Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Bulletin website includes the following: Rulemakings by State agencies; Proposed Rulemakings by State agencies; State agency notices; the Governor’s Proclamations and Executive Orders; Actions by the General Assembly; and Statewide and local court rules.

PA Bulletin, Doc. No. 10-104

PROPOSED RULEMAKING

ENVIRONMENTAL
QUALITY BOARD

[ 25 PA. CODE CH. 129 ]

Large Appliance and Metal Furniture Surface Coating Processes

[40 Pa.B. 420]
[Saturday, January 16, 2010]

 The Environmental Quality Board (Board) proposes to amend Chapter 129 (relating to standards for sources) to read as set forth in Annex A.

 The proposed rulemaking would amend Chapter 129 to limit emissions of volatile organic compounds (VOCs) from the use and application of coatings and cleaning materials in large appliance and metal furniture surface coating processes. The proposal would add § 129.52a (relating to control of VOC emissions from large appliance and metal furniture surface coating processes) and amend §§ 129.51 and 129.52 (relating to general; and surface coating processes).

 This proposal was adopted by the Board at its meeting on November 17, 2009.

A. Effective Date

 This proposed rulemaking will be effective upon final-form publication in the Pennsylvania Bulletin.

B. Contact Persons

 For further information, contact Arleen J. Shulman, Chief, Division of Air Resource Management, P. O. Box 8468, Rachel Carson State Office Building, Harrisburg, PA 17105-8468, (717) 772-3436, or Kristen Campfield Furlan, Assistant Counsel, Bureau of Regulatory Counsel, P. O. Box 8464, Rachel Carson State Office Building, Harrisburg, PA 17105-8464, (717) 787-7060. Information regarding submitting comments on this proposal appears in Section J of this preamble. Persons with a disability may use the Pennsylvania AT&T Relay Service by calling (800) 654-5984 (TDD users) or (800) 654-5988 (voice users). This proposal is available electronically through the Department of Environmental Protection's (Department) web site at www.depweb.state.pa.us (Select Public Participation).

C. Statutory Authority

 This proposed rulemaking is authorized under section 5 of the Air Pollution Control Act (APCA) (35 P. S. § 4005), which in subsection (a)(1) grants the Board the authority to adopt rules and regulations for the prevention, control, reduction and abatement of air pollution in this Commonwealth, and which in subsection (a)(8) grants the Board the authority to adopt rules and regulations designed to implement the provisions of the Clean Air Act (CAA).

D. Background and Purpose

 The purpose of this proposed rulemaking is to reduce VOC emissions from large appliance and metal furniture surface coating operations. VOCs are a precursor for ozone formation. Ground-level ozone is not emitted directly by surface coatings to the atmosphere, but is formed by a photochemical reaction between VOCs and nitrogen oxides (NOx) in the presence of sunlight. The proposed rulemaking adopts the emission limits and other requirements of the United States Environmental Protection Agency's (EPA's) 2007 Control Techniques Guidelines (CTGs) for large appliance coatings and metal furniture coatings in order to meet Federal CAA requirements.

 The EPA is responsible for establishing National Ambient Air Quality Standards (NAAQS) for six criteria pollutants considered harmful to public health and the environment: ozone, particulate matter, NOx, carbon monoxide, sulfur dioxide and lead. The CAA established two types of NAAQS: primary standards, limits set to protect public health; and secondary standards, limits set to protect public welfare, including protection against visibility impairment and from damage to animals, crops, vegetation and buildings. The EPA has established primary and secondary ozone NAAQS to protect public health and welfare.

 When ground-level ozone is present in concentrations in excess of the Federal health-based 8-hour NAAQS for ozone, public health and welfare are adversely affected. Ozone exposure correlates to increased respiratory disease and higher mortality rates. Ozone can inflame and damage the lining of the lungs. Within a few days, the damaged cells are shed and replaced. Over a long time period, lung tissue may become permanently scarred, resulting in permanent loss of lung function and a lower quality of life. When ambient ozone levels are high, more people with asthma have attacks that require a doctor's attention or use of medication. Ozone also makes people more sensitive to allergens including pet dander, pollen and dust mites, all of which can trigger asthma attacks.

 The EPA has concluded that there is an association between high levels of ambient ozone and increased hospital admissions for respiratory ailments including asthma. While children, the elderly and those with respiratory problems are most at risk, even healthy individuals may experience increased respiratory ailments and other symptoms when they are exposed to high levels of ambient ozone while engaged in activities that involve physical exertion. High levels of ozone also affect animals in ways similar to humans.

