Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Bulletin website includes the following: Rulemakings by State agencies; Proposed Rulemakings by State agencies; State agency notices; the Governor’s Proclamations and Executive Orders; Actions by the General Assembly; and Statewide and local court rules.

PA Bulletin, Doc. No. 18-1974

NOTICES

DEPARTMENT OF ENVIRONMENTAL PROTECTION

Applications, Actions and Special Notices


APPLICATIONS

[48 Pa.B. 7784]
[Saturday, December 22, 2018]

THE CLEAN STREAMS LAW AND THE FEDERAL CLEAN WATER ACT

APPLICATIONS FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMITS AND WATER QUALITY MANAGEMENT (WQM) PERMITS

 This notice provides information about persons who have applied for a new, amended or renewed NPDES or WQM permit, a permit waiver for certain stormwater discharges or submitted a Notice of Intent (NOI) for coverage under a General Permit. The applications concern, but are not limited to, discharges regarding industrial, animal or sewage waste, discharges to groundwater, discharges associated with municipal separate storm sewer systems (MS4), stormwater associated with construction activities or concentrated animal feeding operations (CAFO). This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92a and 40 CFR Part 122, implementing The Clean Streams Law (35 P.S. §§ 691.1—691.1001) and the Federal Clean Water Act (33 U.S.C.A. §§ 1251—1376).

Location Permit Authority Application Type or Category
Section I NPDES Renewals
Section II NPDES New or Amendment
Section III WQM Industrial, Sewage or Animal Waste; Discharge into Groundwater
Section IV NPDES MS4 Individual Permit
Section V NPDES MS4 Permit Waiver
Section VI NPDES Individual Permit Stormwater Construction
Section VII NPDES NOI for Coverage under NPDES General Permits

 For NPDES renewal applications in Section I, the Department of Environmental Protection (Department) has made a tentative determination to reissue these permits for 5 years subject to effluent limitations and monitoring and reporting requirements in their current permits, with appropriate and necessary updated requirements to reflect new and changed regulations and other requirements.

 For applications for new NPDES permits and renewal applications with major changes in Section II, as well as applications for MS4 Individual Permits and Individual Stormwater Construction Permits in Sections IV and VI, the Department, based upon preliminary reviews, has made tentative determinations of proposed effluent limitations and other terms and conditions for the permit applications. In accordance with 25 Pa. Code § 92a.32(d), the proposed discharge of stormwater associated with construction activities will be managed in accordance with the requirements of 25 Pa. Code Chapter 102. These determinations are published as proposed actions for comments prior to taking final actions.

 Unless indicated otherwise, the United States Environmental Protection Agency (EPA) Region III Administrator has waived the right to review or object to proposed NPDES permit actions under the waiver provision in 40 CFR 123.24(d).

 Persons wishing to comment on NPDES applications are invited to submit statements to the contact office noted before the application within 30 days from the date of this public notice. Persons wishing to comment on WQM permit applications are invited to submit statements to the office noted before the application within 15 days from the date of this public notice. Comments received within the respective comment periods will be considered in the final determinations regarding the applications. A comment submittal should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based.

 The Department will also accept requests for public hearings on applications. A public hearing may be held if the responsible office considers the public response significant. If a hearing is scheduled, a notice of the hearing will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. The Department will postpone its final determination until after a public hearing is held.

 Persons with a disability who require an auxiliary aid, service, including TDD users, or other accommodations to seek additional information should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.


I. NPDES Renewal Applications.

Northeast Region: Clean Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915. Phone: 570-826-2511.

NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name (Watershed No.) EPA Waived Y/N?
PA0060259
(Sewage)
Tyler Hill Camp
1017 Cochecton Turnpike
Tyler Hill, PA 18469
Wayne County
Damascus Township
Laurel Lake (on Tributary 6248 to North Branch Calkins Creek)—(1-A) Yes
PA0063401
(Sewage)
Monteforte Enterprises, Inc.
1491 Oliver Road
New Milford, PA 18834-7516
Susquehanna County
New Milford Township
Unnamed Tributary to Nine Partners Creek
(4-F)
Yes
PA0064157
(Sewage)
New Ringgold Borough Wastewater Treatment Facility
112 S. Railroad St.
New Ringgold, PA 17960
Schuylkill County
New Ringgold Borough
Little Schuylkill River
(3-A)
Yes
PA0063819
(Industrial)
Lafayette College
Easton, PA 18042
Northampton County
Easton City
Bushkill Creek
(1-F)
Yes

Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.

NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name (Watershed #) EPA Waived Y/N?
PA0262102
(Sew)
Jack A Larkin
275 Pilgert Street
Alburtis, PA 18011-2435
Berks County/
Longswamp Township
UNT Little Lehigh Creek/2-C Y
PA0080093
(Sew)
Carroll Valley Sewer &
Water Authority
5685 Fairfield Road
Fairfield, PA 17320
Adams County/
Carroll Valley Borough
UNT Tom's Creek/13-D Y
PA0261866
(Sew)
Kevin & Mariola McGee
P.O. Box 596
Birdsboro, PA 19508
Berks County/
Amity Township
UNT Monacy Creek/3-D Y
PA0032964
(Sew)
DCNR—Cowans Gap
State Park
6235 Aigjwocl Road
Fort Loudon, PA 17224-9801
Fulton County/
Todd Township
UNT Little Aughwick Creek/12-C Y
PA0081841
(Sew)
Hershey Preserve
493 S Mt. Pleasant
Lebanon, PA 17042-8945
Lebanon County/
South Annville Township
UNT Gingrich Run/7-D Y
PA0248240
(Sew)
Zemir Alic
191 Shatto Drive
Carlisle, PA 17013
Cumberland County/
North Middleton Township
Conodoguinet Creek/7-B Y

Northcentral Regional Office: Clean Water Program Manager, 208 W Third Street, Suite 101, Williamsport, PA 17701-6448. Phone: 570.327.3636.

NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name (Watershed No.) EPA Waived Y/N?
PA0229172
(Industrial)
Duncan Township Municipal Water Authority
42 Duncan Township Road
Wellsboro, PA 16901-8544
Tioga County
Duncan Township
Unnamed Tributary to Wilson Creek
(9-A)
Yes
PA0113514
(Sewage)
Madison Township
Hilner Project WWTP
P.O. Box 620
Millville, PA 17846-0620
Columbia County
Madison Township
Unnamed Tributary to Mud Creek
(10-D)
Yes
PA0228621
(Sewage)
Smithfield Township Wastewater Treatment Plant
P.O. Box 102
East Smithfield, PA 18817-0102
Bradford County
Smithfield Township
Tomjack Creek
(4-C)
Yes
PA0232360
(Sewage)
Paul & Sarah Eberly SRSTP
1255 Industrial Park Road
Milton, PA 17847-8552
Northumberland County
West Chillisquaque Township
Unnamed Tributary to Chillisquaque Creek
(10-D)
Yes

Southwest Regional Office: Clean Water Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745. Phone: 412.442.4000.

 Revision to previous permit notification that was published on December 1, 2018. This notification documents that a draft permit has been issued for comment.

NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name (Watershed No.) EPA Waived Y/N?
PA0217689
(Industrial)
Joseph A Berkley WTP
210 Perry Highway
Pittsburgh, PA 15229-1862
Allegheny County
Neville Township
Ohio River
(20-G)
Yes

Northwest Region: Clean Water Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

NPDES No.
(Type)
Facility Name &
Address
County &
Municipality
Stream Name (Watershed #) EPA Waived Y/N?
PA0239976
(Industrial Waste)
Redbank Valley WTP
243 Broad Street
New Bethlehem, PA 16242-1001
Clarion County
New Bethlehem Borough
Redbank Creek
(17-C)
No

II. Applications for New or Expanded Facility Permits, Renewal of Major Permits and EPA Non-Waived Permit Applications.

Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.

PA0247201, Industrial, SIC Code 4941, Lancaster City Water Bureau Lancaster County, P.O. Box 1599, Lancaster, PA 17608-1599. Facility Name: Susquehanna Water Treatment Plant. This existing facility is located in West Hempfield Township, Lancaster County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Industrial Waste.

 The receiving stream(s), Strickler Run, is located in State Water Plan watershed 7-G and is classified for Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 2.18 MGD.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average
Monthly
Daily
Maximum
Minimum Average
Monthly
Daily
Maximum
Instant.
Maximum
Flow (MGD) Report Report XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0 XXX XXX 9.0
Total Residual Chlorine (TRC) 0.9 XXX XXX 0.05 XXX 0.16
Total Suspended Solids Report Report XXX 30 60 75
Aluminum, Total 13.6 27.3 XXX 0.75 1.5 1.9
Iron, Total 34.5 69.1 XXX 1.9 3.8 4.8
Manganese, Total Report Report XXX 1.0 2.0 2.5

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.

 The EPA Waiver is in effect.

PA0261939, Sewage, SIC Code 6514, Sprout Brandy & Sprout Jason, 790 Oliver Street, Newport, PA 17074-8901. Facility Name: Sprout Res. This existing facility is located in Oliver Township, Perry County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated SRSTP Sewage.

 The receiving stream(s), Unnamed Tributary to Juniata River, is located in State Water Plan watershed 12-B and is classified for Cold Water Fishes and Migratory Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .0004 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average
Monthly
Average
Weekly
Minimum Annual
Average
Maximum Instant.
Maximum
Flow (MGD) Report
Annl Avg
XXX XXX XXX XXX XXX
Biochemical Oxygen Demand
 (BOD5)
XXX XXX XXX 10.0 XXX 20
Total Suspended Solids XXX XXX XXX 10.0 XXX 20
Fecal Coliform (No./100 ml) XXX XXX XXX 200 XXX 1,000

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.

 The EPA Waiver is in effect.

Northcentral Regional Office: Regional Clean Water Program Manager, 208 W Third Street, Suite 101, Williamsport, PA 17701-6448, Telephone: 570.327.3636.

PA0026239, Sewage, SIC Code 4952, University Area Joint Authority, 1576 Spring Valley Road, State College, PA 16801-8401. Facility Name: Spring Creek Pollution Control Facility. This existing facility is located in Benner Township, Centre County.

 Description of Existing Activity: The application is for a renewal of an NPDES permit for an existing discharge of treated Sewage.

 The receiving stream(s), Spring Creek, is located in State Water Plan watershed 9-C and is classified for High Quality Waters—Cold Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 6 MGD.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average
Monthly
Weekly
Average
Instant.
Minimum
Average
Monthly
Weekly
Average
Instant.
Maximum
Flow (MGD) 6.0
Annl Avg
XXX XXX XXX XXX XXX

 The proposed effluent limits for Outfall 001 are based on a design flow of 6 MGD.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average
Monthly
Weekly
Average
Instant.
Minimum
Average
Monthly
Weekly
Average
Instant.
Maximum
Flow (MGD) Report Report
Daily Max
XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0 XXX XXX 9.0
Dissolved Oxygen XXX XXX 5.0 XXX XXX XXX
Temperature (deg F) (°F) XXX XXX XXX XXX Report
Daily Max
XXX
Carbonaceous Biochemical Oxygen
 Demand (CBOD5)
500 750 XXX 10.0 15.0 20
Biochemical Oxygen Demand
 (BOD5)
 Raw Sewage Influent Report Report
Daily Max
XXX Report XXX XXX
Total Suspended Solids 500 750 XXX 10.0 15.0 20
 Raw Sewage Influent Report Report
Daily Max
XXX Report XXX XXX
Total Dissolved Solids XXX Report
Daily Max
XXX XXX Report
Daily Max
XXX
Fecal Coliform (No./100 ml)
 Oct 1 - Apr 30 XXX XXX XXX 2,000   
Geo Mean
XXX 10,000
 May 1 - Sep 30 XXX XXX XXX 200   
Geo Mean
XXX 1,000
Ultraviolet light transmittance (%) XXX XXX Report XXX XXX XXX
Nitrate-Nitrite as N XXX XXX XXX Report XXX XXX
Nitrate-Nitrite as N (Total Load,
 lbs) (lbs)
Report
Total Mo
XXX XXX XXX XXX XXX
Total Nitrogen XXX XXX XXX Report XXX XXX
Total Nitrogen (Total Load, lbs)
 (lbs)
 Effluent Net Report
Total Mo
XXX XXX XXX XXX XXX
Total Nitrogen (Total Load, lbs)
 (lbs)
Report
Total Mo
XXX XXX XXX XXX XXX
Ammonia-Nitrogen
 Jan 1 - 31 225 335 XXX 4.5 6.7 9
 Feb 1 - 28 250 375 XXX 5.0 7.5 10
 Mar 1 - 31 275 410 XXX 5.5 8.2 11
 Apr 1 - 30 200 300 XXX 4.0 6.0 8
 May 1 - 31 150 225 XXX 3.0 4.5 6
 Jun 1 - 30 125 185 XXX 2.5 3.7 5
 Jul 1 - Nov 30 50 75 XXX 1.0 1.5 2
 Dec 1 - 31 200 300 XXX 4.0 6.0 8
Ammonia-Nitrogen (Total Load, lbs)
 (lbs)
Report
Total Mo
XXX XXX XXX XXX XXX
Total Kjeldahl Nitrogen XXX XXX XXX Report XXX XXX
Total Kjeldahl Nitrogen (Total  Load, lbs) (lbs) Report
Total Mo
XXX XXX XXX XXX XXX
Phosphorus, Dissolved 6.5 XXX XXX 0.13 XXX 0.26
Total Phosphorus Report XXX XXX Report XXX XXX
Total Phosphorus (Total Load, lbs)
 (lbs)
 Effluent Net Report
Total Mo
XXX XXX XXX XXX XXX
Total Phosphorus (Total Load, lbs)
 (lbs)
Report
Total Mo
XXX XXX XXX XXX XXX
Copper, Total (µg/L) 2.68 5.37
Daily Max
XXX 53.69 107.3
Daily Max
134.2
Sulfate, Total XXX Report
Daily Max
XXX XXX Report
Daily Max
XXX
Zinc, Total 16.01 32.02
Daily Max
XXX 0.32 0.64
Daily Max
0.8
Chloride XXX Report
Daily Max
XXX XXX Report Daily Max XXX
Bromide XXX Report
Daily Max
XXX XXX Report
Daily Max
XXX
Bis(2-Ethylhexyl)Phthalate (µg/L) 0.56 1.13
Daily Max
XXX 11.32 22.64
Daily Max
28.3

