NOTICES
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Applications, Actions and Special Notices
APPLICATIONS
[35 Pa.B. 2420]
THE CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT
APPLICATIONS FOR NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS This notice provides information about persons who have applied for a new, amended or renewed NPDES or WQM permit, a permit waiver for certain stormwater discharges or submitted a Notice of Intent (NOI) for coverage under a general permit. The applications concern, but are not limited to, discharges related to industrial, animal or sewage waste, discharges to groundwater, discharges associated with municipal separate storm sewer systems (MS4), stormwater associated with construction activities or concentrated animal feeding operations (CAFOs). This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92 and 40 CFR Part 122, implementing The Clean Streams Law (35 P. S. §§ 691.1--691.1001) and the Federal Clean Water Act.
Location Permit Authority Application Type or Category Section I NPDES Renewals Section II NPDES New or amendment Section III WQM Industrial, sewage or animal waste; discharge into groundwater Section IV NPDES MS4 individual permit Section V NPDES MS4 permit waiver Section VI NPDES Individual permit stormwater construction Section VII NPDES NOI for coverage under NPDES general permits For NPDES renewal applications in Section I, the Department of Environmental Protection (Department) has made a tentative determination to reissue these permits for 5 years subject to effluent limitations and monitoring and reporting requirements in their current permits, with appropriate and necessary updated requirements to reflect new and changed regulations and other requirements.
For applications for new NPDES permits and renewal applications with major changes in Section II, as well as applications for MS4 individual permits and individual stormwater construction permits in Sections IV and VI, the Department, based upon preliminary reviews, has made a tentative determination of proposed effluent limitations and other terms and conditions for the permit applications. These determinations are published as proposed actions for comments prior to taking final actions.
Unless indicated otherwise, the EPA Region III Administrator has waived the right to review or object to proposed NPDES permit actions under the waiver provision in 40 CFR 123.24(d).
Persons wishing to comment on an NPDES application are invited to submit a statement to the regional office noted before an application within 30 days from the date of this public notice. Persons wishing to comment on a WQM permit application are invited to submit a statement to the regional office noted before the application within 15 days from the date of this public notice. Comments received within the respective comment periods will be considered in the final determinations regarding the applications. Comments should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based.
The Department will also accept requests for a public hearing on applications. A public hearing may be held if the responsible office considers the public response significant. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. The Department will postpone its final determination until after a public hearing is held.
Persons with a disability who require an auxiliary aid, service, including TDD users, or other accommodations to seek additional information should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
I. NPDES Renewal Applications
Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.
NPDES No.
(Type)Facility Name and
AddressCounty and
MunicipalityStream Name
(Watershed#)EPA Waived Y/N ? PA0024066 West Grove Borough Authority
P. O. Box 61
117 Rosehill Avenue
West Grove, PA 19390-0061Chester County
London Grove TownshipMiddle Branch White Clay Creek Y
Northeast Region: Water Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.
NPDES No.
(Type)Facility Name and
AddressCounty and
MunicipalityStream Name
(Watershed #)EPA Waived Y/N ? PA0061697
Industrial Waste RenewalGilberton Power Company
50 Eleanor Avenue
Frackville, PA 17931-2301West Mahanoy Township,
Schuylkill CountyMahanoy Creek
06BY PA0030139
Sewage Minor RenewalDepartment of Corrections
P. O. Box 598
Camp Hill, PA 17001-0598Jackson Township,
Luzerne CountyEast Fork Harvey's
05B CreekY
Southcentral Region: Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110, (717) 705-4707.
NPDES No.
(Type)Facility Name and
AddressCounty and
MunicipalityStream Name
(Watershed#)EPA Waived Y/N ? PA0088323
(IW)Calpine Construction Finance Company LP Berks County
Ontelaunee TownshipSchuylkill River/3-B Y PA0247723
(SEW-SFR)LeRoy and Mary Musser
1901 Cider Press Road
Manheim, PA 17545Lancaster County
Rapho TownshipUNT Little Chickies Creek/7-G Y
Northcentral Region: Water Management Program Manager, 208 West Third Street, Williamsport, PA 17701.
NPDES No.
(Type)Facility Name and
AddressCounty and
MunicipalityStream Name
(Watershed#)EPA Waived Y/N ? PA0024627 McClure Municipal Authority Snyder County,
McClure BoroughPenns--Middle Creek (6A) Y
Northwest Region: Water Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.
NPDES No.
