86.31—86.34 (relating to public notices of filing of permit applications, opportunity for comment, and informal conferences).

 Written comments or objections related to a mining permit application should contain the name, address and telephone number of persons submitting comments or objections; application number; and a statement of sufficient detail to inform the Department on the basis of comment or objection and relevant facts upon which it is based.

 Requests for an informal conference, or a public hearing, as applicable, on a mining permit application, as provided by 25 Pa. Code § 77.123 (relating to public hearing-informal conferences) or § 86.34 (relating to informal conferences), must contain the name, address and telephone number of the requestor; the application number; a brief summary of the issues to be raised by the requestor at the conference; and a statement whether the requestor desires to have the conference conducted in the locality of the proposed mining activities.

 Where a National Pollutant Discharge Elimination System (NPDES) number is listed, the mining activity permit application was accompanied by an application for an individual NPDES permit. A separate notice will be provided after the draft NPDES permit is prepared.

Coal Applications Received

Effluent Limits—The following range of effluent limits will apply to NPDES permits issued in conjunction with the associated coal mining activity permit and, in some cases, noncoal mining permits:


Table 1

30-Day Daily Instantaneous
Parameter Average Maximum Maximum
Iron (total) 1.5 to 3.0 mg/l 3.0 to 6.0 mg/l 3.5 to 7.0 mg/l
Manganese (total) 1.0 to 2.0 mg/l 2.0 to 4.0 mg/l 2.5 to 5.0 mg/l
Suspended solids 10 to 35 mg/l 20 to 70 mg/l 25 to 90 mg/l
Aluminum (Total) 0.75 to 2.0 mg/l 1.5 to 4.0 mg/l 2.0 to 5.0 mg/l
pH1 greater than 6.0; less than 9.0
Alkalinity greater than acidity1
1 The parameter is applicable at all times.

 A settleable solids instantaneous maximum limit of 0.5 ml/l applied to: surface runoff (resulting from a precipitation event of less than or equal to a 10-year 24-hour event) from active mining areas; active areas disturbed by coal refuse disposal activities; and mined areas backfilled and revegetated; and drainage (resulting from a precipitation event of less than or equal to a 1-year 24-hour event) from coal refuse disposal piles.

Moshannon District Mining Office: 186 Enterprise Drive, Philipsburg, PA 16866, 814-342-8200, (Contact: Janet Turner).

Government Financed Construction Contract (GFCC) No. 17-19-01 and General NPDES No. PAG02231719-001, Swisher Contracting, Inc., P.O. Box 1223, Clearfield, PA 16830, new GFCC contract for reclaiming abandoned mine land in Girard Township, Clearfield County affecting 12.9 acres. Receiving stream(s): Unnamed Tributaries to the West Branch of the Susquehanna River, classified for the following use(s): CWF. West Branch Susquehanna River Watershed TMDL. There are no potable water supply intakes within 10 miles downstream. Application received: February 3, 2020.

Noncoal Applications Received

Effluent Limits—The following effluent limits will apply to NPDES permits issued in conjunction with a noncoal mining permit:

Table 2

30-day Daily Instantaneous
Parameter Average Maximum Maximum
Suspended solids 10 to 35 mg/l 20 to 70 mg/l 25 to 90 mg/l
Alkalinity exceeding acidity*
pH* greater than 6.0; less than 9.0
* The parameter is applicable at all times.

 A settleable solids instantaneous maximum limit of 0.5 ml/l applied to surface runoff resulting from a precipitation event of less than or equal to a 10-year 24-hour event. If coal will be extracted incidental to the extraction of noncoal minerals, at a minimum, the technology-based effluent limitations identified under coal applications will apply to discharges of wastewater to streams.

Knox District Mining Office: P.O. Box 669, 310 Best Avenue, Knox, PA 16232-0669, 814-797-1191, (Cayleigh Boniger).

