§ 93.8b. Metals criteria.
Dissolved criteria are footnoted in Table 5, and have been developed by applying the most current EPA conversion factors to the total recoverable criteria. The EPA factors are listed in the following Conversion Factors Table.
Conversion Factors Table
Chronic Acute Source Arsenic 1.000 (As3+) 1.000 (As3+) 1,2 Cadmium 1.101672- (ln[H] x 0.041838) 1.136672- (ln[H] x 0.041838) 2 Chromium III 0.860 0.316 1,2 Chromium VI 0.962 0.982 1,2 Copper 0.960 0.960 1,2 Lead* 1.46203- (ln[H] x 0.145712) 2 Mercury 0.85 0.85 1,2 Nickel 0.997 0.998 1,2 Selenium 0.922 0.922 1 Silver N/A 0.85 2 Zinc 0.986 0.978 1,2 * Conversion factor applies to both acute and chronic criteria.
Source 1Final Water Quality Guidance for the Great Lakes System (60 FR 15366, March 23, 1995)
Source 2Establishment of Numeric Criteria for Priority Pollutants; Revision of Metals CriteriaInterim Final Rule (60 FR 22229, May 4, 1995)
Authority The provisions of this § 93.8b amended under sections 5(b)(1) and 402 of The Clean Streams Law (35 P.S. § § 691.5(b)(1) and 691.402); and section 1920-A of The Administrative Code of 1929 (71 P.S. § 510-20).
Source The provisions of this § 93.8b adopted May 15, 2009, effective May 16, 2009, 39 Pa.B. 2523; amended July 19, 2013, effective July 20, 2013, 43 Pa.B. 4080. Immediately preceding text appears at serial pages (343957) to (343958).
Cross References This section cited in 25 Pa. Code § 16.24 (relating to metals criteria).