(Type)Facility Name and
AddressCounty and
MunicipalityStream Name
(Watershed#)EPA Waived Y/N ? PA0002038 OMG Americas
P. O. Box 111
Franklin, PA 16323-0111Sugarcreek Township
Venango CountyRace Run
Allegheny River
Two Mile Run
16-EY
II. Applications for New or Expanded Facility Permits, Renewal of Major Permits and EPA Nonwaived Permit Applications
Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.
PA0244007, Sewage, SIC 562, Edward and Jane Bacon, 1900 Fairview Road, Glenmoore, PA 19343. This proposed facility is located in East Nantmeal Township, Chester County.
Description of Proposed Activity: Issuance of an NPDES permit to discharge 400 gpd of treated sewage into a UNT of Beaver Run from small flow sewage treatment plant.
The receiving stream, a UNT of Beaver Run, is in the State Water Plan watershed 3D-Manatawny and is classified as a HQ stream.
The proposed effluent limits for Outfall 001 are based on a design flow of 400 gpd.
Mass (lb/day)
Concentration (mg/l) Average Maximum Average Maximum Instantaneous
MaximumParameters Monthly Daily Monthly Daily (mg/l) CBOD5 10 20 Total Suspended Solids 10 20 Fecal Coliform 200#/100 ml Total Residual Chlorine Monitor pH 6.0 STU 9.0 STU PA0058556 Amendment No. 1, Industrial Waste, NAICS 221310, Downingtown Municipal Water Authority, 100 Water Plant Way, Downingtown, PA 19335. This proposed facility is located in Downingtown Borough, Chester County.
Description of Proposed Activity: Discharge of filter backwash, clarifier backwash and sludge drying beds filtrate from the sludge thickening/holding tank of the water filtration plant to a UNT to Beaver Creek.
The receiving stream, Beaver Creek, is in the State Water Plan watershed 3H and is classified for: TSF.
The proposed technology based effluent limits for Outfall 001 are based on an annual average flow of 50,000 gpd:
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous
MaximumParameters Monthly Daily Monthly Daily (mg/l) Flow Monitor Monitor Total Suspended Solids 30 60 75 Total Residual Chlorine 0.5 1.0 1.25 Iron, Total 2.0 4.0 5.0 Aluminum, Total 4.0 8.0 10 Manganese, Total 1.0 2.0 2.5 pH (STD) 6.0 min. 9.0 In addition to the effluent limits, the permit contains the following major special conditions:
1. Remedial Measures.
2. BAT/ELG Reopener.
3. TMDL/WLA Analysis.
4. Laboratory Certification.
5. Sludge Disposal.
6. Change of Ownership.PA0243990, Industrial Waste, Hershey Foods Corporation, Pennsburg Plant, 2452 Quakertown Road, Pennsburg, PA 18073. Mailing address for Hershey Foods is: 1025 Reese Avenue, P. O. Box 805, Hershey, PA 17033. This proposed facility is located in Upper Hanover, Montgomery County.
Description of Proposed Activity: This application is for renewal of an NPDES permit to discharge treated process and sanitary wastewater and stormwater runoff from the Pennsburg manufacturing plant to Macoby Creek Branch.
The receiving stream, Macoby Creek Branch, is in the State Water Plan watershed 3E-Perkiomen and is classified for: TSF, aquatic life, water supply and recreation. The nearest downstream public water supply intake for Suburban Water Company located on Perkiomen Creek, approximately 15 miles below the point of discharge.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.02 mgd.
Mass (lb/day)
Concentration (mg/l) Average Maximum Average Maximum Instantaneous
MaximumParameters Monthly Daily Monthly Daily (mg/l) CBOD5 4 8 25 50 62 Total Suspended Solids 3 7 20 40 50 Total Dissolved Solids 167 334 1,000 2,000 2,500 Ammonia as N 0.3 0.7 2 4 5 Phosphorus as P 0.3 0.7 2 4 5 Oil and Grease 15 50 30 Fecal Coliform 200#/100 ml Dissolved Oxygen 5 (Inst. Min) Color, True (Pt/Cobalt scale) 100 pH (STD Unit) Within limits of 6.0 to 9.0 at all times In addition to the effluent limits, the permit contains the following major special conditions:
1. Discharge must not cause nuisance or health hazard.
2. Stormwater outfall monitoring once per year.PA0057380, Sewage, SIC 4952, Steven and Heidi Whitney, 3815 Chatham Place, Media, PA 19063. This proposed facility is located in Upper Providence Township, Delaware County.
