NOTICES
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Applications, Actions and Special Notices
APPLICATIONS
[54 Pa.B. 5373]
[Saturday, August 24, 2024]
THE PENNSYLVANIA CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT
APPLICATIONS FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS UNDER THE CLEAN STREAMS LAW AND FEDERAL CLEAN
WATER ACTThis notice provides information about persons who have applied to the Department of Environmental Protection (DEP) for a new, renewed, or amended NPDES or WQM permit, or a permit waiver for certain stormwater discharges, or have submitted a Notice of Intent (NOI) for coverage under a General Permit. The applications and NOIs concern, but are not limited to, effluent discharges from sewage treatment facilities and industrial facilities to surface waters or groundwater; stormwater discharges associated with industrial activity (industrial stormwater), construction activity (construction stormwater), and municipal separate storm sewer systems (MS4s); the application of pesticides; the operation of Concentrated Animal Feeding Operations (CAFOs); and the construction of sewage, industrial waste, and manure storage, collection and treatment facilities. This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92a and 40 CFR Part 122, implementing The Clean Streams Law (35 P.S. §§ 691.1—691.1001) and the Federal Clean Water Act (33 U.S.C.A. §§ 1251—1376). More information on the types of NPDES and WQM permits that are available can be found on DEP's website (visit www.dep.pa.gov and select Businesses, Water, Bureau of Clean Water, Wastewater Management, and NPDES and WQM Permitting Programs).
Section Category I Individual and General WQM Permit Applications/NOIs Received, General NPDES Permit NOIs Received, and All Transfer and Minor Amendment Applications/NOIs Received II Individual NPDES Permits—New, Renewal, and Major Amendment Applications and Draft Permits for Discharges Relating to Sewage, Industrial Waste, Industrial Stormwater, MS4s, Pesticides and CAFOs III Individual NPDES Permit Applications for Discharges of Stormwater Associated with Construction Activity Section I identifies the following applications and NOIs that have been received by DEP:
• Individual and General WQM Permit Applications Received—DEP provides a 15-day public comment period for Individual WQM Permit Applications for new and reissued permits. There is no public comment period for General WQM Permit NOIs.
• General Chapter 92a NPDES Permit NOIs Received—There is no public comment period for General NPDES NOIs received.
• All Transfer and Minor Amendment Applications/NOIs Received—Transfer and Minor Amendment Applications/NOIs received for Individual and General WQM Permits and Individual and General NPDES Permits, excluding PAG-01 and PAG-02, are identified but do not have public comment periods. DEP provides a 15-day public comment period for Individual WQM Permit Applications for amendments.
Additional information on these applications and NOIs may be reviewed by generating the ''Applications and NOIs without Comment Periods Report'' or, for Individual WQM Permit Applications, the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice.
Section II identifies individual NPDES permit applications received and draft permits indicating DEP's tentative determination relating to sewage, industrial waste, industrial stormwater, MS4s, pesticides and CAFOs. A 30-day public comment period applies to these applications and draft permits, except when a site-specific water quality criterion is used to establish effluent limitations, in which case a 45-day public comment period applies. The period for comment may be extended at the discretion of DEP for one additional 15-day period. Additional information, including links to draft permits and fact sheets that explain the basis for DEP's tentative determinations may be reviewed by generating the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice. Notification of 15-day extensions for comment will be provided in the ''Applications Received with Comment Periods Report'' (Comments column).
Section III identifies individual NPDES permit applications received and draft permits indicating DEP's tentative determination relating to stormwater discharges associated with construction activities. A 30-day public comment period applies to these applications and draft permits. The period for comment may be extended at the discretion of the Department for one additional 15-day period. Additional information may be reviewed by generating the ''Applications Received with Comment Periods Report'' on DEP's website at www.dep.pa.gov/CWPublicNotice.
Applications, NOIs and draft permits, where applicable, may be reviewed at the DEP office that received the application or NOI. Members of the public are encouraged to use DEP's website to obtain additional information as discussed previously.
Comments received within the appropriate comment periods for WQM and NPDES permit applications will be retained by DEP and considered in the final determinations regarding the applications. A comment submittal should include the name, address and telephone number of the writer and a concise statement to inform DEP of the exact basis of a comment and the relevant facts upon which it is based.
DEP office contact information to review applications and NOIs and to submit comments for those applications, when applicable, is as follows:
DEP Southeast Regional Office (SERO)—2 E. Main Street, Norristown, PA 19401-4915. File Review Coordinator: 484-250-5910. Email: RA-EPNPDES_SERO@pa.gov for permits in Sections I & II; RA-EPWW-SERO@pa.gov for permits in Section III.
DEP Northeast Regional Office (NERO)—2 Public Square, Wilkes-Barre, PA 18701-1915. File Review Coordinator: 570-826-5472. Email: RA-EPNPDES_NERO@pa.gov for permits in Sections I & II; RA-EPWW-NERO@pa.gov for permits in Section III.
DEP Southcentral Regional Office (SCRO)—909 Elmerton Avenue, Harrisburg, PA 17110. File Review Coordinator: 717-705-4732. Email: RA-EPNPDES_SCRO@pa.gov for permits in Sections I & II; RA-EPWW-SCRO@pa.gov for permits in Section III.
DEP Northcentral Regional Office (NCRO)—208 W. Third Street, Suite 101, Williamsport, PA 17701. File Review Coordinator: 570-327-3693. Email: RA-EPNPDES_NCRO@pa.gov for permits in Sections I & II; RA-EPWW-NCRO@pa.gov for permits in Section III.
DEP Southwest Regional Office (SWRO)—400 Waterfront Drive, Pittsburgh, PA 15222. File Review Coordinator: 412-442-4286. Email: RA-EPNPDES_SWRO@pa.gov for permits in Sections I & II; RA-EPWW-SWRO@pa.gov for permits in Section III.
DEP Northwest Regional Office (NWRO)—230 Chestnut Street, Meadville, PA 16335. File Review Coordinator: 814-332-6340. Email: RA-EPNPDES_NWRO@pa.gov for permits in Sections I & II; RA-EPWW-NWRO@pa.gov for permits in Section III.
DEP Bureau of Clean Water (BCW)—400 Market Street, Harrisburg, PA 17105. File Review Coordinator: 717-787-5017. Email: RA-EPNPDES_Permits@pa.gov.
DEP Regional Permit Coordination Office (RPCO)—400 Market Street, Harrisburg, PA 17105. File Review Coordinator: 717-772-5987. Email: RA-EPREGIONALPERMIT@pa.gov.
DEP will also accept requests or petitions for public hearings on applications. The request or petition must indicate the interest of the party filing and the reasons why a hearing is warranted. A hearing will be held if DEP determines that there is a significant public interest. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. DEP will postpone its final determination until after a public hearing is held.
Individuals in need of accommodations should contact DEP through the Pennsylvania Hamilton Relay Service at (800) 654-5984 (TDD users) or (800) 654-5988 (voice users).
I. Individual and General WQM Permit Applications/NOIs Received, General NPDES Permit NOIs Received, and All Transfer and Minor Amendment Applications/NOIs Received.
Application Number Permit Type Application Type Applicant Name & Address Municipality, County DEP Office PAD650074 Chapter 102 Individual NPDES Permit Transfer Novick Christian
447 Narigon Run Road
Claysville, PA 15323-1230Independence Township
Washington CountySWRO 1124800 Joint DEP/PFBC Pesticides Permit New CPV Fairview Energy Center
2862 William Penn Avenue
Johnstown, PA 15909-3628Jackson Township
Cambria CountySWRO 0609404 Major Sewage Treatment Facility Individual WQM Permit Amendment Spring Township
Berks County
2850 Windmill Road
Sinking Spring, PA 19608-1668Spring Township
Berks CountySCRO 4292401 Major Sewage Treatment Facility Individual WQM Permit Amendment PA American Water Co.
