CONSTRUCTION TYPEMAXIMUM STORY HEIGHT
§ 55.11. Story height.
(a) C-2 occupancy shall be governed by the story height limitations in the following table:
Construction Type Maximum Story Height Fireresistive No Limit Noncombustible 3 Stories* Protected Heavy Timber 3 Stories* Ordinary 3 Stories* Wood Frame 2 Stories* (b) *An additional story shall be permitted in noncombustible, protected heavy timber, ordinary or wood frame construction when the building is 1-hour rated construction or totally protected by an automatic sprinkler system. The maximum story height may be increased two stories when 1-hour rated construction and total automatic sprinkler protection are provided.
(c) Noncombustible, protected heavy timber, ordinary and wood frame construction types shall be considered 1-hour rated construction when bearing walls, columns, beams, other supporting members, ceiling/roof assemblies, floor/ceiling assemblies, stairways and other openings through floors are of 1-hour rated construction.
(d) Apartment units shall be separated from each other and all other portions of the building by a minimum of 1-hour rated construction.