Description of Proposed Activity: NPDES Permit renewal for a single residence sewage treatment plant in Upper Providence Township, Delaware County.
The receiving stream, UNT to Ridley Creek, is in the State Water Plan watershed 3G and is classified for: HQ, TSF. The nearest downstream public water supply intake for Media Borough Water Treatment Plant is located on Ridley Creek and is 3.3 miles below the point of discharge.
The proposed effluent limits for Outfall 001 are based on a design flow of 500 gpd.
Average Instantaneous Parameter Monthly (mg/l) Maximum (mg/l) CBOD5 (5-1 to 10-31) 10 20 (11-1 to 4-30) 20 40 Suspended Solids 10 20 Ammonia (as N) (5-1 to 10-31) 1.5 3.0 (11-1 to 4-30) 4.5 9.0 Total Residual Chlorine Monitor and Report Monitor and Report Fecal Coliform 200 colonies/100 ml as a geometric average Dissolved Oxygen minimum of 6.0 mg/l at all times pH Within limits of 6.0 to 9.0 Standard Units at all times In addition to the effluent limits, the permit contains the following Other Requirements:
Other Requirements:
1. AMR to DEP.
2. Abandon STP when Municipal Sewers Available.
3. Remedial Measures if Unsatisfactory Effluent.
4. No Stormwater.
5. Acquire Necessary Property Rights.
6. Dry Swale Discharge.
7. Change in Ownership.
8. Sludge Disposal.
9. Laboratory Certification.
Southcentral Region: Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110, (717) 705-4707.Application No. PA0247634, Sewage, There's Room in the Inn WWTF, 444 Plessinger Road, Warfordsburg, PA 17627. This facility is located in Brush Creek Township, Fulton County.
Description of activity: The application is for issuance of an NPDES permit for new discharge of treated sewage.
The receiving stream, UNT Little Tonoloway Creek, is in Watershed 13-B and classified for CWF, water supply, recreation and fish consumption. The nearest downstream public water supply intake for The R.C. Wilson Water Treatment Plant is located on the Potomac River, approximately 33 miles downstream. The discharge is not expected to affect the water supply.
The proposed effluent limits for Outfall 001 for a design flow of 0.0045 mgd are:
Average Instantaneous Parameter Monthly (mg/l) Maximum (mg/l) CBOD5 25 30 Total Suspended Solids 30 60 Total Residual Chlorine 1.5 2.5 Dissolved Oxygen Minimum of 5.0 at all times pH From 6.0 to 9.0 inclusive
Fecal Coliform (5-1 to 9-30) 200/100 ml as a geometric average (10-1 to 4-30) 200/100 ml as a geometric average Persons may make an appointment to review the Department of Environmental Protection's files on this case by calling the file review coordinator at (717) 705-4732.
The EPA waiver is in effect.
Northcentral Region: Water Management Program Manager, 208 West Third Street, Williamsport, PA 17701 (570) 327 3664.PA0228893, Sewerage SIC, 4952, Liberty Area Municipal Authority, P. O. Box 73, Liberity, PA 16930. This proposed facility is located in Liberty Township, Tioga County.
Description of Proposed Activity: This proposed action is for issuance of an NPDES permit for a proposed discharge of treated sewage wastewater.
The receiving stream, Blockhouse Creek, is in the State Water Plan watershed 9A and classified for: CWF. The nearest downstream public water supply intake for PA American is located on West Branch Susquehanna River, 72 miles below the point of discharge.
The proposed effluent limits for Outfall 001 based on a design flow of 0.06 mgd.
Average Average Daily Instantaneous Parameter Monthly (mg/l) Weekly (mg/l) Maximum (mg/l) Maximum (mg/l) CBOD5 (6-1 to 10-31) 20 30 40 (11-1 to 5-31) 25 40 50 TSS (6-1 to 10-31) 10 15 20 (11-1 to 5-31) 30 45 60 Ammonia-n (6-1 to 10-1) 6 9 12 (11-1 to 5-31) 18 27 36 Total Cl2 Residual Dechlorinate 0.05 Fecal Coliform: (5-1 to 9-30) 200 col/100 ml as a geometric mean
(10-1 to 4-30) 200 col/100 ml as a geometric mean
pH 6.0 to 9.0 at all times Southwest Regional Office: Regional Manager, Water Management, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, (412) 442-4000.
