34 Pa. Code § 7.229. Emergency exit ladders.

§ 7.229. Emergency exit ladders.

 A fixed metal ladder accessible from both the up and down-run of the manlift shall be provided when the vertical distance between landings exceeds 20 feet, and be in accordance with existing laws governing ladders. An enclosing cage shall not be provided.

Cross References

   This section cited in 34 Pa. Code §  7.223 (relating to landings).