43080302. White Rock Silica Sand Company, Inc. (331 Methodist Road, Greenville, PA 16125). Renewal of NPDES Permit No. PA0258580 in Hempfield Township, Mercer County. Receiving streams: Unnamed tributaries to the Shenango River, classified for the following uses: WWF. There are no potable surface water supply intakes within 10 miles downstream. Application received: February 13, 2020.

Moshannon District Mining Office: 186 Enterprise Drive, Philipsburg, PA 16866, 814-342-8200, (Contact: Janet Turner).

59050301 and NPDES PA0256170. Glenn O. Hawbaker, Inc., 1952 Waddle Road, State College, PA 16803, renewal for an existing NPDES on a large noncoal surface mining site located in Lawrence Township, Tioga County affecting 44.49 acres. Receiving stream(s): Tioga River and Mutton Creek classified for the following use(s): WWF. Application received: February 18, 2020.

Pottsville District Mining Office: 5 West Laurel Boulevard, Pottsville, PA 17901, 570-621-3118, (Contact: Theresa Reilly-Flannery).

Permit No. 58192506 and NPDES Permit No. PA0226076. Celso F. Avila (684 Warner Road, Montrose, PA 18801), commencement, operation and restoration of a bluestone quarry operation and NPDES permit for discharge of treated mine drainage in Bridgewater Township, Susquehanna County affecting 10.5 acres, receiving stream: unnamed tributary to Fall Brook/Snake Creek Watershed, classified for the following uses: cold water fishes, migratory fishes and exceptional value waters—cold water fishes and migratory fishes. Application received: October 29, 2019.

Coal NPDES Draft Permits

California District Office: 25 Technology Drive, Coal Center, PA 15423, 724-769-1100, (Contact: Bonnie Herbert).

NPDES No. PA024256 (Mining Permit No. 30861601). Coresco, LLC, 966 Crafts Run Road, Maidsville, WV 26541, a renewal to the NPDES and mining activity permit for Dunkard Preparation Plant in Monongahela Township, Greene County, affecting 34.7 surface acres. Receiving stream(s): Monongahela River classified for the following use(s): WWF. TMDL. The application was considered administratively complete: January 15, 2019. Application received: December 22, 2017.

 Unless otherwise noted for a specific outfall, the proposed effluent limits for all outfalls in this permit are the BAT limits described previously for coal mining activities.

Outfall 001 discharges to: Monongahela River

 The proposed effluent limits for Outfall 001 (Lat: 39° 46` 50" Long: 79° 56` 09") are:

30-Day Daily Instant.
ParameterMinimum Average Maximum Maximum
Flow (mgd) - - - REPORT
Iron (mg/l) - 3.0 6.0 7.0
Suspended Solids (mg/l) - 35 70 90
Manganese (mg/l) - 2.0 4.0 5.0
Aluminum (mg/l) - - - REPORT
Sulfate (mg/l) - - - REPORT
Total Dissolved Solids (mg/l) - - - REPORT
Chloride (mg/l) - - - REPORT
pH (S.U.) 6.0 - - 9.0
Alkalinity, Total as CaCO3 (mg/l) - - - REPORT
Acidity, Total as CaCO3 (mg/l) - - - REPORT
Alkalinity, Net (mg/l) 0.0 - - -
Osmotic Pressure (mOs/kg) - - - REPORT

Outfall 002 discharges to: Monongahela River

 The proposed effluent limits for Outfall 002 (Lat: 39° 46` 51" Long: 79° 56` 09") are:

30-Day Daily Instant.
ParameterMinimum Average Maximum Maximum
Flow (mgd) - - - REPORT
Iron (mg/l) - 3.0 6.0 7.0
Suspended Solids (mg/l) - 35 70 90
Manganese (mg/l) - 2.0 4.0 5.0
Aluminum (mg/l) - - - REPORT
Sulfate (mg/l) - - - REPORT
Total Dissolved Solids (mg/l) - - - REPORT
Chloride (mg/l) - - - REPORT
pH (S.U.) 6.0 - - 9.0
Alkalinity, Total as CaCO3 (mg/l) - - - REPORT
Acidity, Total as CaCO3 (mg/l) - - - REPORT
Alkalinity, Net (mg/l) 0.0 - - REPORT
Osmotic Pressure (mOs/kg) - - - REPORT

