Annex A

TITLE 25. ENVIRONMENTAL PROTECTION

PART I. DEPARTMENT OF ENVIRONMENTAL PROTECTION

Subpart C. PROTECTION OF NATURAL RESOURCES

ARTICLE II. WATER RESOURCES

CHAPTER 109. SAFE DRINKING WATER

Subchapter A. GENERAL PROVISIONS

§ 109.1. Definitions.

 The following words and terms, when used in this chapter, have the following meanings, unless the context clearly indicates otherwise:

*  *  *  *  *

BAT—Best Available Technology—The best technology, treatment techniques or other means which the Administrator finds are available for achieving compliance with maximum contaminant levels. This chapter incorporates by reference the BAT specified in 40 CFR Parts 141 and 142 (relating to National primary drinking water regulations; and National primary drinking water regulations implementation).

Bag filter—A pressure-driven separation device that removes particulate matter larger than 1 micrometer using an engineered porous filtration media. It is typically constructed of a nonrigid, fabric filtration media housed in a pressure vessel in which the direction of flow is from the inside of the bag to outside.

Bank filtration—A water treatment process that uses a well to recover surface water that has naturally infiltrated into groundwater through a riverbed or bank. Infiltration is typically enhanced by the hydraulic gradient imposed by a nearby pumping water supply or other well.

Bin—A category based on the level of Cryptosporidium present in source water. Four potential bins exist, 1—4. The higher the bin, the higher the concentration of source water Cryptosporidium.

*  *  *  *  *

Cartridge filter—A pressure-driven separation device that removes particulate matter larger than 1 micrometer using an engineered porous filtration media. It is typically constructed as rigid or semirigid, self-supporting filter elements housed in pressure vessels in which flow is from the outside of the cartridge to the inside.

*  *  *  *  *

Combined distribution system—The interconnected distribution system consisting of the distribution systems of wholesale systems and of the public water systems that obtain finished water from another public water system.

*  *  *  *  *

Conventional filtration—The series of processes for the purpose of substantial particulate removal consisting of coagulation, flocculation, clarification, and granular media filtration. The clarification step must be a solid/liquid separation process where accumulated solids are removed during this separate component of the treatment system.

*  *  *  *  *

DBP—Disinfection byproduct.

*  *  *  *  *

Dual sample set—A set of two samples collected at the same time and same location, with one sample analyzed for TTHM and the other sample analyzed for HAA5. Dual sample sets are collected for the purposes of conducting an IDSE and determining compliance with the TTHM and HAA5 MCLs under Subchapter G (relating to system management responsibilities).

*  *  *  *  *

Finished water—Water that is introduced into the distribution system of a public water system and is intended for distribution and consumption without further treatment, except as necessary to maintain water quality in the distribution system (for example, booster disinfection or addition of corrosion control chemicals).

*  *  *  *  *

Flowing stream—A course of running water flowing in a definite channel.

*  *  *  *  *

GAC10—A granular activated carbon filter bed with an empty bed contact time of 10 minutes based on averege daily flow and a carbon reactivation frequency of every 180 days, except that the reactivation frequency for GAC10 used as a BAT shall be 120 days.

GAC20—A granular activated carbon filter bed with an empty bed contact time of 20 minutes based on average daily flow and a carbon reactivation frequency of every 240 days.

*  *  *  *  *

Groundwater—Water that is located within the saturated zone below the water table and is available to supply wells and springs.

*  *  *  *  *

IDSE—Initial Distribution System Evaluation.

*  *  *  *  *

LRAA—Locational running annual average—The average, computed quarterly, of quarterly arithmetic averages of all analytical results for samples taken at a particular monitoring location during the most recent 4 calendar quarters.

*  *  *  *  *

Lake/reservoir—A natural or man made basin or hollow on the earth's surface in which water collects or is stored that may or may not have a current or single direction of flow.

*  *  *  *  *

Log inactivation—A measure of the amount of viable microorganisms that are rendered nonviable during disinfection processes and is defined as:

 Where,

 No = Initial concentration of viable microorganisms

 ND = Concentration of viable microorganisms after disinfection

 Log = Logarithm to base 10

 Log inactivation is related to percent inactivation, defined as:

 Common log-inactivation values and corresponding percent inactivation values include:

Log Inactivation Percent Inactivation
0.5-log 68.4%
1.0-log 90.0%
1.5-log 96.8%
2.0-log 99.0%
2.5-log 99.7%
3.0-log 99.9%
4.0-log 99.99%

Log removal—A measure of the physical removal of a targeted contaminant or disease-causing microorganism (or its surrogate) during water treatment processes and is defined as:

 Where,

 No = Initial concentration of targeted contaminant or disease-causing microorganism (or its surrogate)

 NR = Concentration of targeted contaminant or disease-causing microorganism (or its surrogate) after removal

 Log = Logarithm to base 10

 Log removal is related to percent removal, defined as:

 Common log removal values and corresponding percent removal values include:

Log Removal Percent Removal
0.5-log 68.4%
1.0-log 90.0%
1.5-log 96.8%
2.0-log 99.0%
2.5-log 99.7%
3.0-log 99.9%
4.0-log 99.99%

Log treatment—A measure of the removal or inactivation, or Department-approved combination of removal and inactivation, of a targeted contaminant or disease-causing microorganism (or its surrogate) during water treatment processes and is defined as:

 Log treatment = Log removal + Log inactivation

 Or,

Where,

 No = Initial concentration of a targeted contaminant or disease-causing microorganism (or its surrogate)

 NT = Concentration of a targeted contaminant or disease-causing microorganism (or its surrogate) after treatment

 Log = Logarithm to base 10

 Log treatment is related to percent treatment, defined as:

 Common log treatment values and corresponding percent treatment values include:

Log Treatment Percent Treatment
0.5-log 68.4%
1.0-log 90.0%
1.5-log 96.8%
2.0-log 99.0%
2.5-log 99.7%
3.0-log 99.9%
4.0-log 99.99%

*  *  *  *  *

Membrane filtration—

 (i) A pressure or vacuum driven separation process in which particulate matter larger than 1 micrometer is rejected by an engineered barrier, primarily through a size-exclusion mechanism, and which has a measurable removal efficiency of a target organism that can be verified through the application of a direct integrity test.

 (ii) The term includes the common membrane technologies of microfiltration, ultrafiltration, nanofiltration and reverse osmosis.

*  *  *  *  *

Microorganism—Any of a number of unicellular, multicellular or colonial bacteria, fungi, protozoa, archaea or viruses whose individuals are too small to be seen by the human eye without magnification.

*  *  *  *  *

Plant intake—The works or structures at the head of a conduit through which water is diverted from a source (for example, a river or lake) into the treatment plant.

*  *  *  *  *

Presedimentation—A preliminary treatment process used to remove gravel, sand and other particulate material from the source water through settling before the water enters the primary clarification and filtration processes in a treatment plant.

