Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Bulletin website includes the following: Rulemakings by State agencies; Proposed Rulemakings by State agencies; State agency notices; the Governor’s Proclamations and Executive Orders; Actions by the General Assembly; and Statewide and local court rules.

PA Bulletin, Doc. No. 10-942

NOTICES

DEPARTMENT OF ENVIRONMENTAL PROTECTION

Applications, Actions and Special Notices


APPLICATIONS

[40 Pa.B. 2674]
[Saturday, May 22, 2010]

THE CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT

APPLICATIONS FOR NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS

 This notice provides information about persons who have applied for a new, amended or renewed NPDES or WQM permit, a permit waiver for certain stormwater discharges or submitted a Notice of Intent (NOI) for coverage under a general permit. The applications concern, but are not limited to, discharges related to industrial, animal or sewage waste, discharges to groundwater, discharges associated with municipal separate storm sewer systems (MS4), stormwater associated with construction activities or concentrated animal feeding operations (CAFOs). This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92 and 40 CFR Part 122, implementing The Clean Streams Law (35 P. S. §§ 691.1—691.1001) and the Federal Clean Water Act.

Location Permit Authority Application Type or Category
Section I NPDES Renewals
Section II NPDES New or amendment
Section III WQM Industrial, sewage or animal waste; discharge into groundwater
Section IV NPDES MS4 individual permit
Section V NPDES MS4 permit waiver
Section VI NPDES Individual permit stormwater construction
Section VII NPDES NOI for coverage under NPDES general permits

 For NPDES renewal applications in Section I, the Department of Environmental Protection (Department) has made a tentative determination to reissue these permits for 5 years, subject to effluent limitations and monitoring and reporting requirements in their current permits, with appropriate and necessary updated requirements to reflect new and changed regulations and other requirements.

 For applications for new NPDES permits and renewal applications with major changes in Section II, as well as applications for MS4 individual permits and individual stormwater construction permits in Sections IV and VI, the Department, based upon preliminary reviews, has made a tentative determination of proposed effluent limitations and other terms and conditions for the permit applications. These determinations are published as proposed actions for comments prior to taking final actions.

 Unless indicated otherwise, the Environmental Protection Agency (EPA) Region III Administrator has waived the right to review or object to proposed NPDES permit actions under the waiver provision in 40 CFR 123.24(d).

 Persons wishing to comment on an NPDES application are invited to submit a statement to the regional office noted before an application within 30 days from the date of this public notice. Persons wishing to comment on a WQM permit application are invited to submit a statement to the regional office noted before the application within 15 days from the date of this public notice. Comments received within the respective comment periods will be considered in the final determinations regarding the applications. Comments should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based.

 The Department will also accept requests for a public hearing on applications. A public hearing may be held if the responsible office considers the public response significant. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. The Department will postpone its final determination until after a public hearing is held.

 Persons with a disability who require an auxiliary aid, service, including TDD users, or other accommodations to seek additional information should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.


I. NPDES Renewal Applications

Northeast Region: Water Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.

PA0011801, Industrial Waste, SIC Code 2819, Air Products & Chemicals, Inc., 7201 Hamilton Boulevard, Allentown, PA 18195-1526. Facility Name: Air Products & Chemicals. This existing facility is located in Glendon Borough, Northampton County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Industrial Waste.

 The receiving stream(s), Unnamed Tributary to Lehigh River, is located in State Water Plan watershed 2-C and is classified for aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.135 MGD.

Mass (lb/day) Concentration (mg/l)
AverageDailyAverageDailyDailyInstantaneous
Parameters Monthly Maximum Monthly Maximum Maximum Maximum
Flow (MGD) report report
pH (S.U.) 6.0 Minimum 9.0
Color (Pt-Co Units) 100
Temperature (° F) 110
Chemical Oxygen Demand Report
Total Suspended Solids 33.7 67.4 30 60 75
Total Dissolved Solids 1,300 2,600 3,250
Oil and Grease 15 30
Ammonia-Nitrogen 22.5 45 20 40 50
Fluoride Report
Total Organic Carbon 50

 In addition, the permit contains the following major special conditions:

 • Chemical additives.