425 Waterworks Road
Clarion, PA 16214-2343Kane Borough
McKean CountyNWRO 3602204 Manure Storage and Wastewater Impoundments Individual WQM Permit Amendment Pennmar Dairy LLC
176 Puseyville Road
Quarryville, PA 17566-9693Fulton Township
Lancaster CountySCRO PA0040860 Minor Industrial Waste Facility with ELG Individual NPDES Permit Amendment, Minor Delaware County SWA
610 E Baltimore Pike
Media, PA 19063-1750Earl Township
Berks CountySCRO 5508402 Minor and Non-NPDES Sewage Treatment Facility Individual WQM Permit Amendment Perry Township Municipal Authority
Snyder County
P.O. Box 27
Mt Pleasant, PA 17853-0027Perry Township
Snyder CountyNCRO NOEXNE020 No Exposure Certification Renewal Liberty Soils LLC
661 Main Street
Niagara Falls, NY 14301Reilly Township
Schuylkill CountyNERO NOEXNE063 No Exposure Certification New Newly Weds Foods
23 S Commerce Way
Bethlehem, PA 18017-8916Bethlehem Township
Northampton CountyNERO NOEXNE064 No Exposure Certification New Newly Weds Foods
177 Mikron Road
Bethlehem, PA 18020-9353Bethlehem Township
Northampton CountyNERO NOEXSE016 No Exposure Certification Renewal Flowserve Corp
19 Creek Parkway
Boothwyn, PA 19061-3148Upper Chichester Township
Delaware CountySERO PAG038614 PAG-03 NPDES General Permit for Industrial Stormwater New Miller Welding & Mach Co.
P.O. Box G
Brookville, PA 15825-0607Pine Creek Township
Jefferson CountyNWRO PAG304091 PAG-03 NPDES General Permit for Industrial Stormwater Renewal Jim Sacco Auto Wrecker
2469 Cooks Mill Road
Hyndman, PA 15545-7964Londonderry Township
Bedford CountySCRO PAG041391 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Pringle Austin
5350 Stevenson Hill Road
Falls Creek, PA 15840-2508Washington Township
Jefferson CountyNWRO PAG041392 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Englert Pamela
2622 Neilltown Road
Pleasantville, PA 16341-5020Harmony Township
Forest CountyNWRO PAG041393 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Homa Casey
99 Fredonia Hadley Road
Fredonia, PA 16124Fairview Township
Mercer CountyNWRO PAG041399 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Schmelzer Deborah
151 Etna Road
Slippery Rock, PA 16057Slippery Rock Township
Butler CountyNWRO PAG041400 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Harrison Michaela
852b Patterson School Road
Grove City, PA 16127Worth Township
Mercer CountyNWRO PAG041401 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New James & Tabatha Volle
3598 Fallen Drive
Jamestown, PA 16134-3412West Shenango Township
Crawford CountyNWRO PAG041402 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Candace & Frank Reina
151 Sunville Road
Franklin, PA 16323-7341Oakland Township
Venango CountyNWRO PAG041403 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Devine Autumn
14 Millburn Road
Mercer, PA 16137-3710Springfield Township
Mercer CountyNWRO PAG041405 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New March Garland
10611 Pine Road
Conneaut Lake, PA 16316-6729Vernon Township
Crawford CountyNWRO PAG041406 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Heilman June
28 Rutledge Road
Greenville, PA 16125-8702South Pymatuning Township
Mercer CountyNWRO PAG041407 PAG-04 NPDES General Permit for Small Flow Treatment Facilities New Amber & Jason Digiacomo
15304 Hall Road
Meadville, PA 16335-7848Hayfield Township
Crawford CountyNWRO PAG045063 PAG-04 NPDES General Permit for Small Flow Treatment Facilities Transfer Donald A & Lisa M Ammerman
1076 Homan Hill Road
Towanda, PA 18848-9519Sheshequin Township
Bradford CountyNCRO PAG048320 PAG-04 NPDES General Permit for Small Flow Treatment Facilities Transfer Brundage Kathleen
1725 Center Road
Columbus, PA 16405-2129Columbus Township
Warren CountyNWRO PAG048434 PAG-04 NPDES General Permit for Small Flow Treatment Facilities Transfer Cassandra & Steven Wales
9451 Donation Road
Waterford, PA 16441-4233Summit Township
Erie CountyNWRO PAG048521 PAG-04 NPDES General Permit for Small Flow Treatment Facilities Transfer James & Nellie Jane Sauer
4930 Sandy Lake Greenville Road
Sandy Lake, PA 16145-2036Sandy Creek Township
Mercer CountyNWRO PAG123624 PAG-12 NPDES General Permit for CAFOs Renewal Ebling Joann L & Ebling Earl G
761 Airport Road
Bethel, PA 19507-9696Bethel Township
Berks CountySCRO PAG123816 PAG-12 NPDES General Permit for CAFOs Renewal Horst Larry
1450 Hunsicker Road
Lancaster, PA 17601-5312Lykens Township
Dauphin CountySCRO PAG123817 PAG-12 NPDES General Permit for CAFOs Renewal Franklin View Farms
1700 Prospect Road
Washington Boro, PA 17582-9674Manor Township
Lancaster CountySCRO PAG123821 PAG-12 NPDES General Permit for CAFOs Renewal Schlappich Kimberly
1359 Main Street
Mohrsville, PA 19541-8768Centre Township
Berks CountySCRO PAG123889 PAG-12 NPDES General Permit for CAFOs Renewal Klines Hillside Turkey Farm
167 Coble Road
Chambersburg, PA 17202-9430Saint Thomas Township
Franklin CountySCRO PAG123914 PAG-12 NPDES General Permit for CAFOs Renewal Woglemuth Doug
1197 Landis Road
Elizabethtown, PA 17022-9799Mount Joy Borough
Lancaster CountySCRO PAG123954 PAG-12 NPDES General Permit for CAFOs New Wen Ridge Farm LLC
120 Leiby Road
Hamburg, PA 19526-8699Windsor Township
Berks CountySCRO PAG136347 PAG-13 NPDES General Permit for MS4s Renewal Finleyville Borough
Washington County
3515 Washington Avenue
Finleyville, PA 15332-1327Finleyville Borough
Washington CountySWRO 2124404 Pump Stations Individual WQM Permit New Middlesex Township Municipal Authority
Cumberland County
350 N Middlesex Road
Suite 2
Carlisle, PA 17013-8422Middlesex Township
Cumberland CountySCRO 4078401 Pump Stations Individual WQM Permit Amendment Hazle Township Municipal Authority
Luzerne County
P.O. Box 502
Harleigh, PA 18225-0502Hazle Township
Luzerne CountyNERO 0887403 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer Donald A & Lisa M Ammerman
1076 Homan Hill Road
Towanda, PA 18848-9519Sheshequin Township
Bradford CountyNCRO 2019403 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer March Garland
10611 Pine Road
Conneaut Lake, PA 16316-6729Vernon Township
Crawford CountyNWRO 2591413 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer Cassandra & Steven Wales
9451 Donation Road
Waterford, PA 16441-4233Summit Township
Erie CountyNWRO 2724403 Single Residence Sewage Treatment Plant Individual WQM Permit New Doane William
250 Pine Road
Pittsburgh, PA 15237Green Township
Forest CountyNWRO 4324401 Single Residence Sewage Treatment Plant Individual WQM Permit New Miller Robert J
8115 Pettis Road
Meadville, PA 16335West Salem Township
Mercer CountyNWRO 4398414 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer James & Nellie Jane Sauer
4930 Sandy Lake Greenville Road
Sandy Lake, PA 16145-2036Sandy Creek Township
Mercer CountyNWRO 6224406 Single Residence Sewage Treatment Plant Individual WQM Permit New BSRE Holdings LLC
915 N Plum Street
Lancaster, PA 17602-1937Glade Township
Warren CountyNWRO 6295403 Single Residence Sewage Treatment Plant Individual WQM Permit Transfer Brundage Kathleen
1725 Center Road
Columbus, PA 16405-2129Columbus Township
Warren CountyNWRO 6573407 Latrobe Municipal Authority Kingston Plant Amendment Latrobe Municipal Authority P.O. Box 88
Latrobe, PA 15650-0088Latrobe City Westmoreland County SWRO 2724402 Small Flow Treatment Facility Individual WQM Permit New Englert Pamela
2622 Neilltown Road
Pleasantville, PA 16341-5020Harmony Township
Forest CountyNWRO
II. Individual NPDES Permits—New, Renewal, and Major Amendment Applications and Draft Permits for Discharges Relating to Sewage, Industrial Waste, Industrial Stormwater, MS4s, Pesticides and CAFOs.
Northcentral Regional Office
PA0020486, Sewage, SIC Code 4952, Bellefonte Borough Authority, 236 W Lamb Street, Bellefonte, PA 16823-1502. Facility Name: Bellefonte Borough Wastewater Treatment Plant. This existing facility is located in Bellefonte Borough, Centre County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Spring Creek, is located in State Water Plan watershed 9-C and is classified for High Quality—Cold Water and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 3.22 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumDaily
MinimumAverage Monthly Daily
MaximumInstant.