Outfall 003 discharges to: Monongahela River

 The proposed effluent limits for Outfall 003 (Lat: 39° 46` 54" Long: 79° 56` 08") are:

30-Day Daily Instant.
ParameterMinimum Average Maximum Maximum
Flow (mgd) - - - REPORT
Iron (mg/l) - 3.0 6.0 7.0
Suspended Solids (mg/l) - 35 70 90
Manganese (mg/l) - 2.0 4.0 5.0
Aluminum (mg/l) - - - REPORT
Sulfate (mg/l) - - - REPORT
Total Dissolved Solids (mg/l) - - - REPORT
Chloride (mg/l) - - - REPORT
pH (S.U.) 6.0 - - 9.0
Alkalinity, Total as CaCO3 (mg/l) - - - REPORT
Acidity, Total as CaCO3 (mg/l) - - - REPORT
Alkalinity, Net (mg/l) 0.0 - - -
Osmotic Pressure (mOs/kg) - - - REPORT

Outfall 004 discharges to: Monongahela River

 The proposed effluent limits for Outfall 004 (Lat: 39° 46` 56" Long: 79° 56` 08") are:

30-Day Daily Instant.
ParameterMinimum Average Maximum Maximum
Flow (mgd) - - - REPORT
Iron (mg/l) - 3.0 6.0 7.0
Suspended Solids (mg/l) - 35 70 90
Manganese (mg/l) - 2.0 4.0 5.0
Aluminum (mg/l) - - - REPORT
Sulfate (mg/l) - - - REPORT
Total Dissolved Solids (mg/l) - - - REPORT
Chloride (mg/l) - - - REPORT
pH (S.U.) 6.0 - - 9.0
Alkalinity, Total as CaCO3 (mg/l) - - - REPORT
Acidity, Total as CaCO3 (mg/l) - - - REPORT
Alkalinity, Net (mg/l) 0.0 - - -
Osmotic Pressure (mOs/kg) - - - REPORT

Outfall 005 discharges to: UNT A to Monongahela River

 The proposed effluent limits for Outfall 005 (Lat: 39° 46` 47" Long: 79° 56` 18") are:

30-Day Daily Instant.
ParameterMinimum Average Maximum Maximum
Flow (mgd) - - - REPORT
Iron (mg/l) - 3.0 6.0 7.0
Suspended Solids (mg/l) - 35 70 90
Manganese (mg/l) - 2.0 4.0 5.0
Aluminum (mg/l) - - - REPORT
Sulfate (mg/l) - - - REPORT
Total Dissolved Solids (mg/l) - - - REPORT
Chloride (mg/l) - - - REPORT
pH (S.U.) 6.0 - - 9.0
Alkalinity, Total as CaCO3 (mg/l) - - - REPORT
Acidity, Total as CaCO3 (mg/l) - - - REPORT
Alkalinity, Net (mg/l) 0.0 - - -
Osmotic Pressure (mOs/kg) - - - REPORT

 EPA waiver is not in effect.

Noncoal NPDES Draft Permits

Cambria District Mining Office: 286 Industrial Park Road, Ebensburg, PA 15931, 814-472-1900, (Contact: Holly Calvetti).

NPDES No. PA0121126 (Mining Permit No. 5074SM3), New Enterprise Stone & Lime Company, Inc., 3912 Brumbaugh Road, P.O. Box 77, New Enterprise, PA 16664, renewal of an NPDES permit for a noncoal surface mine in Greene Township, Franklin County, affecting 256.1 acres. Receiving stream(s): unnamed tributary to/and Conococheague Creek, classified for the following use(s): CWF. Application received: January 2, 2020.