 You may make an appointment to review the Department of Environmental Protection's files on this case by calling the File Review Coordinator at 570-826-5472.

 The EPA waiver is in effect.

NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name (Watershed #) EPA Waived Y/N?
PA0064220
(Sewage)
Twin County Joint Municipal Authority WWTP
309 Mahanoy Street
Nuremburg, PA 18241
Schuylkill County
North Union Township
Tomhicken Creek
5-E
Y

 Chesapeake Bay nutrient monitoring requirements for Ammonia Nitrogen, Kjeldahl Nitrogen, Nitrite-Nitrate as N, Total Nitrogen and Total Phosphorus are being added to this permit.


 Southcentral Region: Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.
NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name (Watershed #) EPA Waived Y/N ?
PA0085723
(Sew)
Exit II WWTP, Inc.
P. O. Box 1387
York, PA 17405-1387
York County
Springfield Township
Seaks Run
7-H
Y
PA0053091
(IW)
Giorgio Foods, Inc.
P. O. Box 96
1161 Park Road
Temple, PA 19560
Berks County
Maiden Creek Township
Willow Creek
3-B
Y
PA0247782
(IW)
Value Auto Salvage
13058 Greenwood Road
Huntingdon, PA 16652
Huntingdon County
Jackson Township
Standing Stone Creek
11-B
Y
PA0033995
(Sew)
County of Berks
633 Court Street
16th Floor
Reading, PA 19601-4322
Berks County
Bern Township
Plum Creek
3-C
Y

 Northcentral Regional Office: Water Management Program Manager, 208 West Third Street, Suite 101, Williamsport, PA 17701-6448. Phone: 570-327-0532.
NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name
(Watershed #)
EPA Waived Y/N?
PA0228931
(Sewage)
Kathy Weaver and Robert Martin SFTF
2495 Valley View Road
Bellefonte, PA 16823
Centre County
Benner Township
Unnamed Tributary of Buffalo Run
9-C
Y

II. Applications for New or Expanded Facility Permits, Renewal of Major Permits and EPA Nonwaived Permit Applications

Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.

PA0056081, Sewage, SIC Code 5812, Kevin P. Dougherty, 937 Worthington Mill Road, Wrightstown, PA 18940. Facility Name: Wycombe Pub & Grill. This existing facility is located in Wrightstown Township, Bucks County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Sewage.

 The receiving stream(s), Unnamed Tributary to Mill Creek, is located in State Water Plan watershed 2-F and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.00175 MGD.

Mass (lb/day) Concentration (mg/l)
AverageDailyAverageDailyInstantaneous
Parameters Monthly Maximum Minimum Monthly Maximum Maximum
Flow (MGD) Report
pH (S.U.) 6.0 9.0
Dissolved Oxygen 3.0
Total Residual Chlorine 0.5 1.2
CBOD5
 May 1 - Oct 31 10 20
 Nov 1 - Apr 30 20 40
Total Suspended Solids 10 20
Oil and Grease 15 30
Fecal Coliform
 (CFU/100 ml) 200
Geometric Mean
Nitrate-Nitrite as N Report
Ammonia-Nitrogen
 May 1 - Oct 31 3.0 6.0
 Nov 1 - Apr 30 9.0 18.0
Total Kjeldahl Nitrogen Report
Total Phosphorus Report

 In addition, the permit contains the following major special conditions:

 1. Abandon STP.

 2. Remedial Measures.

 3. No Stormwater.

 4. Dry Stream Discharge.

 5. Chlorine Minimization.

 6. Property Rights.

 7. Change of Ownership.

 8. Proper Sludge Disposal.

 9. IMAX limits to DMR.

 10. Laboratory Certification.

 You may make an appointment to review the Department of Environmental Protection's files on this case by calling the File Review Coordinator at 484-250-5910.

 The EPA waiver is in effect.

