§ 73.13. Minimum horizontal isolation distances
(a) Minimum horizontal isolation distances shown in subsections (b)(e) shall be maintained between the sewage disposal system and the features itemized except as provided by § 72.33 (relating to well isolation distance exemption). If conditions warrant, greater isolation distances may be required.
(b) The minimum horizontal isolation distances between the features named and treatment tanks, dosing tanks, lift pump tanks, filter tanks and chlorine contact/storage tanks shall comply with the following:
(1) Property line, easement or right-of-way10 feet.
(2) Occupied buildings, swimming pools and driveways10 feet.
(3) An individual water supply or water supply system suction line50 feet.
(4) Water supply line under pressure10 feet.
(5) Streams, lakes or other surface waters25 feet.
(6) A cistern used as a water supply25 feet.
(c) The following minimum horizontal isolation distances shall be maintained between the features named and the perimeter of the aggregate in the absorption area:
(1) Property line, easement or right-of-way10 feet.
(2) Occupied buildings, swimming pools and driveways10 feet.
(3) An individual water supply or water supply system suction line100 feet.
(4) Water supply line under pressure10 feet.
(5) Streams, water courses, lakes, ponds or other surface water50 feet (for the purposes of this chapter wetlands are not surface waters).
(6) Other active onlot systems5 feet.
(7) Surface drainageways10 feet.
(8) Mine subsidence areas, mine bore holes or sink holes100 feet.
(9) Rock outcrop or identified shallow pinnacle10 feet.
(10) Natural or manmade slope greater than 25%10 feet.
(11) A cistern used as a water supply25 feet.
(12) Detention basins, retention basins and stormwater seepage beds10 feet.
(d) The following minimum horizontal isolation distances shall be maintained between the features named and the wetted perimeter of the spray field:
(1) Property lines, easements or right of ways25 feet.
(2) Occupied buildings and swimming pools100 feet.
(3) An individual water supply or water supply suction line100 feet.
(4) A cistern used as a water supply25 feet.
(5) Water supply line under pressure10 feet.
(6) Streams, watercourses, lakes, ponds or other surface waters50 feet. For the purposes of this chapter wetlands are not surface waters.
(7) Mine subsidence, boreholes, sinkholes100 feet.
(8) Roads or driveways25 feet.
(9) Unoccupied buildings25 feet.
(10) Rock outcrop25 feet.
(e) The area within the wetted perimeter of the spray field may not be sited over an unsuitable soil profile.
Authority The provisions of this § 73.13 amended under section 9 of the Pennsylvania Sewage Facilities Act (35 P. S. § 750.9); The Clean Streams Law (35 P. S. § § 691.1691.1001); and section 1920-A of The Administrative Code of 1929 (71 P. S. § 510-20).
Source The provisions of this § 73.13 adopted January 21, 1983, effective January 22, 1983, 13 Pa.B. 508.
Cross References This section cited in 25 Pa. Code § 71.63 (relating to retaining tanks); 25 Pa. Code § 72.32 (relating to sales contracts); 25 Pa. Code § 72.33 (relating to well isolation distance exemption); and 25 Pa. Code § 73.161 (relating to general).
No part of the information on this site may be reproduced for profit or sold for profit.
This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.