*  *  *  *  *

RAA—Running annual average—The average, computed quarterly, of quarterly arithmetic averages of all analytical results for samples taken during the most recent 4 calendar quarters.

*  *  *  *  *

Significant deficiency—A defect in design, operation or maintenance, or a failure or malfunction of the sources, treatment, storage or distribution system that the Department determines to be causing, or has the potential for causing the introduction of contamination into the water delivered to consumers.

*  *  *  *  *

2-stage lime softening—A process in which chemical addition and hardness precipitation occur in each of two distinct unit clarification processes in series prior to filtration.

*  *  *  *  *

Wholesale system—A public water system that treats source water as necessary to produce finished water and then delivers some or all of that finished water to another public water system. Delivery may be through a direct connection or through the distribution system of one or more public water systems.

§ 109.5. Organization of chapter.

 (a) This subchapter and Subchapter H (relating to laboratory certification) apply to all public water systems.

 (b) Subchapters B—G and I apply to public water systems, except bottled water and vended water systems, retail water facilities and bulk water hauling systems, unless provisions in those Subchapters are specifically referenced in Subchapter J (relating to bottled water and vended water systems, retail water facilities and bulk water hauling systems).

 (c) Subchapter J applies exclusively to bottled water and vended water systems, retail water facilities and bulk water hauling systems.

 (d) Subchapter K (relating to lead and copper) applies to community and nontransient noncommunity water systems.

 (e) Subchapter L (relating to the long-term 2 enhanced surface water treatment rule) applies to all public water systems using surface water or GUDI sources.

 (f) Subchapter M (relating to additional requirements for groundwater sources) applies to all public water systems that use groundwater, excluding those systems that combine all of their groundwater with surface water or with groundwater under the direct influence of surface water prior to treatment under § 109.202(c)(1) (relating to State MCLs, MRDLs and treatment technique requirements).

Subchapter B. MCLs, MRDLs OR TREATMENT TECHNIQUE REQUIREMENTS

§ 109.202. State MCLs, MRDLs and treatment technique requirements.

*  *  *  *  *

 (c) Treatment technique requirements for pathogenic bacteria, viruses and protozoan cysts. A public water system shall provide adequate treatment to reliably protect users from the adverse health effects of microbiological contaminants, including pathogenic bacteria, viruses and protozoan cysts. The number and type of treatment barriers and the efficacy of treatment provided shall be commensurate with the type, degree and likelihood of contamination in the source water.

 (1) A public water supplier shall provide, as a minimum, continuous filtration and disinfection for surface water and GUDI sources. The treatment technique must provide at least 99.9% removal and inactivation of Giardia lamblia cysts, and at least 99.99% removal and inactivation of enteric viruses. Beginning January 1, 2002, public water suppliers serving 10,000 or more people shall provide at least 99% removal of Cryptosporidium oocysts. Beginning January 1, 2005, public water suppliers serving fewer than 10,000 people shall provide at least 99% removal of Cryptosporidium oocysts. The Department, depending on source water quality conditions, may require additional treatment as necessary to meet the requirements of this chapter and to protect the public health.

*  *  *  *  *

 (ii) The combined total effect of disinfection processes utilized in a filtration plant shall achieve at least a 90% inactivation of Giardia cysts and a 99.9% inactivation of viruses, as determined by CTs and measurement methods established by the EPA. The residual disinfectant concentration in the water delivered to the distribution system prior to the first customer may not be less than .2 mg/L for more than 4 hours, as demonstrated by measurement taken under § 109.301(1). Failure to maintain this level that extends beyond 4 hours constitutes a breakdown in treatment. A system that experiences a breakdown in treatment shall, under § 109.701(a)(3) (relating to reporting and recordkeeping), notify the Department within 1 hour after the water system learns of the violation or the situation, and shall provide public notice in accordance with § 109.408 (relating to Tier 1 public notice categories, timing and delivery of notice).

*  *  *  *  *

 (vi) For a source including springs, infiltration galleries, cribs or wells permitted for use by the Department prior to May 16, 1992, and determined by the Department to be a GUDI source, the public water supplier shall:

 (A) Maintain a minimum residual disinfectant concentration in the water delivered to the distribution system prior to the first customer in accordance with subsection (c)(1)(iii)(A).

 (B) Provide continuous filtration and disinfection in accordance with this paragraph within 48 months after the Department determines the source of supply is a GUDI source.

 (C) Submit to the Department for approval a feasibility study within 1 year after the Department determines the source of supply is a GUDI source. The feasibility study shall specify the means by which the supplier shall, within the deadline established in clause (B), meet the requirements of this paragraph and shall otherwise comply with paragraph (1)(iv)(A).

 (2) In addition to meeting the requirements of paragraph (1), a public water supplier using surface water or GUDI sources shall also comply with the requirements of, and on the schedules in, Subchapter L (relating to long-term 2 enhanced surface water treatment rule).

 (3) A community public water system shall provide continuous disinfection and comply with Subchapter M (relating to additional requirements for groundwater sources) for groundwater sources.

*  *  *  *  *

§ 109.204. Disinfection profiling and benchmarking.

 (a) The disinfection profiling and benchmarking requirements, established by the EPA under the National Primary Drinking Water Regulations in 40 CFR 141.172, 141.530—141.536, 141.540—141.544, 141.570(c) and (d) and 141.708—141.709 are incorporated by reference except as otherwise established by this chapter.

 (b) Public water suppliers that did not conduct TTHM and HAA5 monitoring under this section because they served fewer than 10,000 persons when the monitoring was required, but serve 10,000 or more persons before January 1, 2005, shall comply with this section. These suppliers shall also establish a disinfection benchmark and consult with the Department for approval. A supplier that decides to make a significant change to its disinfection practice, as described in this section, shall consult with the Department before making such a change.

 (c) The public water supplier shall conduct disinfection profiling in accordance with the procedures and methods in the most current edition of the Disinfection Profiling and Benchmarking Guidance Manual published by the EPA. The results of the disinfection profiling and the benchmark, including raw data and analysis, shall be retained indefinitely on the water system premises or at a convenient location near the premises. Public water suppliers serving 10,000 or more persons and required to conduct disinfection profiling shall submit the disinfection profiling data and the benchmark data to the Department by June 1, 2001, in a format acceptable to the Department. Public water suppliers serving 500 to 9,999 persons shall submit the disinfection profiling data and the benchmark to the Department by October 1, 2004. Public water suppliers serving less than 500 persons shall submit the disinfection profiling data and the benchmark to the Department by April 1, 2005, in a format acceptable to the Department.

Subchapter C. MONITORING REQUIREMENTS

§ 109.301. General monitoring requirements.