PA0056430, Industrial Waste, SIC Code 4226, 4613, Sunoco Partners Marketing & Terminals, LP, 4041 Market Street, Aston, PA 19014. Facility Name: Fort Mifflin Terminal. This existing facility is located in Tinicum Township, Delaware County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of stormwater.

 The receiving stream(s), Unnamed Tributary to Delaware River, is located in State Water Plan watershed 3-F and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on an average stormwater runoff.

Concentration (mg/l)
Average Instantaneous
ParametersMonthlyMaximum
Oil and Grease 15 30
TRPH 15 30

 In addition, the permit contains the following major special conditions:

 1. Remedial Measures.

 2. Change in Ownership.

 3. PPC Plan.

 4. Other Wastewater Discharges.

 5. Definitions.

 6. Laboratory Certification.

 7. Hydrostatic Test Water Discharge.

 You may make an appointment to review the Department of Environment Protection's files on this case by calling the File Review Coordinator at 484-250-5910.

 The EPA waiver is in effect.


 Southcentral Region: Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.

PA0044741, Industrial Waste, SIC Code 2033, Hanover Foods, Corp., P. O. Box 334, Hanover, PA 17331-334. Facility Name: Hanover Foods. This existing facility is located in Penn Township, York County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Industrial Waste.

 The receiving stream(s), Oil Creek and Unnamed Tributary to Oil Creek, is located in State Water Plan watershed 7-H and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.643 MGD.

Mass (lb/day) Concentration (mg/l)
AverageDailyAverageDailyInstantaneous
Parameters Monthly Maximum Minimum Monthly Maximum Maximum
Flow (MGD) Report Report XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0 XXX XXX 9.0
Dissolved Oxygen XXX XXX 5.0 XXX XXX XXX
Total Residual Chlorine XXX XXX XXX 0.1 XXX 0.3
CBOD5
 May 1 - Oct 31 53 105 XXX 10 20 XXX
 Nov 1 - Apr 30 160 320 XXX 30 60 XXX
Total Suspended Solids 53 105 XXX 10 20 XXX
Fecal Coliform
 (CFU/100 ml)
 May 1 - Sep 30 XXX XXX XXX 200
Geometric Mean
XXX XXX
 Oct 1 - Apr 30 XXX XXX XXX 2,000
Geometric Mean
XXX XXX
Ammonia-Nitrogen
 May 1 - Oct 31 8 16 XXX 1.5 3.0 XXX
 Nov 1 - Apr 30 24 48 XXX 4.5 9.0 XXX
Total Phosphorus (Interim) Report Report XXX Report Report XXX
Total Phosphorus (Final) 2.5 5.0 XXX 0.5 1.0 XXX

 The proposed monitoring requirements and, where appropriate, effluent limits for implementation of the Chesapeake Bay Tributary Strategy are as follows for Outfall 001.

Mass (lb/day) Concentration (mg/l)
Monthly
Parameters Monthly Annual Minimum Average Maximum
Ammonia-N Report Report XXX Report XXX
Kjeldahl-N Report XXX XXX Report XXX
Nitrate-Nitrite as N Report XXX XXX Report XXX
Total Nitrogen Report Report XXX Report XXX
Total Phosphorus Report Report XXX Report XXX
Net Total Nitrogen Report Report XXX XXX XXX
Net Total Phosphorus Report Report XXX XXX XXX

 You may make an appointment to review the Department of Environmental Protection's files on this case by calling the File Review Coordinator at 717-705-4732.

 The EPA waiver is in effect.

PA0261459, Sewage, SIC Code 6514, Anthony M. and Lori Todaro, 605 Roxbury Road, Newville, PA 17241. Facility Name: Todaro SFTF. This proposed facility is located in Upper Mifflin Township, Cumberland County.

 Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated Sewage.

 The receiving stream(s), Unnamed Tributary to Whisky Run, is located in State Water Plan watershed 7-B and is classified for Trout Stocking, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.0006 MGD.

