CONSTRUCTION TYPEMAXIMUM STORY HEIGHT
§ 54.11. Story height.
(a) B occupancies shall be governed by the story height limitations in the following table:
Construction Type Maximum Story Height Fireresistive No Limit Noncombustible 2 Story* Protected Heavy Timber 1 Story* Ordinary 1 Story* Wood Frame 1 Story* (b) *An additional story shall be permitted in noncombustible, protected heavy timber, ordinary or wood frame construction when the building is 1-hour rated construction totally protected by an automatic sprinkler system. The maximum story height may only be increased by one story.
(c) Noncombustible, protected heavy timber, ordinary and wood frame construction types shall be considered 1-hour rated construction when bearing walls, columns, beams, other supporting members, ceiling/roof assemblies, floor/ceiling assemblies, stairways, and other openings through floors are of 1-hour rated construction.
(d) Basement areas shall be 1-hour rated construction up to and including the floor/ceiling assembly between the basement and the first floor.
No part of the information on this site may be reproduced for profit or sold for profit.
This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.