NOTICES
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Applications, Actions and Special Notices
APPLICATIONS
[51 Pa.B. 7347]
[Saturday, November 27, 2021]
THE PENNSYLVANIA CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT
APPLICATIONS FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS UNDER THE CLEAN STREAMS LAW AND FEDERAL CLEAN WATER ACT This notice provides information about persons who have applied to the Department of Environmental Protection (DEP) for a new, renewed, or amended NPDES or WQM permit, or a permit waiver for certain stormwater discharges, or have submitted a Notice of Intent (NOI) for coverage under a General Permit. The applications and NOIs concern, but are not limited to, effluent discharges from sewage treatment facilities and industrial facilities to surface waters or groundwater; stormwater discharges associated with industrial activity (industrial stormwater), construction activity (construction stormwater), and municipal separate storm sewer systems (MS4s); the application of pesticides; the operation of Concentrated Animal Feeding Operations (CAFOs); and the construction of sewage, industrial waste, and manure storage, collection and treatment facilities. This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92a and 40 CFR Part 122, implementing The Clean Streams Law (35 P.S. §§ 691.1—691.1001) and the Federal Clean Water Act (33 U.S.C.A. §§ 1251—1376). More information on the types of NPDES and WQM permits that are available can be found on DEP's website (visit www.dep.pa.gov and select Businesses, Water, Bureau of Clean Water, Wastewater Management, and NPDES and WQM Permitting Programs).
Section Category I Individual and General WQM Permit Applications/NOIs Received, General NPDES Permit NOIs Received, and All Transfer and Minor Amendment Applications/NOIs Received II Individual NPDES Permits—New, Renewal, and Major Amendment Applications and Draft Permits for Discharges Relating to Sewage, Industrial Waste, Industrial Stormwater, MS4s, Pesticides and CAFOs III Individual NPDES Permit Applications for Discharges of Stormwater Associated with Construction Activity Section I identifies the following applications and NOIs that have been received by DEP:
• Individual and General WQM Permit Applications Received—DEP provides a 15-day public comment period for Individual WQM Permit Applications for new and reissued permits. There is no public comment period for General WQM Permit NOIs.
• General NPDES Permit NOIs Received—There is no public comment period for General NPDES NOIs received.
• All Transfer and Minor Amendment Applications/NOIs Received—Transfer and Minor Amendment Applications/NOIs received for Individual and General WQM Permits and Individual and General NPDES Permits are identified but do not have public comment periods. DEP provides a 15-day public comment period for Individual WQM Permit Applications for amendments.
Additional information on these applications and NOIs may be reviewed by generating the ''Applications and NOIs without Comment Periods Report'' or, for Individual WQM Permit Applications, the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice.
Section II identifies individual NPDES permit applications received and draft permits issued by DEP relating to sewage, industrial waste, industrial stormwater, MS4s, pesticides and CAFOs. A 30-day public comment period applies to these applications, except when a site-specific water quality criterion is used to establish effluent limitations, in which case a 45-day public comment period applies. The period for comment may be extended at the discretion of the Department for one additional 15-day period. Additional information, including links to draft permits and fact sheets that explain the basis for DEP's tentative determinations may be reviewed by generating the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice. Notification of 15-day extensions for comment will be provided in the ''Applications Received with Comment Periods Report'' (Comments column).
Section III provides notice of applications and draft individual permits for stormwater discharges associated with construction activities. Where indicated, DEP has made tentative determinations, based on preliminary review, to issue permits subject to proposed effluent limitations consisting of best management practices identified in the erosion and sediment control (E&S) plans and post-construction stormwater management (PCSM) plans submitted with the applications, as well as other terms and conditions based on the permit applications. A 30-day public comment period applies to these applications.
Applications and NOIs may be reviewed at the DEP office that received the application or NOI. Contact information for each DEP office for Sections I & II is listed as follows. Contact information for Section III is available within the table. Members of the public are encouraged to use DEP's website to obtain additional information as discussed previously.
Comments received within the appropriate comment periods for WQM and NPDES permit applications will be retained by DEP and considered in the final determinations regarding the applications. A comment submittal should include the name, address and telephone number of the writer and a concise statement to inform DEP of the exact basis of a comment and the relevant facts upon which it is based.
DEP office contact information to review applications and NOIs in Sections I & II and to submit comments for those application and NOIs, when applicable, is as follows:
DEP Southeast Regional Office (SERO)—2 E. Main Street, Norristown, PA 19401-4915. File Review Coordinator: 484.250.5910. Email: RA-EPNPDES_SERO@pa.gov.