 The proposed effluent limits for Outfall 001 are based on a design flow of 6 MGD.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average
Monthly
Weekly
Average
Instant.
Minimum
Average
Monthly
Weekly
Average
Instant.
Maximum
Cadmium, Total (µg/L) XXX Report
Daily Max
XXX XXX Report
Daily Max
XXX
Lead, Total XXX Report
Daily Max
XXX XXX Report
Daily Max
XXX

 The proposed monitoring requirements and effluent limits for implementation of Pennsylvania's Chesapeake Bay Watershed Implementation Plan are as follows for Outfall 001.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Monthly Annual Monthly Monthly
Average
Maximum Instant.
Maximum
Total Nitrogen (Total Load, lbs)
 (lbs) Effluent Net
XXX 164,381
Total Annual
XXX XXX XXX XXX
Total Nitrogen (Total Load, lbs)
 (lbs)
XXX Report
Total Annual
XXX XXX XXX XXX
Ammonia-Nitrogen (Total Load, lbs)
 (lbs)
XXX Report
Total Annual
XXX XXX XXX XXX
Total Phosphorus (Total Load, lbs)
 (lbs)
XXX Report
Total Annual
XXX XXX XXX XXX
 Effluent Net XXX 21,918
Total Annual
XXX XXX XXX XXX

 * This permit contains conditions which authorize the permittee to apply nutrient reduction credits to meet the Net Total Nitrogen and the Net Total Phosphorus effluent mass limits, under the Department's Chapter 96 regulations. The condition includes the requirement to report the application of these credits in Supplemental Discharge Monitoring Reports (DMRs) submitted to the Department.

 Sludge use and disposal description and location(s): The facility creates Class A biosolids marketed for public use.

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.

 The EPA Waiver is not in effect.

PA0232998, Sewage, SIC Code 4952, Eldred Township, 5558 Warrensville Road, Montoursville, PA 17754-9022. Facility Name: Eldred Township Municipal Township Bldg SFTF. This proposed facility is located in Eldred Township, Lycoming County.

 Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated SFTF Sewage.

 The receiving stream(s), Mill Creek, is located in State Water Plan watershed 10-B and is classified for Migratory Fishes and Trout Stocking, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of .0004 MGD.—Limits.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average
Monthly
Average
Weekly
Minimum Annual
Average
Maximum Instant.
Maximum
Flow (MGD) Report
Annl Avg
XXX XXX XXX XXX XXX
pH (S.U.) XXX XXX 6.0
Inst Min
XXX XXX 9.0
Total Residual Chlorine (TRC) XXX XXX Report
Avg Mo
XXX XXX XXX
Biochemical Oxygen Demand
 (BOD5)
XXX XXX XXX 10.0 XXX 20
Total Suspended Solids XXX XXX XXX 10.0 XXX 20
Fecal Coliform (No./100 ml) XXX XXX XXX 200 XXX XXX

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.

 The EPA Waiver is in effect.

PA0233005, Sewage, SIC Code 4952, Michael W. & Robin J. Fleming, 1197 Pleasant Hills Road, Williamsport, PA 17701. Facility Name: Michael W & Robin J Fleming. This proposed facility is located in Eldred Township, Lycoming County.

 Description of Proposed Activity: The application is for a new NPDES permit for a new discharge of treated SRSTP Sewage.

 The receiving stream(s), Unnamed Tributary of Millers Run, is located in State Water Plan watershed 10-B and is classified for Migratory Fishes and Warm Water Fishes, aquatic life, water supply and recreation. The discharge is not expected to affect public water supplies.

 The proposed effluent limits for Outfall 001 are based on a design flow of 0.0004 MGD.

Mass Units (lbs/day) Concentrations (mg/L)
Parameters Average
Monthly
Average
Weekly
Minimum Annual
Average
Maximum Instant.
Maximum
Flow (MGD) Report
Annl Avg
XXX XXX XXX XXX XXX
Biochemical Oxygen Demand
 (BOD5)
XXX XXX XXX 10.0 XXX 20
Total Suspended Solids XXX XXX XXX 10.0 XXX 20
Fecal Coliform (No./100 ml) XXX XXX XXX 200  
Geo Mean
XXX XXX

 You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-327-3693.

 The EPA Waiver is in effect.


III. WQM Industrial Waste and Sewerage Applications under The Clean Streams Law.

Northeast Region: Clean Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915. Phone: 570-826-2511.

