PA Bulletin, Doc. No. 24-1159

NOTICES

DEPARTMENT OF ENVIRONMENTAL PROTECTION

Applications, Actions and Special Notices


APPLICATIONS

[54 Pa.B. 5245]
[Saturday, August 17, 2024]

THE PENNSYLVANIA CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT

APPLICATIONS FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS UNDER THE CLEAN STREAMS LAW AND FEDERAL CLEAN
WATER ACT

 This notice provides information about persons who have applied to the Department of Environmental Protection (DEP) for a new, renewed, or amended NPDES or WQM permit, or a permit waiver for certain stormwater discharges, or have submitted a Notice of Intent (NOI) for coverage under a General Permit. The applications and NOIs concern, but are not limited to, effluent discharges from sewage treatment facilities and industrial facilities to surface waters or groundwater; stormwater discharges associated with industrial activity (industrial stormwater), construction activity (construction stormwater), and municipal separate storm sewer systems (MS4s); the application of pesticides; the operation of Concentrated Animal Feeding Operations (CAFOs); and the construction of sewage, industrial waste, and manure storage, collection and treatment facilities. This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92a and 40 CFR Part 122, implementing The Clean Streams Law (35 P.S. §§ 691.1—691.1001) and the Federal Clean Water Act (33 U.S.C.A. §§ 1251—1376). More information on the types of NPDES and WQM permits that are available can be found on DEP's website (visit www.dep.pa.gov and select Businesses, Water, Bureau of Clean Water, Wastewater Management, and NPDES and WQM Permitting Programs).

Section   Category
I Individual and General WQM Permit Applications/NOIs Received, General NPDES Permit NOIs Received, and All Transfer and Minor Amendment Applications/NOIs Received
II Individual NPDES Permits—New, Renewal, and Major Amendment Applications and Draft Permits for Discharges Relating to Sewage, Industrial Waste, Industrial Stormwater, MS4s, Pesticides and CAFOs
III Individual NPDES Permit Applications for Discharges of Stormwater Associated with Construction Activity

 Section I identifies the following applications and NOIs that have been received by DEP:

 • Individual and General WQM Permit Applications Received—DEP provides a 15-day public comment period for Individual WQM Permit Applications for new and reissued permits. There is no public comment period for General WQM Permit NOIs.

 • General Chapter 92a NPDES Permit NOIs Received—There is no public comment period for General NPDES NOIs received.

 • All Transfer and Minor Amendment Applications/NOIs Received—Transfer and Minor Amendment Applications/NOIs received for Individual and General WQM Permits and Individual and General NPDES Permits, excluding PAG-01 and PAG-02, are identified but do not have public comment periods. DEP provides a 15-day public comment period for Individual WQM Permit Applications for amendments.

 Additional information on these applications and NOIs may be reviewed by generating the ''Applications and NOIs without Comment Periods Report'' or, for Individual WQM Permit Applications, the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice.

 Section II identifies individual NPDES permit applications received and draft permits indicating DEP's tentative determination relating to sewage, industrial waste, industrial stormwater, MS4s, pesticides and CAFOs. A 30-day public comment period applies to these applications and draft permits, except when a site-specific water quality criterion is used to establish effluent limitations, in which case a 45-day public comment period applies. The period for comment may be extended at the discretion of DEP for one additional 15-day period. Additional information, including links to draft permits and fact sheets that explain the basis for DEP's tentative determinations may be reviewed by generating the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice. Notification of 15-day extensions for comment will be provided in the ''Applications Received with Comment Periods Report'' (Comments column).

 Section III identifies individual NPDES permit applications received and draft permits indicating DEP's tentative determination relating to stormwater discharges associated with construction activities. A 30-day public comment period applies to these applications and draft permits. The period for comment may be extended at the discretion of the Department for one additional 15-day period. Additional information may be reviewed by generating the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice.

 Applications, NOIs and draft permits, where applicable, may be reviewed at the DEP office that received the application or NOI. Members of the public are encouraged to use DEP's website to obtain additional information as discussed previously.

 Comments received within the appropriate comment periods for WQM and NPDES permit applications will be retained by DEP and considered in the final determinations regarding the applications. A comment submittal should include the name, address and telephone number of the writer and a concise statement to inform DEP of the exact basis of a comment and the relevant facts upon which it is based.

 DEP office contact information to review applications and NOIs and to submit comments for those applications, when applicable, is as follows:

DEP Southeast Regional Office (SERO)—2 E. Main Street, Norristown, PA 19401-4915. File Review Coordinator: 484-250-5910. Email: RA-EPNPDES_SERO@pa.gov for permits in Sections I & II; RA-EPWW-SERO@pa.gov for permits in Section III.

DEP Northeast Regional Office (NERO)—2 Public Square, Wilkes-Barre, PA 18701-1915. File Review Coordinator: 570-826-5472. Email: RA-EPNPDES_NERO@pa.gov for permits in Sections I & II; RA-EPWW-NERO@pa.gov for permits in Section III.

DEP Southcentral Regional Office (SCRO)—909 Elmerton Avenue, Harrisburg, PA 17110. File Review Coordinator: 717-705-4732. Email: RA-EPNPDES_SCRO@pa.gov for permits in Sections I & II; RA-EPWW-SCRO@pa.gov for permits in Section III.

DEP Northcentral Regional Office (NCRO)—208 W. Third Street, Suite 101, Williamsport, PA 17701. File Review Coordinator: 570-327-3693. Email: RA-EPNPDES_NCRO@pa.gov for permits in Sections I & II; RA-EPWW-NCRO@pa.gov ermits in Section III.

DEP Southwest Regional Office (SWRO)—400 Waterfront Drive, Pittsburgh, PA 15222. File Review Coordinator: 412-442-4286. Email: RA-EPNPDES_SWRO@pa.gov for permits in Sections I & II; RA-EPWW-SWRO@pa.gov for permits in Section III.