DEP Northeast Regional Office (NERO)—2 Public Square, Wilkes-Barre, PA 18701-1915. File Review Coordinator: 570.826.5472. Email: RA-EPNPDES_NERO@pa.gov.
DEP Southcentral Regional Office (SCRO)—909 Elmerton Avenue, Harrisburg, PA 17110. File Review Coordinator: 717.705.4732. Email: RA-EPNPDES_SCRO@pa.gov.
DEP Northcentral Regional Office (NCRO)—208 W. Third Street, Suite 101, Williamsport, PA 17701. File Review Coordinator: 570.327.3693. Email: RA-EPNPDES_NCRO@pa.gov.
DEP Southwest Regional Office (SWRO)—400 Waterfront Drive, Pittsburgh, PA 15222. File Review Coordinator: 412.442.4286. Email: RA-EPNPDES_SWRO@pa.gov.
DEP Northwest Regional Office (NWRO)—230 Chestnut Street, Meadville, PA 16335. File Review Coordinator: 814.332.6340. Email: RA-EPNPDES_NWRO@pa.gov.
DEP Bureau of Clean Water (BCW)—400 Market Street, Harrisburg, PA 17105. File Review Coordinator: 717.787.5017. Email: RA-EPNPDES_Permits@pa.gov.
DEP will also accept requests or petitions for public hearings on applications. The request or petition must indicate the interest of the party filing and the reasons why a hearing is warranted. A hearing will be held if the Department determines that there is a significant public interest. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. DEP will postpone its final determination until after a public hearing is held.
Persons with a disability who require an auxiliary aid, service, including TDD users, or other accommodations to seek additional information should contact the Department through the Pennsylvania Hamilton Relay Service at (800) 654-5984.
I. Individual and General WQM Permit Applications/NOIs Received, General NPDES Permit NOIs Received, and All Transfer and Minor Amendment Applications/NOIs Received.
Application Number Permit Type Application Type Applicant Name & Address Municipality, County DEP Office 6021201 Manure Storage and Wastewater Impoundments Individual WQM Permit New Am Logging, LLC
116 Thompson Lane
Millheim, PA 16854-9617Buffalo Township
Union CountyNCRO 2269206 Minor and Non-NPDES Industrial Waste Treatment Facility Individual WQM Permit Transfer Cleveland Cliffs Steelton, LLC
215 S Front Street
Steelton, PA 17113-2538Steelton Borough
Dauphin CountySCRO 4569403 Minor and Non-NPDES Sewage Treatment Facility Individual WQM Permit Amendment Barton Court MHC, LLC
1199 Lancaster Avenue
Suite 100
Berwyn, PA 19312-1341Pocono Township
Monroe CountyNERO NOEXNW164 No Exposure Certification Renewal Corry Fabrication, LLC
21 Maple Avenue
Corry, PA 16407-1630Corry City
Erie CountyNWRO NOEXSE109 No Exposure Certification Transfer GXO Warehouse Co. Inc.
2201 Green Lane
Levittown, PA 19057Bristol Township
Bucks CountySERO NOEXSE127 No Exposure Certification Renewal Exelon Generation Co. LLC
1 Industrial Highway
Eddystone, PA 19022-1524Philadelphia City
Philadelphia CountySERO PAG030060 PAG-03 NPDES General Permit for Industrial Stormwater Amendment Mazza Iron & Steel, LLC
60 Solar Drive
Fairless Hills, PA 19030Falls Township
Bucks CountySERO PAR116101 PAG-03 NPDES General Permit for Industrial Stormwater Transfer Hitachi Energy USA Inc.
231 Theobold Avenue
Greensburg, PA 15601-5535Greensburg City
Westmoreland CountySWRO PAR116127 PAG-03 NPDES General Permit for Industrial Stormwater Transfer Hitachi Energy USA Inc.