 In addition to causing adverse human and animal health effects, the EPA has concluded that ozone affects vegetation and ecosystems, leading to reductions in agricultural crop and commercial forest yields by destroying chlorophyll; reduced growth and survivability of tree seedlings; and increased plant susceptibility to disease, pests and other environmental stresses, including harsh weather. In long-lived species, these effects may become evident only after several years or even decades and have the potential for long-term adverse impacts on forest ecosystems. Ozone damage to the foliage of trees and other plants can decrease the aesthetic value of ornamental species used in residential landscaping, as well as the natural beauty of parks and recreation areas. Through deposition, ground-level ozone also contributes to pollution in the Chesapeake Bay. The economic value of some welfare losses due to ozone can be calculated, such as crop yield loss from both reduced seed production and visible injury to some leaf crops, including lettuce, spinach and tobacco, as well as visible injury to ornamental plants, including grass, flowers and shrubs. Other types of welfare loss may not be quantifiable, such as the reduced aesthetic value of trees growing in heavily visited parks.

 High levels of ground-level ozone can also cause damage to buildings and synthetic fibers, including nylon, and reduced visibility on roadways and in natural areas. The implementation of additional measures to address ozone air quality nonattainment in this Commonwealth is necessary to protect the public health and welfare, animal and plant health and welfare and the environment.

 In July 1997, the EPA established primary and secondary ozone standards at a level of 0.08 parts per million (ppm) averaged over 8 hours. See 62 FR 38855 (July 18, 1997). In 2004, the EPA designated 37 counties in this Commonwealth as 8-hour ozone nonattainment areas for the 1997 8-hour ozone NAAQS see 69 FR 2385 at p. 2393 (April 30, 2004). The areas in which the 1997 standard has been attained are required to have permanent and enforceable control measures to ensure violations do not occur for the next decade. The Commonwealth must demonstrate that the two areas currently not attaining the 1997 standard will meet the 1997 standard as expeditiously as practicable. If these two areas do not attain the standard during the 2009 ozone season, additional reductions will be required.

 In March 2008, the EPA lowered the standards to 0.075 ppm averaged over 8 hours to provide even greater protection for children, other at-risk populations and the environment against the array of ozone-induced adverse health and welfare effects. See 73 FR 16436 (March 27, 2008). The EPA is reconsidering the March 2008 ozone NAAQS and on January 7, 2010 announced a proposal to set a more protective 8-hour ozone standard between 0.060 and 0.070 ppm. The final revised ozone NAAQS is expected in August 2010.

 There are no Federal statutory or regulatory limits for VOC emissions from large appliance and metal furniture surface coating operations. State regulations to control VOC emissions from large appliance and metal furniture surface coating operations are required under Federal law, however, and will be reviewed by the EPA for whether they meet the ''reasonably available control technology'' (RACT) requirements of the CAA and its implementing regulations. Consumer and Commercial Products; Control Techniques Guidelines in lieu of Regulations for Paper, Film, and Foil Coatings; Metal Furniture Coatings; and Large Appliance Coatings, 72 FR 57215, 57218 (October 9, 2007).

 Section 172(c)(1) of the CAA provides that State Implementation Plans (SIPs) for nonattainment areas must include ''reasonably available control measures,'' including RACT, for sources of emissions. 42 U.S.C.A. § 7502(c)(1). Section 182(b)(2) of the CAA provides that for moderate ozone nonattainment areas, states must revise their SIPs to include RACT for sources of VOC emissions covered by a CTG document issued by the EPA prior to the area's date of attainment. 42 U.S.C.A. § 7511a(b)(2). More importantly, section 184(b)(1)(B) of the CAA requires that states in the Ozone Transport Region (OTR), including the Commonwealth, submit a SIP revision requiring implementation of RACT for all sources of VOC emissions in the state covered by a specific CTG. 42 U.S.C.A. § 7511c(b)(1)(B).

 Section 183(e) of the CAA directs the EPA to list for regulation those categories of products that account for at least 80% of the VOC emissions from consumer and commercial products in ozone nonattainment areas. 42 U.S.C.A. § 7511b(e). Section 183(e)(3)(C) of the CAA further provides that the EPA may issue a CTG in place of a National regulation for a product category where the EPA determines that the CTG will be ''substantially as effective as regulations'' in reducing emissions of VOC in ozone nonattainment areas. 42 U.S.C.A. § 7511b(e)(3)(C).

 In 1995, the EPA listed large appliance coatings and metal furniture coatings on its section 183(e) list and, in 2007, issued CTGs for these two product categories. See 60 FR 15264 (March 23, 1995) and 72 FR 57215 (October 9, 2007). In the 2007 notice, the EPA determined that the CTGs would be substantially as effective as National regulations in reducing VOC emissions from these product categories in ozone nonattainment areas. 72 FR at p. 57220.

 The CTG provides states with the EPA's recommendation of what constitutes RACT for the covered category. States can use the recommendations provided in the CTG to inform their own determination as to what constitutes RACT for VOC emissions from the covered category. State air pollution control agencies are free to implement other technically sound approaches that are consistent with the CAA requirements and the EPA's implementing regulations or guidelines.