 Public water suppliers shall monitor for compliance with MCLs, MRDLs and treatment technique requirements in accordance with the requirements established by the EPA under the National Primary Drinking Water Regulations, 40 CFR Part 141 (relating to national primary drinking water regulations), except as otherwise established by this chapter unless increased monitoring is required by the Department under § 109.302 (relating to special monitoring requirements). Alternative monitoring requirements may be established by the Department and may be implemented in lieu of monitoring requirements for a particular National Primary Drinking Water Regulation if the alternative monitoring requirements are in conformance with the Federal act and regulations. The monitoring requirements shall be applied as follows:

*  *  *  *  *

 (8) Monitoring requirements for public water systems that obtain finished water from another public water system.

*  *  *  *  *

 (vi) Community water systems and nontransient noncommunity water systems that obtain finished water from another permitted public water system shall comply with the monitoring requirements for disinfection byproducts and disinfectant residuals in paragraphs (12)(i)—(v) and (13).

 (vii) A community water system which is a consecutive water system shall comply with the monitoring requirements for lead and copper as specified in § 109.1101(c) (relating to lead and copper).

 (viii) A public water supplier that obtains finished water from another permitted public water system using groundwater shall comply with Subchapter M (relating to additional requirements for groundwater sources).

*  *  *  *  *

 (12) Monitoring requirements for disinfection byproducts and disinfection byproduct precursors. Community water systems and nontransient noncommunity water systems that use a chemical disinfectant or oxidant shall monitor for disinfection byproducts and disinfection byproduct precursors in accordance with this paragraph. Community water systems and nontransient noncommunity water systems that obtain finished water from another public water system that uses a chemical disinfectant or oxidant to treat the finished water shall monitor for TTHM and HAA5 in accordance with this paragraph. Systems that use either surface water or GUDI sources and that serve at least 10,000 persons shall begin monitoring by January 1, 2002. Systems that use either surface water or GUDI sources and that serve fewer than 10,000 persons, or systems that use groundwater sources, shall begin monitoring by January 1, 2004. Systems monitoring for disinfection byproducts and disinfection byproduct precursors shall take all samples during normal operating conditions. Systems monitoring for disinfection byproducts and disinfection byproduct precursors shall use only data collected under this chapter to qualify for reduced monitoring. Compliance with the MCLs and monitoring requirements for TTHM, HAA5, chlorite (where applicable) and bromate (where applicable) shall be determined in accordance with 40 CFR 141.132 and 141.133 (relating to monitoring requirements; and compliance requirements) which are incorporated herein by reference.

 (i) TTHM and HAA5 Stage 1 DBP Rule.

*  *  *  *  *

 (B) Reduced monitoring. Systems shall monitor for TTHM and HAA5 for at least 1 year prior to qualifying for reduced monitoring. Systems serving at least 500 persons and that use either surface water or GUDI sources shall monitor source water TOC monthly for at least 1 year prior to qualifying for reduced monitoring. The Department retains the right to require a system that meets the requirements of this clause to resume routine monitoring.

 (I) For systems serving at least 500 persons that use either surface water or GUDI sources and that have a source water TOC running annual average that is no greater than 4.0 mg/L, a TTHM running annual average that is no greater than 0.040 mg/L and an HAA5 running annual average that is no greater than 0.030 mg/L, the required monitoring is reduced according to items (-a-) and (-b-). Systems serving at least 10,000 persons shall resume routine monitoring as prescribed in clause (A) if the TTHM running annual average exceeds 0.060 mg/L or the HAA5 running annual average exceeds 0.045 mg/L. Systems serving from 500 to 9,999 persons shall resume routine monitoring as prescribed in clause (A) if the annual TTHM average exceeds 0.060 mg/L or the annual HAA5 average exceeds 0.045 mg/L. Systems serving at least 500 persons that must resume routine monitoring shall resume routine monitoring in the quarter immediately following the quarter in which the system exceeded the specified TTHM or HAA5 criteria.

*  *  *  *  *

 (-c-) Beginning April 1, 2008, systems not monitoring under the provisions of subparagraph (v) shall take monthly TOC samples every 30 days at a location prior to any treatment, to qualify for reduced monitoring for TTHM and HAA5 under this subparagraph. In addition to meeting other criteria for reduced monitoring in this section, the source water TOC running annual average must be less than or equal to 4.0 mg/L (based on the most recent 4 quarters of monitoring) on a continuing basis at each treatment plant to reduce or remain on reduced monitoring for TTHM and HAA5. Once qualified for reduced monitoring for TTHM and HAA5 under this section, a system may reduce source water TOC monitoring to quarterly TOC samples taken every 90 days at a location prior to any treatment.

 (II) For systems that use only groundwater sources not included under subclause (I), the required monitoring is reduced according to the following:

*  *  *  *  *

 (-b-) For systems serving fewer than 10,000 persons that have an annual TTHM average that is no greater than 0.040 mg/L and an annual HAA5 average that is no greater than 0.030 mg/L for 2 consecutive years or an annual TTHM average that is no greater than 0.020 mg/L and an annual HAA5 average that is no greater than 0.015 mg/L for 1 year, the required monitoring is reduced to one sample per 3-year cycle per treatment plant. The sample shall be taken at a location that represents a maximum residence time during the month of warmest water temperature. The 3-year cycle shall begin on January 1 following the quarter in which the system qualifies for reduced monitoring. If the TTHM annual average exceeds 0.060 mg/L, or the HAA5 annual average exceeds 0.045 mg/L the system shall resume routine monitoring as prescribed in clause (A), except that systems that exceed either a TTHM or HAA5 MCL shall increase monitoring to at least one sample per quarter per treatment plant beginning in the quarter immediately following the quarter in which the system exceeds the TTHM or HAA5 MCL.

 (ii) TTHM and HAA5 Stage 2 DBP Rule.

 (A) Applicability and schedule.

 (I) Community water systems and nontransient noncommunity water systems using a primary or residual disinfectant other than ultraviolet light or delivers water that has been treated with a primary or residual disinfectant other than ultraviolet light shall monitor for compliance with the MCLs based on the LRAA for TTHM and HAA5. Any system that is part of a combined distribution system shall comply at the same time as the system with the earliest compliance date in the combined distribution system. Systems shall comply with this subparagraph as follows:

 (-a-) Systems serving 100,000 or more people begin April 1, 2012.

 (-b-) Systems serving from 50,000 to 99,999 people begin October 1, 2012.

 (-c-) Systems serving from 10,000 to 49,999 people begin October 1, 2013.

 (-d-) Systems serving less than 10,000 people:

 (-1-) Begin October 1, 2013, if no Cryptosporidium monitoring is required under §§ 109.1201—109.1204.

 (-2-) Begin October 1, 2014, if Cryptosporidium monitoring is required under §§ 109.1201—109.1204.