100 Distribution Circle
Mt Pleasant, PA 15666-1044East Huntingdon Township
Westmoreland CountySWRO PAG049245 PAG-04 NPDES General Permit for Small Flow Treatment Facilities Transfer Conway Carol
8350 Clair Wright Road
Girard, PA 16417-7942Franklin Township
Erie CountyNWRO PAG123880 PAG-12 NPDES General Permit for CAFOs Amendment Runk Dallas W
2823 Farm House Lane
James Creek, PA 16657Lincoln Township
Huntingdon CountySCRO PA0232734 Single Residence STP
Individual NPDES PermitTransfer Shaffer Alicia E
794 E Ridge Road
Sunbury, PA 17801-5219Lower Augusta Township
Northumberland CountyNCRO 4916401 Single Residence Sewage Treatment Plant
Individual WQM PermitTransfer Shaffer Alicia E
794 E Ridge Road
Sunbury, PA 17801-5219Lower Augusta Township
Northumberland CountyNCRO PA0288543 Small Flow Treatment Facility Individual NPDES Permit Transfer Bruno Viola K
331 Hannahstown Road
Cabot, PA 16023-2203Jefferson Township
Butler CountyNWRO 1020410 Small Flow Treatment Facility Individual WQM Permit Transfer Bruno Viola K
331 Hannahstown Road
Cabot, PA 16023-2203Jefferson Township
Butler CountyNWRO 3321401 Small Flow Treatment Facility Individual WQM Permit New PTV 1129 LLC
400 Penn Center Boulevard
Bldg 4, Suite 1000
Pittsburgh, PA 15235-5613Winslow Township
Jefferson CountyNWRO WQG018456 WQG-01 WQM General Permit Transfer Conway Carol
8350 Clair Wright Road
Girard, PA 16417-7942Franklin Township
Erie CountyNWRO 2182101 WQG-02 WQM General Permit New Flemington Borough
Clinton County
126 High Street
Lock Haven, PA 17745-3772Flemington Borough
Clinton CountyNCRO WQG02022103 WQG-02 WQM General Permit New North Versailles Township Sanitary Authority
3300 Preble Avenue
Pittsburgh, PA 15233-1025Pittsburgh City
Allegheny CountySWRO WQG02022104 WQG-02 WQM General Permit New North Versailles Township Sanitary Authority
3300 Preble Avenue
Pittsburgh, PA 15233-1025Pittsburgh City
Allegheny CountySWRO
II. Individual NPDES Permits—New, Renewal, and Major Amendment Applications and Draft Permits for Discharges Relating to Sewage, Industrial Waste, Industrial Stormwater, MS4s, Pesticides and CAFOs.
Northwest Regional Office
PA0100838, Industrial, SIC Code 4941, Barkeyville Municipal Authority, 1610 Barkeyville Road, Grove City, PA 16127-7904. Facility Name: Barkeyville Borough WTP. This existing facility is located in Barkeyville Borough, Venango County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial waste.
The receiving stream, an Unnamed Tributary to the North Branch Slippery Rock Creek (CWF), is located in State Water Plan watershed 20-C and is classified for Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.0134 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Daily MinXXX 9.0 XXX Total Residual Chlorine (TRC)
Interim
XXX XXX XXX 1.0 XXX 2.3 Final XXX XXX XXX 0.5 XXX 1.6 Total Suspended Solids XXX XXX XXX 30 60 75 Aluminum, Total XXX XXX XXX 4.0 8.0 10 Iron, Total XXX XXX XXX 2.0 4.0 5 Manganese, Total XXX XXX XXX 1.0 2.0 2.5 In addition, the permit contains the following major special conditions:
• Compliance Schedule for Total Residual Chlorine (TRC)
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 814-332-6078.
The EPA Waiver is in effect.
PA0272825, Industrial, SIC Code 4941, Slippery Rock Municipal Authority, P.O. Box 157, Slippery Rock, PA 16057-0157. Facility Name: Slippery Rock Borough WTP. This existing facility is located in Slippery Rock Township, Butler County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial waste.
The receiving stream, an Unnamed Tributary to the Wolf Creek (CWF), is located in State Water Plan watershed 20-C and is classified for Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.0087 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Total Suspended Solids XXX XXX XXX 30.0 60.0 75 Total Dissolved Solids Report XXX XXX Report Report XXX Total Dissolved Solids XXX 5,000
Annl AvgXXX XXX XXX XXX Aluminum, Total XXX XXX XXX 4.0 8.0 10 Iron, Total XXX XXX XXX 2.0 4.0 5 Manganese, Total XXX XXX XXX 1.0 2.0 2.5 In addition, the permit contains the following major special conditions:
• Chemical Additives
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 814-332-6078.
The EPA Waiver is in effect.