 The Department has reviewed the recommendations included in the 2007 CTGs for large appliance and metal furniture coatings for their applicability to the ozone reduction measures necessary for this Commonwealth. The Department has determined that the measures provided in the CTGs for large appliance and metal furniture coatings are appropriate to be implemented in this Commonwealth as RACT for this category.

 This rulemaking, if adopted as a final rule, would assist in reducing VOC emissions locally as well as reducing the transport of VOC emissions and ground-level ozone to downwind states. Adoption of VOC emission requirements for large appliance and metal furniture surface coating operations is part of the Commonwealth's strategy, in concert with other OTR jurisdictions, to further reduce transport of VOC ozone precursors and ground-level ozone throughout the OTR to attain and maintain the 8-hour ozone NAAQS. The proposed rulemaking is required under the CAA and is reasonably necessary to attain and maintain the health-based 8-hour ozone NAAQS in this Commonwealth. When final, this rulemaking will be submitted to the EPA as a revision to the SIP.

 The concepts of the proposed rulemaking were discussed with the Air Quality Technical Advisory Committee (AQTAC) at its October 30 and December 11, 2008, meetings. The proposed rulemaking was discussed with the AQTAC on May 28, 2009. The AQTAC concurred with the Department's recommendation to present the proposed amendments to the Board for approval for publication as a proposed rulemaking. The Department also consulted with the Citizens Advisory Council on July 21, 2009, and with the Small Business Compliance Advisory Committee on October 22, 2008, and April 22 and July 22, 2009.

E. Summary of Regulatory Requirements

 The proposed rulemaking would amend § 129.51(a) to extend its coverage to large appliance and metal furniture surface coating processes covered by this proposed rulemaking, as well as to paper, film and foil surface coating processes and flat wood paneling surface coating processes, which are covered in parallel rulemakings. Section 129.51(a) provides an alternative method for owners and operators of facilities to achieve compliance with air emission limits.

 The proposed rulemaking would amend § 129.52 by adding subsection (i). Section 129.52 specifies requirements and emission limits for various surface coating processes. The amendment in this proposed rulemaking would clarify in new subsection (i) that the requirements and limits already specified in § 129.52 for metal furniture coatings, large appliance coatings and paper coatings are superseded by the requirements and limits that will be adopted in this proposed rulemaking and in the proposed rulemaking for paper, film and foil surface coating processes.

 One emission limit is expressed in § 129.52 for large appliance coatings and one emission limit is expressed for metal furniture coatings, whereas in the CTGs separate emission limits are expressed for eight different coating types within each of these two categories. Several of the limits in the CTGs are more stringent and several are less stringent than the existing limits expressed in § 129.52. As is explained in the discussion, as follows, regarding Tables I and II (relating to emission limits of VOCs for large appliance surface coatings; and emission limits of VOCs for metal furniture surface coatings), the more stringent limits are adopted in this proposed rulemaking.

 The proposed rulemaking would add § 129.52a to regulate VOC emissions from large appliance and metal furniture surface coating processes. The applicability of this new section is described in subsection (a), which establishes that § 129.52a applies to the owner and operator of a large appliance or metal furniture surface coating process if the total actual VOC emissions from all large appliance or metal furniture surface coating operations, including related cleaning activities, at the facility are equal to or greater than 15 pounds (6.8 kilograms) per day or 2.7 tons (2,455 kilograms) per 12-month rolling period, before consideration of controls. The emission limits and other requirements of this section supersede the emission limits and other requirements of § 129.52. Basing the applicability on a 12-month rolling period is generally considered to be more stringent than basing it on a calendar year, as in § 129.52, but is consistent with the CTGs.

 Proposed subsection (b) explains that the requirements of § 129.52a supersede the requirements of a RACT permit for VOC emissions from a large appliance or metal furniture surface coating operation already issued to the owner or operator of a source subject to § 129.52a, except to the extent the RACT permit contains more stringent requirements.

 Proposed subsection (c) establishes VOC emission limits. Beginning January 1, 2011, a person may not cause or permit the emission into the outdoor atmosphere of VOCs from a large appliance or metal furniture surface coating process, unless: (1) the VOC content of each as applied coating is equal to or less than the limit specified in one of the two tables in § 129.52a; or (2) the overall weight of VOCs emitted to the atmosphere is reduced through the use of vapor recovery, incineration or another method that is acceptable under § 129.51(a). The second option also addresses the overall efficiency of a control system.

 Proposed subsection (d) identifies daily records that must be kept to demonstrate compliance with § 129.52a, including records of parameters and VOC content of each coating, thinner, component and cleaning solvent, as supplied, and the VOC content of each as applied coating or cleaning solvent.

 Proposed subsection (e) requires that the records be maintained for 2 years and submitted to the Department on request.