WQM Permit No. 6618404, Sewage, Lemon Township Tunkhannock Township Joint Municipal Sewer Authority, 113 Tunkhannock Twp Drive, Tunkhannock, PA 18657.

 This proposed facility is located in Tunkhannock Township, Wyoming County.

 Description of Proposed Action/Activity: This is a proposal to build and operate a new 0.120 MGD sewage treatment plant to service 382 existing homes with future provisions for an additional 98 new residences. The design proposal is for an Oxidation Ditch treatment system employing an activated sludge process. It will also utilize an influent screen, sludge holding tank, dual clarifiers and dual Ultra Violet Disinfection units. The treated effluent will discharge to Tunkhannock Creek under NPDES Permit PA0276073.

WQM Permit No. 4818405, Sewage, Bethlehem Township Municipal Authority, 3535 Orth Street, Bethlehem, PA 18020.

 This proposed facility is located in Bethlehem Township, Northampton County.

 Description of Proposed Action/Activity: The project is for the construction of a pump station to serve portions of the proposed Traditions of America subdivision, the proposed Mill Creek Corporate Campus, and other existing parcels. Two pumps (one on standby) rated for 207 gallons per minute at 48.4 ft TDH will convey wastewater to a 4-inch force main. The wet well-mounted pump station includes a control building, emergency generator, ventilation, and other associated appurtenances.

Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Phone: 717-705-4707.

WQM Permit No. WQG02671803, Sewerage, York Regent Acres, LP, 4775 North Sherman St., Unit 1, Mt. Wolf, PA 17437.

 This proposed facility is located in Fairview and Newberry Townships, York County.

 Description of Proposed Action/Activity: Applicant applying for new Sewage Pumping Station.

WQM Permit No. 6718405, Sewerage, Jackson Twp. Sewer Authority, 439 Roths Church Rd, Spring Grove, PA 17362.

 This proposed facility is located in Jackson Township, York County.

 Description of Proposed Action/Activity: Applicant is applying for pump station replacements.

WQM Permit No. WQG02221802, Sewerage, Susquehanna Twp. Authority, 1900 Linglestown Rd., Harrisburg, PA 17110-3302.

 This proposed facility is located in Susquehanna Twp., Dauphin County.

 Description of Size and Scope of Proposed Operation/Activity: Applicant is applying for a Water Quality Management General Permit for Sewer Extension.

WQM Permit No. WQG02501801, Sewerage, Penn Township Municipal Authority, 102 Municipal Building Road, Duncannon, PA 17020-1130.

 This proposed facility is located in Penn Twp., Perry County.

 Description of Size and Scope of Proposed Operation/Activity: Applicant is applying for a Water Quality Management General Permit for Sewer Extension.

WQM Permit No. 1518201, CAFO, Mason's Chrome View, Ltd., 86 Chrome Rd, Nottingham, PA 19362.

 This proposed facility is located in East Nottingham Township, Chester County.

 Description of Size and Scope of Proposed Operation/Activity: Applicant is applying for a Water Quality Management.

Southwest Regional Office: Regional Clean Water Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745. Phone: 412.442.4000.

WQM Permit No. 368S010 A-3, Sewage, Center Township Sanitary Authority, 224 Center Grange Road, Aliquippa, PA 15001-1421.

 This existing facility is located in Center Township, Beaver County.

 Description of Proposed Action/Activity: Markey Run Interceptor Improvement Project.

WQM Permit No. 6518406, Sewage, Hastings Richard, P.O. Box 1466, Andover, OH 44003-1466.

 This proposed facility is located in Nottingham Township, Washington County.

 Description of Proposed Action/Activity: Installation/construction of a SRSTP to abate an on-lot malfunction.

WQM Permit No. 0308201 A-1, Industrial, Alliance Petroleum Corporation, 101 McQuiston Drive, Jackson Center, PA 16133-1633.

 This existing facility is located in South Bend Township, Armstrong County.

 Description of Proposed Action/Activity: Transfer of permit and installation of two (2) 100-barrel flow equalization tanks, a physical/chemical treatment with automatic, flow proportioned sodium sulfate feed and flocculation treatment with automatic, flow proportioned polymer feed, prior to existing precipitation ponds, for the reduction of total barium.

WQM Permit No. 2618401, Sewage, Connellsville Municipal Authority, P.O. Box 925, Connellsville, PA 15425-0925.

 This proposed facility is located in Connellsville City, Fayette County.

 Description of Proposed Action/Activity: Replacement, expansion and upgrade of existing sewage treatment plant and pump stations to addresses combined sewage overflows. The Pennsylvania Infrastructure Investment Authority (PENNVEST) which administers Pennsylvania's State Revolving Fund has been identified as a potential funding source.


IV. NPDES Individual Permit Applications for Stormwater Discharges from MS4.

Northeast Regional Office: Regional Clean Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915, Telephone: 570.826.2511.

PAI132249, MS4, Archbald Borough Lackawanna County, 400 Church Street, Archbald, PA 18403. The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Archbald Borough, Lackawanna County. The receiving streams, Lackawanna River and Wildcat Creek, is located in State Water Plan watershed 5-A and is classified for Cold Water Fishes, Migratory Fishes, High Quality—Cold Water, and Migratory Fish, aquatic life, water supply and recreation. The applicant is classified as a small MS4.

 The applicant has submitted the following plan with the application to reduce pollutant loads to impaired waters:

 • A Pollutant Reduction Plan (PRP)

 The Department has made a tentative determination to issue the NPDES permit. Written comments on the application and draft permit will be accepted for 30 days following publication of this notice. The period for comment may be extended at the discretion of DEP for one additional 15-day period. You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 570-826-5472.

 The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.

Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Telephone: 717-705-4707.

PAI133522, MS4, Womelsdorf Borough Berks County, 101 West High Street, Womelsdorf, PA 19567. The application is for a renewal of an individual NPDES permit for the discharge of stormwater from a regulated municipal separate storm sewer system (MS4) to waters of the Commonwealth in Womelsdorf Borough, Berks County. The receiving stream(s), Tulpehocken Creek and Unnamed Tributary of Tulpehocken Creek, is located in State Water Plan watershed 3-C and is classified for Migratory Fishes and Trout Stocking, aquatic life, water supply and recreation. The applicant is classified as a small MS4.