 Unless otherwise noted for a specific outfall, the proposed effluent limits for all outfalls in this permit are the BAT limits described previously for noncoal mining activities.

 The following outfall discharges to Conococheague Creek:

Outfall No. New Outfall (Y/N)
001—Sediment Pond N

 The following outfall discharges to unnamed tributary to Conococheague Creek:

Outfall No. New Outfall (Y/N)
002—Sediment Pond N

 The proposed effluent limits for the previously listed outfalls are as follows:

Outfalls: 001 and 002 30-Day Daily Instant.
Parameter Average Maximum Maximum
Total Iron 3.06.07.0
Total Manganese 2.04.05.0
Total Suspended Solids (mg/l) 35.070.090.0
Average Discharge Rate    1.0 MGD
pH (S.U.): Must be between 6.0 and 9.0 standard units at all times.
Alkalinity must exceed acidity at all times.

Pottsville District Mining Office: 5 West Laurel Boulevard, Pottsville, PA 17901, 570-621-3118, (Contact: Theresa Reilly-Flannery).

NPDES Permit No. PA0612308 on Surface Mining Permit No. 7475SM3. Keystone Cement Company (P.O. Box A, Bath, PA 18014), modification of an NPDES Permit for a limestone quarry operation in East Allen Township, Northampton County, affecting 581.0 acres. Receiving stream: Monocacy Creek, classified for the following uses: HQ—cold water and migratory fishes. Application received: August 15, 2018.

 Unless otherwise noted for a specific outfall, the proposed effluent limits for all outfalls in this permit are BAT limits described previously for noncoal mining activities.

 The following outfalls discharge to Monocacy Creek:

Outfall Nos. New Outfall (Y/N) Type
001 No Groundwater Sumps
002 No Groundwater Sumps
004 No Groundwater Sumps
Outfalls: 30-DayDailyInstantaneous
ParameterMinimum Average Maximum Maximum
pH1 (S.U.) 6.0 9.0
Total Suspended Solids 35.0 70.0 90.
001 Discharge MGD 4.0 4.0
002 Discharge MGD 3.03.0
004 Discharge MGD 12.0 14.7
1 The parameter is applicable at all times.
*Total combined discharge from 001, 002 and 004 will not exceed 16.5 MGD.


FEDERAL WATER POLLUTION
CONTROL ACT, SECTION 401

 The following permit applications, requests for Environmental Assessment approval and requests for 401 Water Quality Certification have been received by the Department of Environmental Protection. Section 401 of the Federal Water Pollution Control Act (FWPCA) (33 U.S.C.A. § 1341), requires the State to certify that the involved projects will not violate the applicable provisions of Sections 301—303, 306 and 307 of the FWPCA (33 U.S.C.A. §§ 1311—1313, 1316 and 1317), as well as relevant State requirements. Persons objecting to approval of a request for certification under Section 401 or to the issuance of a Dam Permit or Water Obstruction and Encroachment Permit, or the approval of an Environmental Assessment must submit any comments, suggestions or objections within 30-days of the date of this notice, as well as any questions to the office noted above the application. Comments should contain the name, address and telephone number of the person commenting, identification of the certification request to which the comments or objections are addressed, and a concise statement of comments, objections or suggestions including the relevant facts upon which they are based.

 The Department may conduct a fact-finding hearing or an informal conference in response to comments if deemed necessary. Each individual will be notified, in writing, of the time and place of a scheduled hearing or conference concerning the certification request to which the comment, objection or suggestion relates. Maps, drawings and other data pertinent to the certification request are available for inspection between the hours of 8:00 AM and 4:00 PM on each working day at the office noted above the application.