DEP Northwest Regional Office (NWRO)—230 Chestnut Street, Meadville, PA 16335. File Review Coordinator: 814-332-6340. Email: RA-EPNPDES_NWRO@pa.gov for permits in Sections I & II; RA-EPWW-NWRO@pa.gov for permits in Section III.

DEP Bureau of Clean Water (BCW)—400 Market Street, Harrisburg, PA 17105. File Review Coordinator: 717-787-5017. Email: RA-EPNPDES_Permits@pa.gov.

DEP Regional Permit Coordination Office (RPCO)—400 Market Street, Harrisburg, PA 17105. File Review Coordinator: 717-772-5987. Email: RA-EPREGIONALPERMIT@pa.gov.

 DEP will also accept requests or petitions for public hearings on applications. The request or petition must indicate the interest of the party filing and the reasons why a hearing is warranted. A hearing will be held if DEP determines that there is a significant public interest. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. DEP will postpone its final determination until after a public hearing is held.

 Individuals in need of accommodations should contact DEP through the Pennsylvania Hamilton Relay Service at (800) 654-5984 (TDD users) or (800) 654-5988 (voice users).


I. Individual and General WQM Permit Applications/NOIs Received, General NPDES Permit NOIs Received, and All Transfer and Minor Amendment Applications/NOIs Received.

Application Number Permit Type Application Type Applicant Name & Address Municipality, County DEP Office
0924808 Joint DEP/PFBC Pesticides Permit New Wigand James R
5541 Carversville Road
Doylestown, PA 18902-1325
Buckingham Township
Bucks County
SERO
1524812 Joint DEP/PFBC Pesticides Permit New Ashlea HOA
7 Ashlea Drive
Glenmoore, PA 19343-1435
Wallace Township
Chester County
SERO
3524804 Joint DEP/PFBC Pesticides Permit New Shorten Cathie
65 Stevens Road
Jefferson Township, PA 18436-3941
Jefferson Township
Lackawanna County
NERO
3624805 Joint DEP/PFBC Pesticides Permit New Fisher Dan
550 Stonehenge Drive
Lititz, PA 17543-9072
Manheim Township
Lancaster County
SCRO
3924803 Joint DEP/PFBC Pesticides Permit New Jaindl Commercial Park Association
6144 Hamilton Boulevard
Allentown, PA 18106
Lower Macungie Township
Lehigh County
NERO
4024809 Joint DEP/PFBC Pesticides Permit New Beech Mountain Lake Association
1 Burke Drive
Drums, PA 18222-1200
Butler Township
Luzerne County
NERO
2824201 Manure Storage and Wastewater Impoundments Individual WQM Permit New Rotz Milton
1015 Heritage Avenue
Shippensburg, PA 17257-9267
Greene Township
Franklin County
SCRO
2824201E Manure Storage and Wastewater Impoundments Individual WQM Permit New Rotz Milton
1015 Heritage Avenue
Shippensburg, PA 17257-9267
Greene Township
Franklin County
SCRO
PA0034185 Minor Sewage Facility
< 0.05 MGD Individual NPDES Permit
Transfer PWF1 High Meadows LLC
4751 Kendor Drive
New Kensington, PA 15068-9506
Allegheny Township
Westmoreland County
SWRO
PA0061921 Minor Sewage Facility
>= 0.05 MGD and
< 1 MGD Individual NPDES Permit
Transfer Brookdale Enterprises LLC
2455 Black Mountain Road
Scotrun, PA 18355
Pocono Township
Monroe County
NERO
1002415 Minor and Non-NPDES Sewage Treatment Facility Individual WQM Permit Transfer Stoneworth APT Group LLC
589 Greason Road
Carlisle, PA 17015-9416
Worth Township
Butler County
NWRO
1500413 Minor and Non-NPDES Sewage Treatment Facility Individual WQM Permit Amendment East Brandywine Township Municipal Authority
Chester County
1214 Horseshoe Pike
Downingtown, PA 19335-1132
East Brandywine Township
Chester County
SERO
4472401 Minor and Non-NPDES Sewage Treatment Facility Individual WQM Permit Amendment McVeytown Borough Authority Mifflin County
P.O. Box 321
McVeytown, PA 17051-0321
McVeytown Borough
Mifflin County
SCRO
6569433 Minor and Non-NPDES Sewage Treatment Facility Individual WQM Permit Transfer PWF1 High Meadows LLC
4751 Kendor Drive
New Kensington, PA 15068-9506
Allegheny Township
Westmoreland County
SWRO
6598407 Minor and Non-NPDES Sewage Treatment Facility Individual WQM Permit Amendment Westmoreland County Municipal Authority
124 Park and Pool Road
New Stanton, PA 15672
East Huntingdon Township
Westmoreland County
SWRO
NOEXNW121 No Exposure Certification Renewal Lord Corp
2455 Robison Road W
Erie, PA 16509-4675
Summit Township
Erie County
NWRO
NOEXNW126 No Exposure Certification Renewal Combined System Inc.
388 Kinsman Road
Jamestown, PA 16134-9540
Greene Township
Mercer County
NWRO
NOEXNW146 No Exposure Certification Transfer Federal Express Corporation
3620 Hacks Cross Road
Memphis, TN 38125-8800
McKean Township
Erie County
NWRO
NOEXNW205 No Exposure Certification Renewal Heatron Inc.
8135 Nathan Circle
Erie, PA 16509-4656
Summit Township
Erie County
NWRO
NOEXSC430 No Exposure Certification New Laborie Medical Technologies
180 International Drive
Portsmouth, NH 03801-6837
Upper Allen Township
Cumberland County
SCRO
NOEXSC431 No Exposure Certification New Voith US Inc.
25 Winship Road
York, PA 17406-8419
Manchester Township
York County
SCRO
PAG033650 PAG-03 NPDES General Permit for Industrial Stormwater Amendment Cargill Inc.
15407 McGinty Road W
Wayzata, MN 55391-2365
Mount Joy Borough
Lancaster County
SCRO
PAG033981 PAG-03 NPDES General Permit for Industrial Stormwater Amendment Airgas USA LLC
P.O. Box 13577
Reading, PA 19612-3577
Muhlenberg Township
Berks County
SCRO
PAG038343 PAG-03 NPDES General Permit for Industrial Stormwater Transfer Federal Express Corporation
3620 Hacks Cross Road
Memphis, TN 38125-8800
Jackson Township
Butler County
NWRO
PAG038522 PAG-03 NPDES General Permit for Industrial Stormwater Transfer Goodfellow Distr Inc.
225 Goodfellow Street
Quebec, QC J5B 1V5
Pittsfield Township
Warren County
NWRO
PAG041109 PAG-04 NPDES General Permit for Small Flow Treatment Facilities Transfer Hernandez Jay
10220 US Highway 322
Conneaut Lake, PA 16316-1813
Sadsbury Township
Crawford County
NWRO
PAG041338 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Sperring Arthur Jr
1776 S Neshannock Road
Hermitage, PA 16148
Hermitage City
Mercer County
NWRO
PAG041365 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Hague Benaiah
3390 Portersville Road
Portersville, PA 16051-3214
Perry Township
Lawrence County
NWRO
PAG041370 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Sander Peter
14615 Stewart Road
Corry, PA 16407-9640
Concord Township
Erie County
NWRO
PAG041371 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New McBroom Michael
163 W Jamestown Road
Jamestown, PA 16134-9513
Greene Township
Mercer County
NWRO
PAG041372 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Sullivan Shannan
323 Rowley Road
Sugar Grove, PA 16350-5718
Sugar Grove Township
Warren County
NWRO
PAG041373 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Agnew Anne
14601 Coleman Road
Meadville, PA 16335-8712
Vernon Township
Crawford County
NWRO
PAG041385 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Yoder Ernest
357 Kinsman Road
Jamestown, PA 16134
Greene Township
Mercer County
NWRO
PAG041394 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Nancy & Richard Miller
292 Donation Road
Greenville, PA 16125-8008
South Shenango Township
Crawford County
NWRO
PAG041395 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Hopkins Pennie
1315 Lanning Hill Road
Sugar Grove, PA 16350-6105
Farmington Township
Warren County
NWRO
PAG041398 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Al Dhumeen Ali
8089 Edinboro Road
Erie, PA 16509-4466
Summit Township
Erie County
NWRO
PAG043995 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Point View Cottage Association
173 Point View Drive
Williamsburg, PA 16693-6940
Catharine Township
Blair County
SCRO
PAG046163 PAG-04 NPDES General Permit for Small Flow Treatment Facilities Transfer Murdock Mirissa & Adam
222 Beaver Hollow Road
Somerset, PA 15501-6737
Somerset Township
Somerset County
SWRO
PAG106233 PAG-10 NPDES General Permit for Hydrostatic Test Water New Equitrans LP
2200 Energy Drive
Canonsburg, PA 15317-1000
Somerset Township
Washington County
SWRO
PAG123767 PAG-12 NPDES General Permit for CAFOs Renewal Brubaker Farms LLC
490 Musser Road
Mount Joy, PA 17552-9044
East Donegal Township
Lancaster County
SCRO
PAG123861 PAG-12 NPDES General Permit for CAFOs Renewal Stoners Hijos Hill Inc.
7678 Oellig Road
Mercersburg, PA 17236-9549
Peters Township
Franklin County
SCRO
PAG123951 PAG-12 NPDES General Permit for CAFOs New McCartney Inc.
17275 Dry Run Road S
Dry Run, PA 17220-9705
Fannett Township
Franklin County
SCRO
6524411 Pump Stations Individual WQM Permit Amendment Westmoreland County Municipal Authority
124 Park and Pool Road
New Stanton, PA 15672
Hempfield Township
Westmoreland County
SWRO
PA0289841 Single Residence STP Individual NPDES Permit Transfer Juergens Mara
153 Cowden Road
New Wilmington, PA 16142-1823
Wilmington Township
Mercer County
NWRO
1024410 Single Residence Sewage Treatment Plant Individual WQM Permit New Kunkle Vicki
317 Bicker Road
Cabot, PA 16023-2505
Winfield Township
Butler County
NWRO
2003415 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer Hernandez Jay
10220 US Highway 322
Conneaut Lake, PA 16316-1813
Sadsbury Township
Crawford County
NWRO
4321411 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer Juergens Mara
153 Cowden Road
New Wilmington, PA 16142-1823
Wilmington Township
Mercer County
NWRO
5698407 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer Murdock Mirissa & Adam
222 Beaver Hollow Road
Somerset, PA 15501-6737
Somerset Township
Somerset County
SWRO