 The applicant has submitted the following plan(s) with the application to reduce pollutant loads to impaired waters:

 • A Pollutant Reduction Plan (PRP)

 The Department has made a tentative determination to issue the NPDES permit. Written comments on the application and draft permit will be accepted for 30 days following publication of this notice. The period for comment may be extended at the discretion of DEP for one additional 15-day period. You may make an appointment to review the DEP files on this case by calling the File Review Coordinator at 717-705-4732.

 The EPA waiver is in effect for small MS4s, and is not in effect for large MS4s.


VI. NPDES Individual Permit Applications for Discharges of Stormwater Associated with Construction Activities.

Southeast Region: Waterways & Wetlands Program Manager, 2 East Main Street, Norristown, PA 19401. Telephone 484-250-5160.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAD510038 NewCourtland Elder Services
6970 Germantown Avenue
Philadelphia, PA 19119
Philadelphia City of Philadelphia Delaware River
WWF

Northeast Region: Waterways and Wetlands Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915.

Lackawanna County Conservation District, 1038 Montdale Road, Scott Township, PA 18447.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAD350010 Moscow DPP, LLC
9010 Overlook Blvd.
Brentwood, TN 37027
Lackawanna Moscow Borough Langan Creek (HQ-CWF, MF)
Van Brunt Creek (HQ-CWF, MF)

Lehigh County Conservation District, 4184 Dorney Park Road, Allentown, PA 18104-5728.

NPDES
Permit No.
Applicant Name &
Address
County Municipality Receiving
Water/Use
PAD390104 Woodmont at Upper Mac, LP
100 Passaic Ave, Ste 240
Fairfield, NJ 07004
Lehigh Upper Macungie Township Cedar Creek
(HQ-CWF, MF)

VII. List of NOIs for NPDES and/or Other General Permit Types.

PAG-12 CAFOs

CAFO Notices of Intent Received.

Southcentral Region: Clean Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110. Telephone: 717-705-4707.

NPDES Permit No. PAG123611, CAFO, Petre Daniel L, 3409 Smoketown Road, Spring Grove, PA 17362.

 This existing facility is located in Manheim Township, York County.

 Description of size and scope of existing operation/activity: Poultry (Layers), Beef (Finishing): 513.34 AEUs.

 The receiving stream, Unnamed Tributary to Codorus Creek and Unnamed Tributary to West Branch Codorus Creek, is in watershed 7-H and classified for: Migratory Fishes, Warm Water Fishes, and Trout Stocking.

 The proposed effluent limits for the operation/activity include: Except for the chronic or catastrophic rainfall events defined as over the 25-year/24-hour rain storms, the CAFO general permit is a non-discharge NPDES permit. Where applicable, compliance with 40 CFR Federal effluent limitation guidelines is required. The general permit requires no other numeric effluent limitations and compliance with the Pennsylvania Nutrient Management Act and the Clean Stream Law constitutes compliance with the State narrative water quality standards.


MS4 PAG-13 Notices of Intent Received.

Southwest Regional Office: Clean Water Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745. Phone: 412.442.4000.

NPDES
Permit No.
Applicant Name & Address Municipality, County Waiver Application Submitted (Y/N) Pollutant Reduction Plan Submitted (Y/N)
PAG136404 Luzerne Township
415 Hopewell Road
Brownsville, PA 15417
Luzerne Township, Fayette County N Y

PUBLIC WATER SUPPLY (PWS) PERMITS

 Under the Pennsylvania Safe Drinking Water Act (35 P.S. §§ 721.1—721.17), the following parties have applied for PWS permits to construct or substantially modify public water systems.

 Persons wishing to comment on permit applications are invited to submit statements to the office listed before the application within 30 days of this public notice. Comments received within this 30-day comment period will be considered in the formulation of the final determinations regarding an application. A comment should include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.

 Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.

 The permit application and related documents are on file at the office listed before the application and available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.

 Persons with a disability that require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

SAFE DRINKING WATER


Applications Received Under the Pennsylvania Safe Drinking Water Act (35 P.S. §§ 721.1—721.17).

Southeast Region: Water Supply Management Program Manager, 2 East Main Street, Norristown, PA 19401, 484-250-5980.

Permit No. 0918525, Public Water Supply.

Applicant PA American Water Company
1145 Edgewood Road
Yardley, PA 19067
Township Yardley
County Bucks
Responsible Official David R. Kaufman
1145 Edgewood Road
Yardley, PA 19067
Type of Facility PWS
Consulting Engineer Gannett Fleming, Inc.
P.O. Box 67100
Harrisburg, PA 17106
Application Received Date December 6, 2018
Description of Action Disinfection modifications at the Yardley Plant, including addition of UV disinfection.

Northeast Region: Safe Drinking Water Program Manager, 2 Public Square, Wilkes-Barre, PA 18701-1915.

Application No. 4818506, Public Water Supply.

Applicant Easton Suburban Water Authority
P.O. Box 3819
Easton, PA 18043-3819
[Township or Borough] Lower Nazareth Township
Responsible Official Roy White, Manager
Easton Suburban Water Authority
P.O. Box 3819
Easton, PA 18043-3819
Type of Facility PWS
Consulting Engineer David E. Marks, PE
Gannett Fleming, Inc.
P.O. Box 67100
Harrisburg, PA 17106
Application Received Date 12/03/2018
Description of Action Project involves the construction of a new pumping station to serve the Lower Nazareth service area as well as the installation of approximately 9,500 lineal feet of suction and discharge mains including the replacement of water main along Hecktown Road. The project also includes the replacement of approximately 7,600 lineal feet of water main on Route 191.

Southcentral Region: Safe Drinking Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.

Permit No. 0718506, Public Water Supply.

Applicant Altoona Water Authority
Municipality Antis Township
County Blair
Responsible Official Mark A. Perry, General Manager
900 Chestnut Avenue
Altoona, PA 16601
Type of Facility Public Water Supply
Consulting Engineer Christopher M. Echenrode, PE
Gwin, Dobson & Foreman, Inc.
3121 Fairway Drive
Altoona, PA 16602
Application Received: 11/19/2018
Description of Action Upgrades to the existing Bellwood Water Treatment Plant including new membrane filtration system, liquid oxygen system, and chemical feed system upgrades.

Northwest Region: Safe Drinking Water Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.

Permit No. 2018502, Public Water Supply.

