§ 27.15. Intensity of illumination.
The following table shall be used in determining the illumination levels for various office tasks and locations, the column at right indicating acceptable range of footcandles required:
TABLE I
Description Acceptable Range of
Footcandles on the
Task1. General Offices General Office Work 56-70 Accounting, Bookkeeping 120-150 Drafting & Designing 120-150 Private Offices 56-70 2. Conference Rooms 1/2-70* 3. Corridors, Elevators, Escalators, Stairways 16-20 4. Lobbies, Reception Areas 10-30 5. Washrooms 24-30
*More than one lighting system and/or dimming area desirable
Not less than 1/5 the level of nearby offices
May be more when planned for transition with daylight or other areas
Source The provisions of this § 27.15 amended January 27, 1978, 8 Pa.B. 252. Immediately preceding text appears at serial pages (8448) to (8458).
No part of the information on this site may be reproduced for profit or sold for profit.
This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.