 If you are a person with a disability and wish to attend the hearing and you require an auxiliary aid, service or other accommodation to participate in the proceedings, please contact the specified program. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

WATER OBSTRUCTIONS AND ENCROACHMENTS


Applications Received Under the Dam Safety and Encroachments Act (32 P.S. §§ 693.1—693.27) and Section 302 of the Flood Plain Management Act (32 P.S. § 679.302) and Requests for Certification Under Section 401 of the Federal Water Pollution Control Act (33 U.S.C.A. § 1341(a)).

Southeast Region: Waterways and Wetlands Program, 2 East Main Street, Norristown, PA 19401, Telephone 484.250.5160.

Contact: Elaine Henderson, Clerk Typist 3, 484.250.5157.

Permit No. E2301220-001, Alliance Partners HSP, LLC, 40 Morris Avenue, Suite 230, Bryn Mawr, PA 19010, Eddystone Borough, Delaware County, ACOE Philadelphia District.

 To perform the following listed water obstruction and encroachment activities associated with the Alliance Eddystone Warehouse Development. The proposed project consists of the installation of two stormwater outfalls in the Delaware River (WWF, MF) and permanent floodplain impact. There are no impacts in wetlands.

 The site is approximately at 1500 East 2nd Street in Eddystone (Bridgeport, NJ-PA Lat. 30° 51` 19"; Long. -75° 20` 01") Eddystone Borough, Delaware County.

Permit No. E5101220-021, Beach Street Developer, LLC, 2337 Philmont Avenue, Huntingdon Valley, PA 19006, City of Philadelphia, Philadelphia County, ACOE Philadelphia District.

 Beach Street Developer, LLC is proposing to redevelop a previously filled vacant waterfront site and is proposing to construct and maintain 1,096 residential units, 17,279 square feet of retail space, and a waterfront walkway with a portion of the project located within the floodway and floodplain of the Delaware River (WWF-MF) and waterward of the 1894 Bulkhead Line. This activity will result in 0.50 acre of permanent floodway impact and 8.46 acres of regulated activity waterward of the 1894 Bulkhead Line due to grading and construction. This project is located at Piers 79 through 86 North, formerly home of Cramp Shipyard, at 2001 Beach Street in the Olde Richmond section of Philadelphia (USGS NJ Camden Quadrangle—Latitude 39.971237 N, Longitude 75.117208 W).

Southwest Region: Dana Drake, Waterways and Wetlands Program, 400 Waterfront Drive, Pittsburgh, PA 15222.

E26052-387, Heartland Fabrication, LLC, 1800 Paul Thomas Blvd., Brownsville, PA 15417, Luzerne Township and Brownsville Borough, Fayette County; Pittsburgh ACOE District.

 The applicant proposes to:

 Operate and maintain the following existing structures:

 1. Steel/Pipe tri-tie mooring structure that has a base of 8 feet by 15 feet.

 2. Concrete high wall that is 309 feet long, 40 feet high, and 5 feet wide.

 3. Timber Pile tri-tie mooring structure that has a base of 15 feet by 15 feet.

 4. Steel/Concrete deploying rails that are 139 feet long by 89 feet wide.

 5. Steel/Concrete recovery/deploying rails that are 272 feet long by 67 feet wide.

 6. Fixed Stiff-leg crane with a base of 14 feet by 13 feet.

 7. Steel floating/pile dock that is 459 feet long by 27 feet wide.

 8. Steel/Pipe tri-tie mooring structure that is 8 feet by 15 feet.

 9. Three Steel/Aggregate round cell Ice-Breakers with a diameter of 22 feet—9 inches.

 10. Four Steel/Aggregate round cell Mooring structures with a diameter of 15 feet—6 inches.

 Perpetually conduct maintenance dredging activities at the following locations:

 1. 40 feet by 400 feet (0.37 acre) area in front of the existing concrete highwall.

 2. 40 feet by 200 feet (0.18 acre) area directly in front of the existing Steel/Concrete deploying rails.

 3. 40 feet by 200 feet (0.18 acre) area directly in front of the existing Steel/Concrete recovery/deploying rails.