 (II) For the purpose of the schedule under this subparagraph, the Department may determine that the combined distribution system does not include certain consecutive water systems based on factors such as receiving water from a wholesale system only on an emergency basis or receiving only a small percentage and small volume of water from a wholesale system. The Department may also determine that the combined distribution system does not include certain wholesale systems based on factors such as delivering water to a consecutive water system only on an emergency basis or delivering only a small percentage and small volume of water to a consecutive water system.

 (III) All systems monitoring under this paragraph shall comply with subparagraph (i) until the dates specified in this subparagraph.

 (B) Routine monitoring.

 (I) A system that submitted an IDSE report shall begin monitoring at the locations and months recommended in the IDSE report unless the Department notifies the system that other locations or additional locations are required. A system that submitted a 40/30 certification, or qualified for a very small system waiver or a nontransient noncommunity water system serving less than 10,000, shall monitor at the locations and dates identified in its Stage 2 DBP rule monitoring plan following the schedule in § 109.701(g)(2)(ii) (relating to reporting and recordkeeping).

 (II) A system required to conduct quarterly monitoring shall begin monitoring in the first full calendar quarter that includes the compliance date specified in clause (A). A system required to conduct monitoring at frequencies less than quarterly shall begin monitoring in the calendar month recommended in the IDSE report in accordance with 40 CFR 141.601 and 141.602 (relating to standard monitoring; and system specific studies) as incorporated by reference or the calendar month identified in the Stage 2 DBP rule monitoring plan no later than 12 months after the applicable compliance date under clause (A).

 (III) Monitoring shall be conducted at no fewer than the number of locations identified in the table under subclauses (IV) and (V). All systems shall monitor during the month of highest DBP concentrations. Systems on quarterly monitoring shall sample every 90 days at each monitoring location. Sampling at each monitoring location shall be conducted as follows:

 (-a-) Systems using surface water or GUDI sources serving a population greater than 3,300 and systems using groundwater sourcs serving a population of 500 or greater shall take dual sample sets at each monitoring location.

 (-b-) Systems using surface water or GUDI sources serving a population of 3,300 or less and systems using groundwater sources serving a population less than 500 shall take individual TTHM and HAA5 samples at the locations with the highest TTHM and HAA5 concentrations, respectively.

 (-c-) Systems serving a population less than 500 may take a dual sample set at one location per monitoring period if the highest TTHM and HAA5 concentrations occur at the same location and during the same month.

 (IV) Community water systems and nontransient noncommunity water systems using surface water or GUDI sources shall monitor as follows:

Population size Monitoring frequencies Distribution system monitoring location total per monitoring period
< 500Annually2
500—3,300Quarterly2
3,301—9,999Quarterly2
10,000—49,999Quarterly4
50,000—249,999Quarterly8
250,000—999,999Quarterly12
1,000,000—4,999,999Quarterly16
>= 5,000,000Quarterly20

 (V) Community water systems and nontransient noncommunity water systems using groundwater sources shall monitor as follows:

Population size Monitoring frequencies Distribution system monitoring location total per monitoring period
< 500Annually2
500—9,999Annually2
10,000—99,999Quarterly4
100,000—499,999Quarterly6
>= 500,000Quarterly8

 (VI) An undisinfected system that begins using a disinfectant other than UV light after the dates under 40 CFR 141.600 (relating to general requirements) as incorporated by reference for complying with the IDSE requirements, shall consult with the Department to identify compliance monitoring locations. The system shall develop a monitoring plan under § 109.701(g)(2)(ii) that includes those monitoring locations.

 (VII) Systems shall use analytical techniques adopted by the EPA under the Federal act for TTHM and HAA5 analyses. Laboratories that have received accreditation by the Department shall conduct analyses.

 (C) Reduced monitoring.

 (I) Systems may reduce monitoring to the level specified in the table under subclauses (II) and (III) if, after at least 4 consecutive quarters, the LRAA is equal to or less than 0.040 mg/L for TTHM and equal to or less than 0.030 mg/L for HAA5 at all monitoring locations. Only data collected under subparagraph (i) and this subparagraph may be used to qualify for reduced monitoring. Systems with surface water or GUDI sources shall also take monthly TOC samples every 30 days at a location prior to any treatment, to qualify for reduced monitoring for TTHM and HAA5 under this clause. In addition to meeting other criteria for reduced monitoring in this clause, the source water TOC running annual average (based on the most recent 4 quarters of monitoring) must be equal to or less than 4.0 mg/L on continuing basis at each treatment plant to reduce monitoring for TTHM and HAA5. Once qualified for reduced monitoring for TTHM and HAA5 under this clause, a system may reduce source water TOC monitoring to quarterly TOC samples taken every 90 days at a location prior to any treatment.

 (II) Community water systems and nontransient noncommunity water systems using surface water or GUDI sources may reduce monitoring as follows:

Population size Monitoring frequencies
Distribution system monitoring location total
per monitoring period
< 500Monitoring may not be reduced
500—3,300Annually1 TTHM and 1 HAA5 sample: 1 at the location and during the quarter with the highest TTHM single measurement, 1 at the location and during the quarter with the highest HAA5 single measurement; 1 dual sample set per year if the highest TTHM and HAA5 measurements occurred at the same location and quarter.
3,301—9,999Annually2 dual sample sets: 1 at the location and during the quarter with the highest TTHM single measurement, 1 at the location and during the quarter with the highest HAA5 single measurement.
10,000—49,999Quarterly2 dual sample sets at the locations with the highest TTHM and the highest HAA5 LRAAs.
50,000—249,999Quarterly4 dual sample sets at the locations with two highest TTHM and two highest HAA5 LRAAs.
250,000—999,999Quarterly6 dual sample sets at the locations with the three highest TTHM and the three highest HAA5 LRAAs.
1,000,000—4,999,999Quarterly 8 dual sample sets at the location with the 4 highest TTHM and 4 highest HAA5 LRAAs.
>= 5,000,000Quarterly10 dual sample sets at the locations with the five highest TTHM and five highest HAA5 LRAAs.

 (III) Community water systems and nontransient noncommunity water systems using groundwater sources may reduce monitoring as follows:

Population size Monitoring frequencies
Distribution system monitoring location total
per monitoring period
< 500Every third year1 TTHM and 1 HAA5 sample: 1 at the location and during the quarter with the highest TTHM single measurement; 1 at the location and during quarter with highest HAA5 single measurement; 1 dual sample set per year if the highest TTHM and HAA5 measurements occurred at the same location and quarter.
500—9,999Annually1 TTHM and 1 HAA5 sample: 1 at the location and during the quarter with highest TTHM single measurement; 1 at the location during the quarter with the highest HAA5 single measurement; 1 dual sample set per year if the highest TTHM and HAA5 measurements occurred at the same location and quarter.
10,000—99,999Annually2 dual sample sets: 1 at the location and during the quarter with the highest TTHM single measurement; 1 at the location and during the quarter with the highest HAA5 single measurement.
100,000—499,999Quarterly2 dual sample sets at the locations with the highest TTHM and highest HAA5 LRAAs.
>= 500,000Quarterly4 dual sample sets at the locations with the two highest TTHM and two highest HAA5 LRAAs.