 Under proposed subsection (f), an owner or operator subject to § 129.52a may not cause or permit the emission into the outdoor atmosphere of VOCs from the application of large appliance or metal furniture surface coatings, unless the coatings are applied using electrostatic coating, roller coating, flow coating, dip coating (including electrodeposition), high volume-low pressure (HVLP) spray, or brush coating. An owner or operator may use another coating application method if a request is submitted in writing that demonstrates that the method is capable of achieving a transfer efficiency equivalent to or better than that achieved by the other methods listed in subsection (f), and is approved in writing by the Department prior to use.

 Proposed subsection (g) exempts stencil coatings, safety-indicating coatings, solid-film lubricants, electric-insulating coatings, thermal-conducting coatings, touch-up and repair coatings and coating applications using hand-held aerosol cans from the VOC coating content limits in Tables I and II of proposed § 129.52a. Subsection (g) also exempts a coating used exclusively for determining product quality and commercial acceptance and other small quantity coatings, if the quantity of coating used does not exceed 50 gallons per year for a single coating and a total of 200 gallons per year for all coatings combined for the facility and if the owner or operator of the facility requests, in writing, and the Department approves, in writing, the exemption prior to use of the coating.

 Proposed subsection (h) establishes work practices that an owner or operator of a large appliance or metal furniture surface coating process subject to § 129.52a must comply with for coating-related activities.

 Proposed subsection (i) establishes work practices that an owner or operator of a large appliance or metal furniture surface coating process subject to § 129.52a must comply with for cleaning materials.

 Proposed Table I establishes emission limits for VOCs for eight types of large appliance surface coatings, expressed in weight of VOC per volume of coating solids (kilograms per liter (kg/l) or pounds per gallon (lb/gal)), as applied. Limits are prescribed for coatings that are baked and coatings that are air dried. The emission limits for the following coating types are taken from the large appliance coatings CTG: Baked (kg/l and lb/gal)—''General, one component'' and ''General, multi-component''; Air Dried (kg/l)—''General, one component''; and Air Dried (lb/gal)—''General, one component,'' ''General, multi-component'' and ''Extreme high gloss.'' The emission limits for Air Dried (kg/l)—''General, multi-component'' and ''Extreme high gloss'' are taken from both the CTG and the emission limit for ''large appliance coatings'' in § 129.52, as they are the same in both places. The remaining emission limits are taken from § 129.52 because the limit in § 129.52 is more stringent than the recommended limits in the CTG. Whenever the limit in § 129.52 is the same as or more stringent than the recommended limit in the CTG, the limit in § 129.52 is listed due to the CAA prohibition against backsliding from existing emission control requirements.

 Proposed Table II establishes emission limits for VOCs for eight types of metal furniture surface coatings, expressed in weight of VOC per volume of coating solids (kg/l or lb/gal), as applied. Limits are prescribed for coatings that are baked and coatings that are air dried. The emission limits from the following coating types are taken from the metal furniture CTG: Baked (kg/l and lb/gal)—''General, one component'' and ''General, multi-component''; and Air Dried (kg/l and lb/gal)—''General, one component,'' ''General, multi-component'' and ''Extreme high gloss.'' The emission limits for Baked (kg/l)—''Extreme high gloss,'' ''Extreme performance,'' ''Heat resistant'' and ''Solar absorbent'' are taken from both the CTG and the emission limit for ''metal furniture coatings'' in § 129.52, as they are the same in both places. The remaining emission limits are taken from § 129.52 because the limit in § 129.52 is more stringent than the recommended limits in the CTG. Whenever the limit in § 129.52 is the same as or more stringent than the recommended limit in the CTG, the limit in § 129.52 is listed due to the CAA prohibition against backsliding from existing emission control requirements.

F. Benefits, Costs and Compliance

Benefits

 Implementation of the proposed control measure would benefit the health and welfare of the approximately 12 million humans, animals, crops, vegetation and natural areas of this Commonwealth by reducing emissions of VOCs, which are precursors to ground-level ozone air pollution. Although the proposed amendments are designed primarily to address ozone air quality, the reformulation or substitution of coating products to meet the VOC content limits applicable to users may also result in reduction of hazardous air pollutant (HAP) emissions, which are also a serious health threat.

 The proposed rulemaking provides as one compliance option that coatings used on or applied to large appliance or metal furniture products manufactured in this Commonwealth meet specified limits for VOC content, usually through substitution of low VOC-content solvents or water for the high VOC-content solvents. The reduced levels of high VOC-content solvents would also benefit water quality through reduced loading on water treatment plants and in reduced quantities of high VOC-content solvents leaching into the ground. Owners and operators of affected large appliance and metal furniture coating process facilities may also reduce VOC emissions through the use of add-on controls, or a combination of complying coatings and add-on controls.