MaximumFlow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Dissolved Oxygen XXX XXX Report
Inst MinXXX XXX XXX Carbonaceous Biochemical Oxygen Demand (CBOD5) 670 1,070
Wkly AvgXXX 25.0 40.0
Wkly Avg50 Biochemical Oxygen Demand (BOD5)
Raw Sewage InfluentReport Report XXX Report XXX XXX Total Suspended Solids
Raw Sewage InfluentReport Report XXX Report XXX XXX Total Suspended Solids 805 1,200
Wkly AvgXXX 30.0 45.0
Wkly Avg60 Fecal Coliform (No./100 ml)
Oct 1 - Apr 30XXX XXX XXX 2,000
Geo MeanXXX 10,000 May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report Ultraviolet light transmittance (%) XXX XXX Report XXX XXX XXX Nitrate-Nitrite as N XXX XXX XXX Report XXX XXX Nitrate-Nitrite as N (Total Load, lbs) (lbs) Report
Total MoXXX XXX XXX XXX XXX Total Nitrogen XXX XXX XXX Report XXX XXX Total Nitrogen (Total Load, lbs) (lbs) Report
Total MoXXX XXX XXX XXX XXX Ammonia-Nitrogen
Nov 1 - Apr 30240 360
Wkly AvgXXX 9.0 13.5
Wkly Avg18 May 1 - Oct 31 80 120
Wkly AvgXXX 3.0 4.5
Wkly Avg6 Ammonia-Nitrogen (Total Load, lbs) (lbs) Report
Total MoXXX XXX XXX XXX XXX Total Kjeldahl Nitrogen XXX XXX XXX Report XXX XXX Total Kjeldahl Nitrogen (Total Load, lbs) (lbs) Report
Total MoXXX XXX XXX XXX XXX Phosphorus, Dissolved 26 40
Wkly AvgXXX 1.0 1.5
Wkly Avg2 Total Phosphorus Report XXX XXX Report XXX XXX Total Phosphorus (Total Load, lbs) (lbs) Report
Total MoXXX XXX XXX XXX XXX Aluminum, Total (ug/L) Report Report XXX Report Report XXX Copper, Total (ug/L) Report Report XXX Report Report XXX Silver, Total (ug/L) Report Report XXX Report Report XXX 4,4-DDD (ug/L) 0.0001 0.0002 XXX 0.004 0.007 0.011 4,4-DDT (ug/L) 0.00004 0.00005 XXX 0.001 0.002 0.003 4,4-DDE (ug/L) 0.00002 0.00004 XXX 0.0009 0.001 0.002 Aldrin (ng/L) 0.000000936 0.000001 XXX 0.03 0.05 0.09 alpha-BHC (ug/L) 0.0005 0.0007 XXX 0.017 0.027 0.044 alpha-Endosulfan (ug/L) 0.009 0.013 XXX 0.32 0.5 0.8 beta-BHC (ug/L) 0.009 0.015 XXX 0.35 0.54 0.87 beta-Endosulfan (ug/L) Report Report XXX Report Report XXX Chlordane (ug/L) 0.0004 0.0005 XXX 0.013 0.02 0.033 Dieldrin (ng/L) 0.000001 0.000002 XXX 0.04 0.07 0.1 Endrin (ug/L) 0.003 0.005 XXX 0.12 0.19 0.31 Heptachlor (ug/L) 0.000007 0.00001 XXX 0.0003 0.0004 0.0007 Heptachlor Epoxide (ug/L) 0.00004 0.00005 XXX 0.001 0.002 0.003 Toxaphene (ug/L) 0.00005 0.00008 XXX 0.002 0.003 0.005 PFOA (ug/L) XXX XXX XXX XXX Report XXX PFOS (ug/L) XXX XXX XXX XXX Report XXX PFBS (ug/L) XXX XXX XXX XXX Report XXX HFPO-DA (ug/L) XXX XXX XXX XXX Report XXX The proposed monitoring requirements and effluent limits for implementation of Pennsylvania's Chesapeake Bay Watershed Implementation Plan are as follows for Outfall 001.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Monthly Annual Monthly Monthly Average Maximum Instant.
MaximumTotal Nitrogen (Total Load, lbs) (lbs)
Effluent NetXXX 58,812
Total AnnualXXX XXX XXX XXX Total Nitrogen (Total Load, lbs) (lbs) XXX Report
Total AnnualXXX XXX XXX XXX Ammonia-Nitrogen (Total Load, lbs) (lbs) XXX Report
Total AnnualXXX XXX XXX XXX Total Phosphorus (Total Load, lbs) (lbs)
Effluent NetXXX 7,842
Total AnnualXXX XXX XXX XXX Total Phosphorus (Total Load, lbs) (lbs) XXX Report
Total AnnualXXX XXX XXX XXX * This permit contains conditions which authorize the permittee to apply nutrient reduction credits to meet the Net Total Nitrogen and the Net Total Phosphorus effluent mass limits, under the Department's Chapter 96 regulations. The condition includes the requirement to report the application of these credits in Supplemental Discharge Monitoring Reports (DMRs) submitted to the Department.
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.
The EPA Waiver is not in effect.
Northcentral Regional Office
PA0113778, Sewage, SIC Code 6519, UMH Properties, Inc., 150 Clay Street, Morgantown, WV 26501-5942. Facility Name: Pleasant View Estates. This existing facility is located in South Centre Township, Columbia County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Unnamed Tributary to Susquehanna River (CWF), is located in State Water Plan watershed 5-D and is classified for Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.03 MGD.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Dissolved Oxygen XXX XXX Report
Inst MinXXX XXX XXX Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.6 Carbonaceous Biochemical Oxygen Demand (CBOD5) XXX XXX XXX 25.0 XXX 50.0 Total Suspended Solids XXX XXX XXX 30.0 XXX 60.0 Fecal Coliform (No./100 ml)
Oct 1 - Apr 30XXX XXX XXX 2,000
Geo MeanXXX 10,000 May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Ammonia-Nitrogen
Nov 1 - Apr 30XXX XXX XXX 18.0 XXX 36.0 May 1 - Oct 31 XXX XXX XXX 6.0 XXX 12.0 E. Coli (No./100 ml) XXX XXX XXX XXX Report XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.
The EPA Waiver is in effect.
Northeast Regional Office
PA0044466 A-2, Sewage, SIC Code 7032, Lake Bryn Mawr Operating Co., LLC, 593 Bryn Mawr Road, Honesdale, PA 18431-7884. Facility Name: Lake Bryn Mawr Camp Inc. This existing facility is located in Oregon Township, Wayne County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Unnamed Tributary to Big Brook (EV, MF), is located in State Water Plan watershed 1-B and is classified for Exceptional Value and Migratory Fish, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.012 MGD—Interim Limits.
(From Permit Effective Date to One Year After Permit Effective Date)
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX Total Residual Chlorine (TRC) XXX XXX XXX 0.035 XXX 0.115 The proposed effluent limits for Outfall 001 are based on a design flow of 0.012 MGD—Final Limits.
(From One Years After Permit Effective Date to Permit Expiration Date)
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX Total Residual Chlorine (TRC) XXX XXX XXX 0.034 XXX 0.111 The proposed effluent limits for Outfall 001 are based on a design flow of 0.012 MGD.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX 9.0
Avg MoXXX Dissolved Oxygen XXX XXX 6.0
Inst MinXXX XXX XXX Carbonaceous Biochemical Oxygen Demand (CBOD5) XXX XXX XXX 25.0 XXX 50.0 Carbonaceous Biochemical Oxygen Demand (CBOD5)
Raw Sewage InfluentXXX XXX XXX Report XXX XXX CBOD5 Minimum % Removal (%) XXX XXX XXX 85.0
Min Mo AvgXXX XXX Total Suspended Solids XXX XXX XXX 30.0 XXX 60.0 Fecal Coliform (No./100 ml) XXX XXX XXX 200
Geo MeanXXX 1,000 Nitrate-Nitrite as N XXX XXX XXX Report XXX XXX Total Nitrogen XXX XXX XXX Report XXX XXX Ammonia-Nitrogen
Nov 1 - Apr 30XXX XXX XXX 5.31 XXX 10.62 May 1 - Oct 31 XXX XXX XXX 1.77 XXX 3.54 Total Kjeldahl Nitrogen XXX XXX XXX Report XXX XXX Total Phosphorus XXX XXX XXX Report XXX XXX Total Dissolved Solids XXX XXX XXX Report
Avg QrtlyXXX XXX E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report In addition, the permit contains the following major special conditions:
• Solids Management
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-826-5472.