 4. 40 feet by 460 feet (0.43 acre) area in front of the existing steel floating/pile dock.

 5. 40 feet by 200 feet (0.18 acre) area directly downriver from three existing steel/aggregate round cell Ice-Breakers.

 For the purpose of operating and maintaining an existing barge maintenance and manufacturing facility along the right descending bank of the Monongahela River at Mile Point 57.2 and 58.0. The project site is located at 1800 Paul Thomas Boulevard, Brownsville, PA 15417 (California, USGS topographic quadrangle; N: 40°, 01`, 7.72"; W: -79°, 54`, 55.11"; Sub-basin 19C; USACE Pittsburgh District), in Brownsville Borough and Luzerne Township, Fayette County. Perpetual maintenance dredging will impact 1.34 total acre on the Monongahela River.

E6505220-001, Unity Township, 154 Beatty County Road, Latrobe, PA 15650, Unity Township, Westmoreland County; ACOE Pittsburgh District.

 To remove a floodplain obstruction within a FEMA defined floodway of Loyalhanna Creek (WWF) in accordance with 25 Pa. Code Chapter 106. The project site is located at 122 Newmeyer Lane, Latrobe, PA 15650 (Derry, PA USGS topographic quadrangle; N: 40° 17` 25.1808", W: -79° 22` 3.580"; Sub-basin) in Unity Township, Westmoreland County.

Northwest Region: Waterways and Wetlands Program, 230 Chestnut Street, Meadville, PA 16335-3481.

E1006220-001, Seneca Valley School District, 124 Seneca School Road, Harmony, PA 16037. Seneca Valley School District K-4/5-6, in Cranberry Township, Butler County, ACOE Pittsburgh District (Mars, PA Quadrangle N: 40°, 44`, 28"; W: -80°, 06`, 16").

 To conduct activities associated with constructing a new elementary school and required infrastructure on a 153-acre site in Cranberry Township, Butler County including permanent impacts to 0.16 acre of PEM wetlands and two improved crossing over UNTs to Brush creek permanently impacting a total 277 linear feet. Applicant proposes to buy 0.16 mitigation credits to account for impacts to PEM wetlands.

E1006220-003, Butler County Planning Commission, 124 West Diamond St, P.O. Box 1208, Butler, PA 16003. Hemphill Bridge T-570 over Gold Scheitter Creek, in Clinton, Butler County, ACOE Pittsburgh District (Curtisville, PA Quadrangle N: 40°, 40`, 59.60"; W: 79°, 47`, 27.4").

 To conduct the following activities associated with the reconstruction of a portion of Goldscheitter Road approximately 0.75 mile North on Goldscheitter Road from its intersection with Lardintown Rd:

 1. To remove the remaining portions of the decapitated Hemphill Bridge which is currently closed on Goldscheitter Road spanning Gold Scheitter Creek.

 2. To install and maintain a new single-span aluminum box culvert with a 25 feet-5 inches span, 10 feet -2 inches rise, skew of 60° 0` 0", and waterway opening of approximately 159.87 square feet.

 3. To remove the existing upstream 30 inch RCP culvert over a UNT to Gold Scheitter Creek carrying Goldscheitter Road approximately 300 feet North of the Hemphill Bridge.

 4. To install and maintain an aluminum box culvert with a 9 feet -2 inch span, 3 feet -3 inch rise, skew of 51° 41` 28", and overall waterway opening of approximately 159.87 square feet.

Eastern Region: Oil and Gas Management Program Manager, 208 West Third Street, Suite 101, Williamsport, PA 17701-6448.

E4129-135: ARD Operating, LLC, 33 West Third Street, Suite 300, Williamsport, PA 17701. Brooks to Plants LP Gathering Pipeline in Cascade Township, Lycoming County, ACOE Baltimore District.