PA0041831, Sewage, SIC Code 4952, Northwest Crawford County Sewer Authority, P.O. Box 56, Springboro, PA 16435-0056. Facility Name: Northwest Crawford County Sewer Authority STP. This existing facility is located in Springboro Borough, Crawford County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream, the Conneaut Creek (WWF, MF), is located in State Water Plan watershed 15-A and is classified for Migratory Fishes and Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.6 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageMinimum Average Monthly Weekly
AverageIMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Dissolved Oxygen XXX XXX 4.0
Inst MinXXX XXX XXX Total Residual Chlorine (TRC) XXX XXX XXX 0.3 XXX 1.0 Carbonaceous Biochemical
Oxygen Demand (CBOD5)100.0 150.0 XXX 20.0 30.0 40 Biochemical Oxygen
Demand (BOD5)
Raw Sewage InfluentXXX XXX XXX Report XXX XXX Total Suspended Solids 150.0 225.0 XXX 30.0 45.0 60 Raw Sewage Influent XXX XXX XXX Report XXX XXX Fecal Coliform (No./100 ml)
Oct 1 - Apr 30 XXX XXX XXX 2,000
Geo MeanXXX 10,000 May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report Total Nitrogen XXX XXX XXX Report XXX XXX Ammonia-Nitrogen
Nov 1 - Apr 30 105.0 XXX XXX 21.0 XXX 42 May 1 - Oct 31 35.0 XXX XXX 7.0 XXX 14 Total Phosphorus 5.0 XXX XXX 1.0 XXX 2 In addition, the permit contains the following major special conditions:
• Solids Management
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 814-332-6078.
The EPA Waiver is in effect.
PA0222925, Sewage, SIC Code, Kenneth E. White, 2275 W Washington Street, Bradford, PA 16701-2412. Facility Name: Kenneth E. White SRSTP. This existing facility is located in Corydon Township, McKean County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated SRSTP sewage.
The receiving stream(s), Willow Creek, is located in State Water Plan watershed 16B and is classified HQ-CWF for aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of .0004 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Annual
AverageMaximum IMAX Flow (GPD) Report
Annl AvgXXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Total Residual Chlorine (TRC) XXX XXX XXX 0.5
Avg MoXXX 1.4 Biochemical Oxygen
Demand (BOD5)XXX XXX XXX 10.0 XXX 20 Total Suspended Solids XXX XXX XXX 10.0 XXX 20 Fecal Coliform (No./100 ml) XXX XXX XXX 200 XXX 1,000 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 814-332-6078.
The EPA Waiver is in effect.
Southeast Regional Office
PA0011436, Industrial, SIC Code 3317, Handy & Harman Tube Co. Inc., 590 Madison Avenue, New York, NY 10022. Facility Name: Handy & Harman Tube Norristown facility. This existing facility is located in East Norriton Township, Montgomery County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated groundwater.
The receiving stream(s), Unnamed Tributary to Stony Creek (TSF), is located in State Water Plan watershed 3-F and is classified for Trout Stocking, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of .016 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX Flow (MGD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Chloroform XXX XXX XXX 0.086 XXX 0.22 Tetrachloroethylene XXX XXX XXX 0.01 XXX 0.025 Trichloroethylene XXX XXX XXX 0.0097 XXX 0.024 Trichloroethylene
Industrial InfluentXXX XXX XXX Report XXX XXX In addition, the permit contains the following major special conditions:
I. Other Requirements
A. Property Rights
B. Sludges Disposal
C. WQM Permit
II. Groundwater Cleanup
A. BAT and BCT
B. No Discharge of Stripper Cleaning
C. Twice a Month Visual Inspection
D. Safety/Alarm System
E. Reports to ECP
F. Weekly Sampling
G. Quality of the Operation
H. Monitoring Effectiveness
I. Cleanup Operation
J. Notification about Shutdown
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is in effect.
PA0245321, Sewage, SIC Code 4952, Miller Amanda L, 170 Short Road, Doylestown, PA 18901-3217. Facility Name: 170 Short Rd SRSTP. This proposed facility is located in Doylestown Township, Bucks County.
Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated SRSTP sewage.
The receiving stream(s), Unnamed Tributary of Neshaminy Creek (TSF, MF), is located in State Water Plan watershed and is classified for Migratory Fishes and Trout Stocking, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of .0005 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Inst.