The EPA Waiver is in effect.
Northeast Regional Office
PA0053911, Sewage, SIC Code 4952, East Bangor Borough Municipal, 555 West Central Avenue, East Bangor, PA 18013-2123. Facility Name: East Bangor Municipal Authority. This existing facility is located in East Bangor Borough, Northampton County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Unnamed Tributary to Martins Creek (CWF, MF), is located in State Water Plan watershed 1-F and is classified for Cold Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0.1 MGD.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageMinimum Average Monthly Weekly
AverageIMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Dissolved Oxygen XXX XXX 5.0
Inst MinXXX XXX XXX Total Residual Chlorine (TRC) XXX XXX XXX 0.14 XXX 0.46 Carbonaceous Biochemical Oxygen Demand (CBOD5)
Nov 1 - Apr 3020.9 33.4 XXX 25.0 40.0 50.0 May 1 - Oct 31 16.7 25.0 XXX 20.0 30.0 40.0 Biochemical Oxygen Demand (BOD5)
Raw Sewage InfluentReport XXX XXX Report Report
Daily MaxXXX Total Suspended Solids
Raw Sewage InfluentReport XXX XXX Report Report
Daily MaxXXX Total Suspended Solids 25.0 37.5 XXX 30.0 45.0 60.0 Fecal Coliform (No./100 ml)
Oct 1 - Apr 30XXX XXX XXX 2,000
Geo MeanXXX 10,000 May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Ammonia-Nitrogen
Nov 1 - Apr 3010.0 XXX XXX 12.0 Report
Daily Max24.0 May 1 - Oct 31 3.4 XXX XXX 4.0 Report
Daily Max8.0 Zinc, Total Report XXX XXX 0.166 0.259
Daily Max0.332 Total Dissolved Solids Report
Avg QrtlyXXX XXX Report
Avg QrtlyReport
Daily MaxXXX E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report Nitrate-Nitrite as N Report
Avg QrtlyXXX XXX Report
Avg QrtlyReport
Daily MaxXXX Total Nitrogen Report
Avg QrtlyXXX XXX Report
Avg QrtlyReport
Daily MaxXXX Total Kjeldahl Nitrogen Report
Avg QrtlyXXX XXX Report
Avg QrtlyReport
Daily MaxXXX Total Phosphorus Report
Avg QrtlyXXX XXX Report
Avg QrtlyReport
Daily MaxXXX In addition, the permit contains the following major special conditions:
• Solids Management
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-826-5472.
Northeast Regional Office
PAI132231, MS4, Alburtis Borough, Lehigh County, 260 Franklin Street, Alburtis, PA 18011.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Alburtis Borough, Lehigh County. The receiving streams, Little Lehigh Creek (HQ-CWF, MF) and Swabia Creek (HQ-CWF, MF), are located in State Water Plan watershed 2-C and is classified for High Quality—Cold Water and Migratory Fish, aquatic life, water supply and recreation. The applicant is classified as a small MS4.
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-826-5472.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Northeast Regional Office
PAS802203, Storm Water, SIC Code 3700, 3711, Mack Trucks Inc., 7000 Alburtis Road, Macungie, PA 18062-9632. Facility Name: Mack Trucks Inc. This existing facility is located in Lower Macungie Township, Lehigh County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial stormwater.
The receiving stream(s), Swabia Creek (HQ-CWF, MF), is located in State Water Plan watershed 2-C and is classified for High Quality—Cold Water and Migratory Fish, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX pH (S.U.) XXX XXX Report
Inst MinXXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX XXX Report Total Suspended Solids XXX XXX XXX XXX XXX Report Oil and Grease XXX XXX XXX XXX XXX Report Total Nitrogen XXX XXX XXX XXX XXX Report Total Phosphorus XXX XXX XXX XXX XXX Report The proposed effluent limits for Outfall 002 are based on a design flow of 0 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Maximum IMAX pH (S.U.) XXX XXX Report
Inst MinXXX XXX Report Chemical Oxygen Demand (COD) XXX XXX XXX XXX XXX Report Total Suspended Solids XXX XXX XXX XXX XXX Report Oil and Grease XXX XXX XXX XXX XXX Report Total Nitrogen XXX XXX XXX XXX XXX Report Total Phosphorus XXX XXX XXX XXX XXX Report In addition, the permit contains the following major special conditions:
• Stormwater Outfalls and Authorized Non-Stormwater Discharges
• Best Management Practices (BMPs)
• Routine Inspections
• Preparedness, Prevention and Contingency (PPC) Plan
• Stormwater Monitoring Requirements
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-826-5472.
The EPA Waiver is in effect.
Southeast Regional Office
PA0027294, Sewage, SIC Code 4952, Bristol Borough Water & Sewer Authority, 250 Pond Street, Bristol, PA 19007-4937. Facility Name: Bristol Borough WPC Plant. This existing facility is located in Bristol Borough, Bucks County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Delaware River (WWF, MF), is located in State Water Plan watershed 2-E and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 2.7 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageMinimum Monthly
AverageAverage Monthly Daily
MaximumIMAX PCBs Dry Weather Analysis (pg/L) XXX XXX XXX XXX Report XXX PCBs Wet Weather Analysis (pg/L) XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 001 are based on a design flow of 2.7 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageMinimum Monthly
AverageAverage Monthly Daily
MaximumIMAX Total Dissolved Solids Report
Avg QrtlyReport
Daily MaxXXX 1,000.0
Avg Qrtly2,000.0 2,500 Total Nitrogen Report
Avg QrtlyXXX XXX Report
Avg QrtlyXXX XXX Total Phosphorus Report
Avg QrtlyXXX XXX Report
Avg QrtlyXXX XXX PFOA (ng/L) XXX XXX XXX XXX Report XXX PFOS (ng/L) XXX XXX XXX XXX Report XXX PFBS (ng/L) XXX XXX XXX XXX Report XXX HFPO-DA (ng/L) XXX XXX XXX XXX Report XXX Toxicity, Chronic - Ceriodaphnia Survival (TUc) XXX XXX XXX XXX Report XXX Toxicity, Chronic - Ceriodaphnia Reproduction (TUc) XXX XXX XXX XXX Report XXX Toxicity, Chronic - Pimephales
Survival (TUc)XXX XXX XXX XXX Report XXX Toxicity, Chronic - Pimephales Growth (TUc) XXX XXX XXX XXX Report XXX The proposed effluent limits for Outfall 001 are based on a design flow of 2.7 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageMinimum Monthly
AverageAverage Monthly Daily
MaximumIMAX Flow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Dissolved Oxygen XXX XXX 4.0
Inst MinXXX XXX XXX Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.6 Carbonaceous Biochemical Oxygen Demand (CBOD5) 366 549 XXX 17 26
Wkly Avg34 Carbonaceous Biochemical Oxygen Demand (CBOD5)
Raw Sewage InfluentReport XXX XXX Report XXX XXX Biochemical Oxygen Demand (BOD5)
Raw Sewage InfluentReport XXX XXX Report XXX XXX CBOD5 Minimum % Removal (%)
Percent RemovalXXX XXX 88.50 XXX XXX XXX Total Suspended Solids
Raw Sewage InfluentReport XXX XXX Report XXX XXX Total Suspended Solids 676 1,013 XXX 30 45
Wkly Avg60 Fecal Coliform (No./100 ml)
Oct 1 - Apr 30XXX XXX XXX 200
Geo MeanXXX 1,000 May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report Ammonia-Nitrogen 450 XXX XXX 20.0 XXX 40 In addition, the permit contains the following major special conditions:
• No stormwater shall be directed into sanitary sewers associated with approved discharge
• Proper disposal of collected screenings, slurries, sludges, and other solids
• Permittee shall optimize chlorine dosages used for disinfection to minimize TRC in effluent
• Permittee shall notify DEP of operator in responsible charge
• Permittee shall develop and maintain treatment facility operations & maintenance (O & M) plan
• Permittee shall manage and properly dispose of sewage sludge and biosolids
• Whole Effluent Toxicity requirement
• PCB pollutant minimization plan and monitoring
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is not in effect.
