§ 299.133. Leachate and runoff control.
(a) A person or municipality required to install and maintain a storage pad or liner system under § 299.132 (relating to storage pad or liner system) shall collect leachate and runoff from the residual waste pile and divert it into a leachate storage system.
(b) A leachate storage system shall consist of a collection tank or surface impoundment. The tank or impoundment shall be:
(1) Sized for the anticipated leachate and runoff flow, including a 30-day reserve capacity.
(2) Chemically compatible with the leachate.
(3) Of sufficient strength to withstand expected loads.
(4) Equipped with cleanouts, if necessary.
(5) Sealed to prevent the loss of leachate and runoff.
(c) Collected leachate shall be treated or disposed in a manner that complies with the act, The Clean Streams Law, and the regulations promulgated thereunder.
Cross References This section cited in 25 Pa. Code § 299.101 (relating to scope).
No part of the information on this site may be reproduced for profit or sold for profit.
This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.