 In this Commonwealth approximately four large appliance surface coating operations combine to emit an estimated total of 18.2 tons of VOCs per year; about 16 metal furniture surface coating operations combine to emit an estimated total of 50.33 tons of VOCs per year.

 The EPA estimates that implementation of the recommended control options for large appliance coatings processes will result in approximately a 30% reduction in VOC emissions. The maximum anticipated additional annual VOC reductions from the large appliance surface coating facilities as a result of this rulemaking is approximately 5.5 tons (18.2 tons x 30%).

 The EPA estimates that implementation of the recommended control options for metal furniture coatings processes will result in approximately a 35% reduction in VOC emissions. The maximum anticipated additional annual VOC reductions from the metal furniture surface coating facilities as a result of this rulemaking is approximately 17.6 tons (50.33 tons x 35%).

Compliance Costs

 The costs of complying with the proposed amendments include the cost of using alternative product formulations, such as low-VOC or water-based coatings, and the cost of using add-on controls. The facility owner or operator would be given the flexibility to choose controls. Based on information provided by the EPA in the large appliance coating CTG, the cost effectiveness of reducing VOC emissions from large appliance surface coating operations is estimated to be $500 per ton of VOC reduced. This estimate is based on the use of low VOC-content coatings for control. The estimated annual costs for the owners or operators of the affected large appliance surface coating facilities in this Commonwealth, combined, is $2,750 (5.5 tons VOC reduced x $500 per ton reduced).

 Similarly, based on information provided by the EPA in the metal furniture coating CTG, the cost effectiveness of reducing VOC emissions from metal furniture surface coating operations is estimated to be $200 per ton of VOC reduced. This estimate is based on the use of low VOC-content coatings for control. The estimated annual costs for the owners or operators of the affected metal furniture coating facilities in this Commonwealth, combined, is $3,520 (17.6 tons VOC reduced x $200 per ton reduced).

 The potential total annual costs to the regulated industry of $2,750 for large appliance surface coating operations and $3,520 for metal furniture surface coating operations are negligible compared to the improved health and environmental benefits that would be gained from this proposed rulemaking.

 The implementation of the work practice requirements for cleaning materials is expected to result in a net cost savings. The recommended work practices should reduce the amount of cleaning materials used by reducing the amount of cleaning materials lost to evaporation, spillage and waste.

Compliance Assistance Plan

 The Department plans to educate and assist the public and regulated community in understanding the newly revised requirements and how to comply with them. This will be accomplished through the Department's ongoing compliance assistance program.

Paperwork Requirements

 The owners and operators of affected large appliance or metal furniture surface coating operations would be required to keep daily operational records of information for coatings and cleaning solvents sufficient to demonstrate compliance, including identification of materials, VOC content and volumes used. The records must be maintained for 2 years and submitted to the Department upon request. Persons claiming the small quantity exemption or use of exempt coating would be required to keep records demonstrating the validity of the exemption. Persons seeking to comply through the use of add-on controls would be required to meet the applicable reporting requirements specified in Chapter 139 (relating to sampling and testing).

G. Pollution Prevention

 The Federal Pollution Prevention Act of 1990 (42 U.S.C.A. §§ 13101—13109) established a National policy that promotes pollution prevention as the preferred means for achieving State environmental protection goals. The Department encourages pollution prevention, which is the reduction or elimination of pollution at its source, through the substitution of environmentally friendly materials, more efficient use of raw materials and the incorporation of energy efficiency strategies. Pollution prevention practices can provide greater environmental protection with greater efficiency because they can result in significant cost savings to facilities that permanently achieve or move beyond compliance. This proposal has incorporated the following pollution prevention incentives:

 The proposed amendments will assure that the citizens and the environment of this Commonwealth experience the benefits of reduced emissions of VOCs and HAPs from large appliance and metal furniture surface coating processes. Although the proposed amendments are designed primarily to address ozone air quality, the reformulation or substitution of coating products to meet the VOC content limits applicable to users may also result in reduction of HAP emissions, which are also a serious health threat. The proposed rulemaking provides as one compliance option that coatings used on or applied to large appliance or metal furniture products manufactured in this Commonwealth meet specified limits for VOC content, usually through substitution of low VOC-content solvents or water for the high VOC-content solvents. The reduced levels of high VOC-content solvents would also benefit water quality through reduced loading on water treatment plants and in reduced quantities of high VOC-content solvents leaching into the ground. Owners and operators of affected large appliance and metal furniture surface coating process facilities may also reduce VOC emissions through the use of add-on controls, or a combination of complying coatings and add-on controls.

H. Sunset Review

 These regulations will be reviewed in accordance with the sunset review schedule published by the Department to determine whether the regulations effectively fulfill the goals for which they were intended.