II. Individual NPDES Permits—New, Renewal, and Major Amendment Applications and Draft Permits for Discharges Relating to Sewage, Industrial Waste, Industrial Stormwater, MS4s, Pesticides and CAFOs.

Northwest Regional Office

PA0295833, Sewage, SIC Code 8800, Tiffany Kline, 2983 W Washington Street, Bradford, PA 16701-2427. Facility Name: Tiffany Kline SRSTP. This proposed facility is located at 2069 W Washington Street, Bradford, PA 16701-2565 in Bradford Township, McKean County.

 Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated SRSTP sewage.

 The receiving stream(s), Willow Creek (HQ-CWF), is located in State Water Plan watershed 16-B and is classified for High Quality Waters—Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .0004 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Annual
Average
Maximum IMAX
Flow (GPD) Report
Annl Avg
XXX XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Carbonaceous Biochemical Oxygen Demand (CBOD5) XXX XXX XXX 10.0 XXX 20.0
Total Suspended Solids XXX XXX XXX 10.0 XXX 20.0
Fecal Coliform (No./100 ml) XXX XXX XXX 200 XXX XXX

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 814-332-6078.

 The EPA Waiver is in effect.

Northwest Regional Office

PA0295892, Sewage, SIC Code 8800, Vanessa Risjan, 2660 Old Wattsburg Road, Waterford, PA 16441-9637. Facility Name: Vanessa Risjan SRSTP. This proposed facility is located in Waterford Township, Erie County.

 Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated SRSTP sewage.

 The receiving stream(s), Unnamed Tributary of French Creek (WWF), is located in State Water Plan watershed 16-A and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .0004 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Annual
Average
Maximum IMAX
Flow (GPD) Report
Annl Avg
XXX XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Carbonaceous Biochemical Oxygen Demand (CBOD5) XXX XXX XXX 10.0 XXX 20.0
Total Suspended Solids XXX XXX XXX 10.0 XXX 20.0
Fecal Coliform (No./100 ml) XXX XXX XXX 200 XXX XXX

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 814-332-6078.

 The EPA Waiver is in effect.

Southcentral Regional Office

PA0081655, Industrial, SIC Code 3569, Philadelphia Mixing Solutions Ltd, 1221 E Main Street, Palmyra, PA 17078-9506. Facility Name: Philadelphia Mixing Solutions. This existing facility is located in Palmyra Borough, Lebanon County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial waste.

 The receiving stream(s), Unnamed Tributary to Killinger Creek (TSF, MF) and Killinger Creek (TSF), is located in State Water Plan watershed 7-D and is classified for Trout Stocking and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .5 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
Maximum
IMAX
Flow (MGD) Report Report
Daily Max
XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Total Dissolved Solids XXX XXX XXX XXX Report XXX
Cobalt, Total XXX XXX XXX XXX Report XXX
Sodium, Total XXX XXX XXX XXX Report XXX
Sulfate, Total XXX XXX XXX XXX Report XXX
Chloride XXX XXX XXX XXX Report XXX
Bromide XXX XXX XXX XXX Report XXX

 The proposed effluent limits for Outfall 002 are based on a design flow of 0 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
Maximum
IMAX
Total Suspended Solids XXX XXX XXX XXX Report XXX
Oil and Grease XXX XXX XXX XXX Report XXX
Aluminum, Total XXX XXX XXX XXX Report XXX
Copper, Total XXX XXX XXX XXX Report XXX
Iron, Total XXX XXX XXX XXX Report XXX
Lead, Total XXX XXX XXX XXX Report XXX

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.

 The EPA Waiver is in effect.

Southcentral Regional Office

PA0265934, Concentrated Animal Feeding Operation (CAFO), David S. Morrow (David S. Morrow Farm CAFO), 237 Briar Lane, Loysville, PA 17047-9154.

 David S. Morrow has submitted an application for an Individual NPDES permit for a renewal of an CAFO known as David S. Morrow Farm CAFO, located in Southwest Madison Township, Perry County.

 The CAFO is situated near Cisna Run (HQ-CWF, MF) in Watershed 7-A, which is classified for High Quality—Cold Water and Migratory Fish. The CAFO is designed to maintain an animal population of approximately 657.65 animal equivalent units (AEUs) consisting of 4,600 Swine grow finish, 15 Beef Cows, and 15 Beef Calf. Liquid swine manure is stored onsite in two concrete underbarn storages. A release or discharge to waters of the Commonwealth under normal operating conditions is not expected. Normal operating conditions are defined as conditions below a 100-year, 24-hour storm event.

 The Department has conducted administrative and technical reviews of the application. Based on the preliminary review and application of lawful standards and regulations, the Department has made a tentative determination to issue an NPDES permit for the operation subject to the terms and conditions and monitoring and reporting requirements specified in the permit.

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.

 The Environmental Protection Agency (EPA) permit waiver provision under 40 CFR 123.24(e) does not apply to this NPDES permit.

Southeast Regional Office

PA0057363, Sewage, SIC Code 4952, Penns Park Master Association, 2288 2nd Street Pike, Penns Park, PA 18943. Facility Name: ARCCA Real Estate SFSTP. This existing facility is located in Wrightstown Township, Bucks County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated SFTF sewage.

 The receiving stream(s), Unnamed Tributary to Neshaminy Creek (WWF, MF), is located in State Water Plan watershed 2-F and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.002 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX
Flow (MGD) Report Report
Daily Max
XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Dissolved Oxygen XXX XXX 4.0
Inst Min
XXX XXX XXX
Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.3
Carbonaceous Biochemical Oxygen Demand (CBOD5)
 Nov 1 - Apr 30
XXX XXX XXX 20 XXX 40
 May 1 - Oct 31 XXX XXX XXX 10 XXX 20
Total Suspended Solids XXX XXX XXX 10 XXX 20
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30
XXX XXX XXX 200
Geo Mean
XXX 1,000
 May 1 - Sep 30 XXX XXX XXX 200
Geo Mean
XXX 1,000
Ammonia-Nitrogen
 Nov 1 - Apr 30
XXX XXX XXX 9.0 XXX 18
 May 1 - Oct 31 XXX XXX XXX 3.0 XXX 6
Total Phosphorus XXX XXX XXX Report XXX XXX

 In addition, the permit contains the following major special conditions:

 • Annual Maintenance Report (AMR) submission requirement

 • Permittee shall optimize chlorine dosages used for disinfection to minimize TRC in effluent

 • Proper disposal of collected screenings, slurries, sludges and other solids

 • Effluent is discharged to a location with little or no assimilative capacity or dilution

 • Notification of the designation of responsible operator

 • Seasonal effluent limits for Fecal Coliform based on DRBC water quality regulations

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.

 The EPA Waiver is in effect.

Southeast Regional Office

PA0058041, Sewage, SIC Code 4952, Aqua PA Wastewater Inc., 762 W Lancaster Ave., Bryn Mawr, PA 19010-3402. Facility Name: Possum Hollow Sewer System & STP. This existing facility is located in Limerick Township, Montgomery County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.