Applicant BPOE Meadville Lodge 219
Township or Borough City of Meadville
County Crawford
Responsible Official Dennis Duryea
Type of Facility Public Water Supply
Consulting Engineer Dennis Duryea, PE
DDsquared
220 Sylvan Drive
Lower Burrell, PA 15068
Application Received Date December 4, 2018
Description of Action 30 gal hypochlorite tank for compliance with 4-Log Treatment

WATER ALLOCATIONS


Applications received under the Act of June 24, 1939 (P.L. 842, No. 365) (35 P.S. § 631—641) relating to the Acquisition of Rights to Divert Waters of the Commonwealth.

Southcentral Region: Safe Drinking Water Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110-8200.

WA 22-1038A, Water Allocations. Pennsylvania American Water (PWS ID No. 7220017), Dauphin County. The right to purchase a maximum of 800,000 gallons per day (gpd), based on a thirty (30) day average, from the City of Lebanon Authority through an existing interconnection located in Annville Township, Lebanon County. Applicant Address: David R. Kauffman, Vice-President—Engineering, Pennsylvania-American Water, 800 West Hershey Park Drive, Hershey, PA 17033. Consulting Engineer: Anthony M. Nokovich, PE, PA American Water, 852 Wesley Drive, Mechanicsburg, PA 17055. Application Received: 10/12/2018.

AIR QUALITY

PLAN APPROVAL AND OPERATING PERMIT APPLICATIONS

 The Department has developed an ''integrated'' plan approval, State Operating Permit and Title V Operating Permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the general public. This approach allows the owner or operator of a facility to submit permitting documents relevant to its application for all sources related to a facility or a proposed project, affords an opportunity for public input, and provides for a decision on the issuance of the necessary permits.

 The Department received applications for Plan Approvals or Operating Permits from the following facilities.

 Copies of the application, the Department's analysis, all pertinent documents used in the evaluation of the application and subsequently prepared proposed plan approvals/operating permits are available for public review during normal business hours at the appropriate Department Regional Office. Appointments for scheduling a review must be made by calling the appropriate Department Regional Office. The address and phone number of the Regional Office is listed before the application notices.

 Persons wishing to file a written protest or provide comments or additional information, which they believe should be considered prior to the issuance of a permit, may submit the information to the Department's Regional Office. A 30-day comment period from the date of this publication will exist for the submission of comments, protests and information. Each submission must contain the name, address and telephone number of the person submitting the comments, identification of the proposed Plan Approval/Operating Permit including the permit number and a concise statement regarding the relevancy of the information or objections to issuance of the permit.

 A person wishing to request a hearing may do so during the 30-day comment period. A public hearing may be held, if the Department, in its discretion, decides that a hearing is warranted based on the information received. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper, the Pennsylvania Bulletin or by telephone, when the Department determines this type of notification is sufficient. Requests for a public hearing and any relevant information should be directed to the appropriate Department Regional Office.

 Permits issued to the owners or operators of sources subject to 25 Pa. Code Chapter 127, Subchapter D or E, or located within a Title V facility or subject to 25 Pa. Code § 129.51(a) or permits issued for sources with limitations on their potential to emit used to avoid otherwise applicable Federal requirements may be submitted to the United States Environmental Protection Agency for review and approval as a revision to the State Implementation Plan. Final Plan Approvals and Operating Permits will contain terms and conditions to ensure that the sources are constructed and operating in compliance with applicable requirements in the Air Pollution Control Act (35 P.S. §§ 4001—4015), 25 Pa. Code Chapters 121—145, the Federal Clean Air Act (42 U.S.C.A. §§ 7401—7671q) and regulations adopted under the Federal Clean Air Act.

 Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.


Intent to Issue Plan Approvals and Intent to Issue or Amend Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B. These actions may include the administrative amendments of an associated operating permit.

Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110.

Contact: Thomas Hanlon, Facilities Permitting Chief, 717-705-4862, Thomas Bianca, New Source Review Chief, 717-705-4863, or William Weaver, Regional Air Quality Manager, 717-705-4702.

06-05007Q: Carpenter Technology Corp. (101 Bern Street, Reading, PA 19601) to restart the Block 1 steel coil cleaning line in their specialty steel alloy manufacturing facility located in the City of Reading, Berks County. There will be no potential emission increases from this project to restart the Block 1 coil cleaning line, due to emission limits being place on it, and other equipment. The facility is a Title V facility. DEP's review of the information submitted by the applicant indicates that the air contamination sources as constructed or modified will comply with all regulatory requirements pertaining to air contamination sources and the emission of air contaminants including the best available technology requirement (BAT) of 25 Pa. Code §§ 127.1 and 127.12, and 40 CFR 63 Subpart DDDDD. Based on these findings, the Department proposes to issue a plan approval for the proposed restart of the Block 1 coil cleaning line. If, after the project has been implemented, the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specification of the application for plan approval, the requirements established in the plan approval will be incorporated into an Operating Permit pursuant to the administrative amendment provisions of 25 Pa. Code § 127.450.

Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701.

Contact: Muhammad Q. Zaman, Environmental Program Manager—Telephone: 570-327-3648.

08-00052B: REV LNG SSL BC, LLC (120 Tredegar St., Richmond, VA 23219) for the construction of three 2,175 bhp Caterpillar G3516C, 4-stroke, ultra-lean burn, natural gas fired generator engines, each equipped with an oxidation catalyst, at the proposed Towanda liquified natural gas (LNG) facility located in Herrick Township, Bradford County. The project also includes the following sources: one 302 bhp Kohler 200 REZXB standby generator equipped with an oxidation catalyst; three 60,000 gallon LNG storage tanks; an LNG truck loading station; and various fugitive emissions. The Department of Environmental Protection's (Department's) review of the information submitted by the company indicates that the air contamination sources will comply with all regulatory requirements, including monitoring, recordkeeping, and reporting requirements, and pertaining to air contamination sources and the emission of air contaminants including the National Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines, 40 CFR 63.6580—63.6675, the Standards of Performance for Stationary Spark Ignition Internal Combustion Engines, 40 CFR 60.4230—60.4248, 25 Pa. Code Chapter 123 and the best available technology requirement (BAT) of 25 Pa. Code §§ 127.1 and 127.12. Based on this finding, the Department proposes to issue a plan approval for the proposed construction.