 (IV) Systems on reduced quarterly monitoring may remain on reduced monitoring as long as the TTHM LRAA is equal to or less than 0.040 mg/L and the HAA5 LRAA is equal to or less than 0.030 mg/L at each monitoring location. Systems on reduced annual or less frequent monitoring may remain on reduced monitoring as long as each TTHM sample result is equal to or less than 0.060 mg/L and each HAA5 sample result is equal to or less than 0.045 mg/L. In addition, the source water TOC running annual average (based on the most recent 4 quarters of monitoring) from samples collected every 90 days at a location prior to any treatment must be equal to or less than 4.0 mg/L at each treatment plant treating surface water or GUDI sources.

 (V) If the LRAA based on quarterly monitoring at any monitoring location exceeds either 0.040 mg/L for TTHM or 0.030 mg/L for HAA5 or if the annual (or less frequent) sample at any location exceeds either 0.060 mg/L for TTHM or 0.045 mg/L for HAA5, or if the source water annual average TOC level, before any treatment, is greater than 4.0 mg/L at any treatment plant treating surface water or GUDI sources, the system shall resume routine monitoring under clause (B) or begin increased monitoring if clause (D)(I) applies.

 (VI) The Department retains the right to require a system that meets the requirements of this clause to resume routine monitoring.

 (VII) A system may remain on reduced monitoring after the dates identified in clause (A) for compliance with this subparagraph only if the criteria specified in items (-a-)—(-c-) are met. If any condition is not met, the system shall resume routine monitoring as specified in clause (B) by the dates specified in clause (A).

 (-a-) The system qualified for a 40/30 certification under 40 CFR 141.603 (relating to 40/30 certification) as incorporated by reference or has received a very small system waiver under 40 CFR 141.604 (relating to very small system waivers) as incorporated by reference.

 (-b-) The system meets the reduced monitoring criteria in this clause.

 (-c-) The system has not changed or added monitoring locations from those used for compliance monitoring in subparagraph (i).

 (D) Increased monitoring.

 (I) Systems that are required to monitor at a particular location annually or less frequently than annually under clause (B) or (C) shall increase monitoring to dual sample sets once per quarter (taken every 90 days) at all locations if any single TTHM sample result is greater than 0.080 mg/L or any single HAA5 sample result is greater than 0.060 mg/L at any location.

 (II) A system may return to routine monitoring once it has conducted increased monitoring for at least 4 consecutive quarters and the LRAA for every monitoring location is equal to or less than 0.060 mg/L for TTHM and is equal to or less than 0.045 mg/L for HAA5.

 (III) Systems on increased monitoring under subparagraph (i) shall remain on increased monitoring until they qualify for a return to routine monitoring under subclause (II). Systems shall conduct increased monitoring under subclause (I) at the monitoring locations in the monitoring plan developed under § 109.701(g)(2)(ii) beginning at the date identified in clause (A) for compliance with this subparagraph and remain on increased monitoring until they qualify for a return to routine monitoring under subclause (II).

 (E) General monitoring and compliance requirements.

 (I) A system required to monitor quarterly shall calculate LRAAs for TTHM and HAA5 using monitoring results collected under this subparagraph and determine that each LRAA does not exceed the MCL. A system that fails to complete four consecutive quarters of monitoring, shall calculate compliance with the MCL based on the average of the available data from the most recent 4 quarters. A system that takes more than one sample per quarter at a monitoring location shall average all samples taken in the quarter at that location to determine a quarterly average to be used in the LRAA calculation.

 (II) A system required to monitor yearly or less frequently shall determine that each sample result is less than the MCL. If any single sample result exceeds the MCL, the system shall comply with the requirements of clause (D). If no sample result exceeds the MCL, the sample result for each monitoring location is considered the LRAA for that monitoring location.

 (III) A system required to conduct quarterly monitoring, shall make compliance calculations at the end of the 4th calendar quarter that follows the compliance date (or earlier if the LRAA calculated based on fewer than 4 quarters of data would cause the MCL to be exceeded regardless of the monitoring results of subsequent quarters) and at the end of each subsequent calendar quarter. A system required to conduct monitoring at a frequency that is less than quarterly shall make compliance calculations beginning with the first compliance sample taken after the compliance date.

 (IV) A system is in violation of the MCL when the LRAA at any location exceeds the MCL for TTHM or HAA5, calculated as specified in subclause (I), or the LRAA calculated based on fewer than 4 quarters of data if the MCL would be exceeded regardless of the monitoring results of subsequent quarters. A system is in violation of the monitoring requirements for each quarter that a monitoring result would be used in calculating an LRAA if it fails to monitor.

 (iii) Chlorite. Community water systems and non- transient noncummunity water systems that use chlorine dioxide for disinfection or oxidation shall monitor for chlorite.

*  *  *  *  *

 (iv) Bromate. Community water systems and non- transient noncommunity water systems that use ozone for disinfection or oxidation shall monitor for bromate.

*  *  *  *  *

 (B) Reduced monitoring.

 (I) Until March 31, 2009, systems that have an average source water bromide concentration that is less than 0.05 mg/L based upon representative monthly bromide measurements for 1 year, the required monitoring is reduced from monthly to quarterly. Systems on reduced monitoring shall continue to take monthly samples for source water bromide. If the running annual average source water bromide concentration, computed quarterly, equals or exceeds 0.05 mg/L based upon representative monthly measurements, the system shall revert to routine monitoring as prescribed by clause (A).

 (II) Beginning April 1, 2009, a system required to analyze for bromate may reduce monitoring from monthly to quarterly, if the system's running annual average bromate concentration computed quarterly is less than or equal to 0.0025 mg/L based on monthly measurements as prescribed in clause (A) for the most recent 4 quarters. Systems qualifying for reduced bromate monitoring under subclause (I) may remain on reduced monitoring as long as the running annual average of quarterly bromate samples is less than or equal to 0.0025 mg/L. If the running annual average bromate concentration is greater than 0.0025 mg/L, the system shall resume routine monitoring as prescribed under clause (A).

 (v) DBP precursors. Community water systems and nontransient noncommunity water systems that use either surface water or GUDI sources and that use conventional filtration shall monitor for disinfection byproduct precursors.

*  *  *  *  *

§ 109.304. Analytical requirements.

 (a) Sampling and analysis shall be performed in accordance with analytical techniques adopted by the EPA under the Federal act or methods approved by the Department.