Mass (lb/day) Concentration (mg/l)
AverageDailyAverageDailyInstantaneous
Parameters Monthly Maximum Minimum Monthly Maximum Maximum
Flow (MGD) Report Report
pH (S.U.) 6.0 9.0
Total Residual Chlorine Report
CBOD5 25 50
Total Suspended Solids 30 60
Fecal Coliform
 (CFU/100 ml)
 May 1 - Sep 30 200
Geometric Mean
 Oct 1 - Apr 30 2,000
Geometric Mean

 You may make an appointment to review the Department of Environmental Protection's files on this case by calling the File Review Coordinator at 717-705-4732.

 The EPA waiver is in effect.

Application No. PA 0042269, Sewage, Lancaster Area Sewer Authority, 130 Centerville Road, Lancaster, PA 17603. This facility is located in Manor Township, Lancaster County.

 Description of activity: The application is for an amendment of an NPDES permit for an existing discharge of treated sewage.

 The receiving stream, Dry Run, is in Watershed 7-J, and classified for warm water fishery, water supply, recreation and fish consumption. The nearest downstream public water supply intake for Safe Harbor Power Plant is located on the Susquehanna River, approximately 7 miles downstream. The discharge is not expected to affect the water supply.

 The proposed amendment would add a Part C condition allowing offsets for accepting septage:

 You may make an appointment to review the Department of Environmental Protection's files on this case by calling the File Review Coordinator at 717-705-4732.

 The EPA waiver is not in effect.


 Northcentral Region: Water Management Program Manager, 208 West Third Street, Williamsport, PA 17701.

PA 0233889, Troester Dairy, 175 Cannon Road, Mifflinburg, PA 17844. This proposed facility is located in Buffalo Township, Union County.

 Description of Proposed Activity: Dairy Farm.

 The receiving stream, UNTs of Buffalo Creek, is in the State Water Plan Buffalo Creek Watershed 10C and is classified for: Cold Water Fishery (CWF).

 The proposed effluent limits for the operation/activity include: Except for the chronic or catastrophic rainfall events defined as over the 25-year/24-hour rain storms, the CAFO individual permit is a nondischarge NPDES permit. Where applicable, compliance with 40 CFR Federal effluent limitation guidelines is required.

 In addition to the effluent limits, the permit contains the following major special conditions.

 1. Compliance with the Farm's Nutrient Management Plan.

 2. Compliance with the Farm's Preparedness, Prevention and Contingency Plan.

 3. Compliance with the Farm's Erosion and Sedimentation Control Plan for plowing and tilling.

 4. Erosion and Sedimentation Control Plan requirements for stormwater during construction activities.

 5. Animal mortality handling and disposing requirements.

 6. Certification requirements for manure storage facilities.

 7. Requirements for storage of feed and other raw materials.

 8. Best Management Practices requirements.

 The EPA waiver will not be in effect.


 Southwest Regional Office: Regional Manager, Water Management, 400 Waterfront Drive, Pittsburgh, PA 15222-4745, 412-442-4000.

PA0025941, Sewage, Canonsburg-Houston Joint Authority, 68 East Pike Street, Canonsburg, PA 15317. This application is for renewal of an NPDES permit to discharge treated sewage from Canonsburg-Houston Joint Authority Wastewater Treatment Plant in Cecil Township, Washington County.

 The following effluent limitations are proposed for discharge to the receiving waters, known as Chartiers Creek, which are classified as a warm water fishery with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the West View Municipal Authority located on the Ohio River.

Outfall 001: existing discharge, design flow of 5 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5
 May 1 to Oct 31 20 30 40
 Nov 1 to Apr 30 25 37.5 50
Suspended Solids 30 45 60
Ammonia Nitrogen
 May 1 to Oct 31 4.0 6.0 8.0
 Nov 1 to Apr 30 7.0 10.5 14.0
Fecal Coliform
 May 1 to Sep 30 200/100 ml as a Geometric Mean
 Oct 1 to Apr 30 2,000/100 ml as a Geometric Mean
Total Residual Chlorine 0.6 2.0
Dissolved Oxygen not less than 5.0 mg/l
pH not less than 6.0 nor greater than 9.0
CYANIDE, FREE 17 ug/l 27 ug/l

 The EPA waiver is not in effect.