 The emissions from each proposed Caterpillar engine included in this project will not exceed the following limits: 0.50 g/bhp-hr and 10.50 TPY NOx, 0.20 g/bhp-hr and 4.20 TPY CO, 0.15 g/bhp-hr and 3.15 TPY VOCs, 0.000588 lbs/MMBtu and 0.04 TPY SOx, 0.00999 lbs/MMBtu and 0.74 TPY PM, 0.05 g/bhp-hr and 1.05 TPY formaldehyde; no visible emissions equal to or greater than 10% for a period or periods aggregating more than three minutes in any 1 hour and equal to or greater than 30% at any time. In addition to the emission limitations, the following is a brief description of the types of conditions the Department intends to place in the plan approval in order to ensure compliance with all applicable air quality regulatory requirements: restrict the engines to natural gas firing only; performance testing requirement for all Caterpillar engines to verify compliance with the emissions limitations; in addition to performance testing, establish follow-up portable analyzer testing for NOx and CO for all Caterpillar engines every 2,500 hours of operation; establish a facility-wide leak detection and repair (LDAR) program to account for fugitive emissions from high pressure natural gas connections.

 The facility is a State Only facility. If the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specifications of the application for Plan Approval 08-0052B, the applicant will subsequently apply for a State Only Operating Permit in accordance with 25 Pa. Code Subchapter F. All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

59-00037A: Energy Water Solutions, LLC (9070 Gleannloch Forest Dr., Ste. 100, Spring, TX 77379) for the construction of three produced water evaporator/concentrator (VOX) systems, each equipped with a 9.5 MMBtu/hr, natural gas-fired burner and set of drift eliminators and each powered by a 60 kW, natural gas-fired engine/generator set, at EQT Production Company's existing Phoenix S Well Pad located in Duncan Township, Tioga County.

 The Department of Environmental Protection's (Department's) review of the information submitted by the company indicates that the air contamination sources will comply with all regulatory requirements, including monitoring, recordkeeping, and reporting requirements, and pertaining to air contamination sources and the emission of air contaminants including the National Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines, 40 CFR 63.6580—63.6675, the Standards of Performance for Stationary Spark Ignition Internal Combustion Engines, 40 CFR 60.4230—60.4248, 25 Pa. Code Chapter 123 and the best available technology requirement (BAT) of 25 Pa. Code §§ 127.1 and 127.12. Based on this finding, the Department proposes to issue a plan approval for the proposed construction. The emissions from each proposed VOX system included in this project will not exceed the following limits: 0.0023 grain per dry standard cubic foot and 6.87 TPY PM (filterable and condensable), 2.7 TPY VOCs for all three VOX units combined; no visible emissions equal to or greater than 10% for a period or periods aggregating more than three minutes in any 1 hour and equal to or greater than 30% at any time. In addition to the emission limitations, the following is a brief description of the types of conditions the Department intends to place in the plan approval in order to ensure compliance with all applicable air quality regulatory requirements: restrict the VOX systems' burners and generator engines to natural gas firing only; performance testing requirement for one of the VOX systems to verify compliance with the particulate matter emissions limitation; require periodic monitoring of the Phoenix S Well Pad water; restrict the VOX systems to processing only waters generated at the Phoenix S Well Pad; prohibit the VOX systems from processing waters that contain methanol unless prior Department approval is obtained.

 The facility is a State Only facility. If the Department determines that the sources are constructed and operated in compliance with the plan approval conditions and the specifications of the application for Plan Approval 59-00037A, the applicants will subsequently apply for a State Only Operating Permit in accordance with 25 Pa. Code Subchapter F. All pertinent documents used in the evaluation of the application are available for public review during normal business hours at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review must be made by calling 570-327-0550.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481.

Contact: David Balog, New Source Review Chief—Telephone: 814-332-6328.

16-132N: Clarion Boards, Inc. (143 Fiberboard Road, Shippenville, PA 16254), for the proposed facility VOC limit to become a synthetic minor for VOC in Paint Township, Clarion County. This is a Title V facility and will remain Title V after approval. The public notice is required for sources required to obtain a Plan Approval in accordance with 25 Pa. Code § 127.44. This plan approval will, in accordance with 25 Pa. Code § 127.450 or § 127.505, be incorporated into the facility operating permit at a later date.

 Plan approval No 16-132N is for the proposed facility VOC limit to become a synthetic minor VOC facility. This Plan Approval will contain emission restriction, testing, recordkeeping, work practice standard and additional requirement conditions, which will satisfy the requirements of 25 Pa. Code § 127.12b (pertaining to plan approval terms and conditions) and will demonstrate Best Available Technology (BAT) for the source including, but are not limited to, the following:

 • Site:

 • VOC emissions from the facility shall not exceed 49.5 tpy on a 12-month rolling basis. The facility consists of the Boards & Laminates plants.

 • Records shall be retained for a minimum of five (5) years and shall be made available to the Department, upon request.

 • The owner or operator of the facility shall maintain records that clearly demonstrate that the facility is not a major source of VOC emissions. In addition, the owner or operator shall keep records to verify compliance with the facility-wide VOC emission limitation of 49.5 tpy. The records shall be maintained, at a minimum, on a monthly basis and the emissions shall be calculated on a 12-month rolling basis. VOC emissions from sources that have conducted approved stack testing shall be calculated using the results from the latest Department approved stack testing along with actual production records. VOC emissions from sources that have not conducted approved stack testing shall be calculated using Department approved emission factor along with actual production records.

 • The facility shall submit an Application for Action for both the Boards Facility and the Laminates Facility to incorporate conditions from this plan approval into the respective facility operating permit.

 • All conditions from the Laminate facility operating permit (16-00149) revised on November 8, 2017, remain in effect unless modified in this plan approval.

 In accordance with 25 PA. Code § 127.44(f)(1), all the pertinent documents regarding this application (applications, review memos, and draft approvals) are also available for review from 8:00 a.m. to 4:00 p.m. at the Meadville Regional DEP Office (Air Quality). Appointments for scheduling a review must be made by calling the DEP at (814) 332-6340.

 In accordance with 25 Pa. Code § 127.44(f)(2), a 30-day comment period, from the date of publication, will exist for the submission of comments. Any person(s) wishing to provide DEP with additional information, which they believe should be considered prior to the issuance of this permit, may submit the information to Regional Air Quality Program Manager, Pennsylvania Department of Environmental Protection, 230 Chestnut Street, Meadville, PA 16335-3494 and must contain the name, address and telephone number of the person submitting the comments, identification of the proposed plan approval [16-132N], and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A public hearing may be held, if the Department of Environmental Protection, in its discretion, decides that such a hearing is warranted based on the comments received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, where DEP determines such notification is sufficient. Written comments or requests for a public hearing should be directed to Regional Air Quality Program Manager, Pennsylvania Department of Environmental Protection, 230 Chestnut St., Meadville, PA 16335; Phone (814) 332-6940.