 (b) An alternate analytical technique may be employed with the written approval of the Department and the concurrence of the Administrator. An alternate technique will be accepted only if it is substantially equivalent to the prescribed test in both precision and accuracy as it relates to the determination of compliance with MCLs or MRDLs or treatment technique requirements. The use of the alternate analytical technique may not decrease the frequency of monitoring required by this subchapter.

 (c) For the purpose of determining compliance with the monitoring and analytical requirements established under this subchapter and Subchapters K, L and M (relating to lead and copper; long-term 2 enhanced surface water treatment rule; and additional requirements for groundwater sources), the Department will consider only samples analyzed by a laboratory accredited by the Department, except that measurements for turbidity, fluoridation operation, residual disinfectant concentration, temperature, pH, alkalinity, orthophosphates, silica, calcium, conductivity, daily chlorite, and magnesium hardness may be performed by a person meeting one of the following requirements:

 (1) A person meeting the requirements of § 109.704 (relating to operator certification).

 (2) A person using a standard operating procedure as provided under authority of the Water and Wastewater Systems Operators' Certification Act (63 P.S. §§ 1001—1015.1).

 (3) An environmental laboratory meeting the requirements of Chapter 252 (relating to environmental laboratory accreditation).

 (d) A system shall have Cryptosporidium samples analyzed by a laboratory that is approved under the EPA's Laboratory Quality Assurance Evaluation Program for Analysis of Cryptosporidium in Water or a laboratory that has been accredited for Cryptosporidium analysis by an equivalent Department laboratory accreditation program.

Subchapter D. PUBLIC NOTIFICATION

§ 109.407. General public notification requirements.

 (a) Violation categories and other situations requiring a public notice. A public water supplier shall give public notice for the following circumstances:

 (1) Failure to comply with an applicable State primary MCL or MRDL in Subchapter B (relating to MCLs, MRDLs or treatment technique requirements).

 (2) Failure to comply with a prescribed treatment technique requirement in Subchapter B, G, K, L or M.

 (3) Failure to perform water quality monitoring, as required by Subchapter C (relating to monitoring requirements) or Subchapter K.

 (4) Operation under a variance or an exemption under Subchapter I (relating to variances and exemptions issued by the Department).

 (5) Failure to comply with the requirements of any schedule that has been set under a variance or exemption.

 (6) Occurrence of a waterborne disease outbreak, as defined in § 109.1 (relating to definitions), or other emergency situation as defined in § 109.701(a)(3)(iii) (relating to reporting and recordkeeping) that adversely affects the quality or quantity of finished water and has a significant potential to have serious adverse effects on human health as a result of short-term exposure.

 (7) Availability of unregulated contaminant monitoring data.

 (8) Exceedance of the nitrate MCL by noncommunity water systems, when permitted by the Department in writing to exceed the MCL in accordance with 40 CFR 141.11(d) (relating to MCLs for inorganic contaminants).

 (9) Other violations or situations determined by the Department to require a public notice under this subchapter.

*  *  *  *  *

§ 109.408. Tier 1 public notice—categories, timing and delivery of notice.

 (a) General violation categories and other situations requiring a Tier 1 public notice. A public water supplier shall provide Tier 1 public notice for the following circumstances:

 (1) Violation of the MCL for total coliforms when fecal coliforms or E. coli are present in the water distribution system, as specified in § 109.202(a)(2) (relating to MCLs, MRDLs or treatment technique requirements), or when the water supplier fails to test for fecal coliforms or E. coli when any check sample tests positive for coliforms, as specified in § 109.301(3) (relating to general monitoring requirements).

 (2) Violation of the MCL for nitrate, nitrite or total nitrate and nitrite, as defined in § 109.202(a)(2), or when the water supplier fails to take a confirmation sample within 24 hours of the system's receipt of the first sample showing an exceedance of the nitrate or nitrite MCL, as specified in § 109.301(7)(ii)(C)(V).

 (3) Exceedance of the nitrate MCL by noncommunity water systems, when permitted by the Department in writing to exceed the MCL in accordance with 40 CFR 141.11(d) (relating to maximum contaminant levels for inorganic chemicals).

 (4) Violation of the MRDL for chlorine dioxide, as defined in § 109.202(f)(2), when one or more samples taken in the distribution system the day following an exceedance of the MRDL at the entrance of the distribution system exceed the MRDL, or when the water supplier does not take the required samples in the distribution system, as specified in § 109.301.

 (5) Violation of the turbidity MCL of 5 NTU based on an average for 2 consecutive days by a public water system using an unfiltered surface water source, as specified in § 109.202(a)(2).

 (6) Violation of a treatment technique requirement for pathogenic bacteria, viruses and protozoan cysts as defined in § 109.202(c), resulting from a single exceedance of the maximum allowable turbidity limit.

 (7) Violation of a treatment technique requirement for Cryptosporidium as defined in § 109.1203 (relating to bin classification and treatment technique requirements), resulting from a failure to provide the level of treatment appropriate for the systems bin classification.

 (8) Detection of E. coli in source water samples as specified in §§ 109.1303 and 109.1304 (relating to triggered monitoring requirements for groundwater sources; and assessment source water monitoring).

 (9) A breakdown in treatment for groundwater sources as specified in § 109.1307(a)(1)(ii) (relating to system management responsibilities).

 (10) Occurrence of a waterborne disease outbreak, as defined in § 109.1 (relating to definitions), or other emergency situation as defined in § 109.701(a)(3)(iii) (relating to reporting and recordkeeping) that adversely affects the quality or quantity of the finished water and has a significant potential to have serious adverse effects on human health as a result of short-term exposure.

 (11) Other violations or situations with significant potential to have serious adverse effects on human health as a result of short-term exposure, as determined by the Department on a case-by-case basis.

*  *  *  *  *

§ 109.409. Tier 2 public notice—categories, timing and delivery of notice.

 (a) General violation categories and other situations requiring a Tier 2 public notice. A public water supplier shall provide Tier 2 public notice for the following circumstances:

 (1) All violations of the primary MCL, MRDL treatment technique requirements and failure to take corrective action in Subchapters B, G, K, L or M, except when a Tier 1 notice is required under § 109.408 (relating to Tier 1 public notice—categories, timing and delivery of notice) or when the Department determines that a Tier 1 notice is required. The tier assignment for fluoride is not incorporated by reference. Under § 109.202(d) (relating to MCLs, MRDLs or treatment technique requirements), a public water system shall comply with the primary MCL for fluoride of 2 mg/L. As such, a public water supplier shall provide Tier 2 public notice for violation of the primary MCL for fluoride.

 (2) Violations of the monitoring requirements in Subchapter C, K or M (relating to monitoring requirements; lead and copper; and additional requirements for groundwater sources), when the Department determines that a Tier 2 rather than a Tier 3 public notice is required, taking into account potential health impacts and persistence of the violation.

*  *  *  *  *

§ 109.410. Tier 3 public notice—categories, timing and delivery of notice.