I. Regulatory Review

 Under section 5(a) of the Regulatory Review Act (71 P. S. § 745.5(a)), on January 5, 2010, the Department submitted a copy of these proposed amendments to the Independent Regulatory Review Commission (IRRC) and the House and Senate Environmental Resources and Energy Committees (Committees). In addition to submitting the proposed amendments, the Department has provided IRRC and the Committees with a copy of a detailed Regulatory Analysis Form prepared by the Department. A copy of this material is available to the public upon request.

 Under section 5(g) of the Regulatory Review Act, IRRC may convey any comments, recommendations or objections to the proposed rulemaking within 30 days of the close of the public comment period. The comments, recommendations or objections shall specify the regulatory review criteria that have not been met. The Regulatory Review Act specifies detailed procedures for review of these issues by the Department, the General Assembly and the Governor prior to final-form publication of the regulations.

J. Public Comments

Written Comments—Interested persons are invited to submit comments, suggestions or objections regarding the proposed rulemaking to the Environmental Quality Board, P. O. Box 8477, Harrisburg, PA 17105-8477 (express mail: Rachel Carson State Office Building, 16th Floor, 400 Market Street, Harrisburg, PA 17101-2301). Comments submitted by facsimile will not be accepted. Comments, suggestions or objections must be received by the Board by March 22, 2010. Interested persons may also submit a summary of their comments to the Board. The summary may not exceed one page in length and must also be received by the Board by March 22, 2010. The one-page summary will be provided to each member of the Board in the agenda packet distributed prior to the meeting at which the final-form regulation will be considered.

Electronic Comments—Comments may be submitted electronically to the Board at RegComments@state.pa.us and must also be received by the Board by March 22, 2010. A subject heading of the proposal and a return name and address must be included in each transmission. If an acknowledgement of electronic comments is not received by the sender within 2 working days, the comments should be retransmitted to the Board to ensure receipt.

K. Public Hearings

 The Board will hold public hearings in Pittsburgh, Harrisburg and Norristown for the purpose of accepting comments on this proposed rulemaking. The hearings will be held as follows:

February 16, 2010
1 p.m.
Department of Environmental  Protection
Southwest Regional Office
Waterfront Conference Room A and B
400 Waterfront Drive
Pittsburgh, PA 15222-4745
February 17, 2010
1 p.m.
Department of Environmental  Protection
Rachel Carson State Office Building
Conference Room 105
400 Market Street
Harrisburg, PA 17105
February 18, 2010
1 p.m.
Department of Environmental  Protection
Southeast Regional Office
Delaware Conference Room
2 East Main Street
Norristown, PA 19401

 Persons wishing to present testimony at a hearing are requested to contact the Environmental Quality Board, P. O. Box 8477, Harrisburg, PA 17105-8477, (717) 787-4526, at least 1 week in advance of the hearing to reserve a time to present testimony. Oral testimony is limited to 10 minutes for each witness. Witnesses are requested to submit three written copies of their oral testimony to the hearing Chairperson to aid in transcribing the hearing. Organizations are limited to designating one witness to present testimony on their behalf at each hearing.

 Persons in need of accommodations as provided for in the Americans With Disabilities Act of 1990 should contact the Board at (717) 787-4526, or through the Pennsylvania AT&T Relay Service at (800) 654-5984 (TDD), or (800) 654-5988 (voice users) to discuss how the Board may accommodate their needs.

JOHN HANGER, 
Chairperson

Fiscal Note: 7-449. No fiscal impact; (8) recommends adoptions.

Annex A

TITLE 25. ENVIRONMENTAL PROTECTION

PART I. DEPARTMENT OF ENVIRONMENTAL PROTECTION

Subpart C. PROTECTION OF NATURAL RESOURCES

ARTICLE III. AIR RESOURCES

CHAPTER 129. STANDARDS FOR SOURCES

SOURCES OF VOCs

§ 129.51. General.

 (a) Equivalency. Compliance with §§ 129.52, 129.52a, 129.52b (Editor's Note: The Department proposed to add § 129.52b at 39 Pa.B. 6460 (November 7, 2009), 129.52c (Editor's Note: The Department proposed to add § 129.52c at 39 Pa.B. 6061, 6067 (October 17, 2009.) and 129.54—129.73 may be achieved by alternative methods if the following exist:

*  *  *  *  *

 (3) Compliance by a method other than the use of a low VOC coating or ink which meets the applicable emission limitation in §§ 129.52, 129.52a, 129.52b, 129.52c, 129.67 and 129.73 [(relating to surface coating processes; graphic arts systems; and aerospace manufacturing and rework)] shall be determined on the basis of equal volumes of solids.

*  *  *  *  *

 (6) The alternative compliance method is incorporated into a plan approval or operating permit, or both, reviewed by the EPA, including the use of an air cleaning device to comply with § 129.52, § 129.52a, § 129.52b, § 129.52c, § 129.67, § 129.68(b)(2) and (c)(2) or § 129.73.

