§ 7.222. Floor openings.
(a) Floor openings for a manlift shall be uniform in size, be approximately circular and be located vertically above the opening below it.
(b) Floor openings for both up and down runs shall conform to the following:
Belt
(in inches)Floor Opening Width
(in inches)12 2832 14 3438 16 3640 (c) Floor openings shall extend not more than 24 inches nor more than 28 inches from the face of the belt.
Cross References This section cited in 34 Pa. Code § 7.223 (relating to landings).