MinimumAnnual
AverageMaximum IMAX Flow (MGD) Report
Annl AvgXXX XXX XXX XXX XXX pH (S.U.) XXX XXX
6.0XXX XXX 9.0 Carbonaceous Biochemical
Oxygen Demand (CBOD5)XXX XXX XXX 10.0 XXX 20 Total Suspended Solids XXX XXX XXX 10.0 XXX 20 Fecal Coliform (No./100 ml) XXX XXX XXX 200 XXX XXX In addition, the permit contains the following major special conditions:
A. AMR Submission
B. DMR Submission
C. Depth of Septage
D. Pumping of Septage Tank
E. TRC Minimization
F. No Stormwater
G. Property Rights
H. Sludge Removal
I. Abandon Use and Decommission
J. UV Proper Cleaning
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is in effect.
Southwest Regional Office
PA0217158, Industrial, SIC Code 4941, 4952, The Authority of the Borough of Charleroi, P.O. Box 211, Charleroi, PA 15022-0211. Facility Name: Charleroi Water Filtration Plant. This existing facility is located in Charleroi Borough, Washington County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated water treatment plant backwash water and flocculator wastewater.
The receiving stream(s), Monongahela River (WWF), is located in State Water Plan watershed and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.293 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumDaily
MinimumAverage Monthly Daily
MaximumIMAX Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine (TRC) XXX XXX XXX 0.5 1.0 XXX Total Suspended Solids XXX XXX XXX 30.0 60.0 XXX Aluminum, Total XXX XXX XXX 4.0 8.0 XXX Iron, Total XXX XXX XXX 2.0 4.0 XXX Manganese, Total XXX XXX XXX 1.0 2.0 XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is in effect.
PA0042102, Storm Water, SIC Code 2851, Huntsman Advanced Materials Americas, LLC, 10003 Woodloch Forest Drive, The Woodlands, TX 77380-1913. Facility Name: Huntsman Advanced Materials Americas, LLC. This existing facility is located in Manor Borough, Westmoreland County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial stormwater from a manufacturing facility.
The receiving stream(s), Bushy Run (TSF), is located in State Water Plan watershed 19-A and is classified for Trout Stocking, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumIMAX Flow (MGD) XXX Report XXX XXX XXX XXX pH (S.U.) XXX XXX XXX XXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Nitrate-Nitrite as N XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX Lead, Total XXX XXX XXX XXX Report XXX Zinc, Total XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 002 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumIMAX Flow (MGD) XXX Report XXX XXX XXX XXX pH (S.U.) XXX XXX XXX XXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Nitrate-Nitrite as N XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX Lead, Total XXX XXX XXX XXX Report XXX Zinc, Total XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 003 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumIMAX Flow (MGD) XXX Report XXX XXX XXX XXX pH (S.U.) XXX XXX XXX XXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Nitrate-Nitrite as N XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX Lead, Total XXX XXX XXX XXX Report XXX Zinc, Total XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 005 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumIMAX Flow (MGD) XXX Report XXX XXX XXX XXX pH (S.U.) XXX XXX XXX XXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Nitrate-Nitrite as N XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX Lead, Total XXX XXX XXX XXX Report XXX Zinc, Total XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 006 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumIMAX Flow (MGD) XXX Report XXX XXX XXX XXX pH (S.U.) XXX XXX XXX XXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Nitrate-Nitrite as N XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX Lead, Total XXX XXX XXX XXX Report XXX Zinc, Total XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 007 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumIMAX Flow (MGD) XXX Report XXX XXX XXX XXX pH (S.U.) XXX XXX XXX XXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Nitrate-Nitrite as N XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX Lead, Total XXX XXX XXX XXX Report XXX Zinc, Total XXX XXX XXX XXX Report XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is in effect.
PA0005037, Industrial, SIC Code 4911, NRG Homer City Services, LLC, 1750 Power Plant Road, Homer City, PA 15748. Facility Name: Homer City Generating Station and Homer City Coal Cleaning Plant. This existing facility is located in Center Township, Indiana County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for existing discharges of treated industrial waste and storm water. This is a revision to draft limits published on September 4, 2021.
The receiving streams, Unnamed Tributary to Two Lick Creek (CWF), Unnamed Tributary of Blacklick Creek (CWF), Blacklick Creek (TSF), Two Lick Creek (TSF), Unnamed Tributary of Two Lick Creek (CWF), Unnamed Tributary to Blacklick Creek (CWF), Cherry Run (CWF), and Unnamed Tributary to Muddy Run (CWF), are located in State Water Plan watershed 18-D and are classified for Cold Water Fishes and Trout Stocking, aquatic life, water supply and recreation. The discharges are not expected to affect public water supplies.