*  *  *  *  *

§ 129.52. Surface coating processes.

*  *  *  *  *

(i) Beginning January 1, 2011, the requirements and limits for metal furniture coatings, large appliance coatings and paper coatings are superseded by the requirements and limits in §§ 129.52a and 129.52b (Editor's Note: The Department proposed to add § 129.52b at 39 Pa.B. 6460 (November 7, 2009) (relating to control of VOC emissions from large appliance and metal furniture surface coating processes; and control of VOC emissions from paper, film and foil surface coating processes), respectively.

*  *  *  *  *

 (Editor's Note: Section 129.52a is new and printed in regular type to enhance readability.)

§ 129.52a. Control of VOC emissions from large appliance and metal furniture surface coating processes.

 (a) Applicability. This section applies as follows:

 (1) This section applies to the owner and operator of a large appliance or metal furniture surface coating process if the total actual VOC emissions from all large appliance or metal furniture surface coating operations, including related cleaning activities, at the facility are equal to or greater than 15 pounds (6.8 kilograms) per day or 2.7 tons (2,455 kilograms) per 12-month rolling period, before consideration of controls.

 (2) The emission limits and other requirements of this section supersede the emission limits and other requirements of § 129.52 (relating to surface coating processes) for large appliance and metal furniture surface coating processes.

 (b) Existing RACT permit. The requirements of this section supersede the requirements of a RACT permit issued to the owner or operator of a source subject to subsection (a)(1) prior to January 1, 2011, under §§ 129.91—129.95 (relating to stationary sources of NOx and VOCs) to control, reduce or minimize VOCs from a large appliance or metal furniture surface coating operation, except to the extent the RACT permit contains more stringent requirements.

 (c) Emission limits. Beginning January 1, 2011, a person subject to this section may not cause or permit the emission into the outdoor atmosphere of VOCs from a large appliance or metal furniture surface coating process, unless one of the following limitations is met:

 (1) The VOC content of each as applied coating is equal to or less than the limit specified in Table I or Table II (relating to emission limits of VOCs for large appliance surface coatings; and emission limits of VOCs for metal furniture surface coatings).

 (i) The VOC content of the as applied coating, expressed in units of weight of VOC per volume of coating solids, shall be calculated as follows:

VOC = (Wo)(Dc)/Vn

Where:

VOC = VOC content in lb VOC/gal of coating solids

Wo = Weight percent of VOC (Wv-Ww-Wex)

Wv = Weight percent of total volatiles (100%-weight per cent solids)

Ww = Weight percent of water

Wex = Weight percent of exempt solvent(s)

Dc = Density of coating, lb/gal, at 25° C

Vn = Volume percent of solids of the as applied coating

 (ii) The VOC content of a dip coating, expressed in units of weight of VOC per volume of coating solids, shall be calculated on a 30-day rolling average basis using the following equation:

SUMi (Woi × Dci × Qi) + SUMJ (WoJ × DdJ × QJ)
VOCA =__________
SUMi (Vni × Qi)

Where:

VOCA = VOC content in lb VOC/gal of coating solids for a dip coating, calculated on a 30-day rolling average basis

Woi = Percent VOC by weight of each as supplied coating (i) added to the dip coating process, expressed as a decimal fraction (that is 55% = 0.55)

Dci = Density of each as supplied coating (i) added to the dip coating process, in pounds per gallon

Qi = Quantity of each as supplied coating (i) added to the dip coating process, in gallons

Vni = Percent solids by volume of each as supplied coating (i) added to the dip coating process, expressed as a decimal fraction

WoJ = Percent VOC by weight of each thinner (J) added to the dip coating process, expressed as a decimal fraction

DdJ = Density of each thinner (J) added to the dip coating process, in pounds per gallon

QJ = Quantity of each thinner (J) added to the dip coating process, in gallons

 (iii) Sampling and testing shall be done in accordance with the procedures and test methods specified in Chapter 139 (relating to sampling and testing).

 (2) The overall weight of VOCs emitted to the atmosphere is reduced through the use of vapor recovery or incineration or another method that is acceptable under § 129.51(a) (relating to general). The overall efficiency of a control system, as determined by the test methods and procedures specified in Chapter 139, may be no less than 90% or may be no less than the equivalent efficiency as calculated by the following equation, whichever is less stringent:

O = (1 - E/V) × 100

Where:

V = The VOC content of the as applied coating, in lb VOC/gal of coating solids.

E = The Table I or Table II limit in lb VOC /gal of coating  solids.

O = The overall required control efficiency.

 (d) Compliance monitoring procedures. The owner or operator of a facility subject to this section shall maintain records sufficient to demonstrate compliance with this section. At a minimum, the owner or operator shall maintain daily records of:

 (1) The following parameters for each coating, thinner, component and cleaning solvent as supplied:

 (i) Name and identification number.