 (a) General violation categories and other situations requiring a Tier 3 public notice. A public water supplier shall provide Tier 3 public notice for the following circumstances:

 (1) Monitoring violations under Subchapter C, K, L or M, except when a Tier 1 notice is required under § 109.408 (relating to Tier 1 public notice—categories, timing and delivery of notice) or when the Department determines that a Tier 2 notice is required.

 (2) Reporting and record maintenance violations under § 109.701(h) (relating to reporting and recordkeeping).

 (3) Operation under a variance or an exemption granted under Subchapter I (relating to variances and exemptions issued by the Department).

 (4) Availability of unregulated contaminant monitoring results, as required under 40 CFR 141.40 (relating to monitoring requirements for unregulated contaminants).

*  *  *  *  *

§ 109.417. Special notice for significant deficiencies by noncommunity water systems.

 (a) In addition to the applicable public notification requirements of this subchapter, a noncommunity water system that receives notice from the Department under § 109.1302(c)(2) (relating to groundwater systems with significant deficiencies or source water E. coli contamination) of a significant deficiency shall inform the public served by the water system in a manner approved by the Department of any significant deficiency that has not been corrected within 12 months of being notified by the Department, or earlier if directed by the Department. The system shall continue to inform the public annually until the significant deficiency is corrected. The information must include:

 (1) The nature of the significant deficiency and the date the significant deficiency was identified by the Department.

 (2) The Department-approved plan and schedule for correction of the significant deficiency, including interim measures, progress to date, and any interim measures completed.

 (3) For systems with a large proportion of non-English speaking consumers specified in § 109.411(c)(2) (relating to content of a public notice), information in the appropriate languages regarding the importance of the notice or a telephone number or address where consumers may contact the system to obtain a translated copy of the notice or assistance in the appropriate language.

 (b) If directed by the Department, a noncommunity water system with significant deficiencies that have been corrected in accordance with § 109.1302(c)(1) shall inform its customers of the significant deficiencies, how the deficiencies were corrected, and the dates of correction.

§ 109.418. Special notice for failure to conduct source water Cryptosporidium monitoring or failure to determine bin classification.

 (a) Special notice for repeated failure to conduct monitoring of the source water for Cryptosporidium and for failure to determine bin classification or Cryptosporidium level. The owner or operator of a community or noncommunity water system that is required to monitor source water under § 109.1202 (relating to monitoring requirements) shall notify persons served by the water system that monitoring has not been completed as specified no later than 30 days after the system has failed to collect any 3 months of monitoring as specified in § 109.1202(c). The notice shall be repeated as specified in § 109.409(b)(3) (relating to Tier 2 public notice—form, manner and frequency of notice).

 (b) Delivery of the special notice for failure to determine bin classification or Cryptosporidium level. The owner or operator of a community or noncommunity water system that is required to determine a bin classification under § 109.1203 (relating to bin classification and treatment technique requirements), or to determine Crypto- sporidium level under § 109.1203(i) and (j), shall notify persons served by the water system that the determination has not been made as required no later than 30 days after the system has failed to report the determination as specified in § 109.1206(h) (relating to reporting and recordkeeping requirements) or § 109.1203(i) and (j), initial round and second round, respectively. The notice shall be repeated as specified in § 109.409(b)(3). The notice is not required if the system is complying with a Department-approved schedule to address the violation.

 (c) Form and manner of the special notice.

 (1) The form and manner of the public notice must follow the requirements for a Tier 2 public notice prescribed in § 109.409(c). The public notice shall be presented as required in § 109.411(c) (relating to content of a public notice).

 (2) The notice must contain the following language, including the language necessary to fill in the blanks.

 (i) The special notice for repeated failure to conduct monitoring must contain the following language:

''We are required to monitor the source of your drinking water for Cryptosporidium. Results of the monitoring are to be used to determine whether water treatment at the (treatment plant name) is sufficient to adequately remove Cryptosporidium from your drinking water. We are required to complete this monitoring and make this determination by (required bin determination date). We 'did not monitor or test' or 'did not complete all monitoring or testing' on schedule and, therefore, we may not be able to determine by the required date what treatment modifications, if any, must be made to ensure adequate Cryptosporidium removal. Missing this deadline may, in turn, jeopardize our ability to have the required treatment modifications, if any, completed by the deadline required, (date). For more information, please call (name of water system contact) of (name of water system) at (phone number).''

 (ii) The special notice for failure to determine bin classification or Cryptosporidium level must contain the following language:

''We are required to monitor the source of your drinking water for Cryptosporidium to determine by (date) whether water treatment at the (treatment plant name) is sufficient to adequately remove Cryptosporidium from your drinking water. We have not made this determination by the required date. Our failure to do this may jeopardize our ability to have the required treatment modifications, if any, completed by the required deadline of (date). For more information, please call (name of water system contact) of (name of water system) at (phone number).''

 (3) Each special notice must also include a description of what the system is doing to correct the violation and when the system expects to return to compliance or resolve the situation.

Subchapter E. PERMIT REQUIREMENTS

§ 109.503. Public water system construction permits.

 (a) Permit application requirements. An application for a public water system construction permit shall be submitted in writing on forms provided by the Department and shall be accompanied by plans, specifications, engineer's report, water quality analyses and other data, information or documentation reasonably necessary to enable the Department to determine compliance with the act and this chapter. The Department will make available to the applicant the Public Water Supply Manual, available from the Bureau of Water Standards and Facility Regulation, Post Office Box 8774, Harrisburg, Pennsylvania 17105 which contains acceptable design standards and technical guidance. Water quality analyses shall be conducted by a laboratory accredited under this chapter.

 (1) General requirements. An application must include:

*  *  *  *  *

 (iii) Information describing new sources. The Department may accept approval of an out-of-State source by the agency having jurisdiction over drinking water in that state if the supplier submits adequate proof of the approval and the agency's standards are at least as stringent as this chapter. Information describing sources must include:

*  *  *  *  *

 (B) An evaluation of the quality of the raw water from each new source. This clause does not apply when the new source is finished water obtained from an existing permitted community water system unless the Department provides written notice that an evaluation is required. The evaluation must include analysis of the following:

 (I) VOCs for which MCLs have been established by the EPA under the National Primary Drinking Water Regulations in 40 CFR 141.61(a) (relating to maximum contaminant levels for organic contaminants). Vinyl chloride monitoring is required only if one or more of the two-carbon organic compounds specified under § 109.301(5)(i) (relating to general monitoring requirements) are detected. Samples for VOCs shall be collected in accordance with § 109.303(d) (relating to sampling requirements).

 (II) Except for asbestos, IOCs for which MCLs have been established by the EPA under the National Primary Drinking Water Regulations in 40 CFR 141.62 (relating to maximum contaminant levels for inorganic contaminants). The new source shall be monitored for asbestos if the Department has reason to believe the source water is vulnerable to asbestos contamination.