Southeast Regional Office
PA0052663, Sewage, SIC Code 4952, Knights Bridge Corp, 112 Chesley Drive, Suite 200, Media, PA 19063-1762. Facility Name: Knights Bridge STP. This existing facility is located in Chadds Ford Township, Delaware County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Unnamed Tributary to Harvey Run (WWF, MF), is located in State Water Plan watershed 3-H and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of .09 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Instantaneous
MinimumAverage Monthly Maximum IMAX Flow (MGD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Dissolved Oxygen XXX XXX 5.0 XXX XXX XXX Carbonaceous Biochemical Oxygen Demand (CBOD5)
Nov 1 - Apr 3015 XXX XXX 20 XXX 40 May 1 - Oct 31 7.5 XXX XXX 10 XXX 20 Biochemical Oxygen Demand (BOD5)
Raw Sewage InfluentReport XXX XXX Report XXX XXX Total Suspended Solids 7.5 XXX XXX 10 XXX 20 Total Suspended Solids
Raw Sewage InfluentReport XXX XXX Report XXX XXX Fecal Coliform (No./100 ml) XXX XXX XXX 200
Geo MeanXXX 1,000 E. Coli (No./100 ml) XXX XXX Report XXX XXX 100 Nitrate-Nitrite as N 7.5 XXX XXX 10.0 XXX 20 Total Nitrogen 7.5 XXX XXX 10.0 XXX 20 Ammonia-Nitrogen
Nov 1 - Apr 302.3 XXX XXX 3.0 XXX 6 May 1 - Oct 31 0.8 XXX XXX 1.0 XXX 2 Total Phosphorus 0.37 XXX XXX 0.5 XXX 1 Ultraviolet light dosage
(mjoules/cm2)XXX XXX Report XXX XXX XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is not in effect.
Southeast Regional Office
PA0058343, Sewage, SIC Code 4952, Bedminster Municipal Authority, 442 Elephant Road, Perkasie, PA 18944-4163. Facility Name: Bedminster STP. This existing facility is located in Bedminster Township, Bucks County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream, Unnamed Tributary to Deep Run (WWF), is located in State Water Plan watershed 2-D and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of .302 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageDaily
MinimumAverage Monthly Weekly
AverageIMAX Total Dissolved Solids XXX XXX XXX Report
Avg QrtlyXXX XXX E. Coli (No./100 ml) XXX XXX XXX XXX XXX Report The proposed effluent limits for Outfall 001 are based on a design flow of .302 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageDaily
MinimumAverage Monthly Weekly
AverageIMAX Flow (MGD) Report XXX XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Dissolved Oxygen XXX XXX 5.0
Inst MinXXX XXX XXX Carbonaceous Biochemical Oxygen Demand (CBOD5)
Nov 1 - Apr 3050 76 XXX 20.0 30.0 40 May 1 - Oct 31 25 38 XXX 10.0 15.0 20 Carbonaceous Biochemical Oxygen Demand (CBOD5)
Raw Sewage InfluentReport Report XXX Report Report XXX Biochemical Oxygen Demand (BOD5)
Raw Sewage InfluentReport Report XXX Report Report XXX Total Suspended Solids
Raw Sewage InfluentReport Report XXX Report Report XXX Total Suspended Solids 25 38 XXX 10.0 15.0 20 Fecal Coliform (No./100 ml)
Oct 1 - Apr 30XXX XXX XXX 200.0
Geo MeanXXX 1,000.0 May 1 - Sep 30 XXX XXX XXX 200.0
Geo MeanXXX 1,000.0 Ultraviolet light intensity
(mW/cm2)XXX XXX Report XXX XXX XXX Nitrate-Nitrite as N 25 XXX XXX 10.0 XXX 20 Total Nitrogen XXX XXX XXX Report XXX XXX Ammonia-Nitrogen
Nov 1 - Apr 305 XXX XXX 2.0 XXX 4 May 1 - Oct 31 2.5 XXX XXX 1.0 XXX 2 Total Phosphorus
Nov 1 - Apr 301.51 XXX XXX 0.6 XXX 1.2 May 1 - Oct 31 1.26 XXX XXX 0.5 XXX 1 In addition, the permit contains the following major special conditions:
A. No stormwater
B. Acquire Necessary Property Rights
C. Proper Sludge Disposal
D. Chlorine Optimization
E. Dry Stream Discharge
F. Wastewater Associated with Oil and Gas Extraction
G. Operator Notification
H. Operations and maintenance plan
I. SPW Discharge
J. Hauled-in Waste Restrictions
K. Compliance with Part A, Additional Requirements
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is in effect.
Southeast Regional Office
PA0056804, Industrial, SIC Code 4941, North Penn North Wales Water Authority, Montgomery County, P.O. Box 317, Chalfont, PA 18914-0317. Facility Name: Forest Park WTP. This existing facility is located in Chalfont Borough, Bucks County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial waste.
The receiving stream(s), Pine Run (TSF, MF), is located in State Water Plan watershed 2-F and is classified for Trout Stocking and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of 1.94 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumInstant.
MaximumFlow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Total Residual Chlorine (TRC) XXX XXX XXX 0.24 XXX 0.56 Total Suspended Solids 324 647 XXX 20.0 40.0 50 Total Phosphorus 8 16 XXX 0.5 1.0 1.25 Aluminum, Total 16 32 XXX 1.0 2.0 2.5 Iron, Total 32 64 XXX 2.0 4.0 5 Manganese, Total 16 32 XXX 1.0 2.0 2.5 Chlorodibromomethane XXX XXX XXX Report Report XXX Dichlorobromomethane XXX XXX XXX Report Report XXX Chloroform XXX XXX XXX Report Report XXX PFOA XXX XXX XXX Report
Avg QrtlyReport XXX PFOS XXX XXX XXX Report
Avg QrtlyReport XXX The proposed effluent limits for Outfall 002 are based on a design flow of 1.94 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumMinimum Average Monthly Daily
MaximumInstant.
MaximumFlow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Total Residual Chlorine (TRC) XXX XXX XXX 0.24 XXX 0.56 Total Suspended Solids 324 647 XXX 20.0 40.0 50 Total Phosphorus 8 16 XXX 0.5 1.0 1.25 Aluminum, Total 11 22 XXX 1.0 2.0 2.5 Iron, Total 32 64 XXX 2.0 4.0 5 Manganese, Total 16 32 XXX 1.0 2.0 2.5 Chlorodibromomethane XXX XXX XXX Report Report XXX Dichlorobromomethane XXX XXX XXX Report Report XXX Chloroform XXX XXX XXX Report Report XXX PFOA XXX XXX XXX Report
Avg QrtlyReport XXX PFOS XXX XXX XXX Report
Avg QrtlyReport XXX In addition, the permit contains the following major special conditions:
• Proper Sludge Disposal
• BAT/BCT Standards
• Chlorine Minimization
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA Waiver is in effect.
Southeast Regional Office
PAI130043, MS4, Ambler Borough, Montgomery County, 131 Rosemary Avenue, Ambler, PA 19002.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Ambler Borough, Montgomery County. The receiving stream(s), Unnamed Tributary to Wissahickon Creek (TSF, MF), is located in State Water Plan watershed 3-F and is classified for Trout Stocking and Migratory Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.
The applicant has is required to the following plan(s) with the application to reduce pollutant loads to impaired waters:
• A Pollutant Reduction Plan (PRP)
• A Total Maximum Daily Load (TMDL) Plan
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Southeast Regional Office
PAI130050, MS4, Lower Southampton Township, Bucks County, 1500 Desire Avenue, Feasterville, PA 19053.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Lower Southampton Township, Bucks County. The receiving stream(s), Poquessing Creek (WWF, MF), is located in State Water Plan watershed 3-J and is classified for Warm Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.
The applicant has submitted the following plan(s) with the application to reduce pollutant loads to impaired waters:
• A Pollutant Reduction Plan (PRP)
• A Total Maximum Daily Load (TMDL) Plan
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Southeast Regional Office
PAI130057, MS4, Montgomery Township, Montgomery County, 1001 Stump Road, Montgomeryville, PA 18936-9605.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Montgomery Township, Montgomery County. The receiving stream(s), Wissahickon Creek (TSF, MF), Little Neshaminy Creek (WWF, MF), and Unnamed Tributary of West Branch Neshaminy Creek (WWF, MF), is located in State Water Plan watershed 2-F and 3-F and is classified for Trout Stocking, Migratory Fishes, and Warm Water Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.
The applicant has submitted the following plan(s) with the application to reduce pollutant loads to impaired waters:
• A Pollutant Reduction Plan (PRP)
• A Total Maximum Daily Load (TMDL) Plan
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Southeast Regional Office
PAI130069, MS4, Souderton Borough, Montgomery County, 31 West Summit Street, Souderton, PA 18964.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Souderton Borough, Montgomery County. The receiving stream(s), Unnamed Tributary to Skippack Creek (TSF, MF), is located in State Water Plan watershed 3-E and is classified for Trout Stocking and Migratory Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.