The proposed effluent limits for Outfall 027 are based on a design flow of 0.14 MGD.—Interim Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Total Monthly Instant. Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Temperature (°F) XXX XXX XXX XXX XXX 110 Carbonaceous Biochemical
Oxygen Demand (CBOD5)XXX XXX XXX 25.0 50.0 XXX Total Suspended Solids XXX XXX XXX 30.0 100.0 XXX Total Dissolved Solids XXX XXX XXX Report Report XXX Osmotic Pressure (mOs/kg) XXX XXX XXX Report Report XXX Oil and Grease XXX XXX XXX 15.0 20.0 30 Nitrate-Nitrite as N XXX XXX XXX Report Report XXX Aluminum, Total XXX XXX XXX Report Report XXX Total Aluminum
(Total Load, lbs)XXX Report XXX XXX XXX XXX Total Aluminum
(Total Load, lbs)XXX Report
Total
AnnualXXX XXX XXX XXX Arsenic, Total XXX XXX XXX Report Report XXX Beryllium, Total XXX XXX XXX 0.8 1.6 XXX Boron, Total XXX XXX XXX Report Report XXX Cyanide, Free XXX XXX XXX Report Report XXX Iron, Total XXX XXX XXX Report Report XXX Total Iron
(Total Load, lbs)XXX Report XXX XXX XXX XXX Total Iron
(Total Load, lbs)XXX Report
Total
AnnualXXX XXX XXX XXX Lead, Total XXX XXX XXX 0.1 0.2 XXX Manganese, Total XXX XXX XXX Report Report XXX Total Manganese
(Total Load, lbs)XXX Report XXX XXX XXX XXX Total Manganese
(Total Load, lbs)XXX Report
Total
AnnualXXX XXX XXX XXX Mercury, Total (ng/L) XXX XXX XXX Report Report XXX Selenium, Total XXX XXX XXX 0.8 1.6 XXX Bromide XXX XXX XXX Report Report XXX MBAS XXX XXX XXX Report Report XXX The proposed effluent limits for Outfall 027 are based on a design flow of 0.14 MGD.—Final Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Total Monthly Instant. Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Temperature (°F) XXX XXX XXX XXX XXX 110 Carbonaceous Biochemical
Oxygen Demand (CBOD5)XXX XXX XXX 25.0 50.0 XXX Total Suspended Solids XXX XXX XXX 30.0 100.0 XXX Total Dissolved Solids XXX XXX XXX 149.0 306.0 XXX Osmotic Pressure (mOs/kg) XXX XXX XXX Report Report XXX Oil and Grease XXX XXX XXX 15.0 20.0 30 Nitrate-Nitrite as N XXX XXX XXX 1.2 2.0 XXX Aluminum, Total XXX XXX XXX 0.75 0.75 0.75 Total Aluminum
(Total Load, lbs)XXX Report XXX XXX XXX XXX Total Aluminum
(Total Load, lbs)XXX 4,045
Total
AnnualXXX XXX XXX XXX Arsenic, Total XXX XXX XXX Report 0.005 XXX Beryllium, Total XXX XXX XXX 0.8 1.6 XXX Boron, Total XXX XXX XXX 217.0 339.0 542.5 Cyanide, Free XXX XXX XXX 0.59 0.92 1.48 Iron, Total XXX XXX XXX 1.5 3.0 3.75 Total Iron
(Total Load, lbs)XXX Report XXX XXX XXX XXX Total Iron
(Total Load, lbs)XXX 8,091
Total
AnnualXXX XXX XXX XXX Lead, Total XXX XXX XXX 0.1 0.2 XXX Manganese, Total XXX XXX XXX 1.0 2.0 2.5 Total Manganese
(Total Load, lbs)XXX Report XXX XXX XXX XXX Total Manganese
(Total Load, lbs)XXX 5,395
Total
AnnualXXX XXX XXX XXX Mercury, Total (ng/L) XXX XXX XXX 10.0 23.0 XXX Selenium, Total XXX XXX XXX Report 0.010 XXX Bromide XXX XXX XXX Report 0.2 XXX MBAS XXX XXX XXX Report Report XXX In addition, the permit contains the following revisions to major special conditions: The schedule of compliance for total annual load limits at Outfall 027 is revised from 36 months to 59 months with milestones that coincide with the previously drafted schedule of compliance for other new limits at that outfall. Cooling water intake structure requirements imposed pursuant to Section 316(b) of the Clean Water Act are updated to require daily monitoring and monthly reporting of actual intake flows, cooling water withdrawals, make-up water, and blowdown volume. The calculation procedures are clarified for total monthly and total annual loads at Outfalls 001, 018, and 027. The dates of interim milestones for the schedule of compliance for TMDL limits at Outfalls 006, 013, and 021 are modified.