PA0027111, Sewage, Municipal Sanitary Authority of the City of New Kensington, 120 Logans Ferry Road, New Kensington, PA 15068-2046. This application is for renewal of an NPDES permit to discharge treated sewage from Municipal Sanitary Authority of the City of New Kensington Wastewater Pollution Control Plant in City of New Kensington, Westmoreland County.

 The following effluent limitations are proposed for discharge to the receiving waters, known as Pucketa Creek, which are classified as a trout stock fishery with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the Oakmont Borough Municipal Authority.

Outfall 001: existing discharge, design flow of 6 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 25 37.5 50
Suspended Solids 30 45 60
Fecal Coliform
 May 1 to Sep 30 200/100 ml as a Geometric Mean
 Oct 1 to Apr 30 2,000/100 ml as a Geometric Mean
Total Residual Chlorine 1.0 3.3
pH not less than 6.0 nor greater than 9.0

 The EPA waiver is not in effect.

PA0096229, Sewage, Marianna-West Bethlehem Joint Sewerage Authority, P. O. Box 428, Marianna, PA 15345-0428. This application is for renewal of an NPDES permit to discharge treated sewage from Marianna-West Bethlehem Sewage Treatment Plant in West Bethlehem Township, Washington County.

 The following effluent limitations are proposed for discharge to the receiving waters, known as Ten Mile Creek, which are classified as a trout stock fishery with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the Tri-County Joint Municipal Authority located on the Monongahela River.

Outfall 001: existing discharge, design flow of 0.307 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5
 May 1 to Oct 31 20 30 40
 Nov 1 to Apr 30 25 37.5 50
Suspended Solids 30 45 60
Ammonia Nitrogen
 May 1 to Oct 31 5.0 7.5 10.0
 Nov 1 to Apr 30 15.0 22.5 30.0
Fecal Coliform
 May 1 to Sep 30 200/100 ml as a Geometric Mean
 Oct 1 to Apr 30 2,000/100 ml as a Geometric Mean
Total Residual Chlorine 0.6 2.0
Dissolved Oxygen not less than 4.0 mg/l
pH not less than 6.0 nor greater than 9.0

 The EPA waiver is in effect.

PA0204498, Sewage, Marion Center Area School District, Box 156, Route 403, Marion Center, PA 15759. This application is for renewal of an NPDES permit to discharge treated sewage from Rayne Township Elementary School Sewage Treatment Plant in Rayne Township, Indiana County.

 The following effluent limitations are proposed for discharge to the receiving waters, known as Swale to Unnamed Tributary of Crooked Creek, which are classified as a cold water fishery with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the Crooked Creek Intake.

Outfall 001: existing discharge, design flow of 0.00676 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 25 50
Suspended Solids 30 60
Ammonia Nitrogen
 May 1 to Oct 31 2.0 4.0
 Nov 1 to Apr 30 3.5 7.0
Fecal Coliform
 May 1 to Sep 30 200/100 ml as a Geometric Mean
 Oct 1 to Apr 30 2,000/100 ml as a Geometric Mean
Total Residual Chlorine 1.4 3.3
Dissolved Oxygen not less than 6.0 mg/l
pH not less than 6.0 nor greater than 9.0

 The EPA waiver is in effect.

PA0254215, Sewage, Rox Coal, Inc., P. O. Box 260, Friedens, PA 15541. This application is for issuance of an NPDES permit to discharge treated sewage from Horning Deep Mine STP in Stonycreek Township, Somerset County.

 The following effluent limitations are proposed for discharge to the receiving waters, known as Glades Creek, which are classified as a cold water fishery with existing and/or potential uses for aquatic life, water supply and recreation. The first downstream potable water supply intake from this facility is the Hooversville Municipal Authority.

Outfall 001: new discharge, design flow of 0.0035 mgd.