The applicant is required to submit the following plan(s) with the application to reduce pollutant loads to impaired waters:
• A Pollutant Reduction Plan (PRP)
• A Total Maximum Daily Load (TMDL) Plan
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Southeast Regional Office
PAI130070, MS4, Springfield Township, Montgomery County, 1510 Paper Mill Road, Wyndmoor, PA 19038-7032.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Springfield Township, Montgomery County. The receiving stream(s), Unnamed Tributary of Wissahickon Creek (TSF, MF), Sandy Run (TSF, MF), and Unnamed Tributary to Schuylkill River (WWF, MF), is located in State Water Plan watershed 3-F and is classified for Trout Stocking, Migratory Fishes, and Warm Water Fishes, aquatic life, water supply and recreation. The applicant is classified as a small MS4.
The applicant has submitted the following plan(s) with the application to reduce pollutant loads to impaired waters:
• A Pollutant Reduction Plan (PRP)
• A Total Maximum Daily Load (TMDL) Plan
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Southeast Regional Office
PAI130086, MS4, Lower Moreland Township, Montgomery County, 640 Red Lion Road, Huntingdon Valley, PA 19006-6217.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Lower Moreland Township, Montgomery County. The receiving stream(s), Unnamed Tributary to Poquessing Creek (WWF, MF), Huntingdon Valley Creek (TSF, MF), Terwood Run (TSF, MF), Unnamed Tributary to Southampton Creek (TSF, MF), and Unnamed Tributary to Pennypack Creek (TSF, MF), is located in State Water Plan watershed 3-J and is classified for Trout Stocking, Migratory Fishes, and Warm Water Fishes, aquatic life, water supply and recreation. The applicant is classified as a smalll MS4.
The applicant has submitted the following plan(s) with the application to reduce pollutant loads to impaired waters:
• A Pollutant Reduction Plan (PRP)
• A Total Maximum Daily Load (TMDL) Plan
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Southeast Regional Office
PAI130529, MS4, Wallace Township, P.O. Box 670, Glenmoore, PA 19343-0670.
The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Wallace Township, Chester County. The receiving stream(s), Indian Run (HQ-CWF, MF), Unnamed Tributary to Culbertson Run (HQ-TSF, MF), and Unnamed Tributary to East Branch Brandywine Creek (HQ-TSF, MF), is located in State Water Plan watershed 3-H and is classified for High Quality—Cold Water, High Quality Waters—Trout Stocking, and Migratory Fish, aquatic life, water supply and recreation. The applicant is classified as a small MS4.
The applicant has submitted the following plan(s) with the application to reduce pollutant loads to impaired waters:
• A Total Maximum Daily Load (TMDL) Plan
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 484-250-5910.
The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.
Southwest Regional Office
PA0040177, Industrial, SIC Code 4941, Pennsylvania American Water, 1 Water Street, Camden, NJ 08102. Facility Name: Brownsville WTP. This existing facility is located in Brownsville Borough, Fayette County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial waste.
The receiving stream, Monongahela River (WWF), is located in State Water Plan watershed 19-C and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of .090 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumInstant. Minimum Average Monthly Daily
MaximumInstant. Maximum Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine (TRC) XXX XXX XXX 0.5 1.0 XXX Total Suspended Solids XXX XXX XXX 30.0 60.0 XXX Aluminum, Total XXX XXX XXX 4.0 8.0 XXX Iron, Total XXX XXX XXX 2.0 4.0 XXX Manganese, Total XXX XXX XXX 1.0 2.0 XXX You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is in effect.
Southwest Regional Office
PA0218863, Industrial, SIC Code 4911, Fayette Power Co. LLC, 100 Energy Drive, Masontown, PA 15461-2588. Facility Name: Fayette Energy Facility. This existing facility is located in German Township, Fayette County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated industrial waste.
The receiving stream(s), Unnamed Tributary to Monongahela River (WWF) and Monongahela River (WWF), is located in State Water Plan watershed 19-C and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on an average flow of 0.67 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumInstant. Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Residual Chlorine (TRC) XXX XXX XXX 0.5 XXX 1.0 Temperature (°F) XXX XXX XXX XXX XXX 110 Total Dissolved Solids XXX XXX XXX Report Report XXX Total Suspended Solids XXX XXX XXX Report Report XXX Oil and Grease XXX XXX XXX Report Report XXX PFOA (ng/L) XXX XXX XXX XXX Report XXX PFOS (ng/L) XXX XXX XXX XXX Report XXX PFBS (ng/L) XXX XXX XXX XXX Report XXX HFPO-DA (ng/L) XXX XXX XXX XXX Report XXX The proposed effluent limits for IMP 101:
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumInstant. Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Free Available Chlorine XXX XXX XXX 0.2 XXX 0.5 Total Suspended Solids XXX XXX XXX 30.0 100.0 XXX Oil and Grease XXX XXX XXX 15.0 20.0 XXX Zinc, Total XXX XXX XXX 1.0
Avg Qrtly1.0 XXX The proposed effluent limits for IMP 201:
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Daily
MaximumInstant. Minimum Average Monthly Daily
MaximumIMAX Flow (MGD) Report Report XXX XXX XXX XXX pH (S.U.) XXX XXX 6.0 XXX XXX 9.0 Total Suspended Solids XXX XXX XXX 30.0 100.0 XXX Oil and Grease XXX XXX XXX 15.0 20.0 XXX The proposed effluent limits for Outfall 002:
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Average Weekly Minimum Average Monthly Daily
MaximumIMAX pH (S.U.) XXX XXX XXX XXX Report XXX Total Suspended Solids XXX XXX XXX XXX Report XXX Oil and Grease XXX XXX XXX XXX Report XXX Total Nitrogen XXX XXX XXX XXX Report XXX Total Phosphorus XXX XXX XXX XXX Report XXX Iron, Total XXX XXX XXX XXX Report XXX In addition, the permit contains the following major special conditions:
Other Requirements
In conformance with 40 CFR 122.44(a)(2) a monitoring waiver may be granted for pollutants that are not present in the discharge. Historical data has shown consistent non-detects for total chromium. As such, monitoring for total chromium has been removed in accordance with 40 CFR 122.44(a)(2). However, this regulation does not waive the permit limitations for all applicable guideline-listed pollutants. Therefore, a monitoring waiver is granted for total chromium, however, the limitations shall remain in effect as listed as follows. The permittee must still sample total chromium as part of the required testing for the next permit renewal application.
Concentration Limits (mg/L) Pollutant Average
MonthlyDaily
MaximumChromium, Total 0.2 0.2 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is not in effect.
Southwest Regional Office
PA0023141, Sewage, SIC Code 4952, Hastings Area Sewer Authority, 207-1 5th Avenue, Hastings, PA 16646-0559. Facility Name: Hastings Municipal Authority. This existing facility is located in Hastings Borough, Cambria County.
Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated sewage.
The receiving stream(s), Brubaker Run (CWF), is located in State Water Plan watershed 8-B and is classified for Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.
The proposed effluent limits for Outfall 001 are based on a design flow of .6 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageAverage Monthly Weekly
AverageMaximum Instant.
MaximumFlow (MGD) Report Report
Daily MaxXXX XXX XXX XXX pH (S.U.) XXX XXX 6.0
Inst MinXXX XXX 9.0 Dissolved Oxygen XXX XXX 6.0
Inst MinXXX XXX XXX Carbonaceous Biochemical Oxygen Demand (CBOD5)
Nov 1 - Apr 30115.1 172.6 23.0 34.5 XXX 46 May 1 - Oct 31 85.1 127.6 17.0 25.5 XXX 34 Biochemical Oxygen Demand (BOD5)
Raw Sewage InfluentReport Report
Daily MaxReport XXX XXX XXX Total Suspended Solids 150.12 225.18 30.0 45.0 XXX 60 Total Suspended Solids
Raw Sewage InfluentReport Report
Daily MaxReport XXX XXX XXX Fecal Coliform (No./100 ml)
Oct 1 - Apr 30XXX XXX XXX 2,000
Geo MeanXXX 10,000 May 1 - Sep 30 XXX XXX XXX 200
Geo MeanXXX 1,000 Ultraviolet light intensity
(mW/cm2)XXX XXX Report
Inst MinXXX XXX XXX Ammonia-Nitrogen
Nov 1 - Apr 3020.01 XXX 4.0 XXX XXX 8 May 1 - Oct 31 10.0 XXX 2.0 XXX XXX 4 Total Phosphorus Report XXX Report XXX XXX XXX
The proposed effluent limits for Outfall 001 are based on a design flow of .6 MGD.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Average Monthly Weekly
AverageAverage Monthly Weekly
AverageMaximum Instant.
