Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 54 Pa.B. 5598 (August 31, 2024).

25 Pa. Code § 288.625. Departmental notice and remedial action.

§ 288.625. Departmental notice and remedial action.

 The operator shall immediately notify the Department and describe remedial steps to be taken whenever:

   (1)  Operation of the facility in accordance with the approved plan cannot prevent violation of the terms of its permits, The Clean Streams Law or regulations thereunder.

   (2)  The quality or quantity of waste being disposed at the site changes from that set forth in the permit.

Cross References

   This section cited in 25 Pa. Code §  288.621 (relating to basic requirements).

APPENDIX A


TABLE I


MINIMUM LINER DESIGN STANDARDS



Liner Material Function Minimum Field Thickness (Units as Specified) Liner Density (Tests as Specified) Remarks
Geosynthetics Primary or Secondary Liner 30 mil N/A 1. A greater thickness may be required depending upon the recommendations of the manufacturer. HDPE liners shall be at least 60 MIL.
Geosynthetics Cap 30 mil N/A 1. A greater thickness may be required depending upon the recommendations of the manufacturer.
Natural &
Remodeled Clay
Secondary Liner,
Cap, Composite
Component
2 feet
2 feet
1 foot
›=90%*
›=90%*
›=90%*
1. Minimum of 30% fines by weight less than 0.074 mm particle size (# 200 sieve).
2. Plasticity Index greater than or equal to 10.
3. No coarse fragments greater than 3/4 inch in diameter.
Sodium
bentonite &
Bentonite-like
materials/soil
mixtures
Secondary Liner,
Cap, Composite
Component
2 feet
2 feet
1 foot
›=90%*
›=90%*
›=90%*
1. Minimum of 8% powdered sodium bentonite or manufacturer’s recommendations, whichever is greater.
2. No coarse fragments greater than 3/4 inch in diameter.
3. No organic matter.
Geosynthetic Clay Liner (GCL) Composite Component N/A N/A1. Minimum of 3/4 pound of powdered or granular sodium bentonite per square foot.

   * Percentage of maximum when using Standard Proctor method of design (Pa. PTM No. 106, Method B).

Cross References

   This table cited in 25 Pa. Code §  288.434 (relating to secondary liner); 25 Pa. Code §  288.436 (relating to primary liner); and 25 Pa. Code §  288.439 (relating to surface mined areas).

TABLE II


MINIMUM LINER DESIGN STANDARDS



Liner Material Function Minimum Field Thickness (Units as Specified) Liner Density (Tests as Specified) Remarks
Geosynthetics Liner, Cap 30 mil N/A 1. A greater thickness may be required depending upon the recommendations of the manufacturer. HDPE liners shall be at least 60 MIL.
Natural & Remolded Clay Cap,
Composite Component
2 feet
1 foot
›=90%*
›=90%*
1. Minimum of 30% fines by weight less than 0.074 mm particle size (#200 sieve).
2. Plasticity Index greater than or equal to 10.
3. No coarse fragments greater than 3/4 inch in diameter.
Sodium Bentonite and Bentonite-like materials Cap,
Composite Component
2 feet
1 foot
›=90%*
›=90%*
1. Minimum of 8% powdered sodium bentonite or manufacturer’s recommendations, whichever is greater.
2. No coarse fragments greater than 3/4 inch in diameter.
3. No organic matter.
Geosynthetic Clay liner (GCL) Composite Component N/A N/A 1. Minimum of 3/4 pound of powdered or granular sodium bentonite.

   * Percentage of maximum when using Standard Proctor method of design (Pa. PTM No. 106, Method B).

Cross References

   This table cited in 25 Pa. Code §  288.234 (relating to final cover and grading); 25 Pa. Code §  288.535 (relating to liner); and 25 Pa. Code §  288.538 (relating to surface mined areas).



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.