 (III) Lead.

 (IV) Copper.

 (V) Total coliform concentration and, if total coliform-positive, analyze for the presence of E. coli.

 (VI) SOCs.

 (-a-) Except for SOCs that have been granted a Statewide waiver, SOCs for which MCLs have been established by the EPA under the National Primary Drinking Water Regulations in 40 CFR 141.61(c).

 (-b-) Dioxin where there is a source of dioxin contamination within 1,000 feet of a groundwater source or within 1 mile upstream of a surface water source.

 (-c-) Polychlorinated biphenyls (PCBs) where there is a source of PCB contamination within 1,000 feet of a groundwater source or within 1 mile upstream of a surface water source.

 (VII) Gross Alpha (alpha), radium-226, radium-228, uranium and Gross Beta (beta).

 (VIII) Aluminum, chloride, color, foaming agents, iron, manganese, pH, silver, sulfate, total dissolved solids and zinc for which MCLs have been established by the EPA under the National Secondary Drinking Water Regulations in 40 CFR 143.3 (relating to secondary MCLs).

 (IX) Alkalinity.

 (X) Hardness.

 (XI) Temperature.

 (XII) For surface water or GUDI sources, E. coli or Cryptosporidium, or both, as specified in § 109.1202 (relating to monitoring requirements).

 (XIII) Other contaminants that the Department determines necessary to evaluate the potability of the source.

*  *  *  *  *

§ 109.505. Requirements for noncommunity water systems.

 (a) A noncommunity water system shall obtain a construction permit under § 109.503 (relating to public water system construction permits) and an operation permit under § 109.504 (relating to public water system operation permits), unless the noncommunity water system satisfies paragraph (1) or (2). The Department retains the right to require a noncommunity water system that meets the requirements of paragraph (1) or (2) to obtain a construction and an operation permit, if, in the judgment of the Department, the noncommunity water system cannot be adequately regulated through standardized specifications and conditions. A noncommunity water system which is released from the obligation to obtain a construction and an operation permit shall comply with the other requirements of this chapter, including design, construction and operation requirements described in Subchapters F and G (relating to design and construction standards; and system management responsibilities).

*  *  *  *  *

 (2) A noncommunity water system not covered under paragraph (1) is not required to obtain a construction and an operation permit if it satisfies the following specifications and conditions:

 (i) The sources of supply for the system are groundwater sources requiring treatment no greater than disinfection to provide water of a quality that meets the primary MCLs established under Subchapter B (relating to MCLs, MRDLs or treatment technique requirements).

 (ii) The water supplier files a brief description of the system, including raw source quality data, on forms acceptable to the Department. Amendments to the system description shall be filed when a substantial modification is made to the system. Descriptions of new systems or modifications shall be submitted and approved by the Department prior to construction.

 (3) A noncommunity water system which satisfies the requirements of paragraphs (1) and (2) shall provide the Department with the following information describing new sources, including an evaluation of the quality of the raw water from each new source. Water quality analyses shall be conducted by a laboratory certified under this chapter. This paragraph does not apply when the new source is finished water obtained from an existing permitted community water system or an existing permitted or approved noncommunity water system unless the Department provides written notice that one or more of the provisions of this paragraph apply.

 (i) For transient noncommunity water systems, the evaluation must include analysis of the following:

*  *  *  *  *

 (B) Total coliform concentration and, if total coliform-positive, analyze for the presence of E. coli.

*  *  *  *  *

 (b) A noncommunity water system providing 4-log treatment of a groundwater source under § 109.1302(b) (relating to treatment technique requirements) that has not obtained a construction permit under § 109.503 (relating to public water system construction permits) and an operations permit under § 109.504 (relating to public water system operation permits) shall obtain a noncommunity water system 4-log treatment of groundwater permit under § 109.1306 (relating to information describing 4-log treatment and compliance monitoring) and comply with subsection (a)(2)(ii).

§ 109.507. Permits for Innovative Technology.

 The Department may consider proposals for innovative water treatment processes, methods or equipment and may issue an innovative technology construction or operation permit if the applicant demonstrates to the Department's satisfaction that the proposal will provide drinking water that complies with Subchapters B, L and M (relating to MCLs, MRDLs or treatment technique requirements; long-term 2 enhanced surface water treatment rule; and additional requirements for groundwater sources). Applications for innovative technology construction permits must satisfy the requirements of § 109.503 (relating to public water system construction permits). The Department may condition innovative technology operation permits on duration, additional monitoring, reporting or other requirements as it deems necessary to protect the public health. The Department may revoke an innovative technology construction or operation permit if it finds the public water system is not complying with drinking water standards or the terms or conditions of the permit or if there is a significant change in the source water quality which could affect the reliability and operability of the treatment facility. Authorization for construction, operation or modifications obtained under an innovative technology permit will not extend beyond the expiration date of the permit.

Subchapter F. DESIGN AND CONSTRUCTION STANDARDS

§ 109.602. Acceptable design.

 (a) A public water system shall be designed to provide an adequate and reliable quantity and quality of water to the public. The design must ensure that the system will, upon completion, be capable of providing water that complies with the primary and secondary MCLs, MRDLs and treatment techniques established in Subchapters B, L and M (relating to MCLs, MRDLs or treatment technique requirements; long-term 2 enhanced surface water treatment rule; and additional requirements for groundwater sources) except as further provided in this section.

*  *  *  *  *

§ 109.605. Minimum treatment design standards.

 The level of treatment required for raw water depends upon the characteristics of the raw water, the nature of the public water system and the likelihood of contamination. The following minimum treatment design standards apply to new facilities and major changes to existing facilities:

*  *  *  *  *

 (3) For surface water and GUDI sources permitted after December 26, 2009, that are determined to be bin 2 or higher, the minimum treatment design for filtration and disinfection must also meet the requirements of §§ 109.1203 and 109.1204 (relating to bin classification and treatment technique requirements; and requirements for microbial toolbox components).

 (4) For community water systems using groundwater, the minimum treatment design standard for disinfection technologies utilized at the entry point is a total of 99.99% treatment of viruses.

 (5) For noncommunity water systems using groundwater with an E. coli-positive groundwater source sample collected under § 109.505(a)(3) (relating to requirements for noncommunity water systems), the minimum treatment design standard for disinfection technologies utilized at the entry point is a total of 99.99% treatment of viruses.

§ 109.611. Disinfection.

 Disinfection facilities shall be designed to provide the dosage rate and contact time prior to the first customer sufficient to provide a quality of water that complies with the microbiological MCL and the appropriate MRDL, specified in § 109.202 (relating to State MCLs, MRDLs and treatment technique requirements) and the treatment technique requirements in § 109.1302 (relating to treatment technique requirements).

[Continued on next Web Page]