MaximumE. Coli (No./100 ml) XXX XXX XXX XXX XXX Report Copper, Total Report
Avg QrtlyReport
Daily MaxXXX Report
Avg QrtlyReport
Daily MaxXXX Zinc, Total Report
Avg QrtlyReport
Daily MaxXXX Report
Avg QrtlyXXX XXX
The proposed monitoring requirements and effluent limits for implementation of Pennsylvania's Chesapeake Bay Watershed Implementation Plan are as follows for Outfall 001.—Limits.
Mass Units (lbs/day) Concentrations (mg/L) Parameters Monthly Annual Monthly Monthly
AverageMaximum Instant.
MaximumAmmonia—N Report Report XXX Report XXX XXX Kjeldahl—N Report XXX XXX Report XXX XXX Nitrate-Nitrite as N Report XXX XXX Report XXX XXX Total Nitrogen Report Report XXX Report XXX XXX Total Phosphorus Report Report XXX Report XXX XXX Net Total Nitrogen Report 10959 XXX XXX XXX XXX Net Total Phosphorus Report 1461 XXX XXX XXX XXX
* This permit contains conditions which authorize the permittee to apply nutrient reduction credits to meet the Net Total Nitrogen and the Net Total Phosphorus effluent mass limits, under the Department's Chapter 96 regulations. The condition includes the requirement to report the application of these credits in Supplemental Discharge Monitoring Reports (DMRs) submitted to the Department.
You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 412-442-4000.
The EPA Waiver is not in effect.
III. Individual NPDES Permit Applications for Discharges of Stormwater Associated with Construction Activity.
Northeast Regional Office
Applicant: Innovative Office Products LLC
Applicant Address: 100 Kuebler Road, Easton, PA 18040
Application Number: PAD480102
Application Type: Renewal
Municipality/County: Forks Township, Northampton County
Project Site Name: Innovative Office Products Expansion
Total Earth Disturbance Area (acres): 9.91 acres
Surface Waters Receiving Stormwater Discharges: Bushkill Creek (HQ-CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Construction of an approx. 39,300 sq. ft. building expansion with accommodations for a future 30,900 sq. ft. expansion. Site improvements include relocation of internal driveway, expansion of parking area and truck loading area, storm sewer systems, and an infiltration basin
Special Conditions: NA—No site-specific special conditions proposed.
You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.
Northeast Regional Office
Applicant: Robert Mathewson Jr.
Applicant Address: P.O. Box 781, Blakeslee, PA 18610
Application Number: PAD450209
Application Type: New
Municipality/County: Barrett Township, Monroe County
Project Site Name: Mathewson Home Site
Total Earth Disturbance Area (acres): 3.34 acres
Surface Waters Receiving Stormwater Discharges: Leavitt Branch (HQ-CWF, MF); Goose Pond Run (HQ-CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Construction of a single-family home and driveway, including utility installation and three (3) stormwater management basins
Special Conditions: NA—No site-specific special conditions proposed.
You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.
Southcentral Regional Office
Applicant: Heritage Estates LLC
Applicant Address: 19 Independence Drive, Shippensburg, PA 17257
Application Number: PAD280023
Application Type: New
Municipality/County: Antrim Township, Franklin County
Project Site Name: Heritage Estates
Total Earth Disturbance Area (acres): 41.27 acres
Surface Waters Receiving Stormwater Discharges: Muddy Run (HQ-CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Construction of a residential development consisting of 48 single family homes and 65 townhouse units with stormwater management facilities.
Special Conditions: Wetland Monitoring
You may review the permit application file by contacting DEP's File Review Coordinator at 717-705-4802.
Southcentral Regional Office
Applicant: CCD Rock Creek, LLC
Applicant Address: 1751 A West Diehl Road, Naperville, IL 60563
Application Number: PAD010001 A-2
Application Type: Major Amendment
Municipality/County: Straban Township, Adams County
Project Site Name: Amblebrook
Total Earth Disturbance Area (acres): 79.2 acres
Surface Waters Receiving Stormwater Discharges: UNT to Rock Creek (WWF, MF) and EV Wetlands
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Construction of 261 dwelling units as a continuation of the existing portions of the project
Special Conditions: Wetland Monitoring
You may review the permit application file by contacting DEP's File Review Coordinator at 717-705-4802.
Northeast Regional Office
Applicant: Sheetz, Inc.
Applicant Address: 351 Sheetz Way, Claysburg, PA 16625-8346
Application Number: PAD480220
Application Type: New
Municipality/County: Hellertown Borough, Northampton County
Project Site Name: Proposed Sheetz—Hellertown
Total Earth Disturbance Area (acres): 2.68 acres
Surface Waters Receiving Stormwater Discharges: Saucon Creek (HQ-CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: The applicant is proposing to redevelop the property with a 1-story, 6,132 SF gas station with convenience store. The site will also contain related site amenities and improvements inclusive of parking, landscaping, ADA facilities, lighting, utilities, stormwater management facilities, retaining walls, gas canopy with pumping stations, and an access drive to Kichline Ave.
Special Conditions: NA—No site-specific special conditions proposed.
You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.
Northcentral Regional Office
Applicant: Jonas L. & Lydia P. Beiler
Applicant Address: 112 Milky Way, Spring Mills, PA 16875
Application Number: PAD140116
Application Type: New
Municipality/County: Gregg Township, Centre County
Project Site Name: Beiler Wood Drying Kiln & Storage
Total Earth Disturbance Area (acres): 4.68 acres
Surface Waters Receiving Stormwater Discharges: Penns Creek (HQ-CWF, MF), UNT to Penns Creek (CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: The applicant proposes construction of a sawmill, wood drying kiln, storage building, access driveway, pad, and associated stormwater management.
Special Conditions: N/A
You may review the permit application file by contacting DEP's File Review Coordinator at 570-327-3693.
Northeast Regional Office
Applicant: Sunrise Lehighton Group, LLC
Applicant Address: 3008 Willow Court, Bethlehem, PA 18020-7690
Application Number: PAD130047
Application Type: New
Municipality/County: Towamensing Township, Carbon County
Project Site Name: Lakeside Self Storage—10 Homestead Lane
Total Earth Disturbance Area (acres): 1.98 acres
Surface Waters Receiving Stormwater Discharges: 1. Hunter Creek (HQ-CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: A self-storage facility, parking, widening of an existing road, and stormwater management facilities.
Special Conditions: NA—No site-specific special conditions proposed.
You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.
Southcentral Regional Office
Applicant: Stoner Inc.
Applicant Address: 1070 Robert Fulton Highway, Quarryville, PA 17566
Application Number: PAD360125
Application Type: New
Municipality/County: East Drumore Township, Lancaster County
Project Site Name: Stoner Inc.
Total Earth Disturbance Area (acres): 1.95 acres
Surface Waters Receiving Stormwater Discharges: UNT to Stewart Run (HQ-CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Construct new building addition, parking expansion and SWM facilities.
Special Conditions: N/A
You may review the permit application file by contacting DEP's File Review Coordinator at 717-705-4802.
Southeast Regional Office
Applicant: Energy Transfer Marketing & Terminals, L.P.
Applicant Address: 100 Green Street, Marcus Hook, PA 19061
Application Number: PAD230081
Application Type: New
Municipality/County: Marcus Hook Borough, Delaware County
Project Site Name: Mariner East Ethane Expansion and Chilling
Total Earth Disturbance Area (acres): 28.5 acres
Surface Waters Receiving Stormwater Discharges: Delaware River via storm sewer to DELCORA (WWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Energy Transfer is proposing to redevelop a portion of the Marcus Hook Terminal and install a system designed to process an incoming ethane stream into a saleable ethane product. The project includes the installation of two new 600,000 barrel (bbl) ethane storage tanks, a new cold flare, a new dehydration and refrigeration system, a demethanizer rectifier, a wet surface air cooling system, an operator shelter, and two new high voltage power lines. Also included are additional demolition of existing equipment and structures, and the installation of two cooling tower basins, gas distribution and dehydration equipment, power distribution buildings and transformers, and associated equipment piping, pipe racks, and steel structures.
Special Conditions: N/A
You may review the permit application file by contacting DEP's File Review Coordinator at 484-250-5910.