The effluent limits and monitoring requirements for all other Internal Monitoring Points and Outfalls are unchanged.
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is not in effect.
PA0252638, Sewage, SIC Code 4952, Perry Township Municipal Authority, P.O. Box 306, Star Junction, PA 15482-0306. Facility Name: Perry Township Municipal Authority STP. This existing facility is located in Perry Township, Fayette County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Youghiogheny River, is located in State Water Plan watershed 19-D and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.1 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageMinimum Average Monthly Weekly
AverageIMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Daily MinXXX 9.0
Daily MaxXXX Dissolved Oxygen XXX XXX 4.0
Daily MinXXX XXX XXX Carbonaceous Biochemical
Oxygen Demand (CBOD5)20.9 31.3 XXX 25 37.5 50 Biochemical Oxygen
Demand (BOD5)—InfluentReport Report
Daily MaxXXX Report XXX XXX Total Suspended Solids 25.0 37.6 XXX 30 45 60 Total Suspended Solids—Influent Report Report
Daily MaxXXX Report XXX XXX Fecal Coliform (No./100 ml)
Oct 1 - Apr 30 XXX XXX XXX 2,000
Geo MeanXXX 10,000 May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report Ultraviolet light transmittance (%) XXX XXX XXX Report Report XXX Ammonia-Nitrogen Report XXX XXX Report XXX XXX Total Nitrogen XXX XXX XXX Report
Daily MaxXXX XXX Total Phosphorus XXX XXX XXX Report
Daily MaxXXX XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is in effect.
Northcentral Regional Office
PA0232874 A-1, Storm Water, SIC Code 5169, American Rock Salt Company, LLC, P.O. Box 190, Mount Morris, NY 14510-0190. Facility Name: DuBois Salt Storage Facility. This existing facility is located in Sandy Township, Clearfield County.
Description of Existing Activity: The application is to amend an NPDES permit for an existing discharge of treated industrial stormwater.
The receiving stream(s), Unnamed Tributary to Sandy Lick Creek, is located in State Water Plan watershed 17-C and is classified for Trout Stocking (TSF), aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed monitoring requirements for Outfall 001 are:
Mass Units (lbs/day) Concentrations (mg/L) Parameters Total Monthly Daily
MaximumMinimum Average Monthly Maximum IMAX Total Flow
(Total Volume, Mgal) (M Gal)Report Report XXX XXX XXX XXX Rainfall (In) Report Report XXX XXX XXX XXX The proposed monitoring requirements for IMP 102 are:
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Inst.
MinimumDaily
MaximumMaximum IMAX pH (S.U.) XXX XXX Report Report XXX XXX Total Suspended Solids XXX XXX XXX Report XXX XXX Total Dissolved Solids XXX XXX XXX Report XXX XXX Cyanide, Free (ug/L) XXX XXX XXX Report XXX XXX Chloride XXX XXX XXX Report XXX XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.
The EPA Waiver is in effect.
PA0112275, Industrial, SIC Code 3274, Con-Lime, Inc., 375 Graymont Road, Bellefonte, PA 16823-6869. Facility Name: Con Lime Bellefonte Facility. This existing facility is located in Benner Township, Centre County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial waste.
The receiving stream(s), Buffalo Run, is located in State Water Plan watershed 9-C and is classified for High-Quality Cold Water Fishery, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 101 are based on a design flow of 4.1 MGD.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
MaximumIMAX pH (S.U.) XXX XXX Report
Inst MinXXX XXX Report Total Suspended Solids XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 102 are based on a design flow of 0.22 MGD.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
MaximumIMAX pH (S.U.) XXX XXX Report
Inst MinXXX XXX Report Total Suspended Solids XXX XXX XXX XXX Report XXX Aluminum, Total XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 201 are based on a design flow of 0 MGD.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Total Suspended Solids Report Report XXX 30.0 45.0 60 Aluminum, Total Report Report XXX Report Report XXX Iron, Total Report Report XXX Report Report XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.
The EPA Waiver is in effect.