 The receiving stream(s), Schuylkill River (WWF, MF), is located in State Water Plan watershed 3-D and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.7 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Weekly
Average
Daily
Minimum
Average Monthly Weekly
Average
IMAX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Dissolved Oxygen XXX XXX 5.0
Inst Min
XXX XXX XXX
Carbonaceous Biochemical Oxygen Demand (CBOD5) 117 175 XXX 20 30 40
Carbonaceous Biochemical Oxygen Demand (CBOD5)
 Raw Sewage Influent
Report XXX XXX Report XXX XXX
Biochemical Oxygen Demand (BOD5)
 Raw Sewage Influent
Report XXX XXX Report XXX XXX
Total Suspended Solids 175 263 XXX 30 45 60
Total Suspended Solids
 Raw Sewage Influent
Report XXX XXX Report XXX XXX
Fecal Coliform (No./100 ml) XXX XXX XXX 200
Geo Mean
XXX 1,000
Ultraviolet light intensity (µw/cm2) XXX XXX Report XXX XXX XXX
Ammonia-Nitrogen 47 XXX XXX 8.0 XXX 16
Total Phosphorus Report XXX XXX Report XXX Report
Total Dissolved Solids XXX XXX XXX 1,000.0
Avg Qrtly
XXX 2,500
E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report
Copper, Total XXX XXX XXX Report
Avg Qrtly
XXX XXX
Zinc, Total XXX XXX XXX Report
Avg Qrtly
XXX XXX

 In addition, the permit contains the following major special conditions:

 I. Other Requirements

 A. No Stormwater

 B. Property Rights

 C. Sludges Disposal

 D. Operator Notification

 E. Development of O&M Plan

 F. DRBC effluent limits

 G. No Acceptance of the Hauled-In Wastes

 H. Fecal Coliform

 II. Solids Management

 III. PCB Monitoring

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.

 The EPA Waiver is in effect.

Southwest Regional Office

PA0027651, Sewage, SIC Code 4952, West Newton Borough, 112 S Water Street, West Newton, PA 15089-1364. Facility Name: West Newton Borough. This existing facility is located in West Newton Borough, Westmoreland County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.

 The receiving stream(s), Youghiogheny River (WWF) and Unnamed Tributary to Youghiogheny River (WWF), are located in State Water Plan watershed 19-D and are classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.75 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Weekly
Average
Minimum Average Monthly Weekly
Average
IMAX
Flow (MGD) Report Report
Daily Max
XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.6
Carbonaceous Biochemical Oxygen Demand (CBOD5) 156 238 XXX 25.0 38.0 50
Biochemical Oxygen Demand (BOD5)
 Raw Sewage Influent
Report Report
Daily Max
XXX Report Report
Daily Max
XXX
Total Suspended Solids 188 281 XXX 30.0 45.0 60
Total Suspended Solids
 Raw Sewage Influent
Report Report
Daily Max
XXX Report Report
Daily Max
XXX
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30
XXX XXX XXX 2,000
Geo Mean
XXX 10,000
 May 1 - Sep 30 XXX XXX XXX 200
Geo Mean
XXX 1,000
Ammonia-Nitrogen XXX XXX XXX 25.0 XXX 50

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.75 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Weekly
Average
Minimum Average Monthly Weekly
Average
IMAX
E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report
Total Nitrogen XXX XXX XXX XXX Report
Daily Max
XXX
Total Phosphorus XXX XXX XXX XXX Report
Daily Max
XXX

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA Waiver is not in effect.

Southwest Regional Office

PA0030929, Sewage, SIC Code 8063, PA Department of Human Services, 2525 N. 7th Street, CoPA Hub, Suite 150, Harrisburg, PA 17110-2511. Facility Name: Torrance St Hospital STP. This existing facility is located in Derry Township, Westmoreland County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.

 The receiving stream, Unnamed Tributary to McGee Run (CWF), is located in State Water Plan watershed 18-D and is classified for Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .8 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Average Monthly Weekly
Average
Maximum IMAX
E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report

 The proposed effluent limits for Outfall 001 are based on a design flow of .8 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Average Monthly Weekly
Average
Maximum IMAX
Flow (MGD) 0.8 XXX XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Dissolved Oxygen XXX XXX 6.0
Inst Min
XXX XXX XXX
Total Residual Chlorine (TRC) XXX XXX 0.03 XXX XXX 0.09
Carbonaceous Biochemical Oxygen Demand (CBOD5) XXX XXX 25.0 40.0 XXX 50.0
Total Suspended Solids XXX XXX 30.0 45.0 XXX 60.0
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30
XXX XXX XXX 2,000
Geo Mean
XXX 10,000
 May 1 - Sep 30 XXX XXX XXX 200
Geo Mean
XXX 1,000
Ammonia-Nitrogen
 Nov 1 - Apr 30
XXX XXX 3.5 XXX XXX 7.0
 May 1 - Oct 31 XXX XXX 2.0 XXX XXX 4.0

 The proposed effluent limits for Outfall 001 are based on a design flow of .8 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Average Monthly Weekly
Average
Maximum IMAX
Total Nitrogen XXX XXX XXX Report
Daily Max
XXX XXX
Total Phosphorus XXX XXX XXX Report
Daily Max
XXX XXX
Aluminum, Total XXX XXX XXX Report
Daily Max
XXX XXX
Iron, Total XXX XXX XXX Report
Daily Max
XXX XXX
Manganese, Total XXX XXX XXX Report
Daily Max
XXX XXX
Bromide XXX XXX XXX Report
Daily Max
XXX XXX

 In addition, the permit contains the following major special conditions:

 A. No Stormwater

 B. Acquire Necessary Property Rights

 C. Proper Sludge Disposal

 D. Abandon STP When Municipal Sewers Available

 E. Chlorine Optimization

 F. Operator Notification

 G. Solids Management

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA Waiver is in effect.

Southwest Regional Office

PA0038181, Sewage, SIC Code 4952, Municipal Authority of Westmoreland County, 124 Park and Pool Road, New Stanton, PA 15672. Facility Name: New Stanton STP. This existing facility is located in Hempfield Township, Westmoreland County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.