Southeast Regional Office
Applicant: GS Great Valley Property Owner MF, LLC and GS Great Valley Property Owner AA, LLC
Applicant Address: 161 Washington Street, Conshohocken, PA 19428-2802
Application Number: PAD150348
Application Type: New
Municipality/County: East Whiteland Township, Chester County
Project Site Name: GVCC Residential Development
Total Earth Disturbance Area (acres): 13.14 acres
Surface Waters Receiving Stormwater Discharges: Tributary to Valley Creek (EV, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: This site is located in East Whiteland Township. This project includes the construction of two apartment buildings, parking lots, driveways, and amenity spaces. One rain garden and two subsurface beds will be utilized to comply with the Township's stormwater peak rate control and volume control requirements. Due to the underlying karst soils on the site, infiltration will not be utilized as a part of the design. Managed release concept systems will be utilized an alternative to meet the Township and State infiltration and volume requirements.
Special Conditions: N/A
You may review the permit application file by contacting DEP's File Review Coordinator at 484-250-5910.
Northeast Regional Office
Applicant: Landston Equities, LLC, c/o David Jaindl
Applicant Address: 3150 Coffeetown Road, Orefield, PA 18069
Application Number: PAD390314
Application Type: New
Municipality/County: Lower Macungie Township, Lehigh County
Project Site Name: Lehigh Valley Town Center
Total Earth Disturbance Area (acres): 46.0 acres
Surface Waters Receiving Stormwater Discharges: UNT to Little Lehigh Creek (HQ-CWF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Landston Equities is proposing a mixed-use development which will include a variety of commercial uses. It will also include the construction of roadways, parking, water line, sanitary sewer, and associated detention and spray irrigation facilities.
Special Conditions: NA—No site-specific special conditions proposed.
You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.
Southwest Regional Office
Applicant: 4137 Bakerstown Road, LLC
Applicant Address: 2 Manhattanville Road, Suite 403, Purchase, NY 10577
Application Number: PAD020020
Application Type: Renewal
Municipality/County: Richland Borough, Allegheny County
Project Site Name: Pittsburgh Cut Flower
Total Earth Disturbance Area (acres): 104.27 acres
Surface Waters Receiving Stormwater Discharges: Montour Run (TSF), UNTs to Breakneck Run (WWF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: The new development consists of two distinct development types. One section will involve the construction of 55+ community with 163 units. These 163 units will consist of 121 single family units and 21 duplex units. The other section of the development will be 11 single family Estate Lots. This modification proposes construction on the property north of Bakerstown Road of 6 multi-family residential apartment buildings totaling 170 units.
Special Conditions: 1. 4137 Bakerstown Road, LLC shall be responsible for any impairment to water uses that occur as the result of these activities. If any adverse effect results from these activities, the Department reserves the right to require that these activities be discontinued, and all necessary steps are taken to remedy the situation at the expense of the Permittee. If the Permittee discovers that any contaminated discharges occur as a result of these activities the Permittee shall cease the discharges immediately and immediately notify the Department of these discharges. 2. Earth Disturbance associated with the new limit of disturbance (13.97 acres) may not commence until any required Water Quality Management (Part II) permit for the construction and operation of the proposed sewage facilities is obtained by the Department's Clean Water Program. 3. Earth Disturbance containing pollutants shall adhere to the Department's Environmental Cleanup Program's Remedial Investigation Report/Risk Assessment/Cleanup Plan approved January 28, 2019. 4. The PCSM Volume, Rate and Water Quality calculations are based off a complete site buildout as shown on the plan sheets, as well as an assumed impervious acreage for the lots. If during construction, these assumptions are determined to be incorrect or additional impervious acreage is needed, the Department shall be contacted and informed, and a NPDES permit amendment may be necessary. 5. This permit does not authorize any obstructions or encroachments to waters, floodways, or floodplains. All water obstruction and encroachment impacts on any portion of the site subject to this permit are governed by and limited to the terms and conditions of Water Obstruction and Encroachment Permit GP040200219-006, GP050218276, GP070218221 and WV0205223-010 and the requirements of the Dam Safety and Encroachments Act and the regulations at 25 Pa. Code Chapter 105 or any subsequent approvals. Please contact the Army Corps of Engineers (Pittsburgh District) for information regarding Chapter 105 Federal authorization. 6. Earth disturbance shall adhere to the Subsurface Investigation Report dated May 29, 2024.
You may review the permit application file by contacting DEP's File Review Coordinator at 412-442-4286.
Southcentral Regional Office
Applicant: Cornwall Properties, LLC
Applicant Address: 118 Springwood Drive, Lebanon, PA 17042
Application Number: PAD380042
Application Type: New
Municipality/County: Cornwall Borough, Lebanon County
Project Site Name: Cornwall Properties
Total Earth Disturbance Area (acres): 85.51 acres
Surface Waters Receiving Stormwater Discharges: Snitz Creek (TSF, MF) and UNT to Snitz Creek (TSF, MF)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Construction of 130 single-family homes, with associated utilities and PCSM BMPs.
Special Conditions: Wetland Monitoring Criteria
You may review the permit application file by contacting DEP's File Review Coordinator at 717-705-4802.
Northeast Regional Office
Applicant: Maplewood Residential, L.P, c/o Joe Gambone
Applicant Address: 1030 W. Germantown Pike, E. Norriton, PA 19403
Application Number: PAD390143
Application Type: New
Municipality/County: Lower Milford Township, Lehigh County
Project Site Name: The Ridings at Saucon Creek—Lot 17
Total Earth Disturbance Area (acres): 1.31 acres
Surface Waters Receiving Stormwater Discharges: Saucon Creek and EV Wetlands (HQ-CWF, MF) (EV Wetlands)
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Construction of a single-family residential dwelling on Lot 17.
Special Conditions: NA—No site-specific special conditions proposed.
You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.
Northeast Regional Office
Applicant: Upper Saucon Township, c/o Thomas Beil
Applicant Address: 5500 Camp Meeting Road, Center Valley, PA 18034-8401
Application Number: PAD390292
Application Type: New
Municipality/County: Upper Saucon Township, Lehigh County
Project Site Name: North Branch Interceptor
Total Earth Disturbance Area (acres): 9.63 acres
Surface Waters Receiving Stormwater Discharges: Saucon Creek (HQ-CWF, MF); UNT to Saucon Creek (CWF, MF) and EV Wetlands
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: Proposed construction of a lift (pump) station and approximately one and six-tenths (1.6) miles of eight inch (8") diameter gravity sanitary sewer line and approximately nine-tenths (0.9) of a mile of six inch (6") diameter force main. The project is a linear utility construction (restoration) project and the limits of disturbance are approximately 12.75 acres. The work is proposed primarily adjacent to or within road right-of-way or along adjoining residential and rural properties. A lift station is proposed on an adjoining site currently used for landscaping services.
Special Conditions: NA—No site-specific special conditions proposed.
You may review the permit application file by contacting DEP's File Review Coordinator at 570-826-5472.
Southcentral Regional Office
Applicant: PDC Northeast LPIV, LLC
Applicant Address: 2442 Dupont Drive, Irvine, CA 92612
Application Number: PAD060113
Application Type: New
Municipality/County: New Morgan Borough, Berks County
Project Site Name: Proposed Southern Berks Industrial Park
Total Earth Disturbance Area (acres): 105 acres
Surface Waters Receiving Stormwater Discharges: Grace Mine Tailings Reservoir (CWF, MF) via EV wetlands and the Conestoga River (WWF, MF) via wetlands, UNTs to Conestoga River (CWF, MF) via EV and other wetlands, UNTs to Hay Creek (CWF, MF) via EV wetlands, EV wetlands, and other wetlands.
Proposed Effluent Limitations: The draft permit requires implementation of an Erosion and Sediment Control (E&S) Plan and a Post-Construction Stormwater Management (PCSM) Plan and compliance with Federal technology-based effluent standards at 40 CFR Part 450.
Rate or Frequency of Discharge: Stormwater discharges during and following earth disturbance activities are precipitation-induced and will vary depending on factors such as the area of impervious surfaces, the size and placement of best management practices (BMPs) and the intensity of precipitation.
Project Description: First phase of a multi-phase, large scale industrial park project. The first phase of the project consists of constructing an 890,000 square foot warehouse (Flying Eagle) as well as associated internal roads, parking and loading areas, utilities and stormwater management facilities.
Special Conditions: Wetland Monitoring
You may review the permit application file by contacting DEP's File Review Coordinator at 717-705-4802.
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.