 (ii) Volume used.

 (iii) Mix ratio.

 (iv) Density or specific gravity.

 (v) Weight percent of total volatiles, water, solids and exempt solvents.

 (vi) Volume percent of solids for each Table I or Table II coating used in the surface coating process.

 (2) The VOC content of each coating, thinner, component and cleaning solvent as supplied.

 (3) The VOC content of each as applied coating or cleaning solvent.

 (e) Recordkeeping and reporting requirements. The records required under subsection (d) shall be maintained for 2 years and submitted to the Department on request.

 (f) Coating application methods. A person subject to this section may not cause or permit the emission into the outdoor atmosphere of VOCs from the application of large appliance or metal furniture surface coatings, unless the coatings are applied using one or more of the following coating application methods:

 (1) Electrostatic coating.

 (2) Roller coating.

 (3) Flow coating.

 (4) Dip coating, including electrodeposition.

 (5) High volume-low pressure (HVLP) spray.

 (6) Brush coating.

 (7) Other coating application method, if approved in writing by the Department prior to use.

 (i) The coating application method must be capable of achieving a transfer efficiency equivalent to or better than that achieved by the methods listed in paragraphs (1)—(6).

 (ii) The request for approval must be submitted in writing.

 (g) Exempt coatings and coating operations. The VOC coating content limits in Table I and Table II do not apply to the following types of coatings and coating operations:

 (1) Stencil coatings.

 (2) Safety-indicating coatings.

 (3) Solid-film lubricants.

 (4) Electric-insulating coatings.

 (5) Thermal-conducting coatings.

 (6) Touch-up and repair coatings.

 (7) Coating applications using hand-held aerosol cans.

 (8) A coating used exclusively for determining product quality and commercial acceptance and other small quantity coatings, if the coating meets the following criteria:

 (i) The quantity of coating used does not exceed 50 gallons per year for a single coating and a total of 200 gallons per year for all coatings combined for the facility.

 (ii) The owner or operator of the facility requests, in writing, and the Department approves, in writing, the exemption prior to use of the coating.

 (h) Work practice requirements for coating-related activities. The owner or operator of a large appliance or metal furniture surface coating process subject to this section shall comply with the following work practices for coating-related activities:

 (1) Store all VOC-containing coatings, thinners and coating-related waste materials in closed containers.

 (2) Ensure that mixing and storage containers used for VOC-containing coatings, thinners and coating-related waste materials are kept closed at all times except when depositing or removing these materials.

 (3) Minimize spills of VOC-containing coatings, thinners and coating-related waste materials and clean up spills immediately.

 (4) Convey VOC-containing coatings, thinners and coating-related waste materials from one location to another in closed containers or pipes.

 (i) Work practice requirements for cleaning materials. The owner or operator of a large appliance or metal furniture surface coating process subject to this section shall comply with the following work practices for cleaning materials:

 (1) Store all VOC-containing cleaning materials and used shop towels in closed containers.

 (2) Ensure that mixing and storage containers used for VOC-containing cleaning materials are kept closed at all times except when depositing or removing these materials.

 (3) Minimize spills of VOC-containing cleaning materials and clean up spills immediately.

 (4) Convey VOC-containing cleaning materials from one location to another in closed containers or pipes.

 (5) Minimize VOC emissions from cleaning of storage, mixing and conveying equipment.

Table I

Emission Limits of VOCs for Large Appliance Surface Coatings

Weight of VOC per Volume of Coating Solids,
as Applied

Coating Type
Baked Air Dried
kg/l lb/gal kg/l lb/gal
General, One Component 0.40  3.3 0.40  3.3
General, Multi-Component 0.40  3.3 0.55  4.5
Extreme High Gloss 0.55 4.62 0.55 4.5
Extreme Performance 0.55 4.62 0.55 4.62
Heat Resistant 0.55 4.62 0.55 4.62
Metallic 0.55 4.62 0.55 4.62
Pretreatment 0.55 4.62 0.55 4.62
Solar Absorbent 0.55 4.62 0.55 4.62

Table II

Emission Limits of VOCs for Metal Furniture Surface Coatings

Weight of VOC per Volume of Coating Solids,
as Applied

Coating Type
Baked Air Dried
kg/l lb/gal kg/l lb/gal
General, One Component 0.40 3.3 0.40 3.3
General, Multi-Component 0.40 3.3 0.55 4.5
Extreme High Gloss 0.61 5.06 0.55 4.5
Extreme Performance 0.61 5.06 0.61 5.06
Heat Resistant 0.61 5.06 0.61 5.06
Metallic 0.61 5.06 0.61 5.06
Pretreatment 0.61 5.06 0.61 5.06
Solar Absorbent 0.61 5.06 0.61 5.06
[Pa.B. Doc. No. 10-104. Filed for public inspection January 15, 2010, 9:00 a.m.]