 The receiving stream(s), Sewickley Creek (WWF), is located in State Water Plan watershed 19-D and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 7.2 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Weekly
Average
Daily
Minimum
Average Monthly Daily
Maximum
IMAX
Total Nitrogen XXX XXX XXX XXX Report XXX
Total Phosphorus XXX XXX XXX XXX Report XXX
Aluminum, Total XXX XXX XXX XXX Report XXX
Antimony, Total XXX XXX XXX XXX Report XXX
Arsenic, Total XXX XXX XXX XXX Report XXX
Boron, Total XXX XXX XXX XXX Report XXX
Iron, Dissolved XXX XXX XXX XXX Report XXX
Iron, Total XXX XXX XXX XXX Report XXX
Manganese, Total XXX XXX XXX XXX Report XXX
Mercury, Total XXX XXX XXX XXX Report XXX
Zinc, Total XXX XXX XXX XXX Report XXX

 The proposed effluent limits for Outfall 001 are based on a design flow of 7.2 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Weekly
Average
Daily
Minimum
Average Monthly Daily
Maximum
IMAX
Flow (MGD) Report Report
Daily Max
XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0 XXX 9.0 XXX
Dissolved Oxygen XXX XXX 5.0 XXX XXX XXX
Total Residual Chlorine (TRC) XXX XXX XXX 0.06 XXX 0.19
Carbonaceous Biochemical Oxygen Demand (CBOD5) 1,500.0 2,400.0 XXX 25.0 40.0
Wkly Avg
50
Biochemical Oxygen Demand (BOD5)
 Raw Sewage Influent
Report Report
Daily Max
XXX Report XXX XXX
Total Suspended Solids 1,800.0 2,700.0 XXX 30.0 45.0
Wkly Avg
60
Total Suspended Solids
 Raw Sewage Influent
Report Report
Daily Max
XXX Report XXX XXX
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30
XXX XXX XXX 2,000
Geo Mean
XXX 10,000
 May 1 - Sep 30 XXX XXX XXX 200
Geo Mean
XXX 1,000
E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report
Ultraviolet light transmittance (%) XXX XXX Report XXX XXX XXX
Ammonia-Nitrogen
 Nov 1 - Apr 30
510.0 XXX XXX 8.5 XXX 17.0
 May 1 - Oct 31 210.0 XXX XXX 3.5 XXX 7.0
Copper, Total XXX XXX XXX 0.026 0.04 XXX
Cyanide, Free XXX XXX XXX Report Report XXX

 The proposed effluent limits for Outfall 001 are based on a design flow of 7.2 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Weekly
Average
Daily
Minimum
Average Monthly Daily
Maximum
IMAX
PFOA (ug/L) XXX XXX XXX XXX Report XXX
PFOS (ug/L) XXX XXX XXX XXX Report XXX
PFBS (ug/L) XXX XXX XXX XXX Report XXX
HFPO-DA (ug/L) XXX XXX XXX XXX Report XXX

 In addition, the permit contains the following major special conditions:

 • Optimization of chlorine dosage

 • Notification of designation of responsible operator

 • Development of an O&M plan

 • Hauled-in waste restriction

 • POTW Pretreatment program implementation

 • Solids management for non-lagoon system

 • WETT without limits

 • Stormwater requirements

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA Waiver is not in effect.

Southwest Regional Office

PA0092487, Sewage, SIC Code 4952, Nino Barsotti, 546 Three Mile Hill Road, Mount Pleasant, PA 15666-8874. Facility Name: Ninos Restaurant STP. This existing facility is located in Bullskin Township, Fayette County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.

 The receiving stream, Unnamed Tributary to Jacobs Creek (CWF), is located in State Water Plan watershed 19-D and is classified for Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .007 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX
E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report
Total Nitrogen XXX XXX XXX XXX Report
Daily Max
XXX
Total Phosphorus XXX XXX XXX XXX Report
Daily Max
XXX

 The proposed effluent limits for Outfall 001 are based on a design flow of .007 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX
Flow (MGD) 0.007 XXX XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Daily Min
XXX 9.0
Daily Max
XXX
Dissolved Oxygen XXX XXX 4.0
Daily Min
XXX XXX XXX
Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.6
Carbonaceous Biochemical Oxygen Demand (CBOD5) XXX XXX XXX 25 XXX 50
Total Suspended Solids XXX XXX XXX 30 XXX 60
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30
XXX XXX XXX 2,000
Geo Mean
XXX 10,000
 May 1 - Sep 30 XXX XXX XXX 200
Geo Mean
XXX 1,000
Ammonia-Nitrogen
 Nov 1 - Apr 30
XXX XXX XXX 20 XXX 40
 May 1 - Oct 31 XXX XXX XXX 10 XXX 20

 In addition, the permit contains the following major special conditions:

 A. No Stormwater

 B. Acquire Necessary Property Rights

 C. Proper Sludge Disposal

 D. Phase Out When Municipal Sewers Available

 E. Chlorine Optimization

 F. Operator Notification

 G. Solids Management

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA Waiver is in effect.

Southwest Regional Office

PA0096628, Sewage, SIC Code 4952, Hamill Manufacturing Co. Inc., 500 Pleasant Valley Road, Trafford, PA 15085-2701. Facility Name: Hamill Manufacturing STP. This existing facility is located in Penn Township, Westmoreland County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated SFTF sewage.

 The receiving stream, Lyons Run (TSF), is located in State Water Plan watershed 19-A and is classified for Trout Stocking, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .00196 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX
Flow (MGD) Report XXX XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.6
Carbonaceous Biochemical Oxygen Demand (CBOD5) XXX XXX XXX 25 XXX 50
Total Suspended Solids XXX XXX XXX 30 XXX 60
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30
XXX XXX XXX 2,000
Geo Mean
XXX 10,000
 May 1 - Sep 30 XXX XXX XXX 200
Geo Mean
XXX 1,000

 In addition, the permit contains the following major special conditions:

 A. AMR to DEP

 B. DMR to DEP

 C. Septage and Scum Measurement

 D. Septic Tank Pumping

 E. Chlorine Minimization

 F. No Stormwater Condition

 G. Acquire Necessary Property Rights

 H. Proper Sludge Disposal

 I. Phase Out When Municipal Sewers Available

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA Waiver is in effect.