 To construct, operate and maintain approximately 1.1-mile (5,575 LF) of one (1) 8-inch diameter flex steel natural gas pipeline in Cascade Township, Lycoming County. The pipeline will be placed via open cut trenching within the proposed 50 ft ROW. The purpose of this project is to provide a conveyance of low-pressure natural gas between the existing Frymire, McNamee & Nelson pipeline along Kellyburg Road & Plants Evergreen Farms Pad A.

 The project will result in a total of 66 LF (125 SF) of permanent and 348 LF (1,984 SF) of temporary stream impacts, 1,612 SF (0.0370 acre) of permanent and 22,687 SF (5,208 acres) of temporary floodway impacts and 299 SF (0.0069 acre) of permanent and 3,184 SF (0.0731 acre) of temporary wetland impacts all for the purpose of constructing a natural gas pipeline for Marcellus well development.


Stream Impact Table:

Resource
Name
Munic. Quadrangle Activity Chapter 93 Listed Trout Impact Area Temp. (SF) Impact Length Temp. (LF) Impact Area Perm. (SF) Impact Length Perm. (LF) Lat.
Long.
West Branch Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 24 895 23 69 41.442758° 76.868804°
UNT 1— WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 49 252 6 18 41.440679° 76.869084°
UNT 2— WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 24 199 8 24 41.440660° 76.869084°
UNT 5— WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 136 371 41.440276° 76.869407°
UNT 6— WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 64 128 41.440106° 76.869799°
UNT 7— WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 51 139 29 14 41.439940° 76.869977°
TOTAL IMPACTS
348 1,984 66 125
TOTAL STREAM IMPACTS
73 1,147 29 87
TOTAL WAIVER 2 IMPACTS
275 837 37 38

Wetland Impact Table:

Resource
Name
Munic. Quadrangle Activity Cowardin Class Listed Trout Total Impact Area Temp. (SF) Impact Length Temp. (LF) Total Impact Area Perm. (SF) Impact Length Perm. (LF) Lat.
Long.
Wetland 1 Cascade Barbours 8-inch Pipeline Temp. Workspace PEM; EV Wild 68 863 49 151 41.443784° 76.868022°
Wetland 2 Cascade Barbours 8-inch Pipeline Temp. Workspace PEM; EV Wild 34 552 12 35 41.442916° 76.868660°
Wetland 4 Cascade Barbours 8-inch Pipeline Temp. Workspace PEM; EV Wild 75 1,397 33 75 41.441071° 76.869020°
Wetland 5 Cascade Barbours 8-inch Pipeline Temp. Workspace PEM; EV Wild 30 372 13 38 41.439921° 76.870006°
TOTAL IMPACTS
207 3,184 107 299
PEM
207 3,184 107 299
PSS
PFO

Floodway Impact Table:

Resource
Name
Munic. Quadrangle Activity Impact
Area
Temp.
(SF)
Impact Length
Temp.
(LF)
Impact
Area
Perm.
(SF)
Impact Length
Perm.
(LF)
Lat.
Long.
West Branch Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace 100 4,369 100 324 41.442758° 76.868804°
UNT 1—WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace 101 4,756 101 283 41.440679° 76.869084°
UNT 2—WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace 100 1,673 100 77 41.440660° 76.869084°
UNT 5—WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace 135 5,601 135 503 41.440276° 76.869407°
UNT 6—WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace 88 4,117 64 272 41.440106° 76.869799°
UNT 7—WB Wallis Run Cascade Barbours 8-inch Pipeline Temp. Workspace 47 2,171 47 153 41.439940° 76.869977°
TOTAL IMPACTS
571 22,687 547 1,612

E4129-116: Pennsylvania General Energy Co., LLC, 120 Market Street, Warren, PA 16365. Major Modification—Shawnee Pipeline in Plunketts Creek and Upper Fairfield Township, Lycoming County, ACOE Baltimore District.