PA0001937-A1, Industrial Waste, SIC, 3612, Cooper Power Systems, Cooper US, 600 Travis, Suite 5800, Houston, TX 77002 and Pennsylvania Transformer Technology, 201 Carolina Drive, Raeford, NC 28376. This application is for amendment of an NPDES permit to discharge treated process water, stormwater, untreated stormwater from Canonsburg Plant in Cecil Township, Washington County.
The following effluent limitations are proposed for discharge to the receiving waters, Chartiers Creek and UNT to Chartiers, classified as a WWF with existing and/or potential uses for aquatic life, water supply and recreation. The first existing/proposed downstream potable water supply is West View Municipal Authority, 210 Perry Highway, Pittsburgh, PA 15229, 33 miles below the discharge point.
Outfall 001: existing discharge, interim effluent limits.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable using EPA Method 608
Oil and Grease Monitor and Report Tetrachloroethylene Monitor and Report Trichloroethylene Monitor and Report Vinyl Chloride Monitor and Report Chlordane Monitor and Report
pH not less than 6.0 nor greater than 9.0 Other Conditions:
Outfall 001: existing discharge, final effluent limits
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608
Oil and Grease Monitor and Report Tetrachloroethylene Monitor and Report Trichloroethylene Monitor and Report Vinyl Chloride Monitor and Report Chlordane Not Detectable Using EPA Method 608 pH not less than 6.0 nor greater than 9.0 Outfall 002: existing discharge, interim effluent limits.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608
Oil and Grease Monitor and Report Arsenic Monitor and Report
Copper Monitor and Report
Selenium Monitor and Report Zinc Monitor and Report
Cyanide free Monitor and Report
total Monitor and Report
Tetrachloroethylene Monitor and Report Trichloroethylene Monitor and Report
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum Vinyl Chloride Monitor and Report
Fecal Coliforms Monitor and Report
Total Suspended Solids Monitor and Report
Chlordane Monitor and Report
trans-1, 2 Dichloroethylene Monitor and Report cis-1, 2 Dichloroethylene Monitor and Report
Chloroform Monitor and Report pH not less than 6.0 nor greater than 9.0 Outfall 102: new discharge.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608
Oil and Grease Monitor and Report
Arsenic Monitor and Report
Copper Monitor and Report Selenium Monitor and Report Zinc Monitor and Report
Cyanide free Monitor and Report
total Monitor and Report
Tetrachloroethylene Monitor and Report
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum Trichloroethylene Monitor and Report Vinyl Chloride Monitor and Report Fecal Coliforms Monitor and Report Total Suspended Solids Monitor and Report Chlordane Monitor and Report
trans-1, 2 Dichloroethylene Monitor and Report cis-1, 2 Dichloroethylene Monitor and Report
Chloroform Monitor and Report pH not less than 6.0 nor greater than 9.0 Outfall 202: new discharge.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608 Tetrachloroethylene Monitor and Report Trichloroethylene Monitor and Report
Vinyl Chloride Monitor and Report
Chlordane Monitor and Report trans-1, 2 Dichloroethylene Monitor and Report
cis-1, 2 Dichloroethylene Monitor and Report
Chloroform Monitor and Report
Fecal Coliforms Monitor and Report
Oil and Grease Monitor and Report
pH Monitor and Report Outfall 002: existing discharge.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCBs Not Detectable Using EPA Method 608 Chlordane Not Detectable Using EPA Method 608 pH not less than 6.0 nor greater than 9.0 Outfall 003: existing discharge.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608
Oil and Grease Monitor and Report Tetrachloroethylene Monitor and Report Trichloroethylene Monitor and Report Vinyl Chloride Monitor and Report Chlordane Monitor and Report
pH not less than 6.0 nor greater than 9.0 Outfall 104: new discharge.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608
Oil and Grease Monitor and Report
Total Suspended Solids Monitor and Report
VOCs Monitor and Report
Chlordane Monitor and Report
pH not less than 6.0 nor greater than 9.0 Outfall 204: new discharge.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608
Oil and Grease Monitor and Report Chlordane Monitor and Report Outfall 004: existing discharge.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608
Chlordane Not Detectable Using EPA Method 608
pH not less than 6.0 nor greater than 9.0 Outfall 005: existing discharge, interim effluent limits.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Not Detectable Using EPA Method 608 Chlordane Monitor and Report
Oil and Grease Monitor and Report
Fecal Coliform Monitor and Report
Arsenic Monitor and Report
Chromium, tot Monitor and Report
Sulfate Monitor and Report
Lead Monitor and Report
Nickel Monitor and Report
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum Zinc Monitor and Report
Cyanide tot Monitor and Report
free Monitor and Report
Iron tot Monitor and Report dis Monitor and Report
Manganese Monitor and Report
Aluminum Monitor and Report
Fluoride Monitor and Report Mercury Monitor and Report
pH not less than 6.0 nor greater than 9.0 Outfall 005: existing discharge, final effluent limits.