Southwest Regional Office

PA0216089, Sewage, SIC Code 4952, Municipal Authority of Westmoreland County, 124 Park and Pool Road, New Stanton, PA 15672. Facility Name: I-70 Industrial Park STP. This existing facility is located in South Huntingdon Township, Westmoreland County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.

 The receiving stream(s), Youghiogheny River (WWF), is located in State Water Plan watershed 19-D and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.05 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Instantaneous
Minimum
Average Monthly Maximum IMAX
Flow (MGD) Report Report
Daily Max
XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0 XXX XXX 9.0
Dissolved Oxygen XXX XXX 4.0 XXX XXX XXX
Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.6
Carbonaceous Biochemical Oxygen Demand (CBOD5) 10.0 XXX XXX 25.0 XXX 50.0
Biochemical Oxygen Demand (BOD5)
 Raw Sewage Influent
Report XXX XXX Report XXX Report
Total Suspended Solids
 Raw Sewage Influent
Report XXX XXX Report XXX Report
Total Suspended Solids 12.0 XXX XXX 30.0 XXX 60.0
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30
XXX XXX XXX 2,000
Geo Mean
XXX 10,000
 May 1 - Sep 30 XXX XXX XXX 200
Geo Mean
XXX 1,000
Ultraviolet light transmittance (%) XXX XXX Report XXX XXX XXX
Ammonia-Nitrogen Report XXX XXX Report XXX Report

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.05 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Instantaneous
Minimum
Average Monthly Maximum IMAX
E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report
Total Nitrogen XXX XXX XXX XXX Report
Daily Max
XXX
Total Phosphorus XXX XXX XXX XXX Report
Daily Max
XXX

 In addition, the permit contains the following major special conditions:

 • Part C.II—POTW Pretreatment Program Implementation

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA Waiver is not in effect.

Southwest Regional Office

PAI136103, MS4, Edgeworth Borough, 301 Beaver Road, Edgeworth, PA 15143-1001.

 The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Edgeworth Borough, Allegheny County. The receiving stream(s), Unnamed Tributary to Ohio River (WWF) and Little Sewickley Creek (HQ-TSF), is located in State Water Plan watershed 20-G and is classified for High Quality Waters—Trout Stocking and Warm Water Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.

 The applicant has submitted the following plan(s) with the application to reduce pollutant loads to impaired waters:

 • A Pollutant Reduction Plan (PRP)

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA waiver is in effect.

Southwest Regional Office

PAI136113, MS4, Leetsdale Borough, 373 Beaver Street, Leetsdale, PA 15056.

 The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Leetsdale Borough, Allegheny County. The receiving stream(s), Big Sewickley Creek (TSF), Little Sewickley Creek (HQ-TSF), and Ohio River (WWF), are located in State Water Plan watershed 20-G and are classified for Trout Stocking, High Quality Waters—Trout Stocking, and Warm Water Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.

Southwest Regional Office

PAI136140, MS4, Conemaugh Township, Somerset County, 1120 Tire Hill Road, Johnstown, PA 15905-7707.

 The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Conemaugh Township, Somerset County. The receiving streams, Mill Creek (HQ-CWF), Bens Creek (CWF), Unnamed Tributary to Bens Creek (CWF), and Unnamed Tributaries to Stonycreek River (CWF), are located in State Water Plan watershed 18-E and are classified for Cold Water Fishes and High Quality Waters—Cold Water Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.

Southwest Regional Office

PA0255441, Storm Water, SIC Code 4953, Duquesne Light Co., 2825 New Beaver Avenue # N6-Tng, Pittsburgh, PA 15233-1003. Facility Name: Kissick Landfill. This existing facility is located in Indiana Township, Allegheny County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial stormwater.

 The receiving stream(s), Unnamed Tributary to Little Deer Creek (TSF), is located in State Water Plan watershed 18-A and is classified for Trout Stocking, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.0 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
Maximum
IMAX
pH (S.U.) XXX XXX XXX XXX Report XXX
Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX
Total Suspended Solids XXX XXX XXX XXX Report XXX
Total Nitrogen XXX XXX XXX XXX Report XXX
Total Phosphorus XXX XXX XXX XXX Report XXX
Iron, Total XXX XXX XXX XXX Report XXX

 The proposed effluent limits for Outfall 002 are based on a design flow of 0.0 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
Maximum
IMAX
pH (S.U.) XXX XXX XXX XXX Report XXX
Chemical Oxygen Demand (COD) XXX XXX XXX XXX Report XXX
Total Suspended Solids XXX XXX XXX XXX Report XXX
Total Nitrogen XXX XXX XXX XXX Report XXX
Total Phosphorus XXX XXX XXX XXX Report XXX
Iron, Total XXX XXX XXX XXX Report XXX

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.

 The EPA Waiver is in effect.


III. Individual NPDES Permit Applications for Discharges of Stormwater Associated with Construction Activity.

Southeast Regional Office

 Applicant: Alan Mancill

 Applicant Address: P.O. Box 243, Wallingford, PA 19086

 Application Number: PAD230083

 Application Type: New

 Municipality/County: Edgmont Township, Delaware County

 Project Site Name: Alan Mancill

 Total Earth Disturbance Area (acres): 3.7 acres

 Surface Waters Receiving Stormwater Discharges: Rocky Run (HQ-TSF, MF)

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: Subdivision of the property into 3 lots and the construction of 3 single family dwellings. Stormwater management to be provided within a series of underground infiltration beds.

 Special Conditions: N/A

 You may review the permit application file by contacting DEP's File Review Coordinator at 484-250-5910.

Northcentral Regional Office

 Applicant: UGI Utilities, Inc.