 To construct, operate and maintain approximately 2.9-miles (15,292 ft) of one (1) 16-inch diameter flex steel natural gas pipeline in Cascade Township, Lycoming County. This project consists of an existing 8-inch natural gas pipeline to be replaced with a new 16-inch natural gas pipeline. The pipeline will be placed via open cut trenching within the existing 35` permanent ROW. The purpose of this project is to provide a conveyance of low-pressure natural gas between the ETP meter site to COP Tract 726 Pad B.

 The project will result in a total of 23 LF (86 SF) of permanent and 86 LF (932 SF) of temporary stream impacts, 711 SF (0.0163 acre) of permanent and 13,449 SF (0.3088 acre) of temporary floodway impacts and 275 SF (0.0063 acre) of temporary wetland impacts all for the purpose of constructing a natural gas pipeline for Marcellus well development.

Stream Impact Table:

Resource
Name
Munic. Quadrangle Activity Chapter 93 Listed Trout Impact Area Temp. (SF) Impact Length Temp. (LF) Impact Area Perm. (SF) Impact Length Perm. (LF) Lat.
Long.
UNT 4 Kaiser Hollow Plunketts Crk. Huntersville 16-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 65 405 8 23 41.325149° 76.866827°
Kaiser Hollow Plunketts Crk. Huntersville 16-inch Pipeline Temp. Workspace HQ-CWF; EV Wild 21 527 15 63 41.328617° 76.863805°
TOTAL IMPACTS
86 932 23 86
TOTAL STREAM IMPACTS
86 932 23 86
TOTAL WAIVER 2 IMPACTS

Wetland Impact Table:

Resource
Name
Munic. Quadrangle Activity Cowardin Class Listed Trout Total Impact Area Temp. (SF) Impact Length Temp. (LF) Total Impact Area Perm. (SF) Impact Length Perm. (LF) Lat.
Long.
Wetland 3 Plunketts Crk. Huntersville 16-inch Pipeline Temp. Workspace PEM; EV Wild 34 275 41.341412° 76.849076°
TOTAL IMPACTS
34 275
PEM
34 275
PSS
PFO

Floodway Impact Table:

Resource
Name
Munic. Quadrangle Activity Impact
Area
Temp.
(SF)
Impact Length
Temp.
(LF)
Impact
Area
Perm.
(SF)
Impact Length
Perm.
(LF)
Lat.
Long.
UNT 4 Kaiser Hollow Plunketts Crk. Huntersville 16-inch Pipeline Temp. Workspace 137 6,911 137 327 41.325149° 76.866827°
Kaiser Hollow Plunketts Crk. Huntersville 16-inch Pipeline Temp. Workspace 128 6,538 128 384 41.328617° 76.863805°
TOTAL IMPACTS
265 13,449 265 711

Permit No. E5829-150, Williams Field Services Company, LLC, Park Place Corporate Center 2, 2000 Commerce Drive, Pittsburgh, PA 15275, Natural Gas Pipeline Access Road. Gibson Township, Susquehanna County; ACOE, Baltimore Office.

 To construct, operate, and maintain:

 1) a permanent access road fill impact of 850 square feet (0.02 acre) to an agricultural Palustrine Emergent Wetland (PEM) (Harford, PA Quadrangle; Latitude: 41° 45` 12", Longitude: -75° 38` 32").

 2) temporary ancillary construction impacts to 376 square feet (0.01 acre) of a Palustrine Emergent Wetland (PEM) (Harford, PA Quadrangle; Latitude: 41° 45` 12", Longitude: -75° 38` 32").

 The project consists of installing 0.4 mile of permanent access road to provide permanent operational access to the Columbia-Davis Pipelines interconnect valve site in Gibson Township, Susquehanna County. The project will result in 1,226 square feet (0.03 acre) of impacts to a Palustrine Emergent Wetland (PEM) located within agricultural lands.

[Continued on next Web Page]



No part of the information on this site may be reproduced for profit or sold for profit.

This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.