III. Individual NPDES Permit Applications for Discharges of Stormwater Associated with Construction Activity.
Application Number Application Type Applicant Name & Address Municipality, County Office PAD090082 New NP Falls Township
Industrial, LLC
4805 Montgomery Road
Cincinnati, OH 45212-2280Falls Township
Bucks CountySERO PAD150155 A-1 Amend Valley Investments Group VII Tim Townes
120 Pennsylvania Avenue
Malvern, PA 19355Charlestown Township
Chester CountySERO PAD150187 A-1 Amend H&K Group, Inc.
2052 Lucon Road
P.O. Box 196
Skippack, PA 19474-0196City of West Nantmeal
Chester CountySERO PAD070024 New Kulp Family Dairy, LLC
1691 Millerstown Road
Martinsburg, PA 16662North Woodbury Township
Blair CountySCRO PAD360080 New Elmer S. Riehl
468 Redwell Road
New Holland, PA 17557Salisbury Township
Lancaster CountySCRO PAD360074 New Dwayne A. Peifer
235 Academy Road
Kirkwood, PA 17536Colerain Township
Lancaster CountySCRO
PUBLIC WATER SUPPLY PERMITS Under the Pennsylvania Safe Drinking Water Act (35 P.S. §§ 721.1—721.17), the following parties have applied for PWS permits to construct or substantially modify public water systems.
Persons wishing to comment on permit applications are invited to submit statements to the office listed before the application within 30 days of this public notice. Comments received within this 30-day comment period will be considered in the formulation of the final determinations regarding an application. A comment should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.
Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.
The permit application and related documents are on file at the office listed before the application and available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.
Persons with a disability that require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users may contact the Department through the Pennsylvania Hamilton Relay Service at (800) 654-5984.
SAFE DRINKING WATER
Applications Received Under the Pennsylvania Safe Drinking Water Act (35 P.S. §§ 721.1—721.17).
Southeast Region: Safe Drinking Water Program, 2 East Main Street, Norristown, PA 19401, Telephone 484.250.5887.
Contact: Kimberleigh Rivers, Clerk Typist 2, 424.250.5887.
Permit No. 1521521, Public Water Supply.
Applicant Camphill Village
Kimberton Hill, Inc.
P.O. Box 1045
Kimberton, PA 19442Township West Vincent County Chester Responsible Official Mark Ohi
Camphill Village
Kimberton Hill, Inc.
P.O. Box 1045
Kimberton, PA 19442Type of Facility PWS Consulting Engineer Keystone Engineering
Group, Inc.
590 East Lancaster Avenue
Frazer, PA 19355Application Received Date November 10, 2021 Description of Action Installation of nitrate removal system at existing well house facility. Southwest Region: Safe Drinking Water Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.
Permit No. 0221546, Public Water Supply.
Applicant Pittsburgh Water &
Sewer Authority
1200 Penn Avenue
Pittsburgh, PA 15222Township or Borough City of Pittsburgh County Allegheny Responsible Official Barry King
Director of Engineering and ConstructionType of Facility Water system Consulting Engineer Mott MacDonald
Two Allegheny Center
Pittsburgh, PA 15212Application Received Date October 28, 2021 Description of Action Highland Reservoir Pump Station and Rising Main Pump Station project. Permit No. 0221547, Public Water Supply.
Applicant Fawn-Frazer Joint
Water Authority
325 Donnellville Road
Natrona Heights, PA 15065Township or Borough Fawn Township County Allegheny Responsible Official Edward L. Adams
ChairmanType of Facility Water system Consulting Engineer Bankson Engineers, Inc.
267 Blue Run Road
Suite 200
Cheswick, PA 15024Application Received Date October 26, 2021 Description of Action Painting, rehabilitation and installation of a GridBee mixing system at the Route 908 Tank; and installation of a VFD pump drive, including electrical work at the Route 908 Pump Station.
WATER ALLOCATIONS
Applications received under the Act of June 24, 1939 (P.L. 842, No. 365) (35 P.S. §§ 631—641) relating to the Acquisition of Rights to Divert Waters of the Commonwealth.
Northcentral Region: Safe Drinking Water Program, 208 West Third Street, Williamsport, PA 17701.
WA 47-1006B Water Allocations. Suez Water Pennsylvania, Inc., 6310 Allentown Blvd, Suite 104, Harrisburg, PA 17223, Mahoning Township, Montour County. Renewal of the Danville Municipal Authority Interconnect, Water Allocation Permit WA 47-1006A, 1,000,000 (gpd) requested.
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.