 Applicant Address: 1 UGI Drive, Denver, PA 17517

 Application Number: PAD600017

 Application Type: New

 Municipality/County: Union Township, Union County

 Project Site Name: Hymil Section 2 Union County

 Total Earth Disturbance Area (acres): 11.70 acres

 Surface Waters Receiving Stormwater Discharges: Windfield Creek

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: Install approx. 20,566 LF of 8" HDPE and 2,100 LF of 2" HDPE gas mains via direct bury to replace sections of wrought iron, coated steel, HDPE, and Aldyl A gas mains. The proposed gas main will run along Trutt Road from its intersection with County Line Road to intersection with Felmey Road, continue west to address 1446 Felmey Road. An additional proposed main will run along Amish Road from its intersection with Felmey Road to intersection with State Route 304, continue west to its intersection with Supplee Mill Road, continue north to its intersection with Fruit Farm Road, and continue west to address 35 Fruit Farm Road.

 Special Conditions: N/A

 You may review the permit application file by contacting DEP's File Review Coordinator at 570-327-3693.

Northeast Regional Office

 Applicant: Yext Enterprises, LLC, c/o Walter Yext

 Applicant Address: 3893 Tank Farm Road, Emmaus, PA 18049-1036

 Application Number: PAD390303

 Application Type: New

 Municipality/County: Upper Milford Township, Lehigh County

 Project Site Name: 4885 Raymond Court

 Total Earth Disturbance Area (acres): 1.61 acres

 Surface Waters Receiving Stormwater Discharges: UNT to Little Lehigh Creek (HQ-CWF, MF)

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: Construction of a storage unit building with parking.

 Special Conditions: N/A—No site-specific special conditions proposed.

 You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.

Northeast Regional Office

 Applicant: Triple Net Investments CI, LLC, c/o Joe Petrucci

 Applicant Address: 171 Route 173, Suite 201, Asbury, NJ 08802

 Application Number: PAD390301

 Application Type: New

 Municipality/County: South Whitehall Township, Lehigh County

 Project Site Name: 1429 Eck Road Outdoor Storage

 Total Earth Disturbance Area (acres): 4.99 acres

 Surface Waters Receiving Stormwater Discharges: UNT to Little Lehigh Creek (HQ-CWF, MF)

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: Construct an approximately 113,000 sq. ft. outdoor storage parking lot. Site improvements include internal driveways, parking areas, guard shack, utilities including public water and sanitary sewer, stormwater conveyance and management BMPs, and widening of Eck Road.

 Special Conditions: N/A—No site-specific special conditions proposed.

 You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.

Northeast Regional Office

 Applicant: Victaulic Company

 Applicant Address: 4901 Kesslersville Road, Easton, PA 18040

 Application Number: PAD480108

 Application Type: Renewal

 Municipality/County: Forks Township, Northampton County

 Project Site Name: Victaulic Customer Experience Center

 Total Earth Disturbance Area (acres): 4.66 acres

 Surface Waters Receiving Stormwater Discharges: Bushkill Creek (HQ-CWF, MF)

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: Phase I involves the expansion of the existing Customer Experience Center to replace an existing parking lot along with the associated stormwater, landscaping, and utility improvements. Phase II involves expanding the parking lot to accommodate the expanded Customer Experience Center and include the associated stormwater, landscaping, and lighting.

 Special Conditions: N/A—No site-specific special conditions proposed.

 You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.

Northcentral Regional Office

 Applicant: BDC Holdings Inc.

 Applicant Address: 222 Bloomingdale Road, White Plains, NY 10605

 Application Number: PAD140111

 Application Type: New

 Municipality/County: Ferguson Township, Centre County

 Project Site Name: Proposed Stack-N-Stor

 Total Earth Disturbance Area (acres): 2.96 acres

 Surface Waters Receiving Stormwater Discharges: Slab Cabin Run (HQ-CWF, MF)

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: The project proposes to construct an 84,608 square-feet self-storage facility with associated drives, parking areas, sidewalks, utilities, and drainage improvements.

 Special Conditions: N. Off-site Discharges There will be off-site discharges (e.g., discharges to a non-surface water such as a swale, ditch, or ground surface via level spreader, that will flow through a property or properties not owned by the applicant prior to reaching a surface water), the applicant is expected to secure an easement (e.g., common law or express easement) providing legal authority for the off-site discharge, unless waived by the property owner, and to provide for adequate BMPs to prevent accelerated erosion on off-site property. Stormwater management to prevent accelerated erosion is also required for discharges to non-surface waters on property owned by the applicant. Submission of an easement for off-site discharges is not required as part of the application package. An Individual NPDES Permit does not grant property rights.

 You may review the permit application file by contacting DEP's File Review Coordinator at 570-327-3693.

Southcentral Regional Office

 Applicant: PDC Northeast LPIV, LLC

 Applicant Address: 2442 Dupont Drive, Irvine, CA 92612-1523

 Application Number: PAD060113

 Application Type: New

 Municipality/County: New Morgan Borough, Berks County

 Project Site Name: Southern Berks Industrial Park

 Total Earth Disturbance Area (acres): 105 acres

 Surface Waters Receiving Stormwater Discharges: Grace Mine Tailings Reservoir via wetlands (other) and the Conestoga River (CWF, MF) via wetlands (other)

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: First phase of a multi-phase, large scale industrial park project. The first phase of the project consists of constructing an 890,000 square foot warehouse (Flying Eagle) as well as associated internal roads, parking and loading areas, utilities and stormwater management facilities.

 Special Conditions: 1) Removal of trees within the project area may have the potential of effecting endangered Indiana bats. Tree cutting activities shall be done only from November 16 to March 31. 2) Wetland Monitoring.

 You may review the permit application file by contacting DEP's File Review Coordinator at 717-705-4802.

Southcentral Regional Office

 Applicant: Orthaus Road LLC

 Applicant Address: 1470 Hendricks Road, Pennsburg, PA 18073

 Application Number: PAD060039 A-2

 Application Type: Major Amendment

 Municipality/County: Hereford Township, Berks County

 Project Site Name: Memo Farm Subdivision

 Total Earth Disturbance Area (acres): 5.74 acres

 Surface Waters Receiving Stormwater Discharges: Perkiomen Creek (HQ-CWF, MF)

 Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.

 Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.

 Project Description: Construction and land development for three residential lots.

 Special Conditions: N/A