Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 54 Pa.B. 6234 (September 28, 2024).

25 Pa. Code § 73.53. Seepage beds.

§ 73.53. Seepage beds.

 Whenever seepage beds are employed, they shall meet the requirements of §  73.52(b)(5), (6), (8) and (10)—(16) (relating to standard trenches) in addition to the following specifications:

   (1)  The maximum slope of the undisturbed soil of a proposed absorption area where a seepage bed may be permitted is 8.0%.

   (2)  The required absorption area may be provided by one or more seepage beds:

     (i)   The individual beds of a single onlot system shall be separated by a minimum of 5 feet.

     (ii)   When elevated sand mound beds are used, the distance between beds shall be measured from the toe of the sand of each bed.

   (3)  The bed shall contain a minimum of two laterals or two opposing sets of laterals when pressure distribution is used.

   (4)  Laterals shall be equally spaced a maximum of 6 feet on center, except as provided in §  73.44(c)(8) (relating to pressurized distribution design).

   (5)  Laterals shall be placed no further than 5 feet nor less than 2 feet from the sidewalls of the bed.

   (6)  Laterals shall be placed in the bed so that the first and last discharge holes may be no more than 5 feet nor less than 2 feet from the ends of the bed.

Authority

   The provisions of this §  73.53 amended under section 9 of the Pennsylvania Sewage Facilities Act (35 P. S. §  750.9); The Clean Streams Law (35 P. S. § §  691.1—691.1001); and section 1920-A of The Administrative Code of 1929 (71 P. S. §  510-20).

Source

   The provisions of this §  73.53 adopted January 21, 1983, effective January 22, 1983, 13 Pa.B. 508; amended November 7, 1997, effective November 8, 1997, 27 Pa.B. 5877. Immediately preceding text appears at serial page (217334).

Cross References

   This section cited in 25 Pa. Code §  71.63 (relating to retaining tanks); 25 Pa. Code §  73.44 (relating to pressurized distribution design); 25 Pa. Code §  73.54 (relating to subsurface sand filters); and 25 Pa. Code §  73.55 (relating to elevated sand mounds).



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.