Concentration (mg/l)
Average Average Maximum Instantaneous
Parameter Monthly Weekly Daily Maximum
CBOD5 25 50
Suspended Solids 30 60
Fecal Coliform
 May 1 to Sep 30 200/100 ml as a Geometric Mean
 Oct 1 to Apr 30 2,000/100 ml as a Geometric Mean
Total Residual Chlorine 1.4 3.3
pH not less than 6.0 nor greater than 9.0

 The EPA waiver is in effect.


 Northwest Region: Water Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

PA0026832, Sewage, Borough of Ellwood City, 525 Lawrence Avenue, Ellwood City, PA 16117. This existing facility is located in Wayne Township, Lawrence County.

 Description of Proposed Activity: renewal of an existing NPDES permit to discharge treated sewage.

 The receiving stream, the Connoquenessing Creek, is in watershed 20-C and classified for: Warm Water Fishes, aquatic life, water supply and recreation.

 The proposed effluent limits for Outfall 001 are based on a design flow of 3.3 MGD.

Loadings Concentrations
AverageAverageAverageAverageInstantaneous
Parameters Monthly (lb/day) Weekly (lb/day) Monthly (mg/l) Weekly (mg/l) Maximum (mg/l)
Flow (MGD) XX XX
CBOD5 688 1,100 25 40 50
Total Suspended Solids 825 1,238 30 45 60
NH3-N
 (05/01 - 10/31) 440 16 32
 (11/01 - 04/30) 668 25 50
Fecal Coliform
 (05/01 - 09/30) 200/100 ml as a Geometric Mean
 (10/01 - 04/30) 2,000/100 ml as a Geometric Mean
Total Residual Chlorine 0.5 1.6
pH 6.0 to 9.0 Standard Units at all times

 XX—Monitor and report on monthly DMRs.

 The EPA waiver is not in effect.

PA0020257, Amendment No. 2, Sewage, Borough of Grove City, P. O. Box 110, Grove City, PA 16127-0110. This existing facility is located in Grove City Borough, Mercer County.

 Description of Proposed Activity: Amendment of an existing NPDES permit to discharge treated sewage.

 The receiving stream, the Wolf Creek, is in watershed 20-C and classified for: Cold Water Fishes, Migratory Fishes, aquatic life, water supply and recreation.

 The proposed effluent limits for Outfall 001 are based on a design flow of 3.0 MGD. Interim.

Loadings Concentrations
AverageAverageAverageAverageInstantaneous
Parameters Monthly (lb/day) Weekly (lb/day) Monthly (mg/l) Weekly (mg/l) Maximum (mg/l)
Flow (MGD) XX XX
CBOD5
 (5/1-10/31) 375 560 15 22.5 30
 (11/1-4/30) 625 1,000 25 40 50
Total Suspended Solids 750 1,125 30 45 60
NH3-N
 (05/01 - 10/31) 87.5 3.5 7
 (11/01 - 04/30) 250 10 21
Fecal Coliform
 (05/01 - 09/30) 200/100 ml as a Geometric Average
 (10/01 - 04/30) 3,600/100 ml as a Geometric Average
Total Residual Chlorine 0.39 1.27
Dissolved Oxygen minimum of 5 mg/l at all times
pH 6.0 to 9.0 Standard Units at all times

 The proposed effluent limits for Outfall 001 are based on a design flow of 3.525 MGD. Final.

Loadings Concentrations
AverageAverageAverageAverageInstantaneous
Parameters Monthly (lb/day) Weekly (lb/day) Monthly (mg/l) Weekly (mg/l) Maximum (mg/l)
Flow (MGD) XX XX
CBOD5
 (5/1-10/31) 588 882 20 30 40
 (11/1-4/30) 735 1,176 25 40 50
Total Suspended Solids 881 1,323 30 45 60
NH3-N
 (05/01 - 10/31) 118 4 8
 (11/01 - 04/30) 353 12 24
Fecal Coliform
 (05/01 - 09/30) 200/100 ml as a Geometric Average
 (10/01 - 04/30) 2,000/100 ml as a Geometric Average
Total Residual Chlorine 0.29 0.96
Dissolved Oxygen minimum of 4 mg/l at all times
pH 6.0 to 9.0 Standard Units at all times

 XX—Monitor and report on monthly DMRs.