 In accordance with 25 Pa. Code § 127.45, a person may oppose the proposed plan approval by filing a written protest with the Department's Northwest Region Air Quality Program Manager.

 If a plan approval has not undergone the above public notice process, the change to an operating permit must be treated as a significant modification. In these situations, the Department should follow the procedures described in §§ 127.421 to 127.431 for state only operating permits or §§ 127.521 to 127.524 for Title V operating permits.

43-252B: Grove City College (100 Campus Drive, Grove City, PA 16127), for the modification of Boiler 034 for natural gas to be the primary fuel with fuel oil as backup in Grove City Borough, Mercer County. This is a State Only facility. The public notice is required for sources required to obtain a Plan Approval in accordance with 25 Pa. Code § 127.44. This plan approval will, in accordance with 25 Pa. Code § 127.450 or § 127.505, be incorporated into the State Only operating permit at a later date.

 Plan approval No 43-252B is for the proposed modification of Boiler 034 (Source 034) by adding fuel oil as a backup fuel. The potential emissions after the modification for Boiler 034 are as follows: 0.90 tpy for PM, 0.795 tpy for PM10, 0.717 tpy for PM2.5, 11.12 tpy for NOx, 7.51 tpy for SOx, 8.11 tpy for CO, and 0.521 tpy for VOC. This Plan Approval will contain emission restriction, testing, recordkeeping, work practice standard and additional requirement conditions, which will satisfy the requirements of 25 Pa. Code § 127.12b (pertaining to plan approval terms and conditions) and will demonstrate Best Available Technology (BAT) for the source including, but are not limited to, the following:

 • Site Level:

 • No changes from plan approval 43-252A

 • Source 031 (Boiler 031):

 • No changes from plan approval 43-252A

 • Source 032 (Boiler 032):

 • No changes from plan approval 43-252A except for the following:

 • The following condition from plan approval 43-252A is deleted: Boilers 032 & 033 combined shall not exceed # 2 Fuel Oil usage of 210,000 gallons per year based on a consecutive 12-month period.

 • Source 033 (Boiler 033):

 • No changes from plan approval 43-252A except for the following:

 • Boilers 033 & 034 combined shall not exceed # 2 Fuel Oil usage of 210,000 gallons per year based on a consecutive 12-month period. [This condition replaces the following condition from plan approval 43-252A: Boilers 032 & 033 combined shall not exceed # 2 Fuel Oil usage of 210,000 gallons per year based on a consecutive 12-month period.]

 • Source 034 (Boiler 034):

 • No changes from plan approval 43-252A except for the following:

 • Subject to 40 CFR 60 Subpart Dc

 • The source shall be capable of reducing NOx and CO emissions to or below:

 • NOx: 30 ppmdv @ 3% O2 when firing natural gas

 • NOx: 90 ppmdv @ 3% O2 when firing fuel oil

 • CO: 300 ppmdv @ 3% O2

 • The source shall burn gaseous fuels not combined with any solid fuels and burn liquid fuel only during periods of gas curtailment, gas supply interruption, startups, or periodic testing on liquid fuel. Periodic testing of liquid fuel shall not exceed a combined total of 48 hours during any calendar year.

 • The source shall be fired only on gas (natural or liquefied petroleum) or No. 2 commercial fuel oil to which there has been no reclaimed or waste oil or other waste materials added. [This condition replaces the following condition from plan approval 43-252A: The source shall only burn natural gas as a fuel.]

 • Boilers 033 & 034 combined shall not exceed # 2 Fuel Oil usage of 210,000 gallons per year based on a consecutive 12-month period.

 • The permittee shall perform a stack test for SOx in accordance with 25 Pa. Code Chapter 139 and US EPA Reference Method 8 or equivalent test procedure with the source at rated capacity and burning only # 2 Fuel Oil within 90 days of burning # 2 Fuel Oil for greater than a combined total of 48 hours during the 5-year term of the facility operating permit. The permittee shall report the results (as SO2) of this test in units consistent with the emission limitation (lb/MMBtu) and the emission factor used for compliance (lb SOx per 1,000 gallons # 2 Fuel Oil burned).

 • The permittee shall maintain the following:

 • Operating log of steam flow (lbs/hr)

 • Natural gas usage (cf/hr)

 • Fuel oil usage (gallons/hr)

 • Source 035 (Miscellaneous Natural Gas Consumption):

 • No changes from plan approval 43-252A

 In accordance with 25 Pa. Code § 127.44(f)(1), all the pertinent documents regarding this application (applications, review memos, and draft approvals) are also available for review from 8:00 a.m. to 4:00 p.m. at the Meadville Regional DEP office (Air Quality). Appointments for scheduling a review must be made by calling the DEP at (814) 332-6340.

 In accordance with 25 Pa. Code § 127.44(f)(2), a 30-day comment period, from the date of publication, will exist for the submission of comments. Any person(s) wishing to provide DEP with additional information, which they believe should be considered prior to the issuance of this permit, may submit the information to Regional Air Quality Program Manager, Pennsylvania Department of Environmental Protection, 230 Chestnut Street, Meadville, PA 16335-3494 and must contain the name, address and telephone number of the person submitting the comments, identification of the proposed plan approval [43-252B], and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A public hearing may be held, if the Department of Environmental Protection, in its discretion, decides that such a hearing is warranted based on the comments received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, where DEP determines such notification is sufficient. Written comments or requests for a public hearing should be directed to Regional Air Quality Program Manager, 230 Chestnut St., Meadville, PA 16335; Phone (814) 332-6940.

 In accordance with 25 Pa. Code § 127.45, a person may oppose the proposed plan approval by filing a written protest with the Department's Northwest Region Air Quality Program Manager.

 If a plan approval has not undergone the above public notice process, the change to an operating permit must be treated as a significant modification. In these situations, the Department should follow the procedures described in §§ 127.421 to 127.431 for state only operating permits or §§ 127.521 to 127.524 for Title V operating permits.

[Continued on next Web Page]



No part of the information on this site may be reproduced for profit or sold for profit.

This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.