Mass (lb/day)
Concentration (mg/l)
Average Maximum Average Maximum Instantaneous Parameter Monthly Daily Monthly Daily Maximum PCB-1260 Monitor and Report
Total Suspended Solids Monitor and Report
Oil and Grease Monitor and Report
VOCs Monitor and Report Chlordane Monitor and Report
pH not less than 6.0 nor greater than 9.0 The EPA waiver is in effect.
III. WQM Industrial Waste and Sewerage Applications Under The Clean Streams Law (35 P. S. §§ 691.1--691.1001)
Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.
WQM Permit No. 4605405, Sewerage, Limerick Township Municipal Authority, 529 King Road, Royersford, PA 19468. This proposed facility is located in Limerick Township, Montgomery County.
Description of Action/Activity: Construction and operation of a 75 lot single family residential subdivision on a 53 acre parcel and a 10 foot gravity sanitary sewer extension.
Southcentral Region: Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110, (717) 705-4707.
WQM Permit No. 3605405, Sewerage, LeRoy and Mary Musser, 1901 Cider Press Road, Manheim, PA 17545. This proposed facility is located in Rapho Township, Lancaster County.
Description of Proposed Action/Activity: Construction/Operation of a small flow treatment facility to serve their single family residence at 1878 Cider Press Road, Manheim.
WQM Permit No. 3605202, CAFO, David Martin Farm, 420 Nottingham Road, Nottingham, PA 19362. This proposed facility is located in Little Britain Township, Lancaster County.
Description of Proposed Action/Activity: Existing crop farm, pullet house and heifer raising facility, proposing to construct one 4,400 head swine barn. This barn will utilize a concrete manure storage located below the animal living space.
Southwest Region: Water Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.
WQM Permit No. WQG016109, Sewerage, Robert Luthultz, 277 Valley Road, Wexford, PA 15090. This proposed facility is located in Marshall Township, Allegheny County.
Description of Proposed Action/Activity: Application for the construction and operation of a small flow treatment facility to service a single-family dwelling.
WQM Permit No. WQG016110, Sewerage, Walter Sadauskus, 815 Ponderosa Drive, Imperial, PA 15126. This proposed facility is located in North Fayette Township, Allegheny County.
Description of Proposed Action/Activity: Application for the construction and operation of a small flow treatment facility to service a single-family dwelling.
WQM Permit No. 1169401-A2, Sewerage, Johnstown Redevelopment Authority, 4th Floor Public Safety Building, 401 Washington Street, Johnstown, PA 15901. This proposed facility is located in West Taylor Township, Cambria County.
Description of Proposed Action/Activity: Application for the replacement of two nonoperational channel monsters with a mechanically cleaned bar screen.
WQM Permit No. 0205406, Sewerage, Woodville Associates, LTD., 5020 Thoms Run Road, Oakdale, PA 15071. This proposed facility is located in Collier Township, Allegheny County.
Description of Proposed Action/Activity: Application for the construction and operation of a sanitary sewer system to service a 569 lot single and multifamily home development.
WQM Permit No. 0273424-A4, Sewerage, Plum Borough Municipal Authority, 4555 New Texas Road, Pittsburgh, PA 15239-1197. This proposed facility is located in Plum Borough, Allegheny County.
Description of Proposed Action/Activity: Application for the replacement and modifications of existing facilities.
IV. NPDES Applications for Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)
Northeast Region: Water Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.
NPDES
Permit No.Applicant Name and
AddressCounty Municipality Receiving
Water/UseDEP Protocol (Y/N) PAI132241 Vandling Borough
634 Hillside St.
Vandling, PA 18421Lackawanna Vandling Borough Lackawanna River,
HQ-CWFY PAI32242 Scott Township
R. R. 1, Box 438
Olyphant, PA 18447Lackawanna Scott Township Lackawanna River,
HQ-CWF;
Hull Creek,
CWFY
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.