 The EPA waiver is not in effect.


III. WQM Industrial Waste and Sewerage Applications under The Clean Streams Law (35 P. S. §§ 691.1—691.1001)

Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.

WQM Permit No. 0910401, Sewerage, Warwick Township Water & Sewer Authority, 1733 Township Greene, Jamison, PA 18929. This proposed facility is located in Warwick Township, Bucks County.

 Description of Action/Activity: Construction of a new sanitary pump station to serve the Ivyland Industrial Park.

Northeast Region: Water Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.

WQM Permit No. 4510401, Sewerage, Pocono Township Supervisors, P. O. Box 197, Tannersville, PA 18372. This proposed facility is located in Stroud Township and Stroudsburg Borough, Monroe County.

 Description of Proposed Action/Activity: This application is for construction and operation of a sewage force main to convey sewage from Pocono and Hamilton Townships through Stroud Township and Stroudsburg Borough to the regional treatment plant.

WQM Permit No. 5410402, Sewerage, Schuylkill County Municipal Authority, 221 South Centre Street, Pottsville, PA 17901. This proposed facility is located in Orwigsburg Borough and West Brunswick Township, Schuylkill County.

 Description of Proposed Action/Activity: This application is for construction and operation of gravity sewers, a pump station and force main to serve the Lee Development. The system will connect to Orwigsburg's existing sewerage system for conveyance and treatment.

Southcentral Region: Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.

WQM Permit No. 0610402, Sewerage, Womelsdorf Sewer Authority, 101 West High Street, Womelsdorf, PA 19567. This proposed facility is located in Heidelberg Township, Berks County.

 Description of Proposed Action/Activity: Seeking permit approval for the upgrade of the sludge process for the existing plant, improving the post-aeration by adding separate blowers, relocating chemical feed (Alum), and adding influent screening and grit removal, which will both be located in a proposed Headworks Building.

WQM Permit No. 5010401, Sewerage, Millerstown Borough Council, 44 North High Street, Millerstown, PA 17062. This proposed facility is located in Greenwood Township, Perry County.

 Description of Proposed Action/Activity: Seeking permit approval for the construction/operation of pumping station improvements and a sequencing batch reactor (SBR) wastewater treatment system.

WQM Permit No. 2810401, Sewerage, Franklin County General Authority, 5540 Coffey Avenue, Chambersburg, PA 17201. This proposed facility is located in Greene Township, Franklin County.

 Description of Proposed Action/Activity: Seeking permit approval for the upgrade to wastewater treatment plant to include new headworks, treatment unit, blower building and upgraded sludge management at their existing plant.

WQM Permit No. 2810402, Sewerage, Mont Alto Municipal Authority, P. O. Box 427, Mont Alto, PA 17237-0427. This proposed facility is located in Quincy Township, Franklin County.

 Description of Proposed Action/Activity: Seeking permit approval for the construction/operation for upgrades to the wastewater treatment facility.

WQM Permit No. 6710403, Sewerage, Penn Township, 20 Wayne Avenue, Hanover, PA 17331. This proposed facility is located in Penn Township, York County.

 Description of Proposed Action/Activity: Seeking permit approval for the construction/operation for a wastewater collection and conveyance system.

WQM Permit No. 2177201, Amendment 10-1, Industrial Waste, Body E. Diller, Inc., Diller Transfer Station, 6820 Wertzville Road, Enola, PA 17025-1032. This proposed facility is located in Silver Spring Township, Cumberland County.

 Description of Proposed Action/Activity: Seeking permit approval for upgrade to their wastewater treatment plant for Nitrification and Manganese removal.

Northwest Region: Oil and Gas Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481. Phone (814) 332-6860.

WQM Permit No. 1010601, Industrial Waste, Vavco, LLC, 101 Mahood Road, Suite 1, Butler, PA 16001. This proposed facility is located in Connoquenessing Township, Butler County.

 Description of Proposed Action/Activity: Construction of a Passive Water Treatment Plant to process wastewater from Stripper Oil Wells.

WQM Permit No. 4301201, Industrial Waste, Amendment No. 2, John Koller & Son, Inc., 1734 Perry Highway, Fredonia, PA 15124. This proposed facility is located in Fairview Township, Mercer County.

 Description of Proposed Action/Activity: Amendment to the Water Quality permit for the sludge dewatering filter replacement.

WQM Permit No. WQG018752, Sewerage, Seth Michaels, 840 Sewickley Street, Ellwood City, PA 16117. This proposed facility is located in Wayne Township, Lawrence County.

 Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant.

WQM Permit No. WQG018750, Sewerage, Tom Barnes, 190 Southbrook Drive, New Castle, PA 16105. This proposed facility is located in Neshannock Township, Lawrence County.

 Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant.

WQM Permit No. WQG018745, Sewerage, Norman Sharp, 298 Orangeville Road, Greenville, PA 16125. This proposed facility is located in West Salem Township, Mercer County.

 Description of Proposed Action/Activity: A Single Residence Sewage Treatment Plant.

WQM Permit No. 2071401, Sewage, Amendment No. 1, Titusville Estates, LLC, 21321 Campbell Road, Titusville, PA 16354. This existing facility is located in Oil Creek Township, Crawford County.

 Description of Proposed Action/Activity: This permit approves the amendment of Water Quality Management part II permit for sewage wastewater facilities serving a mobile home park. An aerated sludge holding tank will be constructed by adding a wall inside the aeration tank, reducing its volume down to 9,000 gallons. The original design also included (2) intermittent sand filters which are being removed as listed treatment units from this permit.


IV. NPDES Applications for Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)


V. Applications for NPDES Wavier Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)


VI. NPDES Individual Permit Applications for Discharges of Stormwater Associated with Construction Activities

Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI01
091003
James Baker
1748 Central Park
Orefield, PA 18069
Bucks Springfield Township Cooks Creek
EV-MF

Northeast Region: Watershed Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.

Northampton County Conservation District: 14 Gracedale Avenue, Greystone Building, Nazareth, PA 18064-9211, 610-746-1971.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI024810001 Department of Transportation
1002 Hamilton Street
Allentown, PA 18101
Northampton Williams Township Frya Run
HQ-CWF, MF
PAI024810004 Arcadia East Associates No. 1, LP and Arcadia East Associates No. 1, Inc.
100 Gateway Drive
Suite 310
Allentown, PA 18017
Northampton East Allen Township Monocacy Creek
HQ-CWF, MF

Pike County Conservation District: 556 Route 402, Suite 1, Hawley, PA 18428, 570-226-8220.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI025210004 Lehman Township
Attn: John Sivick
R. R. 4
Box 4000
Bushkill, PA 18324
Pike Lehman Township Saw Creek
HQ-CWF, MF

Northcentral Region: Watershed Management Program Manager, 208 West Third Street, Williamsport, PA 17701.

Lycoming County Conservation District: 542 County Farm Road, Suite 202, Montoursville, PA 17754, (570) 433-3003.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI044110002 Richard Hannan, Jr.
2029 Lycoming Creek Road
Williamsport, PA 17701
Lycoming Loyalsock Township Mill Creek
TSF/MF

Southwest Region: Watershed Management Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

Washington County Conservation District, 602 Courthouse Square, Washington, PA 15301, (724-228-6774).

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAI056310005 Majestic Hills, LLC
3625 Washington Pike
Bridgeville, PA 15017
Washington North Strabane Township UNT to Little Chartiers Creek
HQ-WWF

VII. List of NOIs for NPDES and/or Other General Permit Types

PAG-12 Concentrated Animal Feeding Operations (CAFOs)
PAG-13 Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)

[Continued on next Web Page]



No part of the information on this site may be reproduced for profit or sold for profit.

This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.